• 제목/요약/키워드: Three phase

검색결과 6,253건 처리시간 0.04초

삼상일체화된 자속구속형 SFCL의 사고종류에 따른 소자들의 퀜치 특성 (Quench Characteristics of HTSC Elements according to fault types in Integrated Three-Phase)

  • 박충렬;이종화;박식;두호익;임성훈;최효상;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.960-962
    • /
    • 2005
  • In this paper, we investigated the quench characteristics of high-Tc superconducting(HTSC) elements in the integrated three-phase flux-lock type superconducting fault current limiter(SFCL) according to fault types such as the single-line-to-ground fault, the double-line-to-ground fault, the line-to-line fault and the triple-line-to-ground fault. The integrated three-phase flux-lock type SFCL is an upgrade version of single-phase flux-lock type SFCL. The structure of the integrated three-phase flux-lock type SFCL consisted of a three-phase flux-lock reactor wound on an iron core with the ratio of the same turn between coil 1 and coil 2 in each phase. When the SFCL is under the normal condition, the flux generated in the iron core is zero because the flux generated between two coils of each single phase is canceled out. Therefore, the SFCL's impedance is zero, and the SFCL has negligible influence on the power system. However, if a fault occurs in any single one of three phases, the flux generated in the iron core is not zero any more. The flux makes HTSC elements of all phases to quench irrespective of the fault type, which reduces the current in fault phase as well as the current of sound phase. It was obtained that the fault current limiting characteristics of the suggested SFCL were dependent on the quench characteristics of HTSC elements in all three phases.

  • PDF

Current-Programmed Control of Three Phase PWM AC-AC Boost Converter

  • Choi, Nam-Sup;Li, Yulong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.414-416
    • /
    • 2005
  • In this paper, a new scheme of current programmed control for three phase PWM AC-AC converter is presented. By considering only the magnitude components, a similar scheme in the DC-DC converter can be extended to the three phase PWM AC-AC converter. The proposed current programmed control will be well adopted into various converter topologies though three phase PWM AC-AC boost converter is treated as an example. The converter analysis is carried out by applying the vector DQ transformation to obtain physical insight into the converter operation. Finally, the experiment result shows the validity of the proposed scheme.

  • PDF

3상 자속구속형 한류기의 초전도 소자 직렬연결 특성분석 (Characteristics of Superconducting Elements in Series-Connected Three-Phase Flux-Lock type SFCL)

  • 박형민;최효상;조용선;황종선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.35-36
    • /
    • 2007
  • We investigated the characteristics of three phase flux-lock type SFCL. Three phase flux-lock type consists of three reactor wound on an iron core in each single phase and the secondary coil is connected to the superconducting elements in series. the superconducting elements with serial connection were quenched simultangously in the single line-to-ground fault.

  • PDF

3상 4레그 전압형 인버터를 위한 3차원 공간벡터변조 기법 (3-Dimensional SVM Technique for the Three-Phase Four-Leg Voltage Source Inverter System)

  • 도안반투안;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.111-112
    • /
    • 2013
  • The three-phase four-leg voltage source inverter (VSI) topology can be an interesting option for the three phase-four wire system. With an additional leg, this topology can handle the neutral current, hence the DC link capacitance can be reduced significantly. In this paper the three dimensional space vector modulation (3D SVM) in ${\alpha}{\beta}{\gamma}$ coordinates for the three-phase four-leg VSI is presented. By using the 3D SVM method, the DC link voltage can be reduced by 16% compared with the split DC link capacitor topology and the output distortion can also be reduced under the unbalanced load condition.

  • PDF

고조파 성분이 포함된 전압 불평형 운전시 유도전동기의 동작 특성 해석 (Analysis on the Operation Characteristics of Induction Motor Operated by Unbalanced Voltage with Harmonics Components)

  • 김종겸;박영진;이은웅
    • 전기학회논문지P
    • /
    • 제54권3호
    • /
    • pp.134-140
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are usually balanced and connected to three power systems. However, in the user power distribution systems, partial loads are single & three phase and unbalanced, generating voltage unbalance by the impedance mismatching. Voltage unbalance has detrimental effects on three-phase induction motors, including over heating, line-current unbalance, derating, torque pulsation, low efficiency, etc. This paper presents a scheme on operation states of a three-phase induction motor under the unbalanced voltages with harmonics components. Three-phase voltages applied to the stator winding of the studied induction motor are controlled by respectively adjusting not only fundamental but also harmonics components. Harmonic components at the voltage unbalanced factor(VUF) of the three-phase source voltages can then be examined the different values of VUF on machine's operation characteristics.

3상 교류전원 LED 램프의 광 플리커 (Light Flicker of Three-Phase AC-powered LED Lamp)

  • 이동원;김병철
    • 한국전기전자재료학회논문지
    • /
    • 제27권4호
    • /
    • pp.262-267
    • /
    • 2014
  • This study describes that light flicker of LED lamp is improved by placing an AC-powered LED block in each phase of three-phase AC power. Rectified current is considered as an instantaneous luminous flux because the current flowing through the LED block is proportional to the amount of light emitted by the LED block. Percent flicker is calculated simply by modeling the rectified current flowing through the LED block to a triangular wave current. Percent flicker is 100% in single-phase AC powered LED lamp. Percent flicker of the same level as that in an incandescent lamp (6%~14%) is however, achieved if light emission starts before $40^{\circ}$ in each voltage phase of three-phase AC power.

가극 결선한 삼상 자속구속형 초전도 한류기의 사고유형별 퀜치 특성 (Quench Characteristics of Three-Phase Flux-Lock type SFCL connected Additive Winding According to Fault Types)

  • 조용선;박형민;남긍현;이나영;최효상;박충렬;임성훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.155-156
    • /
    • 2005
  • We investigated the quench characteristics of the flux-lock type superconducting fault current limiter (SFCL) integrated three-phase according to fault types such as the single-line-to-ground fault, the double-line-to-ground fault and the three-line-to-ground. The structure of integrated three-phase flux-lock type SFCL consists of single core which have three-phase flux-lock reactors. The superconducting elements connected sound phase as well as fault phase happened to quenching. Therefore we conformed that the superconducting elements were dependent.

  • PDF

삼상 분리형 자속구속형 전류제한기의 동작 특성 분석 (Analysis of Operational Characteristics of Separated Three-Phase Flux-Lock SFCL)

  • 두승규;두호익;박충렬;김민주;김용진;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.289-289
    • /
    • 2008
  • We investigated the operational characteristics of the separated three-phase flux-lock type superconducting fault current limiter (SFCL). The single-phase lock type SFCL consist of two coils, which are wound in parallel through an iron core. The high-$T_c$ superconducting(HSTC) thin film connected in series with secondary coil. The separated three-phase flux-lock type SFCL consist of three single-phase flux-lock type SFCL. In a normal condition, the SFCL is not operate. When a fault occurs, the current of a HSTC thin film exceeds its critical current by fault current, the resistance of the HSTC thin film generated. Therefore fault current was limited by SFCL. The separated three-phase flux-lock type SFCL are operated in fault condition such as the the single line-to-ground fault, the double line-to-ground fault and the triple line-to-ground fault. The experimental results, the SFCL operational characteristics was dependent on fault condition.

  • PDF

배터리 충·방전기 시스템에 적용되는 3상 양방향 절연형 인터리브드 DC-DC 컨버터의 병렬운전 (Parallel Operation of Three-Phase Bi-Directional Isolated Interleaved DC-DC Converters for The Battery Charge/Discharge System)

  • 조현식;이재도;차한주
    • 전력전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.15-22
    • /
    • 2014
  • Recently, parallel operation of dc-dc converters has been widely used in distributed power systems. In this paper, a control method to achieve parallel operation of three-phase bi-directional isolated interleaved dc-dc converters is discussed for the battery charging and discharging system which consists of the 32 battery charger/dischargers and two three-phase bi-directional isolated interleaved dc-dc converters. In the boost mode, the battery energy is delivered to the grid, whereas the grid energy is transferred to the battery in the buck mode operation. The average current sharing control method is employed to obtain an equal conducting of each phase current in the three-phase dc-dc converter. By using the proposed method, the imbalance factor is gratefully reduced from 8 percent to 1 percent. Two 2.5kW three-phase bi-directional dc-dc converter prototype have been built and the proposed method has been verified through experiments.

농어촌 동력용 전동기구를 위한 단상/3상변환기의 개발에 관한 연구 (Study on single/three phase converter for motor applications of rural district)

  • 황영문;조철제
    • 전기의세계
    • /
    • 제25권4호
    • /
    • pp.68-72
    • /
    • 1976
  • This study is initiated to solve the problem that the development of an electric machine to drive heavy horse-power load required in the rural district, where only single phase supply is available, is very urgent. As a method for this purpose, the single/three phase converter by single phase induction machine with a tapped auxiliary winding, running unloaded mechanically under single-phase source and supplying three-phase output to a loaded 3-phase induction motor, is devised and the pilot machine is put into test. Analysis based on hybrid equivalent circuit for the phase converter and symmertical component theory for the 3-phase load motor and practical experiment result in that optimum auxiliary winding ratio is to be 1.25 rather than theoretical .root.3/2 in order to keep the voltage unbalance ratio of 3-phase output from the converter as low as possible in both cases of starting and running the load motor.

  • PDF