• Title/Summary/Keyword: Thorax, CT

Search Result 57, Processing Time 0.034 seconds

Development of Conformal Radiotherapy with Respiratory Gate Device (호흡주기에 따른 방사선입체조형치료법의 개발)

  • Chu Sung Sil;Cho Kwang Hwan;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.41-52
    • /
    • 2002
  • Purpose : 3D conformal radiotherapy, the optimum dose delivered to the tumor and provided the risk of normal tissue unless marginal miss, was restricted by organ motion. For tumors in the thorax and abdomen, the planning target volume (PTV) is decided including the margin for movement of tumor volumes during treatment due to patients breathing. We designed the respiratory gating radiotherapy device (RGRD) for using during CT simulation, dose planning and beam delivery at identical breathing period conditions. Using RGRD, reducing the treatment margin for organ (thorax or abdomen) motion due to breathing and improve dose distribution for 3D conformal radiotherapy. Materials and Methods : The internal organ motion data for lung cancer patients were obtained by examining the diaphragm in the supine position to find the position dependency. We made a respiratory gating radiotherapy device (RGRD) that is composed of a strip band, drug sensor, micro switch, and a connected on-off switch in a LINAC control box. During same breathing period by RGRD, spiral CT scan, virtual simulation, and 3D dose planing for lung cancer patients were peformed, without an extended PTV margin for free breathing, and then the dose was delivered at the same positions. We calculated effective volumes and normal tissue complication probabilities (NTCP) using dose volume histograms for normal lung, and analyzed changes in doses associated with selected NTCP levels and tumor control probabilities (TCP) at these new dose levels. The effects of 3D conformal radiotherapy by RGRD were evaluated with DVH (Dose Volume Histogram), TCP, NTCP and dose statistics. Results : The average movement of a diaphragm was 1.5 cm in the supine position when patients breathed freely. Depending on the location of the tumor, the magnitude of the PTV margin needs to be extended from 1 cm to 3 cm, which can greatly increase normal tissue irradiation, and hence, results in increase of the normal tissue complications probabiliy. Simple and precise RGRD is very easy to setup on patients and is sensitive to length variation (+2 mm), it also delivers on-off information to patients and the LINAC machine. We evaluated the treatment plans of patients who had received conformal partial organ lung irradiation for the treatment of thorax malignancies. Using RGRD, the PTV margin by free breathing can be reduced about 2 cm for moving organs by breathing. TCP values are almost the same values $(4\~5\%\;increased)$ for lung cancer regardless of increasing the PTV margin to 2.0 cm but NTCP values are rapidly increased $(50\~70\%\;increased)$ for upon extending PTV margins by 2.0 cm. Conclusion : Internal organ motion due to breathing can be reduced effectively using our simple RGRD. This method can be used in clinical treatments to reduce organ motion induced margin, thereby reducing normal tissue irradiation. Using treatment planning software, the dose to normal tissues was analyzed by comparing dose statistics with and without RGRD. Potential benefits of radiotherapy derived from reduction or elimination of planning target volume (PTV) margins associated with patient breathing through the evaluation of the lung cancer patients treated with 3D conformal radiotherapy.

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.

Evaluation of Total Lung Volume and Density using Multi-Detector Computed Tomography in Normal Dogs (정상견에서 다중채널 컴퓨터단층촬영술을 통한 폐용적과 밀도의 평가)

  • Choi, Ho-Jung;Lee, Ki-Ja;Choi, Soo-Young;Lee, Jung-Woo;Han, Woo-Sok;Lee, In;Kwon, Young-Hang;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.28 no.5
    • /
    • pp.510-515
    • /
    • 2011
  • This study was performed to quantitatively assess the normal lung volume and density according to the position by multi-detector computed tomography (MDCT) in dogs. Helical CT of the thorax was performed on 4 different positions with dorsal, left lateral, right lateral and ventral recumbency in 6 Pekingese and 6 Maltese dogs. During CT scanning, dogs were kept hyperventilated. Through the 3-dimensional reconstruction of CT images, the lung parameters were measured as the volume and density of the left, right including accessory lobe, and total lung. 3D images represented the different lung shape between Pekingese and Maltese dogs. Their difference of total lung volume and total lung density was not significant on the each position in both breeds. Right lung volume was significantly higher than left. The difference of left and right volume was $66.91{\pm}25.1$ ml. Linear relationship was shown between body weight and lung volume of ventral recumbency position. The dependent lung had higher density and lower volume than nondependent lung in both breed dogs. The volume of nondependent lung was not changed compared with the volume on ventral or dorsal recumbency. The total lung volume measured with MDCT is correlated with the lung density, and the lung density is useful to predict the normal total lung volume.

Evaluation of Average CT to Reduce the Artifact in PET/CT (PET/CT 검사에서 호흡에 따른 인공산물을 줄이기 위한 Average CT의 유용성)

  • Kim, Jung-Sun;Nam, Ki-Pyo;Park, Seung-Yong;Ryu, Jae-Kwang;Cha, Min-Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.3-7
    • /
    • 2010
  • Purpose: The usefulness of Positron Emission Tomography (PET) images in diagnosis, staging, recurrent and treatment response evaluation has already been known. However, tumors which are small size, located in lower lobe of lung or upper lobe of liver are shown misalignment, distortion and different Standard Uptake Value (SUV) by respiration in PET images. Therefore, if radiotherapy based on normal respiration, it may cause low treatment response or more side effects because targets which had to treat, out of treat range or over dose to normal tissue. The purpose of this study is to evaluate attenuation-correction with Average CT (ACT) for more accuracy SUV measurement and minimize artifact by respiration. Materials and Methods: 13 patients, who had tumors which are around the diaphragm, underwent ACT scan after Helical CT (HCT) scan with PET/CT (Discovery DSTE 8; GE Healthcare). We quantified the differences between attenuation corrected image with HCT and attenuation corrected image with ACT in artifact size and maximum SUV ($SUV_{max}$). Artifacts were evaluated by measurement of the curved photogenic area in the lower thorax of the PET images for all patients. $SUV_{max}$ was measured separately at the primary tumors. Analysis program was Advantage Workstation v4.3 (GE Healthcare). Patients were injected with 7.4 MBq (0.2 $mC_i$) per kg of $^{18}F$-FDG and scanned 1 hour after injection. The PET acquisition was 3 minute per bed. Results: Significantly lower artifact were observed in PET/ACT images than in PET/HCT images (below-thoracic artifacts caused by under corrected $1.5{\pm}3.5$ cm vs. $13.4{\pm}4.2$ cm). Significantly higher $SUV_{max}$ were noted in PET/ACT images than in PET/HCT images in the primary tumor. Compared with PET/HCT images, $SUV_{max}$ in PET/ACT images were higher by $5.3{\pm}3.9%$ (mean value) tumor. The highest difference was observed in Lower lobe of lung (7.7 to 8.7; 13%). Conclusion: Due to its significantly reduced artifacts in lower thoracic, attenuation corrected image with ACT images provided more reliable $SUV_{max}$ and may be helpful in monitoring treatment response. Moreover, ACT can separate upper lobe of liver and lower lobe of lung, it may be helpful in interpretation. ACT will be clinically useful, considering increased dose caused by ACT scan and adapt.

  • PDF

Mediastinal pancreatic pseudocyst naturally drained by esophageal fistula (식도 누공으로 자연 배액된 종격동 췌장성 가성낭종)

  • Park, Soo Ho;Park, Seung Keun;Kim, Sang Hyun;Choi, Won Kyu;Shim, Beom Jin;Park, Hee Ug;Jung, Chan Woo;Choi, Jae Won
    • Journal of Yeungnam Medical Science
    • /
    • v.34 no.2
    • /
    • pp.254-259
    • /
    • 2017
  • Mediastinal pancreatic pseudocyst is a rare complication of acute or chronic pancreatitis. Pleural effusion and pneumonia are two of the most common thoracic complications from pancreatic disease, while pancreaticopleural fistula with massive pleural effusion and extension of pseudocyst into the mediastinum is a rare complication of the thorax from pancreatic disease. To the best of our knowledge, there have been no case reports of mediastinal pancreatic pseudocyst-induced esophageal fistula in Korea to date. Here in, we report a case about 43-year-old man of mediastinal pancreatic pseudocyst-induced esophageal fistula presenting with chest pain radiating toward the back and progressive dysphagia. The diagnosis was confirmed by an esophagogastroduodenoscopy and abdomen computed tomography (CT). The patient was treated immediately using a conservative method; subsequently, within 3 days from treatment initiation, symptoms-chest pain and dysphagia- disappeared. In a follow-up gastroscopy 7 days later and abdomen CT 12 days later, mediastinal pancreatic pseudocyst showed signs of improvement, and esophageal fistula disappeared without any complications.

Korean Clinical Imaging Guidelines for Justification of Diagnostic Imaging Study for COVID-19 (한국형 COVID-19 흉부영상 진단 시행 가이드라인)

  • Kwang Nam Jin;Kyung-Hyun Do;Bo Da Nam;Sung Ho Hwang;Miyoung Choi;Hwan Seok Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.265-283
    • /
    • 2022
  • To develop Korean coronavirus disease (COVID-19) chest imaging justification guidelines, eight key questions were selected and the following recommendations were made with the evidence-based clinical imaging guideline adaptation methodology. It is appropriate not to use chest imaging tests (chest radiograph or CT) for the diagnosis of COVID-19 in asymptomatic patients. If reverse transcription-polymerase chain reaction testing is not available or if results are delayed or are initially negative in the presence of symptoms suggestive of COVID-19, chest imaging tests may be considered. In addition to clinical evaluations and laboratory tests, chest imaging may be contemplated to determine hospital admission for asymptomatic or mildly symptomatic un-hospitalized patients with confirmed COVID-19. In hospitalized patients with confirmed COVID-19, chest imaging may be advised to determine or modify treatment alternatives. CT angiography may be considered if hemoptysis or pulmonary embolism is clinically suspected in a patient with confirmed COVID-19. For COVID-19 patients with improved symptoms, chest imaging is not recommended to make decisions regarding hospital discharge. For patients with functional impairment after recovery from COVID-19, chest imaging may be considered to distinguish a potentially treatable disease.

Using Ultrasonography in Korean Medicine to Observe Organs and Diseases, and Evidence of its Use (한의학에서 초음파 진단기기를 활용한 장부 및 질병 관찰과 그 활용 근거)

  • Baik, Tai-Hyeun
    • The Journal of Korean Medicine
    • /
    • v.35 no.3
    • /
    • pp.70-92
    • /
    • 2014
  • Objectives: Due to advance of science and IT technology, high tech imaging equipment like ultrasonography, CT, MRI and PET scan is constantly being developed and progressed; use of these techniques is needed for Korean medicine. Methods: Historical study was undertaken on the evidence of using ultrasonography. Normal organs and various sorts of diseases were also observed by ultrasonography. Results: Korean medicine judges disease of internal organs and condition of health by symptoms of functional disease and organic disease based on anatomical theory. Ultrasonography based on anatomical theory is non-invasive and free from radiation exposure and can be performed directly from clinical practice in real-time. Ultrasonography can be a big help for securing the stability of the internal organs in inserting needles in the thorax and abdomen as well as diagnosing functional and organic diseases based on anatomical theory. Conclusion: We look forward to a great development of scientification and objectification of Korean medicine by using and researching imaging equipment based on anatomical theory as well as ultrasonography.

Surgical Resection of Solitary Fibrous Tumor in the Parietal Pleura -Report of One Case- (흉막에 발생한 고립성 섬유종의 외과적 치험)

  • 이종호;심성보
    • Journal of Chest Surgery
    • /
    • v.29 no.7
    • /
    • pp.798-801
    • /
    • 1996
  • Solitary fibrous tumors of the pleura are rare, slow-growing benign neoplasm, originating from submesothelial Hbroblasts. Approximately 80% of solitary fibrous tumors of the pleura originate in . the visceral pleura and 20% in the parietal pleura. Many of these tumors are pedunculated, attached to the visceral pleura via a well-vasculariEed stalk, and in size from 1 to 36cm with a mean of 6cm. This case report is of a 48 year old woman who presented with dyspnea and right flank pain. Preoperative chest x-ray showed increased hazy density at right lower lung field, and CT scan showed huge heterogeneous mass which was located in right mid and lower thorax. She underwent surgical resec- tion and a lOX15X loom(2200gm weigh) sized large mass was excised. Final histologic diagnosis was solitary fibrous tumor of the plara. The patient was discharged without any complications postoperately.

  • PDF

Chest Wall Hamartoma in Infancy A case report (흉벽의 간엽세포종(과오종)수술치험 1예 보고)

  • Jo, Hyeon-Min;Kim, Hae-Gyun;Mun, Dong-Seok
    • Journal of Chest Surgery
    • /
    • v.29 no.10
    • /
    • pp.1170-1172
    • /
    • 1996
  • Chest wall hamartoma Is a very rare disease. The female infant was suffered from frequent upper respiratory infection. The chest AP revealed destruction of the ribs and widening of the intercostal space Chest CT demonstrated well-defined solid and cystic extrapleural mass. Chest M Rl revealed high signal and low signal intensities In the mass. In December, 1995, she underwent excision of the mass with partial resection of the ribs and ch st wall reconstruction with thick Cortex patch. The chest wall hamartoma was confirmed with histopathological examination. The postop course was smooth and uneventful.

  • PDF

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF