• Title/Summary/Keyword: Three-Dimension

Search Result 1,441, Processing Time 0.033 seconds

FINITE ELEMENT ANALYSIS OF FIN-TYPE IMPLANT FIXTURES (Fin type 임플랜트 고정체의 유한요소법적 분석)

  • Kim, Su-Gwan;Chon, Chang-Gil;Hwang, Gab-Woon;Kim, Byung-Ock
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.1
    • /
    • pp.14-25
    • /
    • 2003
  • The purpose of this study was to analyze the stress pattern in different bone densities surrounding fin-type implant fixtures under the vertical and inclined loads ($30^{\circ}) of 200N. Von-Mises stress, the pricipal stress, and the displacement on the implant fixtures under the loads were calculated by using the finite element method. Four different types of bicon implant fixture were used for this study. The geometries of implant fixtures to develop the model were used by a sales brochure and profile project. Three-dimensional finite element model of the mandible was developed with 6.0 mm implant in diameter wurrounded by approximately 2.5 mm of bone. Bone densities were classified according to the elastic modulus of the tree. The finite element program MSC PATRAN (MSC, Software Corp., USA) were used for analysis of stress distribution. The value of the Von-Mises stress, the pricipal stress, and the displacement on the implant fixtures under the vertical and inclined loads were decreased when the diameter of implant fixture was increased, and increased when the elastic modulus was decreased. The stress on implant fixture under the vertical and inclined loads was distributed through the length of implant fixtures in D3 and D4. The distribution of stress was influenced by the direction of loads. In the wide diameter of implants, the stress was developed at outer surface of bone. In conclusion, this study suggest that stress developing on the peri-implant tissues might be influenced by the dimension of implant, elastic modulus of bone, and direction of loads.

A Study on Metal Molding Using Line Transformation and Repetition - Using phosphor bronze wire (선의 변형과 반복을 활용한 금속조형 연구 - 인청동선을 활용하여)

  • Ko, Seung-Geun
    • Journal of Digital Convergence
    • /
    • v.15 no.2
    • /
    • pp.355-360
    • /
    • 2017
  • This study, which was begun in order to create a metal molding by using lines, a basic element of design, examined various characteristics and concept of line and the beauty of lines based on previous research on the subject. The result showed that formative interpretation of lines largely depends on intentional expression by using thickness and rhythm of lines. In order to obtain a metal molding that provides both visual freedom and beauty, rather than the conventional formative expression of lines, I used red copper plate and Phosphor bronze line for creating a pattern based on transformation and repetition of lines and an artwork based on the pattern. The result was not only a creation of a plane but the senses of three-dimension, speed, and unity in the overall shape. Further research will need to be conducted regarding formative interpretation of lines and emotional and intrinsic beauty through expression of lines.

Stressor, Coping Style, Communication with Mother & School Adaptation in 6th Grade Elementary School Children (초등학생의 스트레스요인, 대처방식, 어머니와의 의사소통 및 학교적응)

  • Hong Youn Lan
    • Child Health Nursing Research
    • /
    • v.6 no.3
    • /
    • pp.362-371
    • /
    • 2000
  • The purpose of this study was to examine the stressors, coping styles, communication with mother, school adaptation and predictors for school adaptation. The subjects of this study consisted of 354 children. They were 6th grade of elementary school in Taegu city. The periods of study was from march 10, to march 18, 2000. Data were analyzed by SAS computer programme. The results of this study were as follows: 1. The mean score for stressor was 39.91 in children(range 24-72). The higher stressor among three subgroups of stressor was mass media stressor. The degree of stressor revealed to be influenced significantly economic status. 2. The most frequently used coping style was problem-oriented coping style(M=18.94) in children. The degree of emotion-oriented coping style revealed to be influenced significantly family's atmosphere 3. The mean score for communication with mother was 72,44 in children(range 20- 100). The degree of communication with mother revealed to be influenced significantly sex, economic status, family' atmosphere. 4. The mean score for school adaptation was 62.48 in children(range 25-100). The higher school adaptation among five subgroup was rule dimension. The degree of school adaptation revealed to be influenced significantly sex, birth, mother's job, economic status, family's atmosphere. 5. School adaptation were positively correlated with communication with mother, problem- oriented coping style(r=0.40 p<0.001) (r=0.30 p<0.001). 6. School adaptation were negatively correlated with emotion-oriented coping style, stressor (r=-0.16 p<0.01)(r=-0.13 p<0.01). 7. Forward multiple regression analysis revealed that the most powerful predictor was the variable communication with mother accounted for 15.25% in school adaptation. All variables accounted for 25.55% in school adaptation. From the above results, it can be concluded that teaching mother about importance of communication, encouraging to use problem-oriented coping style is necessary to improve school adaptation in 6th grade elementary school children

  • PDF

Study on the Performances of Air Flow Fate Effect on a Structured Packed Tower at Adiabatic Condition in a Liquid Lithium Chloride Cooling System

  • Bakhtiar, Agung;Choi, K.H.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.404-408
    • /
    • 2009
  • The liquid desiccant air-conditioning system has been proposed as an alternative to the conventional vapor compression cooling systems to control air humidity. The complete system of liquid desiccant air-conditioning system is consisted two main components those are humidifier (regeneration) and dehumidifier. Humidifier part is connected to the load when summer season which is the air condition is hot and humid have to be turned into comfort condition on human. This paper purpose is performances study of air flow rate effect on a structured packed tower on cooling and dehumidifier system using liquid lithium chloride as the desiccant. Experimental apparatus used in this present study is consisted of three components those are load chamber, packed tower and chiller. Load chamber’s volume is $40m^3$, and packed tower dimension is cubic with length 0.4m occupied with packed column. Totally, 15 experimental has done using 5 times repeat on each variable of air velocity that varying on 2m/s, 3m/s and 4m/s with other conditions are controlled. Air inlet initial temperature and relative humidity are set respectively on $30^{\circ}C$ and 52%, desiccant flow rate is 0.63 kg/s, desiccant temperature is $10^{\circ}C$ and desiccant concentration is 0.4. The result of this study shows that averagely, the moisture removal rate and the heat transfer rate are influenced by the air velocity. Higher air velocity will increase the heat transfer and decreasing the moisture removal rate. At adiabatic condition the air velocity of 2 m/s respectively is having the higher moisture removal rate acceleration then the air velocity of 3m/s and 4 m/s until the steady state condition.

  • PDF

A Study on Energy Use Behavior according to Energy Use Awareness of Apartment Residents (공동주택 거주자의 에너지사용의식에 따른 에너지사용행동 특성분석)

  • Jung, Su-Jin;Han, Jeong-Won
    • Journal of the Korean housing association
    • /
    • v.24 no.3
    • /
    • pp.37-44
    • /
    • 2013
  • As household energy consumption has increased, serious environmental problems, such as resource depletion and global warming, are becoming global issues. It is essential to conduct the energy use of residents living in apartments in order to come up with alternative solutions for energy savings. Therefore, this study examined the energy use awareness of apartment residents and their energy use behavior by various types of awareness. To understand their energy use behavior according to the awareness of the subjects, the energy awareness dimension was created with five factors and they were subject to a cluster analysis; then, the subjects were categorized into three groups. Finally, the difference of energy use behavior was examined by groups of energy awareness. G1 represents the group that is indifferent to energy savings and believes that convenience is an important factor. Also, with respect to energy use behavior, this group tends to pursue convenience. G2 is the group that is conscious of energy use costs thereby enduring some inconvenience, and shows savings behavior in daily life and household affairs. Although, G3 is very aware of the significance for the necessity of energy saving, their energy saving behavior is relatively negative. Regarding these different characteristics of each resident group in their energy saving awareness and behaviors, diverse methods and promotion in energy education are required. Furthermore, an effective energy policy should be established based on the understanding of energy consumption.

The effect of mental hospital inpatient's perceived service quality on satisfaction and customer loyalty (정신병원 입원 환자가 인지하는 의료서비스 품질이 만족도와 충성도에 미치는 영향)

  • Jeong, Jin-Hong;Kwon, Ho-Jang;Lee, Sang-Gyu
    • Korea Journal of Hospital Management
    • /
    • v.17 no.1
    • /
    • pp.23-42
    • /
    • 2012
  • The purpose of this study is to identify the inpatient service quality at mental hospitals and to examine the effect of service quality on patient's overall satisfaction and customer loyalty. Data collection was done through conducting a survey of inpatients in three mental hospitals located in Chungnam, Korea using self administered questionnaire. The questionnaire included the modified version of 'service satisfaction scale for psychiatric patients' invented by Chul Kwon Kim and other members, which consists of five dimension of service quality: staff attitude, treatment quality, ward environment, access/cost and ward rule. Total 236 questionnaires were gathered and 219 were used for analysis. The data was analyzed by using version SAS9.2 and path analysis model was applied to test our hypothesis. As a result, the four factors of service (staff attitude, treatment quality, ward environment and ward rule) were extracted, which counted for 62.89% of the common variance. Moreover, Cronbach Alpha showed relatively high internal consistency of answer, all exceeding 0.6. According to the study, ward environment and treatment quality turned out to have direct influence on the patient's satisfaction. In addition, staff attitude and overall satisfaction directly influenced the customer loyalty while ward environment and ward rule indirectly had influence using overall satisfaction as a medium. In conclusion, in order to enhance the satisfaction and customer loyalty in mental hospitals, efforts in improving environmental service quality in particular is highly demanded.

  • PDF

Measurements on Effects of Locations of Obstacles in an Explosion Chamber

  • Han, Jae-Beom;Lee, Young-Soon;Park, Dal-Jae
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.3
    • /
    • pp.68-74
    • /
    • 2008
  • Measurements were performed to investigate the effects on flame and pressure development by varying locations of multiple obstacles in a top-venting explosion chamber. The chamber dimension was 1000 mm in height with a $700\;{\times}\;700\;mm^2$ cross-section and a rectangular vent area of $700\;{\times}\;700\;mm^2$. Three different multiple obstacles with blockage ratio of 30% were used by changing from 200 mm, 500 mm to 800 mm in heights within the chamber. Temporally resolved flame front images were recorded by a high speed camera to investigate the interaction between the propagating flame and the obstacles. The results showed that the triangular bar caused the fastest flame developments at given times whereas the lowest was obtained with the cylindrical bar. It was also found that local flame displacement speeds of different obstacles were sensitive to the locations of obstacles. The local speed becomes larger in going from 200 mm, to 500 mm and to 800 mm in heights. The obstacles in height of 800 mm yielded the highest overpressure whereas the lowest was in height of 200 mm.

  • PDF

A Study on the Development of Men’s Formal Pants Pattern (남성 정장 바지원형 설계에 관한 연구)

  • 백경자;이정란
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.8
    • /
    • pp.1524-1535
    • /
    • 2001
  • The purpose of this study was to establish a sizing system according to size and dimension whereby manufactured pants can be classified and develop men’s formal pants pattern based on the analysis of ready-made and educational pants pattern. The first, we surveyed the sizing and the basic pants patterns of the men’s ready-made wear companies, Secondly, through the survey data of the domestic men’ready-mad clothing industry, we proposed a new sizing system. Lastly, after compared three different types of ready-mad pants manufactured according to their patterns and an additional type of pants made after the educational pattern, the new men’s basic pants pattern were developed. The findings were as follows: 1. Survey of the domestic ready-mad garment industry showed that each company classified its own manufactured goods according to its own sizing system: moreover, they each used its own unique patterns which appeared to be resulted from a combination of two factors : the experience of a patterner and foreign know-how technology. 2. New sizing system was developed with 12 steps from size 74-88 to size 96-106 based on the high frequencies of the companies’3. New basic patterns for men’s formal pants were developed: Inseam length = 80cm, crotch line = H/4+4.6cm, pants ham = 23.5cm as basic lines and front waist girth =W/4+9.1cm as drafting line. 4. the superiority of the new basic patterns were been demonstrated by a high approval rate of the subjects who participated in testing.

  • PDF

A Study on Digitalization of Fashion Textile Design - A Study of Fashion Textile CAD Design According to Digitalization - (패션텍스타일 디자인의 디지털화 연구 -디지털화에 따른 패션텍스타일 CAD디자인의 활용가치 연구-)

  • 강혜승;권민희
    • Archives of design research
    • /
    • v.17 no.1
    • /
    • pp.289-298
    • /
    • 2004
  • With the advance of digital technology, development of exclusive CAD system for fashion textile that may suggest the future of fashion textile industry is increasingly accelerated. To build up the foundation of digital culture, it is required for fashion textile industry to develop goods with high value added and make rapid change of production system, and actually, exclusive programs are being developed to meet with the desire. Present study considers the vicissitude of fashion textile and the composition and characteristics of design system, and compares and analyses a variety of design developments of digital fashion textile. And it systemizes the expansion and change of creative digital pattern designs that are developed differing from existing graphic program, the expression of suitable textile texture, and the simulation effect by three-dimension modeling. By separating the usage of CAD system for fashion textile into designing and producing aspects, it also focuses on increasing the usage of exclusive CAD system for fashion textile.

  • PDF

Free Vibration Characteristics of Rectangular Plates under Uniform Thermal Loading Part II. Experimental Modal Test (균일 열부가 하중을 받는 사각판의 자유 진동특성 연구 Part II. 고유진동 실험)

  • Jeon, Byoung-Hee;Kang, Hui-Won;Lee, Young-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.2
    • /
    • pp.106-113
    • /
    • 2011
  • This paper was conducted on experimental analysis in the free vibration analysis of rectangular plates under uniform thermal loading. Materials of three rectangular plates were aluminum, steel and stainless-steel respectively. The dimension of rectangular plates was 0.1 $\times$ 0.1 $\times$ 0.002 m. Infrared quartz lamps were used for thermal loading. The PCS(Power Control System) electric control system was applied for control and scanning vibrometer (Poly Tech) was used for acquisition of frequency response function. Applied temperature was increased from room temperature to $300^{\circ}C$ by $50^{\circ}C$. Boundary condition was free-free condition using bungee cord. Front face of rectangular plate was heated uniformly.