• Title/Summary/Keyword: Thin flap

Search Result 134, Processing Time 0.022 seconds

Vibration Control of Pretwisted Composite Thin-walled Rotating Beam with Non-uniform Cross Section (초기 비틀림각을 갖는 비균일 박판보 블레이드의 진동제어)

  • 임성남;나성수
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.6
    • /
    • pp.486-494
    • /
    • 2004
  • This paper addresses the dynamic modeling and closed-loop eigenvibration analysis of composite rotating pretwisted fan blade modeled as non-uniform thin-walled beam with bi-convex cross-section fixed at the certain presetting angle and incorporating piezoelectric induced damping capabilities. The blade model incorporates non-classical features such as transverse shear, rotary inertia and includes the centrifugal and Coriolis force field. A velocity feedback control law relating the piezoelectiriccally induced transversal bending moment at the beam tip with the appropriately selected kinematical response quantity is used and the beneficial effects upon the closed loop eigenvibration of the blade are highlighted.

DEVELOPMENT OF A REFINED STRUCTURAL MODEL FOR COMPOSITE BLADES WITH ARBITRARY SECTION SHAPES (임의의 단면 형상을 갖는 복합재료 블레이드의 첨단 구조해석 모델 개발)

  • Jung, Sung-Nam;Inderjit Chopra
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.11a
    • /
    • pp.215-218
    • /
    • 1999
  • A general structural model, which is an extension of the Vlassov theory, is developed for the analysis of composite rotor blades with elastic couplings. A comprehensive analysis applicable to both thick-and thin-walled composite beams, which can have either open- or closed profile is formulated. The theory accounts for the effects of elastic couplings, shell wall thickness, and transverse shear deformations. A semi-complementary energy functional is used to account for the shear stress distribution in the shell wall. The bending and torsion related warpings and the shear correction factors are obtained in closed form as part of the analysis. The resulting first order shear deformation theory describes the beam kinematics in terms of the axial, flap and lag bending, flap and lag shear, torsion and torsion-warping deformations. The theory is validated against experimental results for various cross-section beams with elastic couplings.

  • PDF

Serially expanded flap use to treat large hairless scalp lesions

  • Shin, Dongwoo;Kim, Yong Hun;Song, Han Gyeol;Hong, Jong Won
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.6
    • /
    • pp.408-411
    • /
    • 2019
  • Hairless scalp areas can occur due to trauma, tumors, or congenital disease. This aesthetically unpleasing condition can lead to psychosocial distress, and thin skin flaps may be prone to scarring. Treating the hairless scalp by simple excision is challenging because of skin tension. Tissue expanders are a good option for hairless scalp resurfacing. However, a single expansion may be inadequate to cover the entire defect. This report describes good results obtained using a serial resurfacing method involving re-expansion of the flap with a tissue expander to treat two patients with large lesions: one due to aplasia cutis congenital and another who underwent dermatofibrosarcoma protuberance resection. The results suggest that scalp resurfacing by serial tissue expansion using a tissue expander can be used for extensive lesions.

Design of Airfoil with Tab-assisted Flap System for Increasement of Controllability and Stability (조종성과 안정성 증가를 위한 플랩-­탭 익형의 설계)

  • No, Hyeon-Seop;Kim, Seong-Hwan;Park, Hyeon-U;Lee, A-Reum;Son, Chan-Gyu;Lee, Gwan-Jung;O, Se-Jong
    • Proceeding of EDISON Challenge
    • /
    • 2012.04a
    • /
    • pp.13-16
    • /
    • 2012
  • 본 논문에서는 항공기의 제어 안정성(Control Stability)과 조종성(Controllability), 그리고 기계 하중을 줄여 구조와 공기역학적인 안정성을 향상시키기 위해 고양력장치(High-lift Device)인 플랩에 탭이 추가된 익형을 설계하였다. 이 과정에서 한정된 해석자원 때문에 많은 설계조건을 해석하는데 어려움이 있었다. 이를 해결 하기위해 얇은 익형 해석(Thin Airfoil Theory)을 이용하여 지정된 설계구속조건을 통해 시위선을 지정하고 이를 바탕으로 두께를 부여하여 최종적인 익형을 설계하였다. EDISON CFD 2.0 Solver를 이용해 최종 설계한 익형의 성능을 해석하였다. 이를 바탕으로 플랩만 존재하는 익형에 비해 양력손실률이 15%이하로 감소하고, 힌지 모멘트가 최소인 공기역학적 익형을 산출하였다.

  • PDF

Reconstruction of the Extremities with the Dorsalis Pedis Free Flap (족 배 유리 피부판을 이용한 사지 재건술)

  • Lee, Jun-Mo;Kim, Moon-Kyu
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.1
    • /
    • pp.77-83
    • /
    • 1999
  • The skin on the dorsum of the foot is a source of the reliable thin and sensory cutaneous free tissue transplantation with or without tendon, bone and joint. A composite flap with attached vascularized tendon grafts for the combined loss of skin and tendon on the dorsum of the hand and foot offers an immediate one stage solution to this problem. The flap provides a very durable innervated tissue cover for the heel of the foot and the dorsum of the hand and an osteocutaneous transfer combined with the second metatarsal. The major dorsalis pedis artery is constant in size, but the first dorsal metatarsal artery is variable in size and location. The dorsal surface of the foot receives sensory innervation through the superficial peroneal nerve and the first web through the deep peroneal nerve. Authors had performed 5 dorsalis pedis free flap transplantation in the foot and hand at Department of Orthopedic Surgery, Chonbuk National University Hospital from August 1993 through August 1997 and followed up for the period of between 19 and 67 months until March 1999. The results were as follows 1. 5 cases dorsalis pedis free flap transfer to the foot(4 cases) and the hand(1 case) were performed and the recipient was foot dorsum and heel 2 cases each and hand dorsum 1 case. 2 All of 5 cases(100%) were survived from free flap transfer and recipient artery was dorsalis pedis artery(2 cases), anterior tibial artery(1 case), posterior tibial artery(1 case) and ulnar artery(1 case) and recipient veins were 2 in number except in the hand. 3. Long term follow up of the exterior and maceration was good and sensory recovery was poor 4. Donor site was covered with full thickness skin graft obtained from one or both inguinal areas at postoperative 3rd week and skin graft was taken good and no morbidity was showed.

  • PDF

Functional Results of Soft Palate Defect Reconstruction using Radial Forearm Free Flap after Tonsil Cancer Surgery (편도암 절제술후 전완유리피판술을 이용한 연구개 결손부 재건의 기능적 결과)

  • Kim, Min-Sik;Sun, Dong-Il;Park, Hae-Sup;Cho, Seung-Ho;Jai, Hyeon-Soon
    • Korean Journal of Bronchoesophagology
    • /
    • v.5 no.2
    • /
    • pp.191-197
    • /
    • 1999
  • Background and Objective : Soft palate plays a great role in function of speech and swallowing. Ablation of tonsil cancer results in multi-demensional defect including soft palate in most cases and restoration of the postoperative oral cavity function is a continuing surgical challenge. Although a variety of techniques are available, radial forearm free flap has been known as an effective method for these defect, which offers a thin, pliable, and relatively hairless skin, and a long vascular pedicle. The aim of the present study is to report the speech and swallowing function test results of our 5 consecutive radial forearm free flaps used for tonsil cancers. Materials and Methods : We reviewed the medical records of 5 patients who were offered intraoral reconstruction with a radial forearm free flap after ablative surgery for tonsil cancers, from Dec. 1997 to Oct. 1998, and analyzed the surgical methods, complications, and speech and swallowing function test results. We have examined with modified barium swallow to evaluate postoperative wallowing function and articulation and resonance test for speech. Results : The tumor sizes by TNM stage(AJCC, 1997) were T1(1), T2(2), and T4(3). The paddles of flaps were tailored in multilobed designs from oval shape to pentalobed design and in variable size from 24$cm^2$ to 108$cm^2$(average size = 78.4$cm^2$), according to the defect after ablation. This procedures resulted in satisfactory flap success and functional results all but 1 case of flap contracture in 2 postoperative week, achieved early oral diet until 16-57 postoperative day(average, 28 days) and social speech. The oropharyngeal defect including soft palate reconstruction with radial forearm free flap might be an excellent method for the maximal functional results, after ablative surgery of tonsil cancer that results in multidimensional defect.

  • PDF

Defatting Vestibuloplasty for Functional and Esthetic Reconstruction of Tongue

  • Park, Si-Yeok;Kim, Min-Keun;Kim, Seong-Gon;Kwon, Kwang-Jun;Byun, Jin-Soo;Park, Chan-Jin;Park, Young-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.6
    • /
    • pp.298-302
    • /
    • 2014
  • The radial forearm free flap (RFFF) is a thin and pliable tissue with many advantages for tongue reconstruction. However, tongues reconstructed with RFFF occasionally need revision surgery because inadequate defect measurement at primary surgery can lead to bulkiness and limited movement of reconstructed tongue. In this case, the patient underwent partial glossectomy and RFFF reconstruction for treatment of tongue cancer five years prior. We could not make a lower denture for the patient, because the alveolo-lingual sulcus of tongue was almost lost. So we performed vestibuloplasty with a modified Kazanjian method on the lingual vestibule of the mandibular right posterior area, and defatting surgery to debulk the flap. After surgery, we observed that the color and texture of the revised tongue changed to become similar with adjacent tissue. The patient obtained a more functional and esthetic outcome. Accordingly, we present a case report with a review of relevant literature.

Microvascular Reconstruction of Extensive Foot Injuries (유리피판술을 이용한 족부재건)

  • Chung, Yoon-Kyu;Chung, Seum;Kim, Joo-Bong
    • Archives of Reconstructive Microsurgery
    • /
    • v.3 no.1
    • /
    • pp.64-71
    • /
    • 1994
  • The successful treatment of the extensively traumatized foot warrants reconstruction utilizing tissue that will provide adequate coverage, is resistant to infection, thin enough to conform to the contours of the foot as well as durable to constant frictional movement and weight bearing. Currently, free flaps offer the best means in achieving these difficult and sometimes contradictory goals. We treated twenty-one patients suffering from extensive soft tissue loss of the foot due to trauma, electric burn or postburn sequelae with free flaps. A fasciocutaneous, musculocutaneous or muscle flap with skin grafting was used based on the location, volume of tissue required, and the functional anatomical requirement of the injured region. The follow-up duration averaged twenty-nine months. From our group of patients, we believe that the muscle free flap with skin grafting offers the most favorable outcome.

  • PDF

Development of High Sensitive Integrated Dual Sensor to Detect Harmful Exhaust Gas and Odor for the Automotive (악취분별능력을 가진 자동차용 고기능 듀얼타입 집적형 유해가스 유입차단센서 개발)

  • Chung, Wan-Young;Shim, Chang-Hyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.7
    • /
    • pp.616-623
    • /
    • 2007
  • A dual micro gas sensor array was fabricated using nano sized $SnO_2$ thin films which had good sensitivities to CO and combustible gases, or $H_2S$ gas for air quality sensors in automobile. The already existed air quality sensor detects oxidizing gases and reducing gases, the air quality sensor(AQS), located near the fresh air inlet detected the harmful gases, the fresh air inlet door/ventilation flap was closed to reduce the amount of pollution entering the vehicle cabin through HVAC(heating, ventilating, and air conditioning) system. In this study, to make $SnO_2$ thin film AQS sensor, thin tin metal layer between 1000 and $2000{\AA}$ thick was oxidized between 600 and $800^{\circ}C$ by thermal oxidation. The gas sensing layers such as $SnO_2$, $SnO_2$(pt) and $SnO_2$(+CuO) were patterned by metal shadow mask for simple fabrication process on the silicon substrate. The micro gas sensors with $SnO_2$(+Pt) and $SnO_2$(CuO) showed good selectivity to CO gas among reducing gases and good sensitivity to $H_2S$ that is main component of bad odor, separately.

Biodegradable Meniscus Screw Fixation of Thin Flap Osteochondral Fracture - Two Case Report - (흡수성 반월상 연골나사를 사용한 얇은 골연골 골절의 치료 - 증례 보고 -)

  • Chon, Je-Gyun;Sun, Doo-Hoon;Song, In-Soo;Kim, Young-Woo;Jung, Jae-Yong;Lee, Bong-Ju
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.2
    • /
    • pp.131-134
    • /
    • 2010
  • Inappropriate treatment of osteochondral fracture can cause osteoarthritis, pain, functional disorder. With large osteochondral fracture, reduction and fixation of the fragment using metal implant. However, when the bone fragment had less than 2mm, the fragment extracted because of difficulty of fragment fixation. Authors treated patients with fracture fragment thickness less than 2mm of osteochondral dissecans in medial femoral condyle and patella fracture using biodegradable meniscus screw, and then we obtained good result.

  • PDF