• Title/Summary/Keyword: Thiocyanate ion-selective electrode

Search Result 6, Processing Time 0.019 seconds

The PVC Membrane Electrode for Measuring Hazardous Anion in Waste Water Process (폐수처리 공정중 유해음이온을 측정하기 위한 PVC 막 전극)

  • Woo, In-Sung;An, Hyung-Hwan
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.4
    • /
    • pp.47-59
    • /
    • 1995
  • The perchlorate, thiocyanate, and nitrate ion-selective PVC membrance electrode for measuring hazardous anion in waste water were developed by incorporating the quaternary ammonium salts as active material. Ion-selective characteristics in waste water were studied by the useful pH range, the selective coefficients to various interfering anions, and the stability of electrode potential. DBP was best as a plasticizer. The effect of the membrane thickness on the electrode characteristics was improved with decreasing the membrane thickness, but below the optimum membrane thickness the electrode exhibited an inverse trend. The electrode potential of perchlorate, thiocyanate, and nitrate electrode with TDDA, as active material, was stable within the pH range 4-11, 3-12, and 4-10 repectively. And the long-term potential stability of these electrodes were 3.0, 3.5, and 3.5 months respectively. The order of the selectivity coefficients was as shown below ; $ClO_4{^-}$ > $SCN^-$ > $I^-$ > $NO_3{^-}$ > $Br^-$ > $CN^-$ > $F^-$ > $Cl^-$ > $Ac^-$ > $H_2PO_4{^-}$, $SO_4{^-}$.

  • PDF

Organopalladium(II) Complexes as Ionophores for Thiocyanate Ion-Selective Electrodes

  • Kim, Dong-Wan;Lee, So-Hyun;Kim, Jung-Hwan;Kim, Jin-Eun;Park, Jong-Keun;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.10
    • /
    • pp.2303-2308
    • /
    • 2009
  • A thiocyanate poly(vinyl chloride) (PVC) membrane electrode based on [1,2-bis(diphenylphosphino)ethane]dihalopalladium( II), [(dppe)$PdX_2$, X = Cl ($L^1$), X = I ($L^2$)] as active sensor has been developed. The diiodopalladium complex, [(dppe)$PdI_2](L^2$) displays an anti-Hofmeister selectivity sequence: $SCN^-\;>\;I^-\;>\;{ClO_4}^-\;>\;Sal^-\;>\;Br^-\;>\;{NO_2}^-\;>\;{HPO_4}^-\;>\;AcO^-\;>\;{NO_3}^-\;>\;{H_2PO_4}^-\;>\;{CO_3}^{2-}$. The electrode exhibits a Nernstian response (-59.8 mV/decade) over a wide linear concentration range of thiocyanate ($(1.0\;{\times}\;10^{-1}\;to\;5.0\;{\times}\;10^{-6}$ M), low detection limit ($(1.1\;{\times}\;10^{-6}$ M), fast response $(t_{90%}$ = 24 s), and applicability over a wide pH range (3.5∼11). Addition of anionic sites, potassium tetrakis[p-chlorophenyl] borate (KTpClPB) is shown to improve potentiometric anion selectivity, suggesting that the palladium complex may operate as a partially charged carrier-type ionophore within the polymer membrane phase. The reaction mechanism is discussed with respect to UV-Vis and IR spectroscopy. Application of the electrode to the potentiometric titration of thiocyanate ion with silver nitrate is reported.

Improved Thiocyanate-Selective Electrode Based on Tetra(trimethylphenyl)-porphyrinato Manganese(III) Chloride: The Electronic and pH Effects

  • Seo, Hyung-Ran;Lee, Hyo-Kyoung;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.10
    • /
    • pp.1484-1488
    • /
    • 2004
  • The thiocyanate-selective PVC membrane electrodes based on 5,10,15,20-tetrakis(2,4,6-trimethylphenyl)-porphyrinatomanganese(III) chloride [Mn(TMP)Cl] and 5,10,15,20-tetrakis(2,6-dichlorophenyl)porphyrinatomanganese(III) chloride $[Mn(Cl_8TPP)Cl]$ as ion carriers were investigated. The effect of ionophores, membrane compositions, plasticizers, and solution pHs on the response characteristics were studied. The Mn(TMP)Cl as an ionophore shows the best potentiometric sensitivity with a slope of -58.7 mV/decade and a detection limit of $log[SCN^-]$ = -6.90, and selectivity for thiocyanate over strong hydrophobic interfering anions such as ${ClO_4}^-$ and salicylate. The potentiometric response is affected by the electronic effect of the substituents and solution pHs. The presence of substituents with electron donating and more liphophilic characters around the ligated metal center produces an improved response toward $SCN^-$.

The Polymer Membrane Electrode by Surfactants for Measuring Continuously Thiocyanate Ion in Wastewater (폐수중 티오시안산이온을 측정하기 위한 계면활성제를 이용한 고분자 막전극)

  • 최종석;안형환;강안수;우인성;황명환
    • Journal of the Korean Society of Safety
    • /
    • v.6 no.4
    • /
    • pp.13-20
    • /
    • 1991
  • Ion-selective electrode responsive to the thiocynate ion prepared by using the quaternary ammonium salts as a active material and PVC as a membrane matrix. The effect of chemical structure and composition of active material, and the membrane thickness on the linear response. the detection limit, and Nernstian slope of the electrode studied. Under the above optimum conditions of membrane, the effect of pH and the selectivity coefficients to various interfering anions were compared and investigated. It was concluded that the functions of thiocynate ion-selective electrode(ISE) were closely related to the chemical structure of the quaternary ammonium salts. The linear response, and the detection limit of the electrode potential increased with the increase of the carbon chain length of the alkyl group in the quaternary ammonium salts in the ascending order of Aliquat 336T, TOAT, TDAT, and TDDAT. The optimum membrane thickness was 0.3mm. The electrode characteristics was better with the decrease of the concentration of active material, and the best concentration was 3 weight percent. The membrane potential was independent of the pH variation in the region from pH 2 to 12. The order of the selectivity coefficients is as follows:Cl $O_4$$^{[-10]}$$I^{[-10]}$ >N $O_3$$^{[-10]}$ >B $r^{[-10]}$$F^{[-10]}$ >C $l^{[-10]}$ >O $A_{c}$ $^{[-10]}$ 〓S $O_4$$^{2-}$.

  • PDF

The Novel SCN- Ion-selective Electrode Based on the 1-Benzyl-3-(4-nitrophenyl) thio-urea Ionophore

  • Lee, Kyungmi;Kang, Dong Hyeon;Choe, Ju Eun;Yun, Mira;You, Jung-Min;Go, Min Jeong;Lee, Junseong;Jeon, Seungwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.11
    • /
    • pp.3175-3180
    • /
    • 2014
  • A potentiometric sensor based on the 1-benzyl-3-(4-nitrophenyl) thio-urea was synthesized and tested as an ionophore in PVC based membrane sensor towards $SCN^-$ ions. This membrane exhibits a linear stable response over a wide concentration range ($1.0{\times}10^{-5}$ to $1.0{\times}10^{-2}M$) with a slope of -59.2 mV/dec., a detection limit of ${\log}[SCN^-]=-5.05$, and a selectivity coefficient for thiocyanate against perchlorate anion of ${\log}K^{pot}_{SCN^-j}=-0.133$. The selectivity series of the membrane is as follows: $SCN^-$ > $ClO_4{^-}$ > $I^-$ > $NO_3{^-}$ > $HSO_3{^-}$ > $Cl^-$ > $HSO_4{^-}$ > $F^-$ > $CH_3COO^-$ > $HCO_3{^-}$ > $Br^-$ > $H_2PO_4{^-}$ > $SO{_3}^{2-}$ > $SO{_4}^{2-}$ > $CO{_3}^{2-}$. The proposed electrode showed good selectivity and a good response for the $SCN^-$ ion over a wide variety of other anions in pH 6.0 buffer solutions and has a fast response time of about < 5s. The influences of the membrane by pH, ionophore, and plasticizer were studied.

A Solid-Contact Indium(III) Sensor based on a Thiosulfinate Ionophore Derived from Omeprazole

  • Abbas, Mohammad Nooredeen;Amer, Hend Samy
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.4
    • /
    • pp.1153-1159
    • /
    • 2013
  • A novel solid-contact indium(III)-selective sensor based on bis-(1H-benzimidazole-5-methoxy-2-[(4-methoxy-3, 5-dimethyl-1-pyridinyl) 2-methyl]) thiosulfinate, known as an omeprazole dimer (OD) and a neutral ionophore, was constructed, and its performance characteristics were evaluated. The sensor was prepared by applying a membrane cocktail containing the ionophore to a graphite rod pre-coated with polyethylene dioxythiophene (PEDOT) conducting polymer as the ion-to-electron transducer. The membrane contained 3.6% OD, 2.3% oleic acid (OA) and 62% dioctyl phthalate (DOP) as the solvent mediator in PVC and produced a good potentiometric response to indium(III) ions with a Nernstian slope of 19.09 mV/decade. The constructed sensor possessed a linear concentration range from $3{\times}10^{-7}$ to $1{\times}10^{-2}$ M and a lower detection limit (LDL) of $1{\times}10^{-7}$ M indium(III) over a pH range of 4.0-7.0. It also displayed a fast response time and good selectivity for indium(III) over several other ions. The sensor can be used for longer than three months without any considerable divergence in potential. The sensor was utilized for direct and flow injection potentiometric (FIP) determination of indium(III) in alloys. The parameters that control the flow injection method were optimized. Indium(III) was quantitatively recovered, and the results agreed with those obtained using atomic absorption spectrophotometry, as confirmed by the f and t values. The sensor was also utilized as an indicator electrode for the potentiometric titration of fluoride in the presence of chloride, bromide, iodide and thiocyanate ions using indium(III) nitrate as the titrant.