• 제목/요약/키워드: Three Screw Pump

검색결과 3건 처리시간 0.019초

대용량 토출용 나사펌프 개발에 관한 연구 (A Study on the Development of a Screw Pump with Wide Range Discharge Performance)

  • 황영국
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.417-422
    • /
    • 2022
  • In this study, the development of a three-screw pump for high-capacity discharge was carried out. Benchmarking and reverse engineering for advanced products were performed to design and manufacture power rotor and idler rotor for high capacity and high pressure. Through flow analysis, performance verification of the entire design was performed and prototypes were manufactured. As a result of performance evaluation on prototypes, it was found that the development specifications were satisfied.

액상실리콘 재료의 균일한 혼합비율을 위한 이송방식에 대한 비교 분석 (A Comparison Analysis of the Feeding Method for the Uniform Mixing Rate of the Liquid Silicone Materials)

  • 추성민;김영민;이금원
    • 한국정보전자통신기술학회논문지
    • /
    • 제12권4호
    • /
    • pp.380-386
    • /
    • 2019
  • 본 논문은 이송방식에 따른 혼합비율을 비교하기 위하여 동일 점도를 가지는 원재료를 사용하여 100 사이클 동안 주재료와 부재료의 투입량 오차를 측정하고 분석하였다. 측정 결과 피스톤 펌프 방식에서는 주재료와 부재료의 투입량 오차는 0g에서 3g까지 변화의 폭이 컸으며, 최대 오차비율은 10.3%로 큰 편차를 보였다. 듀얼-스크류 회전방식에서는 0.01g에서 0.4g으로 최대 오차 비율이 0.41%로 투입량 오차가 거의 발생하지 않았으며, 공정 사이클이 증가함에도 거의 균등하게 투입됨을 알 수 있었다. 듀얼-스크류 회전방식 이액형 혼합시스템을 이용하여 원재료의 점도가 다른 3종류의 액상 실리콘을 사용하여 100 사이클 동안의 주재료와 부재료의 투입량을 측정하고 분석하였다. 그 결과 적용한 원재료의 점도에 관계없이 평균 오차가 0.75g, 오차 비율은 1% 미만으로 측정되었으며, 동일 점도를 갖는 원재료를 사용했을 때 피스톤 펌프 방식의 평균 오차 비율은 4.09 %로 측정되었다. 이 결과는 듀얼-스크류 회전방식을 적용한 실험에서 일정한 혼합비율로 주재료와 부재료가 투입됨을 알 수 있었다.

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.