• Title/Summary/Keyword: Three Dimensional CT

Search Result 514, Processing Time 0.026 seconds

Three-dimensional imaging modalities in endodontics

  • Mao, Teresa;Neelakantan, Prasanna
    • Imaging Science in Dentistry
    • /
    • v.44 no.3
    • /
    • pp.177-183
    • /
    • 2014
  • Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualized on a two-dimensional image. This review discusses the role of CT in endodontics, pertaining to its importance in the diagnosis of root canal anatomy, detection of periradicular lesions, diagnosis of trauma and resorption, presurgical assessment, and evaluation of the treatment outcome.

COMPARATIVE STUDY OF THREE-DIMENSIONAL RECONSTRUCTIVE IMAGES OF FACIAL BONE USING COMPUTED TOMOGRAPHY (전산화단층상을 이용한 안면골의 3차원재구성상의 비교 연구)

  • Song Nam-Kyu;Koh Kwang-Joon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.2
    • /
    • pp.283-290
    • /
    • 1992
  • The purpose of this study was to evaluate the spatial relationship of facial bone more accurately. For this study, the three-dimensional images of dry skull were reconstructed using computer image analysis system and three-dimensional reconstructive program involved CT. The obtained results were as follows: 1. Three-dimensional reconstructive CT results in images that have better resolution and more contrast 2. It showed good marginal images of anatomical structure on both three-dimensional CT and computer image analysis system, but the roof of orbit, the lacrimal bone and the squamous portion of temporal bone were hardly detectable. 3. The partial loss of image data were observed during the regeneration of saved image data on three-dimensional CT. 4. It saved the more time for reconstruction of three-dimensional images using computer image analysis system. But, the capacity of hardware was limited for inputting of image data and three-dimensional reconstructive process. 5. We could observe the spatial relationship between the region of interest and the surrounding structures by three-dimensional reconstructive images without invasive method.

  • PDF

A Study on the Fabrication and Comparison of the Phantom for Computed Tomography Image Quality Measurements Using Three-Dimensions Printing Technology (삼차원 프린팅 기술을 이용한 전산화단층영상 품질 측정용 팬텀 제작 및 비교 연구)

  • Yoon, Myeong-Seong;Hong, Soon-Min;Heo, Yeong-Cheol;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.595-602
    • /
    • 2018
  • Quality control (QC) of Computed Tomography (CT) devices is based on image quality measurement on AAPM CT phantom which is a standard phantom. Although it is possible to control the accuracy of the CT apparatus, it is expensive and has a disadvantage of low penetration rate. Therefore, in this study, we make image quality measurement phantom at low cost using FFF (Fused Filament Fabrication) type three-dimensional printer and try to analyze the usefulness, compare it with existing standard phantom. To print a phantom, We used three-dimensional printer of the FFF system and PLA (Poly Lactic Acid, density: $1.24g/cm^3$) filament, and the CT device of 64 MDCT (Aquilion CX, Toshiba, Japan). In addition, we printed a phantom using three-dimensional printer after design using various tool based on existing standard phantom. For image quality evaluation, AAPM CT phantom and self-generated phantom were measured 10 times for each block. The measured data were analyzed for significance using the Mannwhiteney U-test of SPSS (Version 22.0, SPSS, Chicago, IL, USA). As a result of the analysis, phantom fabricated with three-dimensional printer and standard phantom showed no significant difference (p>0.05). Furthermore, we confirmed that image quality measurement performance of a phantom using three-dimensional printer is similar to the existing standard phantom. In conclusion, we confirmed the possibility of low cost phantom fabrication using three dimensional printer.

Airway Reactivity to Bronchoconstrictor and Bronchodilator: Assessment Using Thin-Section and Volumetric Three-Dimensional CT

  • Boo-Kyung Han;Jung-Gi Im;Hak Soo Kim;Jin Mo Koo;Hong Dae Kim;Kyung Mo Yeon
    • Korean Journal of Radiology
    • /
    • v.1 no.3
    • /
    • pp.127-134
    • /
    • 2000
  • Objective: To determine the extent to which thin-section and volumetric three-dimensional CT can depict airway reactivity to bronchostimulator, and to assess the effect of different airway sizes on the degree of reactivity. Materials and Methods: In eight dogs, thin-section CT scans were obtained before and after the administration of methacholine and ventolin. Cross-sectional areas of bronchi at multiple levels, as shown by axial CT, proximal airway volume as revealed by three-dimensional imaging, and peak airway pressure were measured. The significance of airway change induced by methacholine and ventolin, expressed by percentage changes in cross-sectional area, proximal airway volume, and peak airway pressure was statistically evaluated, as was correlation between the degree of airway reactivity and the area of airways. Results: Cross-sectional areas of the bronchi decreased significantly after the administration of methacholine, and scans obtained after a delay of 5 minutes showed that normalization was insufficient. Ventolin induced a significant increase in cross-sectional areas and an increase in proximal airway volume, while the effect of methacholine on the latter was the opposite. Peak airway pressure increased after the administration of methacholine, and after a 5-minute delay its level was near that of the control state. Ventolin, however, induced no significant decrease. The degree of airway reactivity did not correlate with airway size. Conclusion: Thin-section and volumetric spiral CT with three-dimensional reconstruction can demonstrate airway reactivity to bronchostimulator. The degree of reactivity did not correlate with airway size.

  • PDF

A proposal of landmarks for craniofacial analysis using three-dimensional CT imaging (3차원 CT 영상을 이용한 두개악안면 분석을 위한 계측점의 제안)

  • Chang, Hye-Sook;Baik, Hyoung-Seon
    • The korean journal of orthodontics
    • /
    • v.32 no.5 s.94
    • /
    • pp.313-325
    • /
    • 2002
  • Three-dimensional CT imaging is efficient in examining specific structures in the craniofacial area by reproducing actual measurements through minimization of errors from patient movement and image magnification. Due to the rapid development of digital image technology and the expansion of treatment range a need for developing three -dimensional analysis has become urgent. Therefore the purpose of this study was to evaluate the percentage of error and magnification of three-dimensional CT using a dried skull and Vworks $program^{TM}$ (Cybermed Inc., Seoul, Korea) and also to obtain landmarks that are easy to designate and reproduce in three-dimensional images using the Vmorph-proto $program^{TM}$ (Cybermed Inc., Seoul, Korea). The following conclusions were obtained, 1. In the comparison of actual measurements from the dried skull and the three-dimensional image obtained from the Vworks program, the mean error was 0.99mm and the magnification was 1.04%. 2. Clinically useful hard tissue landmarks from three-dimensional images were Supraorbitale, Lateral orbital margin, Infraorbitale, Nasion, ANS, A point, Zygomaticomaxilla, Upper incisor, Lower incisor, B point, pogonion, Menton, PNS, Condylar inner margin, Condylar outer margin, Porion, Condylion, Gonionl, Gonion2, Gonion3, Sigmoid notch and Basion. 3. Clinically useful soft tissue landmarks from three-dimensional images were Endocanthion, Exocanthion, Soft tissue Nasion, Pronasale, Alare lateralis, Upper nostril point, Lower nostril point, Subnasale, Upper lip point, Cheilion, Stomion, Lower lip center, Soft tissue B, Pogonion, Menton and Preaurale. The Vworks program can be considered a clinically efficient tool to produce and measure three-dimensional images. Most of the hard and soft tissue landmarks proposed above are anatomically important points which are also easily reproducible and designated. These landmarks can be beneficial in three-dimensional diagnosis and the prediction of changes before and after surgery.

Multi-Detector Row CT of the Central Airway Disease (Multi-Detector Row CT를 이용한 중심부 기도 질환의 평가)

  • Kang, Eun-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.3
    • /
    • pp.239-249
    • /
    • 2003
  • Multi-detector row CT (MDCT) provides faster speed, longer coverage in conjunction with thin slices, improved spatial resolution, and ability to produce high quality muliplanar and three-dimensional (3D) images. MDCT has revolutionized the non-invasive evaluation of the central airways. Simultaneous display of axial, multiplanar, and 3D images raises precision and accuracy of the radiologic diagnosis of central airway disease. This article introduces central airway imaging with MDCT emphasizing on the emerging role of multiplanar and 3D reconstruction.

Comparision of Mandible Changes on Three-Dimensional Computed Tomography image After Mandibular Surgery in Facial Asymmetry Patients (안면 비대칭 환자의 하악골 수술 후 하악골 변화에 대한 3차원 CT 영상 비교)

  • Kim, Mi-Ryoung;Chin, Byung-Rho
    • Journal of Yeungnam Medical Science
    • /
    • v.25 no.2
    • /
    • pp.108-116
    • /
    • 2008
  • Background : When surgeons plan mandible ortho surgery for patients with skeletal class III facial asymmetry, they must be consider the exact method of surgery for correction of the facial asymmetry. Three-dimensional (3D) CT imaging is efficient in depicting specific structures in the craniofacial area. It reproduces actual measurements by minimizing errors from patient movement and allows for image magnification. Due to the rapid development of digital image technology and the expansion of treatment range, rapid progress has been made in the study of three-dimensional facial skeleton analysis. The purpose of this study was to conduct 3D CT image comparisons of mandible changes after mandibular surgery in facial asymmetry patients. Materials & methods : This study included 7 patients who underwent 3D CT before and after correction of facial asymmetry in the oral and maxillofacial surgery department of Yeungnam University Hospital between August 2002 and November 2005. Patients included 2 males and 5 females, with ages ranging from 16 years to 30 years (average 21.4 years). Frontal CT images were obtained before and after surgery, and changes in mandible angle and length were measured. Results : When we compared the measurements obtained before and after mandibular surgery in facial asymmetry patients, correction of facial asymmetry was identified on the "after" images. The mean difference between the right and left mandibular angles before mandibular surgery was $7^{\circ}$, whereas after mandibular surgery it was $1.5^{\circ}$. The right and left mandibular length ratios subtracted from 1 was 0.114 before mandibular surgery, while it was 0.036 after mandibular surgery. The differences were analyzed using the nonparametric test and the Wilcoxon signed ranks test (p<0.05). Conclusion: The system that has been developed produces an accurate three-dimensional representation of the skull, upon which individualized surgery of the skull and jaws is easily performed. The system also permits accurate measurement and monitoring of postsurgical changes to the face and jaws through reproducible and noninvasive means.

  • PDF

The Significance of 3-Dimensional Imaging in Tracheal Stenosis (기관협착증에서 3차원적 영상 진단의 의의)

  • 정동학;봉정표;이운우;노정래;성기준
    • Korean Journal of Bronchoesophagology
    • /
    • v.1 no.1
    • /
    • pp.82-93
    • /
    • 1995
  • Three-dimensional reconstruction of computed tomographic image(3D CT) is a well-established imaging modality which has been investigated in various clinical settings. It is commonly performed in case of congenital or developmental abnormalities, and traumatic fracture of skull and face that requires reconstruction of osseous structure. However reporting the 3D CT in laryngeal or tracheal stenosis is rare and its results are obscure. The authors performed 3D CT in six cases of tracheal stenosis and found diagnostic value of 3D CT. A Comparision of diagnostic information obtained from plain X-ray, 2D CT and 3D CT has performed in total six cases of tracheal stenosis. Surgical treatment of the tracheal stenosis was following in these cases : tracheal end to end anastomosis In 1 case, laryngotracheal end to end anastomosis in 2 cases. 3D CT information was compared with operative finding. In two of six cases, satisfactory information was not obtained from 3D CT in evaluating an exact stenosis of trachea. Future, it will be helped in evaluating of tracheal stenosis by 3D CT.

  • PDF

The development of high fidelity Steam Generator three dimensional thermal hydraulic coupling code: STAF-CT

  • Zhao, Xiaohan;Wang, Mingjun;Wu, Ge;Zhang, Jing;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.763-775
    • /
    • 2021
  • The thermal hydraulic performances of Steam Generator (SG) under both steady and transient operation conditions are of great importance for the safety and economy in nuclear power plants. In this paper, based on our self-developed SG thermal hydraulic analysis code STAF (Steam-generator Thermalhydraulic Analysis code based on Fluent), an improved new version STAF-CT (fully Coupling and Transient) is developed and introduced. Compared with original STAF, the new version code STAF-CT has two main functional improvements including "Transient" and "Fully Three Dimensional Coupling" features. In STAF-CT, a three dimensional energy transferring module is established which can achieve energy exchange computing function at the corresponding position between two sides of SG. The STAF-CT is validated against the international benchmark experiment data and the results show great agreement. Then the U-shaped SG in AP1000 nuclear power plant is modeled and simulated using STAF-CT. The results show that three dimensional flow fields in the primary side make significant effect on the energy source distribution between two sides. The development of code STAF-CT in this paper can provide an effective method for further SG high fidelity research in the nuclear reactor system.

Arbitrary Cross Sectional Display from Three-dimensional Reconstructed Image by Hierarchical Model (계층적 모델에 의한 3차원 재구성 영상의 임의단면 표시)

  • 유선국;김선호
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.157-164
    • /
    • 1989
  • Three-dimensional imaging and manipulation of CT data are becoming increasingly important for deterRing the complex structure and pathologies. Octree which is a hierarchical data model is used to reconstruct three- dimensional objects from CT scans. Orthogonal cross sections are displayed by traverse the octree partially. Arbitrary oblique planes are derived by intersecting the square region of plane and cubic volume of octal node. Thia method enables the display of multi-structured complex organ ann the realization by personal computer.

  • PDF