• 제목/요약/키워드: Thread Connection

검색결과 37건 처리시간 0.023초

중소 제조업체의 생산정보 관리시스템을 위한 IOCP 기반 서버 (A IOCP-based Server for Product Information Management System of Small and Medium Size Manufacturing Companies)

  • 임성락;송기석
    • Journal of Information Technology Applications and Management
    • /
    • 제14권4호
    • /
    • pp.31-41
    • /
    • 2007
  • In order to keep global competitiveness, most of small and medium size manufacturing companies require to equip a product information management system which collects and analyzes the data generated at the manufacturing lines and then provides information for manager or worker to make a decision. However, these companies have a cost problem for adopting the enterprise resource planning system mostly used in large companies. To overcome this problem, we suggest an IOCP-based server for the product information management system suitable for small and medium size manufacturing companies. The basic concept of suggested server is that it is possible to process concurrently the connection requests coming from data collector and client by using the facility of asynchronous notification of OS and protect a server against overload by using the thread pool.

  • PDF

Complication incidence of two implant systems up to six years: a comparison between internal and external connection implants

  • Chae, Sung-Wook;Kim, Young-Sung;Lee, Yong-Moo;Kim, Won-Kyung;Lee, Young-Kyoo;Kim, Su-Hwan
    • Journal of Periodontal and Implant Science
    • /
    • 제45권1호
    • /
    • pp.23-29
    • /
    • 2015
  • Purpose: This study was conducted to compare the cumulative survival rates (CSRs) and the incidence of postloading complications (PLCs) between a bone-level internal connection system (ICS-BL) and an external connection system (ECS). Methods: The medical records of patients treated with either a ICS-BL or ECS between 2007 and 2010 at Asan Medical Center were reviewed. PLCs were divided into two categories: biological and technical. Biological complications included >4 mm of probing pocket depth, thread exposure in radiographs, and soft tissue complications, whereas technical complications included chipping of the veneering material, fracture of the implant, fracture of the crown, loosening or fracture of the abutment or screw, loss of retention, and loss of access hole filling material. CSRs were determined by a life-table analysis and compared using the log-rank chi-square test. The incidence of PLC was compared with the Pearson chi-squared test. Results: A total of 2,651 implants in 1,074 patients (1,167 ICS-BLs in 551 patients and 1,484 ECSs in 523 patients) were analyzed. The average observation periods were 3.4 years for the ICS-BLs and 3.1 years for the ECSs. The six-year CSR of all implants was 96.1% (94.9% for the ICS-BLs and 97.1% for the ECSs, P=0.619). Soft tissue complications were more frequent with the ECSs (P=0.005) and loosening or fracture of the abutment or screw occurred more frequently with the ICS-BLs (P<0.001). Conclusions: Within the limitations of this study, the ICS-BL was more prone to technical complications while the ECS was more vulnerable to biological complications.

내측연결 임플란트 시스템에서 고정체와 지대주 연결부의 적합에 관한 연구 (FIT OF FIXTURE/ABUTMENT INTERFACE OF INTERNAL CONNECTION IMPLANT SYSTEM)

  • 이흥태;정재헌
    • 대한치과보철학회지
    • /
    • 제42권2호
    • /
    • pp.192-209
    • /
    • 2004
  • Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combination or internal connection type. Material and methods: In this study, each two randomly selected internal implant fixtures from ITI, 3i, Avana, Bicon, Friadent, Astra, and Paragon system were used. Each abutment was connected to the implant with 32Ncm torque value using a digital torque controller or tapping. All samples were cross-sectioned with grinder-polisher unit (Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc). Then optical microscopic and scanning electron microscopic(SEM) evaluations of the implant-abutment interfaces were conducted to assess quality of fit between the mating components. Results : 1) Generally, the geometry of the internal connection system provided for a precision fit of the implant/abutment into interface. 2) The most precision fit of the implant/abutment interface was provided in the case of Bicon System which has not screw. 3) The fit of the implant/abutment interface was usually good in the case of ITI, 3I and Avana system and the amount of fit of the implant/abutment interface was similar to each other. 4) The fit of the implant/abutment interface was usually good in the case of Friadent, Astra and Paragon system. The case of Astra system with the inclined contacting surface had the most Intimate contact among them. 5) Amount of intimate contact in the abutment screw thread to the mating fixture was larger in assembly with two-piece type which is separated screw from abutment such as Friadent, Astra and Paragon system than in that with one-piece type which is not seperated screw from abutment such as ITI, 3I and Avana system. 6) Amount of contact in the screw and the screw seat of abutment was larger in assembly of Friadent system than in asembly of Astra system of Paragon system. Conclusion: Although a little variation in machining accuracy and consistency was noted in the samples, important features of all internal connection systems were the deep, internal implant-abutment connections which provides intimate contact with the implant walls to resist micro-movement, resulting in a strong stable interface. From the results of this study, further research of the stress distribution according to the design of internal connection system will be required.

형광염색을 이용한 혈관내봉한관의 관찰 (Fluorescent Method for Observing Intravascular Bonghan Duct)

  • 이병천;백구연;정현민;성백경;소경순;강대인;소광섭
    • 대한약침학회지
    • /
    • 제8권3호
    • /
    • pp.5-9
    • /
    • 2005
  • 미분간섭현미경법과 아크리딘-오렌지(acridine-orange) 형광 염색을 이용하여 쥐 혈관 내의 실 모양 구조물을 관찰하였다. 공초점현미경법과 헤마톡실린-에오신(hematoxylin-eosin) 염색을 통해 피브린, 모세혈관, 소정맥, 소동맥 혹은 림프관의 핵 분포와 뚜렷이 구별되는 혈관 내 실 모양 구조물의 핵 분포 패턴을 얻어낼 수 있었다. 이 실 모양 구조물의 생리적 기능을 침술과 연관하여 논의하였다. 특히, 이 실 모양 관을 통한 약물의 흐름이 약침의 기전에 해당할 것이라는 가설을 제기하였다.

SOAP 메시지 처리 개선과 NBTM을 사용한 모바일 웹 서버의 성능 향상 (Mobile Web Server Performance Improvement with Enhancing SOAP Message Transaction and NBTM)

  • 김용태;정윤수;박길철;이상호
    • 한국컴퓨터정보학회논문지
    • /
    • 제13권5호
    • /
    • pp.135-142
    • /
    • 2008
  • 최근의 급속하게 변화하는 모바일 인터넷 환경에서 이전의 웹 서버 성능으로는 사용자의 빈번한 연결 요구에 대해 적절한 대응이 어렵기 때문에 웹 서비스 엔진의 성능 향상이 필요하다. 따라서 본 논문은 웹 서비스의 성능 향상을 위해서 부가적으로 설치하는 톰캣 서블릿 컨테이너와 무관하게 사용자의 접속 요청을 처리하고, SOAP(Simple Object Access Protocol) 메시지 처리 시간을 단축하는 모바일 웹 서비스의 서버 구조를 제안한다. 제안한 웹 서버 구조는 사용자요구 수신기, 웹 문서 처리기, SOAP 프로토콜 처리기, NBTM(Non-Blocking and Thread Manager) 관리자, 세션 관리자로 구성한다. 제안된 시스템은 표준 램 서비스 프로토콜을 완전하게 지원하고, 웹2.0의 모바일 웹서비스 시스템의 통신 오버헤드와 메시지 처리 시간, 서버의 오버헤드를 감소하며, 웹2.0 환경에서 구현 실험을 통한 지연 수행 평가에 의해서 웹2.0표준 모바일 웹 서비스 시스템과 성능을 비교, 평가하여 성능 향상을 확인하였다.

  • PDF

Evaluation of Bearing Strength of Self-Tapping Screws according to the Grain Direction of Domestic Pinus densiflora

  • LEE, In-Hwan;KIM, Keonho;SHIM, Kug-bo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제50권1호
    • /
    • pp.1-11
    • /
    • 2022
  • To evaluate the bearing strength of red pine cross-laminated timber (CLT) with self-tapping screw (STS), which is widely used as a fastener for connection in CLT building, the bearing test was conducted. Accoring to the STS's diameters (8, 10, 12 mm), the bearing test specimens with half hole were manufactured. Bearing strength was compared and reviewed in consideration of the configuration in STS and the loading direction to the grain of red pine. As a result of the bearing test on the STS's diameter, the yield bearing load increases as the larger diameter of the STS in all directions of the red pine. The bearing strength of the thread part (thread + tip) was higher than the shank part (shank + shank cutter). In compared with the directions to the grain of red pine, the bearing strength of the cross section parallel to the loading direction was the highest, and the tangent section was the lowest bearing strength. The average bearing strength of the loading direction in parallel to the grain was 23.43 MPa, which was about 45% higher than the average 16.16 MPa in perpendicular to the grain. The predicted bearing strength calculated by Eurocode (EN) and Korean Building Code (KBC)'s equation was lower than the experimental value. It is nessesary to propose the new equations of bearing strength reflected the configuration information of STS.

2종의 임플란트 내부결합구조체에 따른 치조골상 유한요소응력 분석 (Finite Element Stress Analysis of Bone Tissue According to the Implant Connection Type)

  • 변욱;정다운;한인혜;김성량;이창희
    • 구강회복응용과학지
    • /
    • 제29권3호
    • /
    • pp.259-271
    • /
    • 2013
  • 임플란트 고정체-지대주 결합구조체의 형태에 따른 교합부하의 반응이 다양하여 본 연구에서는 하중위치 및 결합구조체 접촉 비율에 따라 3단 계단형 결합구조체와 경사형에서 어떠한 차이가 있는 지를 3차원 유한요소분석을 시행하였다. 2종의 임플란트-지대주 결합 구조체에 연결된 상부 치관을 제작하여 각 치관에 설정된 하중위치에 200 N의 하중을 부여하였다. 임플란트 중심 부위에서 하중조건이 멀어질수록 피질골정에 가해지는 응력이 증가되기에 하중조건은 응력발생에 영향을 미치는 주요 요소이며 다음으로 결합구조형태에도 영향을 받았다. 또한 수직 하중에 비해 빗금 경사 하중이 부여된 경우 계단형은 경사형에 비해 유리한 응력 분포를 보였다. 그리고 지대주 결합구조체가 고정체의 내벽에 대해 접촉이 많아 질수록 골질에 대한 응력분산이 유리한 것으로 나타났다. 결론적으로 고정체 폭경에서 벗어난 빗김 수직 및 경사 하중은 결합구조체의 종류와 관계없이 피질골정에 응력을 집중시키므로 저작기능시 교합접촉면을 고정체의 폭경 내에 위치하도록 하는 것이 생체역학적으로 바람직 할 것으로 사료되었다.

2차 자료(한국소비자원, 현대해상화재 배상보험)에 나타난 치과의료분쟁 현황 (The current status of dental dispute: Centered on the 2nd data(Korea Consumer Agency, Med-in))

  • 안용순;안은숙;궁화수
    • 대한치과의사협회지
    • /
    • 제53권2호
    • /
    • pp.96-102
    • /
    • 2015
  • There is a need to comprehend dental accidents accurately, and construct patient-safety-system in order to prevent consistently increasing dental accident or dispute. This study is aimed to provide basic data for an efficient counterplain by looking through and classifying already occurred dental accidents from an angle of patient safety. Recently, the number of dispute on dental implant was the highest according to rapid growth of dental implant. As a result of classifying dental accidents by International Classification for Patient Safety (ICPS), it is confirmed that cause of accident is different by each type of dental treatment. It is expected to help preventing and managing dental disputes properly by studying actual state of dental disputes in perspective of patient safety. Effort to reduce dental accidents and activity to pursue patient safety have thread in connection. I believe that financial profits of dental clinic and improvement of quality in dental treatment can be achieved through these efforts.

상태감시컴포넌트를 사용한 OPRoS 프레임워크의 고장감내 기법 (State-Monitoring Component-based Fault-tolerance Techniques for OPRoS Framework)

  • 안희준;안상철
    • 제어로봇시스템학회논문지
    • /
    • 제16권8호
    • /
    • pp.780-785
    • /
    • 2010
  • The OPRoS (Open Platform for Robotic Services) framework is proposed as an application runtime environment for service robot systems. For the successful deployment of the OPRoS framework, fault tolerance support is crucial on top of its basic functionalities of lifecycle, thread and connection management. In the previous work [1] on OPRoS fault tolerance supports, we presented a framework-based fault tolerance architecture. In this paper, we extend the architecture with component-based fault tolerance techniques, which can provide more simplicity and efficiency than the pure framework-based approach. This argument is especially true for fault detection, since most faults and failure can be defined when the system cannot meet the requirement of the application functions. Specifically, the paper applies two widely-used fault detection techniques to the OPRoS framework: 'bridge component' and 'process model' component techniques for fault detection. The application details and performance of the proposed techniques are demonstrated by the same application scenario in [1]. The combination of component-based techniques with the framework-based architecture would improve the reliability of robot systems using the OPRoS framework.

"맹자" "호연지기 장"의 텍스트언어학적 접근 (A Text Linguistic Approach to the Chapter Hoyeonjigi of Mencius)

  • 이석규
    • 인문언어
    • /
    • 제5권
    • /
    • pp.127-163
    • /
    • 2003
  • This thesis analyzes the Chapter "Hoyeonjigi(浩然之氣)" of Mencius(孟子), using text linguistics theory and reading theory of Korean. In this process the model of macro-structure #1∼5 are presented, according to Vandijk′s rules of macro-structure; Auslassen, Selektierne, Generalisieren, Konstruieren odor Integrieren. As a result, this certifies; First, macro-structure could make arbitrarily a several steps of macro-structure by types of text or purpose of analysis. Second, macro-structure applies various cognitive mechanisms of outer world as well as inner world. Third, a text with profound symbolism could be figured as a two-or threefolded symbolic structure. At the same time, macro-structure enables the clearer analysis of the content of the Chapter to verify the following; first, Hoyeinjigi itself is the best measure of developing "Imperturbable Mind(不動心)" Second, benevolence-righteousness(仁義) and wisdom(智) would be reached by cultivating Hoyeonjigi. Third, Mencius′ own view of language is well expressed in "Jieon(知言)", which is not only a condition for Imperturbable Mind, but also the Oriental view of language focused especially on listening in terms of language usage, not language analysis. This Mencius′ view of language has a thread connection with that of Oriental′s.

  • PDF