• Title/Summary/Keyword: Thread Connection

Search Result 37, Processing Time 0.024 seconds

A IOCP-based Server for Product Information Management System of Small and Medium Size Manufacturing Companies (중소 제조업체의 생산정보 관리시스템을 위한 IOCP 기반 서버)

  • Rim, Seong-Rak;Song, Ki-Seok
    • Journal of Information Technology Applications and Management
    • /
    • v.14 no.4
    • /
    • pp.31-41
    • /
    • 2007
  • In order to keep global competitiveness, most of small and medium size manufacturing companies require to equip a product information management system which collects and analyzes the data generated at the manufacturing lines and then provides information for manager or worker to make a decision. However, these companies have a cost problem for adopting the enterprise resource planning system mostly used in large companies. To overcome this problem, we suggest an IOCP-based server for the product information management system suitable for small and medium size manufacturing companies. The basic concept of suggested server is that it is possible to process concurrently the connection requests coming from data collector and client by using the facility of asynchronous notification of OS and protect a server against overload by using the thread pool.

  • PDF

Complication incidence of two implant systems up to six years: a comparison between internal and external connection implants

  • Chae, Sung-Wook;Kim, Young-Sung;Lee, Yong-Moo;Kim, Won-Kyung;Lee, Young-Kyoo;Kim, Su-Hwan
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.1
    • /
    • pp.23-29
    • /
    • 2015
  • Purpose: This study was conducted to compare the cumulative survival rates (CSRs) and the incidence of postloading complications (PLCs) between a bone-level internal connection system (ICS-BL) and an external connection system (ECS). Methods: The medical records of patients treated with either a ICS-BL or ECS between 2007 and 2010 at Asan Medical Center were reviewed. PLCs were divided into two categories: biological and technical. Biological complications included >4 mm of probing pocket depth, thread exposure in radiographs, and soft tissue complications, whereas technical complications included chipping of the veneering material, fracture of the implant, fracture of the crown, loosening or fracture of the abutment or screw, loss of retention, and loss of access hole filling material. CSRs were determined by a life-table analysis and compared using the log-rank chi-square test. The incidence of PLC was compared with the Pearson chi-squared test. Results: A total of 2,651 implants in 1,074 patients (1,167 ICS-BLs in 551 patients and 1,484 ECSs in 523 patients) were analyzed. The average observation periods were 3.4 years for the ICS-BLs and 3.1 years for the ECSs. The six-year CSR of all implants was 96.1% (94.9% for the ICS-BLs and 97.1% for the ECSs, P=0.619). Soft tissue complications were more frequent with the ECSs (P=0.005) and loosening or fracture of the abutment or screw occurred more frequently with the ICS-BLs (P<0.001). Conclusions: Within the limitations of this study, the ICS-BL was more prone to technical complications while the ECS was more vulnerable to biological complications.

FIT OF FIXTURE/ABUTMENT INTERFACE OF INTERNAL CONNECTION IMPLANT SYSTEM (내측연결 임플란트 시스템에서 고정체와 지대주 연결부의 적합에 관한 연구)

  • Lee Heung-Tae;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.2
    • /
    • pp.192-209
    • /
    • 2004
  • Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combination or internal connection type. Material and methods: In this study, each two randomly selected internal implant fixtures from ITI, 3i, Avana, Bicon, Friadent, Astra, and Paragon system were used. Each abutment was connected to the implant with 32Ncm torque value using a digital torque controller or tapping. All samples were cross-sectioned with grinder-polisher unit (Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc). Then optical microscopic and scanning electron microscopic(SEM) evaluations of the implant-abutment interfaces were conducted to assess quality of fit between the mating components. Results : 1) Generally, the geometry of the internal connection system provided for a precision fit of the implant/abutment into interface. 2) The most precision fit of the implant/abutment interface was provided in the case of Bicon System which has not screw. 3) The fit of the implant/abutment interface was usually good in the case of ITI, 3I and Avana system and the amount of fit of the implant/abutment interface was similar to each other. 4) The fit of the implant/abutment interface was usually good in the case of Friadent, Astra and Paragon system. The case of Astra system with the inclined contacting surface had the most Intimate contact among them. 5) Amount of intimate contact in the abutment screw thread to the mating fixture was larger in assembly with two-piece type which is separated screw from abutment such as Friadent, Astra and Paragon system than in that with one-piece type which is not seperated screw from abutment such as ITI, 3I and Avana system. 6) Amount of contact in the screw and the screw seat of abutment was larger in assembly of Friadent system than in asembly of Astra system of Paragon system. Conclusion: Although a little variation in machining accuracy and consistency was noted in the samples, important features of all internal connection systems were the deep, internal implant-abutment connections which provides intimate contact with the implant walls to resist micro-movement, resulting in a strong stable interface. From the results of this study, further research of the stress distribution according to the design of internal connection system will be required.

Fluorescent Method for Observing Intravascular Bonghan Duct (형광염색을 이용한 혈관내봉한관의 관찰)

  • Lee, Byung-Cheon;Baik, Ku-Youn;Johng, Hyeon-Min;Sung, Baeck-Kyoung;Soh, Kyung-Soon;Kang, Dae-In;Soh, Kwang-Sup
    • Journal of Pharmacopuncture
    • /
    • v.8 no.3
    • /
    • pp.5-9
    • /
    • 2005
  • Observation of intra-vascular threadlike structures in the blood vessels of rats is reported with the images by differential interference contrast microscope, and fluorescence inverted microscope of the acridine-orange stained samples. The confocal microscope image and the hematoxylin-eosin staining revealed the distinctive pattern of nuclei distribution that clearly discerned the threadlike structure from fibrin, capillary, small venule, arteriole, or lymph vessel. Physiological function of the intra-vascular thread in connection with acupuncture is discussed. Especially, this threadlike duct can be a circulation path for herb-liquid flow, which may provide the scientific mechanism for therapeutic effect of herbal acupuncture.

Mobile Web Server Performance Improvement with Enhancing SOAP Message Transaction and NBTM (SOAP 메시지 처리 개선과 NBTM을 사용한 모바일 웹 서버의 성능 향상)

  • Kim, Young-Tae;Jeong, Yoon-Su;Park, Gil-Cheol;Lee, Sang-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.5
    • /
    • pp.135-142
    • /
    • 2008
  • Recently, the mobile Internet is rapidly changing environment in a user's web server performance requires frequent connection is difficult because the proper response is needed to improve the performance of web services engine. Therefore, the goal of this paper is to improve the performance of web services for the installation of additional access to users regardless of tomcat servlet container and process the request and to shorten processing time of SOAP (Simple Object Access Protocol) message of the server structure to of for web mobile services. The web-sever structure is consists of user demand receiver, web document processor, SOAP protocol processor, NBTM(Non-Blocking and Thread Manager) manager, session manager. The system fully supports a standard web-service protocol, reduces the message processing time and communication overhead of mobile web-service system in Web 2.0 and overhead of server, and confirms the improvement of capability by comparing and evaluating Web 2.0 standard mobile web-service system through delaying achievement evaluation by the experiment of realization in Web 2.0 environment.

  • PDF

Evaluation of Bearing Strength of Self-Tapping Screws according to the Grain Direction of Domestic Pinus densiflora

  • LEE, In-Hwan;KIM, Keonho;SHIM, Kug-bo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.50 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • To evaluate the bearing strength of red pine cross-laminated timber (CLT) with self-tapping screw (STS), which is widely used as a fastener for connection in CLT building, the bearing test was conducted. Accoring to the STS's diameters (8, 10, 12 mm), the bearing test specimens with half hole were manufactured. Bearing strength was compared and reviewed in consideration of the configuration in STS and the loading direction to the grain of red pine. As a result of the bearing test on the STS's diameter, the yield bearing load increases as the larger diameter of the STS in all directions of the red pine. The bearing strength of the thread part (thread + tip) was higher than the shank part (shank + shank cutter). In compared with the directions to the grain of red pine, the bearing strength of the cross section parallel to the loading direction was the highest, and the tangent section was the lowest bearing strength. The average bearing strength of the loading direction in parallel to the grain was 23.43 MPa, which was about 45% higher than the average 16.16 MPa in perpendicular to the grain. The predicted bearing strength calculated by Eurocode (EN) and Korean Building Code (KBC)'s equation was lower than the experimental value. It is nessesary to propose the new equations of bearing strength reflected the configuration information of STS.

Finite Element Stress Analysis of Bone Tissue According to the Implant Connection Type (2종의 임플란트 내부결합구조체에 따른 치조골상 유한요소응력 분석)

  • Byun, Ook;Jung, Da-Un;Han, In-Hae;Kim, Seong-Ryang;Lee, Chang-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.259-271
    • /
    • 2013
  • The purpose of this study was to make the stress distribution produced by simulated different load under two types of internal connection implant system (stepped and tapered type) by means of 3D finite element analysis, The finite element model was designed with the parallel placement of the one fixtures ($4.0mm{\times}11.5mm$) with reverse buttress thread on the mandibular 1st molar. Two models were loaded with 200 N magnitude in the vertical direction on the central position of the crown, the 1.5 mm and 3 mm buccal offset point from the central position of the fixture. The oblique load was applied at the angle of $30^{\circ}$ on the crown surface. Von Mises stress value was recorded and compared in the fixture-bone interface in the bucco-lingual dimension. The results were as follows; 1. The loading conditions of two internal connection implant systems (stepped and tapered type) were the main factor affecting the equivalent bone strain, followed by the type of internal connections. 2. The stepped model had more mechanical stability with the reduced max. stress compared to $11^{\circ}$ tapered models under the distributed oblique loading. 3. The more the contact of implant-abutment interface to the inner wall of implant fixture, the less stress concentration was reduced.

The current status of dental dispute: Centered on the 2nd data(Korea Consumer Agency, Med-in) (2차 자료(한국소비자원, 현대해상화재 배상보험)에 나타난 치과의료분쟁 현황)

  • Ahn, Yong Soon;Ahn, Eun Suk;Goong, Hwa-Soo
    • The Journal of the Korean dental association
    • /
    • v.53 no.2
    • /
    • pp.96-102
    • /
    • 2015
  • There is a need to comprehend dental accidents accurately, and construct patient-safety-system in order to prevent consistently increasing dental accident or dispute. This study is aimed to provide basic data for an efficient counterplain by looking through and classifying already occurred dental accidents from an angle of patient safety. Recently, the number of dispute on dental implant was the highest according to rapid growth of dental implant. As a result of classifying dental accidents by International Classification for Patient Safety (ICPS), it is confirmed that cause of accident is different by each type of dental treatment. It is expected to help preventing and managing dental disputes properly by studying actual state of dental disputes in perspective of patient safety. Effort to reduce dental accidents and activity to pursue patient safety have thread in connection. I believe that financial profits of dental clinic and improvement of quality in dental treatment can be achieved through these efforts.

State-Monitoring Component-based Fault-tolerance Techniques for OPRoS Framework (상태감시컴포넌트를 사용한 OPRoS 프레임워크의 고장감내 기법)

  • Ahn, Hee-June;Ahn, Sang-Chul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.8
    • /
    • pp.780-785
    • /
    • 2010
  • The OPRoS (Open Platform for Robotic Services) framework is proposed as an application runtime environment for service robot systems. For the successful deployment of the OPRoS framework, fault tolerance support is crucial on top of its basic functionalities of lifecycle, thread and connection management. In the previous work [1] on OPRoS fault tolerance supports, we presented a framework-based fault tolerance architecture. In this paper, we extend the architecture with component-based fault tolerance techniques, which can provide more simplicity and efficiency than the pure framework-based approach. This argument is especially true for fault detection, since most faults and failure can be defined when the system cannot meet the requirement of the application functions. Specifically, the paper applies two widely-used fault detection techniques to the OPRoS framework: 'bridge component' and 'process model' component techniques for fault detection. The application details and performance of the proposed techniques are demonstrated by the same application scenario in [1]. The combination of component-based techniques with the framework-based architecture would improve the reliability of robot systems using the OPRoS framework.

A Text Linguistic Approach to the Chapter Hoyeonjigi of Mencius ("맹자" "호연지기 장"의 텍스트언어학적 접근)

  • 이석규
    • Lingua Humanitatis
    • /
    • v.5
    • /
    • pp.127-163
    • /
    • 2003
  • This thesis analyzes the Chapter "Hoyeonjigi(浩然之氣)" of Mencius(孟子), using text linguistics theory and reading theory of Korean. In this process the model of macro-structure #1∼5 are presented, according to Vandijk′s rules of macro-structure; Auslassen, Selektierne, Generalisieren, Konstruieren odor Integrieren. As a result, this certifies; First, macro-structure could make arbitrarily a several steps of macro-structure by types of text or purpose of analysis. Second, macro-structure applies various cognitive mechanisms of outer world as well as inner world. Third, a text with profound symbolism could be figured as a two-or threefolded symbolic structure. At the same time, macro-structure enables the clearer analysis of the content of the Chapter to verify the following; first, Hoyeinjigi itself is the best measure of developing "Imperturbable Mind(不動心)" Second, benevolence-righteousness(仁義) and wisdom(智) would be reached by cultivating Hoyeonjigi. Third, Mencius′ own view of language is well expressed in "Jieon(知言)", which is not only a condition for Imperturbable Mind, but also the Oriental view of language focused especially on listening in terms of language usage, not language analysis. This Mencius′ view of language has a thread connection with that of Oriental′s.

  • PDF