• Title/Summary/Keyword: Three wavelength

Search Result 483, Processing Time 0.027 seconds

Evaluation of the KASI Detector Performance Test System Using an Andor iKon M CCD Camera

  • Yu, Young Sam;Kim, Jinsol;Park, Chan;Jeong, Woong-Seob;Kim, Minjin;Choi, Seonghwan;Park, Sung-Joon
    • Journal of Astronomy and Space Sciences
    • /
    • v.35 no.3
    • /
    • pp.201-210
    • /
    • 2018
  • The characterization of detectors installed in space- and ground-based instruments is important to evaluate the system performance. We report the development of a detector performance test system for astronomical applications using the Andor iKon M CCD camera. The performance test system consists of a light source, monochromator, integrating sphere, and power meters. We adopted the Czerny-Tuner monochromator with three ruled gratings and one mirror, which covers a spectral range of 200-9,000 nm with a spectral resolution of ~1 nm in the visible region. Various detector characteristics, such as the quantum efficiency, sensitivity, and noise, can be measured in wide wavelength ranges from the visible to mid-infrared regions. We evaluated the Korea Astronomy and Space Science Institute (KASI) detector performance test system by using the performance verification of the Andor iKon-M CCD camera. The test procedure includes measurements of the conversion gain ($2.86e^-/ADU$), full well capacity ($130K\;e^-$), nonlinearity, and pixel defects. We also estimated the read noise, dark current, and quantum efficiency as a function of the temperature. The lowest measured read noise is $12e^-$. The dark current at 223 K was determined to be $7e^-/s/pix$ and its doubling temperature is $5.3^{\circ}C{\pm}0.2^{\circ}C$ at an activation energy of 0.6 eV. The maximum quantum efficiency at 223 K was estimated to be $93%{\pm}2%$. We proved that the quantum efficiency is sensitive to the operating temperature. It varies up to 5 % in the visible region, while the variation increases to 30 % in the near-infrared region. Based on the comparison of our results with the test report by the vendor, we conclude that our performance test results are consistent with those from the vendor considering the test environment. We also confirmed that the KASI detector performance test system is reliable and our measurement method and analysis are accurate.

A Rapid Method for Estimating the Levels of Urinary Thiobarbituric Acid Reactive Substances for Environmental Epidemiologic Survey

  • Kil, Han-Na;Eom, Sang-Yong;Park, Jung-Duck;Kawamoto, Toshihiro;Kim, Yong-Dae;Kim, Heon
    • Toxicological Research
    • /
    • v.30 no.1
    • /
    • pp.7-11
    • /
    • 2014
  • Malondialdehyde (MDA), used as an oxidative stress marker, is commonly assayed by measuring the thiobarbituric acid reactive substances (TBARS) using HPLC, as an indicator of the MDA concentration. Since the HPLC method, though highly specific, is time-consuming and expensive, usually it is not suitable for the rapid test in large-scale environmental epidemiologic surveys. The purpose of this study is to develop a simple and rapid method for estimating TBARS levels by using a multiple regression equation that includes TBARS levels measured with a microplate reader as an independent variable. Twelve hour urine samples were obtained from 715 subjects. The concentration of TBARS was measured at three different wavelengths (fluorescence: ${\lambda}-_{ex}$ 530 nm and ${\lambda}-_{em}$ 550 nm; ${\lambda}-_{ex}$ 515 nm and ${\lambda}-_{em}$ 553 nm; and absorbance: 532 nm) using microplate reader as well as HPLC. 500 samples were used to develop a regression equation, and the remaining 215 samples were used to evaluate the validity of the regression analysis. The induced multiple regression equation is as follows: TBARS level (${\mu}M$) = -0.282 + 1.830 ${\times}$ (TBARS level measured with a microplate reader at the fluorescence wavelengths ${\lambda}-_{ex}$ 530 nm and ${\lambda}-_{em}$ 550 nm, ${\mu}M$) -0.685 ${\times}$ (TBARS level measured with a microplate reader at the fluorescence wavelengths ${\lambda}-_{ex}$ 515 nm and ${\lambda}-_{em}$ 553 nm, ${\mu}M$) + 0.035 ${\times}$ (TBARS level measured with a microplate reader at the absorbance wavelength 532 nm, ${\mu}M$). The estimated TBARS levels showed a better correlation with, and are closer to, the corresponding TBARS levels measured by HPLC compared to the values obtained by the microplate method. The TBARS estimation method reported here is simple and rapid, and that is generally in concordance with HPLC measurements. This method might be a useful tool for monitoring of urinary TBARS level in environmental epidemiologic surveys with large sample sizes.

The Experimental study of B.E.P.(Biological Energy Projector) on the swimming Time of Mice and on the Recovery of Muscular Fatigue of Rats (B.E.P.가 생쥐의 수영능(水泳能)과 수영부하(水泳負荷)로 야기(惹起)된 흰쥐의 피로회복(疲勞恢復)에 미치는 실험적(實驗的) 연구(硏究))

  • Lee, Cheol-Wan
    • Journal of Haehwa Medicine
    • /
    • v.4 no.1
    • /
    • pp.357-371
    • /
    • 1995
  • We have completed a study to measure the contents of glucose, BUN, creatinine. LDH, and T-protein with respect to a fatigued condition in the bloods of rats which a constant swimming is loaded and to measure the maximun swimming time of mice The test has been carried out as a part of the basic study on the efficacy of B. E. P. (Biological Energy Projector) for emitting a light energy having a specific wavelength out of far-infrared rays. As a result. We have reached the following conclusions: 1. At testing of mice's maximun swimming time, all of B.E.P.(2. 4. 8. 24hrs) treated group have been increased in comparison with the control group, but only 24hrs-B.E.P. treated group significantly increased during 4 weeks. 2. The contents of glucose, BUN. creatinine, LDH, and T-protein measured immediately after the swimming of mice have been distinctly changed but not been significantly changed at their increase and decrease in comparison with the control group. 3. At 3rd day out of the swimming loading, the contents of glucose in the blood serum of the white rat have been distinctly increased in comparison with the control group. And 24hrs-B.E.P treated group surpassed 8hrs-B.E.P. treated group. 4. At 1st and 3rd day, the contents of creatinine in the blood serum of the white rat have been distinctly increased at B.E.P. (8, 24hrs) treated groups in comparison with the control group and have been recovered to the condition of the normal group. 5. After three days, the contents of BUN in the blood serum of the white rat have been significantly decreased in B.E.P.(8, 24hrs) treated groups at 3rd day in comparison with the control group and have been recovered to the condition of the normal group. 6. The contents of LDH in the blood serum of the white rat have been decreased in B.E.P.(8, 24hrs) treated groups at 3rd day in comparison with the control group, in particular 24hrs-B.E.P. treated group has been decreased distinctly than the normal group. 7. The contents of T-protein in the blood serum of the white rat have been distinctly increased in B.E.P. (8, 24hrs) treated groups at 3rd day in comparison with the control and normal group. As the above results, it has been proved that the execise of mice and the fatigue metabolism of rats were influenced by the light energy emitted the B.E.P., and it has been also proved that the external stimulation could be used as a preferable stimulative factor for the biological metabolism. If the clinical training and study are positively achieved, the B.E.P. would be used as curative means and preventive measures for helping human body.

  • PDF

3-Dimensional LADAR Optical Detector Development in Geiger Mode Operation (Geiger Mode로 동작하는 3차원 LADAR 광수신기 개발)

  • Choi, Soon-Gyu;Shin, Jung-Hwan;Kang, Sang-Gu;Hong, Jung-Ho;Kwon, Yong-Joon;Kang, Eung-Cheol;Lee, Chang-Jae
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.4
    • /
    • pp.176-183
    • /
    • 2013
  • In this paper, we report the design, fabrication and characterization of the 3-Dimensional optical receiver for a Laser Detection And Ranging (LADAR) system. The optical receiver is composed of three parts; $16{\pm}16$ Geiger Mode InGaAs Avalanche Photodiode (APD) array device operated at 1560 nm wavelength, Read Out Integrated Circuit (ROIC) measuring the Time-Of-Flight (TOF) of the return signal reflected from target objects, a package and cooler maintaining the proper operational condition of the detector and control electronics. We can confirm that the LADAR system can detect the signal from a target up to 1.2 km away, and it showed low Dark Count Rate (DCR) of less than 140 kHz, and higher than 28%-Photon Detection Efficiency (PDE). This is considered to be the best performance of the $16{\pm}16$ FPA APD optical receiver for a LADAR system.

Fabrication of the photon scanning tunneling microscope with constant intensity mode (일정광량 방식의 광자주사현미경 제작)

  • Kim, Ji-Taek;Choi, Wan-Hae;Jo, Jae-Heung;Chang, Soo;Kim, Dal-Hyun;Koo, Ja-Yong;Chung, Seung-Tae
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.3
    • /
    • pp.195-200
    • /
    • 1999
  • We made sharp optical fiber tips with less than 100 nm diameter by using the heating and pulling method with a good repetition and fabricated the photon scanning tunneling microscope (PSTM) using constant intensity mode. The 3-dimensional PZT (Piezoelctric transducer) scanner made of a long PZT tube is consisted of three divided parts, that is, a pair of $\pm$ x and a pair of $\pm$y scanning parts and a z scanning part for the fine approach and scanning. The scanning dimension is 1.43 $\mu\textrm{m}$$\times$1.76 $\mu\textrm{m}$. The height of a optical tip to maintain a constant height within $1/{\lambda}_0$ (${\lambda}_0$ is the incident wavelength) from surface of a specimen to a optical tip is controlled automatically by using the electric feedback circuit. The 3-dimensional shape of standing evanescent waves generated on the surface of a dove prism was measured successfully by using the constant intensity mode PSTM.

  • PDF

Fabrication of Large Area Transmission Electro-Absorption Modulator with High Uniformity Backside Etching

  • Lee, Soo Kyung;Na, Byung Hoon;Choi, Hee Ju;Ju, Gun Wu;Jeon, Jin Myeong;Cho, Yong Chul;Park, Yong Hwa;Park, Chang Young;Lee, Yong Tak
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.220-220
    • /
    • 2013
  • Surface-normal transmission electro-absorption modulator (EAM) are attractive for high-definition (HD) three-dimensional (3D) imaging application due to its features such as small system volume and simple epitaxial structure [1,2]. However, EAM in order to be used for HD 3D imaging system requires uniform modulation performance over large area. To achieve highly uniform modulation performance of EAM at the operating wavelength of 850 nm, it is extremely important to remove the GaAs substrate over large area since GaAs material has high absorption coefficient below 870 nm which corresponds to band-edge energy of GaAs (1.424 eV). In this study, we propose and experimentally demonstrate a transmission EAM in which highly selective backside etching methods which include lapping, dry etching and wet etching is carried out to remove the GaAs substrate for achieving highly uniform modulation performance. First, lapping process on GaAs substrate was carried out for different lapping speeds (5 rpm, 7 rpm, 10 rpm) and the thickness was measured over different areas of surface. For a lapping speed of 5 rpm, a highly uniform surface over a large area ($2{\times}1\;mm^2$) was obtained. Second, optimization of inductive coupled plasma-reactive ion etching (ICP-RIE) was carried out to achieve anisotropy and high etch rate. The dry etching carried out using a gas mixture of SiCl4 and Ar, each having a flow rate of 10 sccm and 40 sccm, respectively with an RF power of 50 W, ICP power of 400 W and chamber pressure of 2 mTorr was the optimum etching condition. Last, the rest of GaAs substrate was successfully removed by highly selective backside wet etching with pH adjusted solution of citric acid and hydrogen peroxide. Citric acid/hydrogen peroxide etching solution having a volume ratio of 5:1 was the best etching condition which provides not only high selectivity of 235:1 between GaAs and AlAs but also good etching profile [3]. The fabricated transmission EAM array have an amplitude modulation of more than 50% at the bias voltage of -9 V and maintains high uniformity of >90% over large area ($2{\times}1\;mm^2$). These results show that the fabricated transmission EAM with substrate removed is an excellent candidate to be used as an optical shutter for HD 3D imaging application.

  • PDF

Photobiomodulation and Miescher's cheilitis granulomatosa: case report

  • Porrini, Massimo;Garagiola, Umberto;Rossi, Margherita;Bosotti, Moreno;Marino, Sonia;Gianni, Aldo Bruno;Runza, Letterio;Spadari, Francesco
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.35.1-35.6
    • /
    • 2020
  • Background: Miescher's cheilitis granulomatosa (MCG) is a rare chronic inflammatory disease and is known as the monosymptomatic clinical form of Melkersson-Rosenthal syndrome (MRS). It is characterised by swelling of one or both lips and more frequently affects the upper lip. Histopathological findings show the presence of numerous inflammatory infiltrates and granuloma formations. Pharmacological treatments and surgery have provided results that are positive yet insufficiently stable in the long term. The clinical case described is of a 68-year-old female patient with a diagnosis of MCG of the upper lip. Case presentation: The patient was diagnosed and treated at the Oral Medicine and Oral Pathology outpatient clinic of Maxillofacial and Odontostomatology Unit, Fondazione Cà Granda IRCCS Ospedale Maggiore Policlinico. The patient was recommended localised treatments of photobiomodulation (PBM) using a diode laser with a 635 nm and 980 nm dual-wavelength (λ) approach, a 600-micron fibre, and a handpiece with a 1-cm-diameter lens at 300 mW. Three treatments a week were administered for four weeks for a total of 12 treatment sessions (T1-T12). After that, the patient had a long follow-up period of about 2 years. The therapeutic results were clear from the initial stages of treatment. There was an immediate, gradual, and consistent reduction in labial swelling. A reduction in the size of the lip by about 35% at T10-T12 was observed, returning the size and volume of the upper lip within the normal clinical range. The painful symptoms subsided after the seventh treatment (T7). The histopathological check at 3 months and the follow-up in particular confirmed the disease was in remission with satisfactorily stable treatment results. Moreover, the patient did not use any other treatments on the area from the early laser treatments through to the end of the follow-up period. Conclusions: Our experience describes a clinical case of MCG treated with PBM and effectively resolved with a reduction of the lip swelling. The real success of the treatment emerged over time, showing that the tissue healing was stable. In absence of any collateral phenomena, this confirms the effective and documented therapeutic potential of PBM for chronic inflammatory infiltrates.

Reduction of VOCs and the Antibacterial Effect of a Visible-Light Responsive Polydopamine (PDA) Layer-TiO2 on Glass Fiber Fabric (Polydopamine (PDA)-TiO2 코팅 유리섬유 직물을 이용한 VOCs의 저감 성능 및 항균성 연구)

  • Park, Seo-Hyun;Choi, Yein;Lee, Hong Joo;Park, Chan-gyu
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.6
    • /
    • pp.540-547
    • /
    • 2021
  • Background: Indoor air pollutants are caused by a number of factors, such as coming in from the outside or being generated by internal activities. Typical indoor air pollutants include nitrogen dioxide and carbon monoxide from household items such as heating appliances and volatile organic compounds from building materials. In addition there is carbon dioxide from human breathing and bacteria from speaking, coughing, and sneezing. Objectives: According to recent research results, most indoor air pollution is known to be greatly affected by internal factors such as burning (biomass for cooking) and various pollutants. These pollutants can have a fatal effect on the human body due to a lack of ventilation facilities. Methods: We fabricated a polydopamine (PDA) layer with Ti substrates as a coating on supported glass fiber fabric to enhance its photo-activity. The PDA layer with TiO2 was covalently attached to glass fiber fabric using the drop-casting method. The roughness and functional groups of the surface of the Ti substrate/PDA coated glass fiber fabric were verified through infrared imaging microscopy and field emission scanning electron microscopy (FE-SEM). The obtained hybrid Ti substrate/PDA coated glass fiber fabric was investigated for photocatalytic activity by the removal of ammonia and an epidermal Staphylococcus aureus reduction test with lamp (250 nm, 405 nm wavelength) at 24℃. Results: Antibacterial properties were found to reduce epidermal staphylococcus aureus in the Ti substrate/PDA coated glass fiber fabric under 405 nm after three hours. In addition, the Ti substrate/PDA coated glass fiber fabric of VOC reduction rate for ammonia was 50% under 405 nm after 30 min. Conclusions: An electron-hole pair due to photoexcitation is generated in the PDA layer and transferred to the conduction band of TiO2. This generates a superoxide radical that degrades ammonia and removes epidermal Staphylococcus aureus.

Analysis of calcium fluoride single crystal grown by the czochralski method (초크랄스키 방법으로 성장한 CaF2 단결정 분석)

  • Lee, Ha-Lin;Na, Jun-Hyuck;Park, Mi-Seon;Jang, Yeon-Suk;Jung, Hea-Kyun;Kim, Doo-Gun;Lee, Won-Jae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.32 no.6
    • /
    • pp.219-224
    • /
    • 2022
  • CaF2 single crystal has a large band gap (12 eV), and it is used for optical windows, prisms, and lenses due to its excellent transmittance in a wide wavelength range and low refractive index. Moreover, it is expected to be one of the materials for ultraviolet transmissive laser optical components. CaF2 belongs to the fluoride compounds and has a face-centered cubic (FCC) structure with three sub-lattices. The representative method for CaF2 single crystal growth is Czochralski, which method has the advantages of high production efficiency and the ability to make large crystals. In this study, X-ray diffraction (XRD), X-ray rocking curves (XRC) measurement, and chemical etching were performed to analyze the crystallinity and defect density of the CaF2 single crystals, grown by the Czochralski method. Fourier-transform infrared spectroscopy (FT-IR) and UV-VIS-NIR spectroscopy systems were used to investigate the optical properties of the CaF2 crystal. The provability of various applications, including UV application, was systematically investigated with various analysis results.

Catadioptric NA 0.6 Objective Design in 193 nm with 266 nm Autofocus (이중 파장 심자외선 카타디옵트릭 NA 0.6 대물렌즈 광학 설계)

  • Do Hee Kim;Seok Young Ju;Jun Ho Lee;Hagyong Kihm;Ho-Soon Yang
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.2
    • /
    • pp.53-60
    • /
    • 2023
  • We designed a catadioptric objective lens with a 0.6 numerical aperture (NA) for semiconductor inspection at 193 nm. The objective lens meets major requirements such as a spatial resolution of 200 nm and a field of view (FOV) of 0.15 mm or more. We selected a wavelength of 266 nm for autofocus based on the availability of the light source. First, we built the objective lenses of three lens groups: a focusing lens group, a field-lens group, and an NA conversion group. In particular, the NA conversion group is a group of catadioptric lenses that convert the numerical aperture of the beam focused by the prior groups to the required value, i.e., 0.6. The last design comprises 11 optical elements with root-mean-squared (RMS) wavefront aberrations less than λ/80 over the entire field of view. We also achieved the athermalization of the objective lens with focus-shift alone satisfying the performance of RMS wavefront aberration below λ/30 at a temperature range of 20 ± 1.2 ℃.