• Title/Summary/Keyword: Thorax

Search Result 393, Processing Time 0.042 seconds

The Experimental Study for the Balanced Restoration on the part of Spinal Skeletal Muscles in Low Back Pain Patients - By Acupuncture Stimuli Model of Limb Skeletal Muscle - (요통환자의 척주골격근 균형회복을 위한 실증적 연구 - 사지골격근의 침 자극모형을 중심으로 -)

  • Moon, Sang-Eun;Lee, Cheon-Bok
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.1
    • /
    • pp.907-915
    • /
    • 2001
  • The purpose of this study is to effectively treat low back pain for the out patients who have been treated at the oriental hospital. Sorting the low back pain patients into four types based on scapular and ilium tilting hyper/hypo mobility characteristics, it has used several kinds of acupuncture stimuli on the 4 motor points of limb skeletal muscles, analyzing the acupuncture treatment on the 12 acupuncture points with which oriental hospitals has given to the low back pain patients and comparing with this effect. It has been analyzed how effectively the acupuncture stimuli has been contributed to the low back pain patients who suffered from skeletal muscles of spinal limb thorax abdominal and spinal skeletal system. The results are as follows. 1. There has been changes after treatment in both the control and experimental groups for low back pain patients, but the latter has been more increased in changes than the former. 2. There were much effects on the balanced restorations for spinal skeletal muscle in both the control group and experimental one, but on terms of restoration degree, the degree of the experimental group was higher than that of the control group. 3. Both the contrastive treatment and the experimental one have been contributed to the balanced restoration for all of the limb thorax abdominal muscles, but there were a few differences in terms of the way for restoration and the effects for improvement according to body types. 4. On both the control and the experimental group, spinal skeletal system has been restored with balance, but the experimental group has been higher effective on the balanced restoration than the one of the control group. Considering these results both the control and the experimental treatments have been contributed to the balanced restorations for all of low back pain patients who were suffering from skeletal muscles of spinal limb thorax abdominal and spinal skeletal system, but the contribution degree for the experimental group has been higher than that of the control group.

  • PDF

Extravasation Injury of Contrast Media in the Neck and Thorax During MDCT Scanning with 3D Image Reformation Findings (CT검사에서 조영제의 혈관외유출에 의한 목 및 흉부 손상의 3차원 재구성 영상)

  • Kweon, Dae-Cheol;Jang, Keun-Jo;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.281-287
    • /
    • 2007
  • Contrast media may cause tissue injury by extravasation during intravenous automated injection during CT examination. Here, we present a study in which contrast media extravasation was detected and localized in the neck and thorax by three-dimensional(3D) CT data reformation. The CT studies of the extavasation site were performed using a 3D software program with four different display techniques axial, multi planar reformation(MPR), maximum intensity projection(MIP), and volume rendering displays are currently available for reconstructing MDCT data. 3D image reconstructions provide accurate views of high-resolution imaging. This paper introduces extravasation with the MDCT and 3D reformation findings of contrast media extravasation in neck ant thorax. The followed injection of the external jugular vein into an existing intravenous catheter and a large volume of extravasation was demonstrated on by 3D MDCT.

  • PDF

Radiation Dose Comparison according to Different Organ Characteristics at Same Scan Parameters Using CareDose 4D: An Adult and Pediatric Phantom Evaluation (CareDose 4D 사용 시 동일한 스캔조건에서 조직기반설정을 다르게 적용함에 따른 선량 비교: 성인과 소아팬텀 연구)

  • Kong, Hyo-Geum;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.271-277
    • /
    • 2019
  • CareDose 4D which is the Siemens's Automatic Exposure Control (AEC) can adjust the level of radiation dose distribution which is based on organ characteristic unlike other manufacturer's AEC. Currently, a wide scan range containing different organs is sometimes examined at once (defined as one scan). The purpose of this study was to figure out which organ characteristic option is suitable when one scan method is utilized. Two types of anthropomorphic phantoms were scanned in the same range which were from frontal bone to carina level according to three different organ characteristics such as Thorax, Abdomen, and Neck. All scans and image reconstruction parameters were equally applied and radiation dose were compared. Radiation dose with Thorax organ characteristic was lower than that with Neck. Also, that with Abdomen oran characteristic was lower than Thorax. There were significant differences in radiation dose according to different organ characteristics at the same parameters (P<0.05). Usage of Neck organ characteristic had a result of the highest radiation dose to all phantom. On the other hand, utilization of Abdomen organ characteristic showed the lowest radiation dose. As a result, it is desirable to set appropriate organ characteristic according to examined body part when you checkup patients. Also, when you implement one scan method, selection of Abdomen-based organ characteristic has reduced more radiation dose compared with two different organ characteristic.

Absorbed Dose and Effective Dose for Lung Cancer Image Guided Radiation Therapy(IGRT) using CBCT and 4D-CBCT (폐암 영상유도방사선 치료 시 CBCT와 4D-CBCT를 이용한 흡수선량 및 유효선량에 관한 선량 평가)

  • Kim, Dae yong;Lee, Woo Suk;Koo, Ki Lae;Kim, Joo Seob;Lee, Sang Hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.57-64
    • /
    • 2016
  • Purpose : To evaluate the results of absorbed and effective doses using CBCT and 4D-CBCT settings for lung cancer. Materials and Methods : This experimental study. Measurements were performed using a Anderson rando phantom with OSLD(optically stimulated luminescent dosimeters). It was performed computed tomography(Lightspeed GE, USA) in order to express the major organs of the human body. Measurements were obtained a mean value is repeated three times each. Evaluations of effective dose and absorbed dose were performed the CL-IX-Thorax mode and Truebeam-Thorax mode CBCT. Additionally, compared Truebeam-Thorax mode CBCT with Truebeam-Thorax mode 4D-CBCT(Four-dimensional Cone Beam Computed Tomography) Results : Average absorbed dose in the CBCT of CL-IX was measured in lung 2.505cGy, heart 2.595cGy, liver 2.145cGy, stomach 1.934cGy, skin 2.233cGy, in case of Truebeam, It was measured lung 1.725cGy, heart 2.034cGy, liver 1.616cGy, stomach 1.470cGy, skin 1.445cGy. In case of 4D-CBCT, It was measured lung 3.849cGy, heart 4.578cGy, liver 3.497cGy, stomach 3.179cGy, skin 3.319cGy Average effective dose, considered tissue weighting and radiation weighting, in the CBCT of CL-IX was measured lung 2.164mSv, heart 2.241mSVv, liver 0.136mSv, stomach 1.668mSv, skin 0.009mSv, in case of Turebeam, it was measured lung 1.725mSv, heart 1.757mSv, liver 0.102mSv, stomach 1.270mSv, skin 0.005mSv, In case of 4D-CBCT, It was measured lung 3.326mSv, heart 3.952mSv, liver 0.223mSv, stomach 2.747mSv, skin 0.013mSv Conclusion : As a result, absorbed dose and effective Dose in the CL-IX than Truebeam was higher about 1.3 times and in the 4D-CBCT Truebeam than CBCT of Truebeam was higher about 2.2times However, a large movement of the patient and respiratory gated radiotherapy may be more accurate treatment in 4D-CBCT. Therefore, it will be appropriate to selectively used.

  • PDF

Employing Magnetic Resonance Imaging(MRI) in the Estimation of the Biomechanical Body Segment Parameters of Korean Adults (MRI에 의한 한국인 신체분절의 생체역학적 모수치 산출)

  • Joo, Young-Hwa
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.1
    • /
    • pp.233-249
    • /
    • 2002
  • The purpose of this study was to employing MRI in the estimation of the biomechanical body segment parameters of Korean adults. for this purpose MRI study on 19 Korean living subjects were used to measurement. All the parameters that was concerned were inertial characteristics of human body mass of each segment, center of mass of them and the length of radius of gyration of them. The cross sectional images and saggital images of every 1cm interval were got using the 0.5 Tesla MRI from the top of head to the bottom of foot, whole body. And then, by tracing the images of the film and scanning them, got the area which the several tissues occupied in the image of slice. By summing the area of slice of each segment which were calculating and by multipling the density of the tissues, got the mass of segment and other inertial characteristics. The ratios of radius of gyration in both transverse axis and longitudinal axis though the segmental mass and segment length are as follow: male A : head($0.229\pm0.0029$), neck($0.256\pm0.0095$), thorax($0.374\pm0.0059$) abdomen($0.245\pm0.0020$), pelvis($0.368\pm0.0106$), thigh($0.288\pm0.0030$) shank($0.280\pm0.0043$), foot($0.277\pm0.0195$), upperarm($0.311\pm0.0074$) forearm($0.286\pm0.0051$), hand($0.253\pm0.0095$) female A : head($0.214\pm0.0032$), neck($0.254\pm0.0112$), thorax($0.295\pm0.0061$) abdomen($0.289\pm0.0021$), pelvis($0.329\pm0.0108$), thigh($0.288\pm0.0036$) shank($0.280\pm0.0047$), foot($0.243\pm0.0206$), upperarm($0.279\pm0.0083$) forearm($0.286\pm0.0048$), hand($0.229\pm0.0097$) male B : head($0.532\pm0.0006$), neck($0.533\pm0.0006$), thorax($0.658\pm0.0008$) abdomen($1.350\pm0.0022$), pelvis($0.875\pm0.0002$), thigh($0.213\pm0.0001$) shank($0.160\pm0.0001$), foot($0.152\pm0.0002$), upperarm($0.136\pm0.0002$) forearm($0.202\pm0.0002$), hand($0.273\pm0.0006$) female B : head($0.198\pm0.0002$), neck($0.335\pm0.0011$), thorax($0.238\pm0.0001$) abdomen($0.888\pm0.0001$), pelvis($1.318\pm0.0117$), thigh($0.095\pm0.0001$) shank($0.075\pm0.0001$), foot($0.181\pm0.0006$), upperarm($0.0.062\pm0.0001$) forearm($0.083\pm0.0001$), hand($0.105\pm0.0007$).

The education evaluation of basic CPR on middle school students (중학교 재학생의 기본 심폐소생술 교육 효과 평가)

  • Kim, Youl
    • The Korean Journal of Emergency Medical Services
    • /
    • v.10 no.1
    • /
    • pp.71-77
    • /
    • 2006
  • This study is focused on middle school students who are composed of a factor in medical emergency system. In the case of cardiac failure, it is to make its basic data and develop its education program of CPR(cardiopulmonary resuscitation) which can increase the patient's survival rate before his hospitalization. The findings of this study is as follows. The subject of study is composed of 117 persons who are 54 boy-students(46.2%) and 63 girl-students(53.8%) in sex and 72 first-grade students(61.5%) and 45 second-grade students (38.5%) in a school year. In the accuracy degree, the practice of artificial respiration is $42.28{\pm}34.42%$ in case of basic CPR(cardiopulmonary resuscitation). The accuracy degree of the thorax pressure is $82.17{\pm}15.40%.$ In the accuracy degree, the practice of artificial respiration is $92.16{\pm}25.68%$ in boy-students and $20.38{\pm}24.16%$ in girl-students, the second-grade students is $58.40{\pm}33.29%$, which is higher than the first-grade students' $32.21{\pm}31.14%$. In the accuracy degree, the thorax pressure is $92.16{\pm}3.91%$ in boy-studetns and $73.61{\pm}16.41%$ in girl-students. In the accuracy degree of the thorax pressure, the second-grade students are $82.60{\pm}16.54%$ and the first-grade students $81.91{\pm}3.91$, which doesn't show any significant difference in school year. The satisfaction degree after theory & practice education is $2.12{\pm}.85$. In the satisfaction degree of its basic CPR, girl-students are $2.14{\pm}.83$ and boy-students are 2.11. In the satisfaction degree of its basic CPR, the second-grade students are $2.40{\pm}.61$ and the first-grade students are $1.95{\pm}.94$. This study is to lead to some suggestions. First, it is necessary to develop the education program and educate its knowledge & technology in proportion to student's characteristics of sex and school year. Second, education authorities should develop a subject of the accident prevention and first-aid treatment in its curriculum and provide the practical education of CPR for adults, adolescents and children. Third, it is necessary to study the education program as well as the education evaluation of CPR further on.

  • PDF

Assessment of Isokinetic Muscle Function in Elite Canadian College Paddlers (대학 엘리트 카나디언 선수들의 어깨·허리·무릎 관절의 등속성 근기능 평가 및 진단)

  • Shin, Kwang-Taek;An, Chang-Gyu;Sohn, Jee-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.229-238
    • /
    • 2013
  • The aim of this study is to evaluate university canadian paddlers' iso-kinetic muscle function and provide training advices. Eight university paddlers with a 8.5 years career participated in this study. Inbody 720, biodex system III, biodex stabilizer system and THP 2 are used to investigate body component, muscle function(peak torque, average power and work fatigue), agility and dynamic balance. Iso-kinetic muscle function around shoulder, thorax and knee are measured. And then bilateral and unilateral muscle imbalance are calculated at each joint. Results of this study are as follows; University canadian paddlers' BMI average is 24.90 $kg/m^2$ and percent body fat is 12.23%. Reaction time average was 324 msec and balance score at each leg are below 2.0. A3, A4, A5, A6, A8 are needed to train shoulder muscle strength and power. A1, A2, A7, A8 are needed to strengthen shoulder muscle endurance. A2, A5, A8 are needed to train thorax muscle strength and power. A1, A8 are needed to strengthen thorax muscle endurance. Most of paddlers' reciprocal muscle balance ratio on thorax and knee are out of normal range. A2, A3, A4, A8 are needed to train abdominal strength and A3, A5, A6, A7, A8 are needed to train hamstring strength.

Surgical Treatment of Bronchogenic Cyst -A Report of 7 cases- (기관지성 낭종의 외과적 치료 -7례 보고-)

  • 김창수
    • Journal of Chest Surgery
    • /
    • v.23 no.3
    • /
    • pp.605-608
    • /
    • 1990
  • Bronchogenic cyst is a congenital cystic lesion which is usually found within the lung parenchyme or mediasitnum. Since the surgical removal of asymptomatic lesions was adopted as the reasonable therapeutic principle and increased use of roentgenograms of the thorax, many more cases of bronchogenic cysts are being observed. Seven cases of bronchogenic cysts were presented and related literatures were reviewed.

  • PDF

A Case Report on the Traumatic Pneumothorax associated with Acupuncture (자침과 관련된 외상성 기흉 1례)

  • Lee, Sang-Hoon;Choi, Do-Young;Lee, Yun-Ho
    • Journal of Acupuncture Research
    • /
    • v.18 no.4
    • /
    • pp.205-211
    • /
    • 2001
  • Objective : There was no report on traumatic pneumothorax associated with acupuncture in korea yet, although many people guess at its possibility. In order to make known that acupuncture can cause pneumothorax in reality and to prevent more acupuncture-related adverse effect cases in future, this report was made. Methods : Close observation was done on clinical symptoms & radiologic examination of acupuncture-related traumatic pneumothorax patient. Results : During acupuncture therapy on neck stiffness & shoulder pain, a acupuncture needle was inserted too deeply into upper part of thorax unintentionally, patient showed dyspnea, chest pain & discomfort, cough, sweating and mild rupture of right lung in chest radiologic findings, and recovered after 2 weeks of conservative treatment. Conclusion : In order to prevent traumatic pneumothorax during acupuncture therapy, needling into thorax sometimes requires tilted acupuncture needle inserting under consideration of needle width & length. At least 0.40mm width of needle is generally considered appropriate in needling into taut band of thoracic muscles, because too thin and long needle sometimes can be bent and inserted into wrong way, which can cause adverse effects like pneumothorax.

  • PDF

Quantitative analysis of hemothorax by computed tomography (흉부 전산화 단층촬영을 이용한 혈흉의 정량분석)

  • 강청희
    • Journal of Chest Surgery
    • /
    • v.28 no.3
    • /
    • pp.228-232
    • /
    • 1995
  • Computed tomography[CT is an effective technique for the evaluation of the thorax following blunt trauma. To evaluate multiply injured 30 patients who were diagnosed as hemothorax in emergency room, computed tomography of thorax was done. The thickness of slice was one centimeter and the entire pleural cavity from the apex to the costophrenic angle was included in the evaluation. Integration and addition of the hemothorax area for each CT slice was made and amount of blood in the pleural cavity was estimated. The slice which showed largest area of hemothorax was selected and the height and width of the hemothorax area were measured. The number of slices which showed radiographic evidence of hemothorax was counted. Regression analysis was done and measured amount of hemothorax, the height and width of the hemothorax area for each slice and number of slices were put as variables. And following equation was derived. V=108.3A-0.8B-7.4C+84.7 [R2=0.74 [ V: amount of hemothorax, A: height, B: width, C: number of slices Total amount of blood from thoracic drainage was compared to the measured amount by computed tomography and the relation between the two values was statistically significant.[p=0.001 In conclusion, quantitative estimation of size of hemothorax was possible by the above equation and the process was very helpful for determination policy of treatment of individual patient.

  • PDF