• Title/Summary/Keyword: Thicknesses effect

Search Result 405, Processing Time 0.028 seconds

Repeatabilities and Correlations among Average Daily Gain, Backfat Thickness and Lean Percent in Swine (검정종료돈의 체중변화에 따른 일당중체량, 등지방두께 및 정육율의 반복력과 상관)

  • Kim, H.C.;Kim, B.W.;Song, K.L.;Oh, H.S.;Son, C.J.;Ha, D.W.;Lee, J.G.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.523-530
    • /
    • 2002
  • Repeatabilities and Correlations among Average Daily Gain, Backfat Thickness and Lean Percent in Swine The repeatability, correlation and rank correlation coefficients among average daily gain, backfat thickness and lean percent were estimated on the basis of records tested from August 1999 to February 2000 with 695 pigs of Duroc, Landrace and Yorkshire boars and gilts tested at 2nd Korea Swine Test Station located in Ha-dong, Kyeongnam Province. The effect of the sex, breed and month of measured were estimated by the least square method. The repeatabilities were estimated from the component of variance among repeated measurements of the trait for the same animal. The results obtained are summarized as follow ; 1. The means of the major economic traits studied were 142.1 days, 173.7 days and 182.5 days for age at 1st, 2nd and 3rd measure, 57.9%, 56.2% and 55.2% for lean percent at 1st, 2nd and 3rd measure, 1.33cm, 1.61cm and 1.63cm for backfat thickness at 1st, 2nd and 3rd measure, 946.6g, 879.2g and 879.4g for average daily gain at 1st, 2nd and 3rd measure, respectively. 2. The correlation coefficients between the backfat thicknesses measured at 1st and 2nd, at 2nd and 3rd, at 1st and 3rd were 0.424, 0.700 and 1.424, respectively. The correlation coefficients between the lean percent measured at 1st and 2nd, at 2nd and 3rd, at 1st and 3rd were 0.493, 0.619 and 0.471, respectively. The correlation coefficients between the average daily gain measured at 1st and 2nd, at 2nd and 3rd, at 1st and 3rd were 0.716, 0.861 and 0.601, respectively. 3. The rank correlation coefficients between backfat thickness measured at 1st and 2nd, at 2nd and 3rd, at 1st and 3rd were 0.438, 0.693 and 0.441, respectively. The rank correlation coefficients between lean percent measured at 1st and 2nd, at 2nd and 3rd, at 1st and 3rd were 0.508, 0.593 and 0.478, respectively. The rank correlation coefficients between average daily gain measured at 1st and 2nd, at 2nd and 3rd, at 1st and 3rd were 0.704, 0.834 and 0.571, respectively. 4. The estimated repeatabilities of the traits studied were 0.428 for the lean percent, 0.374 for the backfat thickness and 0.673 for the average daily gain, respectively.

Effects of Surface Finishes on the Low Cycle Fatigue Characteristics of Sn-based Pb-free Solder Joints (금속패드가 Sn계 무연솔더의 저주기 피로저항성에 미치는 영향)

  • Lee, Kyu-O;Yoo, Jin
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.3
    • /
    • pp.19-27
    • /
    • 2003
  • Surface finishes of PCB laminates are important in the solder joint reliability of flip chip package because the types and thicknesses of intermetallic compound(IMC), and compositions and hardness of solders are affected by them. In this study, effects of surface finishes of PCB on the low cycle fatigue resistance of Sn-based lead-free solders; Sn-3.5Ag, Sn-3.5Ag-XCu(X=0.75, 1.5), Sn-3.5Ag-XBi(X=2.5, 7.5) and Sn-0.7Cu were investigated for the Cu and Au/Ni surface finish treatments. Displacement controlled room temperature lap shear fatigue tests showed that fatigue resistance of Sn-3.5Ag-XCu(X=0.75, 1.5), Sn-3.5Ag and Sn-0.7Cu alloys were more or less the same each other but much better than that of Bi containing alloys regardless of the surface finish layer used. In general, solder joints on the Au/Ni finish showed better fatigue resistance than those on the Cu finish. Cross-sectional fractography revealed microcracks nucleation inside of the interfacial IMC near the solder mask edge, more frequently on the Cu than the Au/Ni surface finish. Macro cracks followed the solder/IMC interface in the Bi containing alloys, while they propagated in the solder matrix in other alloys. It was ascribed to the Bi segregation at the solder/IMC interface and the solid solution hardening effect of Bi in the $\beta-Sn$ matrix.

  • PDF

Anti-Inflammatory Effects of Poly-${\gamma}$-Glutamic Acid on DNCB-Induced Allergic Contact Dermatitis in Dogs (개에서 DNCB에 의해 유발된 알레르기성 접촉피부염에 대한 폴리감마글루탐산의 항염증 효과)

  • Kim, Hyun-Gon;Kim, Kil-Soo;Oh, Tae-Ho
    • Journal of Veterinary Clinics
    • /
    • v.29 no.4
    • /
    • pp.283-296
    • /
    • 2012
  • Allergic contact dermatitis (ACD) is an inflammatory skin disease and regarded as a prototype of T-cell mediated delayed-type hypersensitivity reactions. Poly-${\gamma}$-glutamic acid (PGA) is a biodegradable polymer that is produced by Bacillus subtilis. This study was performed to assess the effects of PGA in a canine model of ACD. ACD was induced on the back of dogs induced by sensitization and repeated application by 2,4-dinitro-1-chlorobenzene (DNCB). Topical treatment of PGA was applied once a day for 12 days and skin biophysical parameters including transepidermal water loss (TEWL), skin hydration, skin pH, skin thickness and erythema index, were measured every two days during experimental periods. Histopathology and immunohistochemistry were performed to evaluate the antiinflammatory effect. In skin biophysical parameters, TEWL, skin hydration, skin thickness and erythema index were significantly increased, with a maximum increase appeared on day 2 (p < 0.05). On the other hand, skin pH was significantly decreased, with a maximum decrease appeared on day 2 (p < 0.01). After the completion of PGA treatment, skin biophysical parameters were significantly reached those of baseline in a time-dependent manner (p < 0.05). In histopathology, marked increases of epidermal thicknesses were induced after DNCB challenge with numerous inflammatory cell infiltrations and edematous changes, decreases of connective tissue occupied regions in dermis. In addition, marked increases of cytokine - tumor necrosis factor-${\alpha}$ (TNF-${\alpha}$) and interferon-${\gamma}$ (IFN-${\gamma}$)-immunoreactivities in the dermis and of apoptotic markers - caspase-3 and PARP-immunoreactivities in the epidermis were observed in DNCB-PBS control as compared with intact control, respectively (p < 0.01). It means, the ACD and related apoptotic changes were induced by DNCB in the present study. However, these ACD induced by DNCB and related apoptosis in epidermis were significantly inhibited by treatment of PGA treated skin, the decreases of infiltrated inflammatory cells and related decreases of pro-inflammatory cytokine immunoreactivities were also observed (p < 0.01). Based on these findings, PGA may have anti-inflammatory and alleviatory effects in the allergic contact dermatitis.

Evaluating efficiency of application the skin flash for left breast IMRT. (왼쪽 유방암 세기변조방사선 치료시 Skin Flash 적용에 대한 유용성 평가)

  • Lim, Kyoung Dal;Seo, Seok Jin;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.49-63
    • /
    • 2018
  • Purpose : The purpose of this study is investigating the changes of treatment plan and comparing skin dose with or without the skin flash. To investigate optimal applications of the skin flash, the changes of skin dose of each plans by various thicknesses of skin flash were measured and analyzed also. Methods and Material : Anthropomorphic phantom was scanned by CT for this study. The 2 fields hybrid IMRT and the 6 fields static IMRT were generated from the Eclipse (ver. 13.7.16, Varian, USA) RTP system. Additional plans were generated from each IMRT plans by changing skin flash thickness to 0.5 cm, 1.0 cm, 1.5 cm, 2.0 cm and 2.5 cm. MU and maximum doses were measured also. The treatment equipment was 6MV of VitalBeam (Varian Medical System, USA). Measuring device was a metal oxide semiconductor field-effect transistor(MOSFET). Measuring points of skin doses are upper (1), middle (2) and lower (3) positions from center of the left breast of the phantom. Other points of skin doses, artificially moved to medial and lateral sides by 0.5 cm, were also measured. Results : The reference value of 2F-hIMRT was 206.7 cGy at 1, 186.7 cGy at 2, and 222 cGy at 3, and reference values of 6F-sIMRT were measured at 192 cGy at 1, 213 cGy at 2, and 215 cGy at 3. In comparison with these reference values, the first measurement point in 2F-hIMRT was 261.3 cGy with a skin flash 2.0 cm and 2.5 cm, and the highest dose difference was 26.1 %diff. and 5.6 %diff, respectively. The third measurement point was 245.3 cGy and 10.5 %diff at the skin flash 2.5 cm. In the 6F-sIMRT, the highest dose difference was observed at 216.3 cGy and 12.7 %diff. when applying the skin flash 2.0 cm for the first measurement point and the dose difference was the largest at the application point of 2.0 cm, not the skin flash 2.5 cm for each measurement point. In cases of medial 0.5 cm shift points of 2F-hIMRT and 6F-sIMRT without skin flash, the measured value was -75.2 %diff. and -70.1 %diff. at 2F, At -14.8, -12.5, and -21.0 %diff. at the 1st, 2nd and 3rd measurement points, respectively. Generally, both treatment plans showed an increase in total MU, maximum dose and %diff as skin flash thickness increased, except for some results. The difference of skin dose using 0.5 cm thickness of skin flash was lowest lesser than 20 % in every conditions. Conclusion : Minimizing the thickness of skin flash by 0.5 cm is considered most ideal because it makes it possible to keep down MUs and lowering maximum doses. In addition, It was found that MUs, maximum doses and differences of skin doses did not increase infinitely as skin flash thickness increase by. If the error margin caused by PTV or other factors is lesser than 1.0 cm, It is considered that there will be many advantages in with the skin flash technique comparing without it.

  • PDF

Fracture load and marginal fitness of zirconia ceramic coping by design and coloration (유색 및 백색 지르코니아 세라믹 코핑의 코핑 디자인에 따른 파절 하중과 변연 적합성)

  • Shin, Mee-Ran;Kim, Min-Jeong;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.406-415
    • /
    • 2009
  • Purpose: The purpose of this study was to compare the marginal fitness and fracture load of the zirconia copings according to the design with different thickness and coloration. Material and methods: The evaluation was based on 80 zirconia copings. Zirconia copings were fabricated in design with different thicknesses using CAD/CAM system (Everset, KAVO dental GmbH, Biberach, Germany). The designs of copings were divided into four groups. The first group consisted of copings with uniform thickness of 0.3 mm. The thickness in the second group was 0.3 mm on the buccal surface and 0.6 mm on the lingual surface. The third group consisted of coping with uniform thickness of 0.6 mm. The thickness in the fourth group was 0.6 mm on the buccal surface and 1mm on the lingual surface. Each group consisted of 10 colored and 10 uncolored copings. Half of the copings (40) processed with a milling system according to the specific design were sent to be given a color (A3) through saturation in special dye by a manufacturing company. Just after sintering, the marginal discrepancies of copings were measured on the buccal, lingual, mesial and distal surfaces of metal die, under a Video Microscope System (sv-35, Sometech, Seoul, Korea) at a magnification of $\times$ 100. It was remeasured after the adjusting of the inner surface. Next, all copings were luted to the metal dies using reinforced cement {GC FujiCEM (GC Corp. Tokyo, Japan)} and mounted on the testing jig in a Universal Testing Machine (Instron 4467, Norwood, MA, USA). The results were analyzed statistically using the one-way ANOVA test. Results: The obtained results were as follow: 1. The measured value of marginal discrepancy right after sintering was the greatest in the contraction of the buccal area in all groups, except for group I2. 2. There was no significant difference of marginal fitness among the groups in the colored zirconia group (P<.05). 3. When the marginal fitness among the groups in the uncolored zirconia group was considered, group II2 had the smallest marginal discrepancy. 4. When the colored and uncolored groups with the same design were compared, there was a significant difference between I1 and II1 groups. In group 2, 3, and 4, the uncolored zirconia had the greatest marginal fitness (P<.05). 5. After adjustment of inner surface, there was no significant difference in the marginal fitness in all groups when color and design of the zirconia coping were compared. 6. The fracture load of CAD/CAM zirconia copings showed significant difference in group 1, 2, 3, and 4. I4 and II4 had the strongest fracture load. 7. When groups with different color and same design were compared, all colored groups showed greater fracture load (P>.05), with no significance. Conclusion: There was difference in the marginal fitness according to the design and coloration of zirconia copings right after sintering, but it was decided that the copings may well be used clinically if the inner surface are adjusted. The copings should be thick enough for the reinforcement of fracture strength. But considering the esthetics of the visible surfaces (labial and buccal surface), the thickness of copings may be a little thin, without giving any significant effect on the fracture strength. This type of design may be considered when giving priority to preservation of tooth or esthetics.