• Title/Summary/Keyword: Three dimensional finite element analysis and Stress distribution

Search Result 238, Processing Time 0.026 seconds

Three-dimensional finite element analysis of the stress distribution and displacement in different fixation methods of bilateral sagittal split ramus osteotomy

  • Yun, Kyoung In;Cho, Young-Gyu;Lee, Jong-Min;Park, Yoon-Hee;Park, Myung-Kyun;Park, Je Uk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.5
    • /
    • pp.271-275
    • /
    • 2012
  • Objectives: This study evaluated a range of fixation methods to determine which is best for the postoperative stabilization of a mandibular osteotomy using three-dimensional finite element analysis of the stress distribution on the plate, screw and surrounding bone and displacement of the lower incisors. Materials and Methods: The model was generated using the synthetic skull scan data, and the surface model was changed to a solid model using software. Bilateral sagittal split ramus osteotomy was performed using the program, and 8 different types of fixation methods were evaluated. A vertical load of 10 N was applied to the occlusal surface of the first molar. Results: In the case of bicortical screws, von-Mises stress on the screws and screw hole and deflection of the lower central incisor were minimal in type 2 (inverted L pattern with 3 bicortical repositioning screws). In the case of plates, von-Mises stress was minimal in type 8 (fixation 5 mm above the inferior border of the mandible with 1 metal plate and 4 monocortical screws), and deflection of the lower central incisor was minimal in types 6 (fixation 5 mm below the superior border of the mandible with 1 metal plate and 4 monocortical screws) and 7 (fixation 12 mm below the superior border of the mandible with 1 metal plate and 4 monocortical screws). Conclusion: Types 2 and 6 fixation methods provide better stability than the others.

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF MANDIBULAR STRESSES OF COMPLETE DENTURE OCCLUSION (하악 총의치 교합형태에 따른 하부조직에 미치는 교합력 양태의 3차원적 유합요소법 해석)

  • Lee Young-Soo;Yoo Kwang-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.2
    • /
    • pp.286-318
    • /
    • 1992
  • The objective of preventive dentistry is the maintenance of a healthy dentition for the life of a patient. Unfortunately, if an individual has not received the benefit of a comprehensive program of preventive dentistry and has finally reached the edentulous state, as a consequence, he receives a set of complete denture. Dentures are mechanical devices and subject to the principles of mechanics. In some cases, the general health and nutritional status of the patient are felt to be the causative factors. But, the most important thing in residual ridge resorption is felt to be caused by the unequal distribution of functional forces. This study was to analyze mandibular stresses of complete denture occlusion by three dimensional finite element method. The results were as follows ; 1. As deformation and stress distribution of the complete denture of the mandible were concentrated on the upper lingual side of the mandible, alveolar ridge resorption of the mandible occurred from lingual side to labio-buccal side. 2. Analyzing by three dimensional F. E. M., the mandible is a very effective form for tolerating stress and deformation biomechanically. 3. According to the concentration of stress distibution in the upper buccal side of the lower posteriors, buccal shelf area must be a primary stress bearing area in the lower complete denture. 4. Lower complete denture moved horizontally to the balancing side under lateral occlusal force. 5. Bilateral balanced occlusion should be constructed in the complete denture for denture stability, especially in the protrusive movement. 6. Physical property of the denture base material was as important for stress distribution in the denture base as or even more than that in the mandible. 7. Impression technique is very important because of most of stress was concentrated between them due to close contact of the mandible and the denture base.

  • PDF

A STUDY ON THE CONNECTION MODALITY BETWEEN IMPLANT AND TOOTH IN OSSEOINTEGRATED PROSTHETIC TREATMENT USING FINITE ELEMENT ANALYSIS (골유착성 임플랜트 보철치료시 자연지대치와의 연결형태에 관한 유한요소적 응력분석 연구)

  • Kim Yong-Ho;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.3
    • /
    • pp.1-32
    • /
    • 1991
  • Tho osseointegrated dental prosthetic treatment has develped for the edentulous patient with severely resorbed alveolar ridge, and has given us a successful clinical results to date. Nowadays the partially edentulism is included among the indications of the osseointegrated prosthetic treatment. The purpose of this study was to analyze the stress distribution at supporting bone according to the types of connection modality between implant and tooth in the superstructure. Two dimensional finite element stress analysis was applied for this study. FEM models were created using software Super SAP for MBM 16bit personal computer. Three modalities of connection were modeled and analyzed under load condition. The results were as follws: 1. The stress develped at tooth and implant in the cancellous bone was lower in the case of rigid connection than in the case of norigid connection, but higher between the two implants in the case of rigid connection than in the case of nonrigid connection. 2. The stress developed at the cortical bone and at the supporting bone interface was lower in the case of rigid connection than in the case of nonrigid connection 3. The stress developed at the supporting tissue interface of the implant nearby the tooth, was lower in the case of rigid connection than in the case of nonrigid connection. 4. The stress developed at the supporting tissue interface of posteriormost implant, was same between the cases of rigid and nonrigid connection. 5. The stress distribution related to the freestanding case was generally similar to the stress distribution pattern of nonrigid connection case. 6. The magnitude of applied load which produces deformation within elastic limit, had influence on the absolute value of stress, but had no influence on the pattern of stress distribution of the same case.

  • PDF

Method of Deciding Elastic Modulus of Left and Right Ventricle Reconstructed by Echocardiography Using Finite Element Method and Stress Analysis

  • Han, Geun-Jo;Kim, Sang-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.2
    • /
    • pp.217-224
    • /
    • 1994
  • In order to study the shape and dimensions of heart, a procedure to reconstruct a three dimensional left ventricular geometry from two dimensional echocardiographic images was studied including the coordinate transformation, curve fitting and interpolation utilizing three dimensional position registration arm. Nonlinear material property of the left ventricular myocardium was obtained by finite element method performed on the reconstructed geometry and by optimization techniques which compared the computer predicted 3D deformation with the experimentally determined deformation. Elastic modulus ranged from 3.5g/$cm^2$ at early diastole to l53g/$cm^2$ at around end diastole showing slightly nonlinear relationship between the modulus and the pressure. Afterwards using the obtained nonlinear material propertry the stress distribution related with oxyzen consumption rate was analyzed. The maximum and minimum of ${\sigma}_1$ (max. principal stress) occurred at nodes on the second level intersection points of x-axis with endocardium and with epicardium, respectively. And the tendency of the interventricular septum to be flattened was observed from the compressive ${\sigma}_1$ on the anterior, posterior nodes of left ventricle and from the most significant change of dimension in $D_{RL}$ (septal-lateral dimension of right ventricle).

  • PDF

A Study on the Thermal Stress Analysis of a Piston in a Turbocharged Diesel Engine (터보 디젤엔진 피스톤의 열응력 해석에 관한 연구)

  • 국종영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.2
    • /
    • pp.92-98
    • /
    • 2001
  • We determined the transfer coefficient through the analysis of three dimensional temperature distribution in comparison with the measured temperature on the piston in the turbocharged diesel engine. And we analyzed the thermal stress and the thermal deformation with that heat transfer coefficient by using finite element method. According to this results, we found that maximum tempetature range of the piston appeared at the upper part of the piston crown and that the heat transfer coefficient of the upper part of the piston is smaller than that of the lower one. It showed that the maximum thermal deformation is shown at the edge of the upper part of piston and that the maximum thermal stress was shown on the lower part of the piston crown. Finally, we defined the method of determination of a piston heat transfer analysis by using measured temperature on the piston and analyzed temperature with finite element method.

  • PDF

Numerical Analysis for Temperature Distribution and Thermal Stresses in a Turbocharged Large CNG Engine Piston (터보과급 대형 CNG기관 피스톤의 온도분포와 열응력 해석)

  • Kim, Yang-Sul;An, Su-Chul
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.4
    • /
    • pp.58-62
    • /
    • 2008
  • The purpose of this paper is to establish a standard finite element analysis model of a piston by carrying out three dimensional modeling of a series six-cylindered CNG engine's piston to forecast temperature distribution at stationary state and the following thermal stress and variation, and cross checking it with existing analysis. Also, in order to evaluate the affects of the cooling system to the piston's heat load, the paper analyzed piston's temperature and thermal stress distribution according to the cooling water temperature changes and the following variations. As a result, the maximum temperature was found at the center of the crown in the piston and the maximum thermal stress occurred from the lower part of the piston.

  • PDF

THE THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PARTIALLY EDENTULOUS IMPLANT PROSTHESIS WITH VARYING TYPES OF NON-RIGID CONNECTION (부분 무치악 임플랜트 보철 수복시 자연치와의 비고정성 연결형태에 따른 3차원 유한요소법적 연구)

  • Lee, Seon-A;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.1
    • /
    • pp.101-124
    • /
    • 1996
  • In this study, we designed the finite element models of mandible with varying their connecting types between the prosthesis on implant fixture and 2nd premolar, which were free-standing case(Mf), precision attachment case(Mp), semiprecision attachment case(Ms) and telescopic case(Mt). The basic model of the designed finite element models, which contained a canine and the 1st & 2nd premolar, was implanted in the edentulous site of the 1st & 2nd molar by two implant fixtures. We applied the load in all models by two ways. A vertical load of 200N was applied at each central fossa of 2nd premolar and 1st implant. A tilting load of 20N with inclination of $45^{\circ}$ to lingual side was applied to buccal cusp tips of each 2nd premolar and 1st implant. And then we analyzed three-dimensional finite element models, making a comparative study of principal stress and displacement in four cases respectively. Three-dimensional finite element analysis was performed for the stress distribution and the displacement using commercial software(IDEAS program) for SUN-SPARC workstation. The results were as follows : 1 Under vertical load or tilting load, maximum displacement appeared at the 2nd premolar. Semiprecision case showed the largest maximum displacement, and maximum displacement reduced in the order of precision attachment, free-standing and telescopic case. 2. Under vertical load. the pattern of displacement of the 1st implant appeared mesio-inclined because of the 2nd implant splinted together. But displacement pattern of the 2nd premolar varied according to their connection type with prosthesis. The 2nd premolar showed a little mesio-inclined vertical displacement in case of free-standing and disto-inclined vertical displacement due to attachment in case of precision and semiprecision attachment. In telescopic case, the largest mesio-inclined vertical displacement has been shown, so, the 1st premolar leaned mesial side. 3. Under tilting load, The pattern of displacement was similar in all four cases which appeared displaced to lingual side. But, the maximum displacement of 2nd premolar appeared larger than that of the first implant. Therefore, there was large discrepancy in displacement between natural tooth and implant during tilting load. 4. Under vertical load, the maximum compressive stress appeared at the 1st implant's neck. Semiprecision attachment case showed the largest maximum compressive stress, and the maximum compressive stress reduced in the order of precision attachment, telescopic and free-standing case. 5 Under vertical load, the maximum tensile stress appeared at the 2nd implant's distal neck. Semiprecision attachment case showed the largest maximum tensile stress, and the maximum tensile stress reduced in the order of precision attachment, telescopic and free-standing case. 6. Under vertical load or tilting load, principal stress appeared little between natural tooth & implant in free-standing case, but large principal stress was distributed at upper crown and distal contact site of the 2nd premolar in telescopic case. Principal stress appeared large at keyway & around keyway of distal contact site of the 2nd premolar in precision and semiprecision attachment case, appearing more broad and homogeneous in precision attachment case than in semiprecision attachment case.

  • PDF

THE EFFECT OF RESTORATIVE MATERIALS ON THE STRESS DISTRIBUTION OF CLASS V COMPOSITE RESIN RESTORATIONS - A 3D FINITE ELEMENT INVESTIGATION (수복재료가 5급 복합레진 수복물의 응력분포에 미치는 영향에 관한 3차원유한요소법적 연구)

  • Ahn, Hyoung-Ryoul;Kim, Hyeon-Cheol;Hur, Bock;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.20-29
    • /
    • 2006
  • The purpose of this study was to analyze the stress distribution aspect of unrestored and restored combined shape (wedge shape occulusally and saucer shape gingivally) class V cavity, which found frequently in clinical cases. A maxillary second permolar restored with a combined shape class V composite restorations were modeled using the three dimensional finite element method. Static occlusal load of 170 N was applied on lingual incline of buccal cusp at the angle of $45^{\circ}$ with the longitudinal axis of the tooth. And three dimensional finite element analysis was taken by ANSYS (Version 6.0, Swanson Analysis System Co., Houston, U.S.A) program which represent the stress distribution on unrestored and restored cavity wall and margin. The conclusions were as follows. 1. Compared to the unrestored cavity, Von Mises stress at the cementoenamel junction and line angle of the cavity base were reduced and in restored cavity. 2. Von Mises stress at the occlusal and cervical cavity margin and wall were increased in restored cavity in comparison with the unrestored cavity. 3. In the hybrid and hybrid/flowable composite resin restoration, Von Mises stress at the cementoenamel junction and line angle of the cavity base were reduced more than in the flowable restoration. 4. In the hybrid and hybrid/flowable composite resin restoration, Von Mises stress at the occlusal and cervical cavity margin and wall were increased more than in the flowable restoration.

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE EFFECTS OF ALVEOLAR BONE LOSS ON STRESS DISTRIBUTION IN POST-RECONSTRUCTED TEETH (치조골 흡수가 포오스트로 인한 치근내 응력에 미치는 영향에 관한 삼차원 유한요소법 분석)

  • Lee, Ky-Young;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.674-696
    • /
    • 1997
  • There're many cases that should be reconstructed with post and core when clinical crown is destructed. But this post and core restoration may cause damaging stress on the teeth. Previous finite element study was restricted to normal bone model relatively close to cemen-toenamel junction. Moreover, the test of a model with diminished bone support was rare. The purpose of this study is to test the effects of alveolar bone loss on the magnitude, stress distribution and displacement of post reconstructed teeth. In this study, it was assumed that the coronal portion of upper incisor was severely destructed. After conventional endodontic treatment, it was restored with post and core. The PFM restoration was made on it. This crown was cemented with ZPC. Alveolar bone was classified by 4 types of bone, such as normal, 2 mm, 4 mm, 6 mm bone, according to the bone loss. Meanwhile, the material of post are divided into 2 types of materials, such as gold, co-cr. Force was applied to two directions. One was fuctional maximum bite force (300 N) applied to the spot just lingual to the incisal edge with the angle of 45 degree to the long axis of the tooth, and the other one was horizontal force (300 N) applied to the labial surface. The results analyzed with three dimensional finite element method were as follows : 1. Stress was concentrated on the adjacent dentin of the post apex, one third portion of the post apex and the labial & lingual mid-portion of the root in all case. The stress of middle third of the root was apparently concentrated on the labial aspect. 2. The stress on adjacent dentin of the post apex and one third of the post apex increased as alveolar bone height moved apically. This increase was dramatic beyond 4 mm bone loss model. 3. The stress of the post apex was spreaded to the middle third of the post and greater than gold post in the case of metal post. 4. The displacement of the neck of post was the greatest in one of the post-cement interface and this increased as alveolar bone height moved apically. Besides the displacement of the metal post is slightly lower than one of the gold post.

  • PDF

Three-dimensional finite element analysis for influence of marginal bone resorption on stress distribution in internal conical joint type implant fixture (변연골 흡수가 내측연결 임플란트 매식체의 응력분포에 미치는 영향)

  • Yun, Mi-Jung;Yoon, Min-Chul;Eom, Tae-Gwan;Huh, Jung-Bo;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • Purpose: The change of the marginal bone around dental implants have significance not only for the functional maintenance but also for the esthetic success of the implant. The purpose of this study was to investigate the load transfer of internal conical joint type implant according to marginal bone resorption by using the three-dimensional finite element analysis model. Materials and methods: The internal conical joint type system was selected as an experimental model. Finite element models of bone/implant/prosthesis complex were constructed. A load of 300 N was applied vertically beside 3 mm of implant axis. Results: The pattern of stress distribution according to marginal bone resorption was similar. The maximum equivalent stress of implant was increase according to marginal bone resorption and the largest maximum equivalent stress was shown at model of 1 mm marginal bone resorption. Although marginal bone loss more than 1mm was occurred increasing of stress, the width of the stress increase was decreasing. Conclusion: According to these results, the exposure of thin neck portion of internal conical joint type implant is most important factor in stress increasing.