• 제목/요약/키워드: Thickness of line

검색결과 1,083건 처리시간 0.028초

Effect of Feed Substrate Thickness on the Bandwidth and Radiation Characteristics of an Aperture-Coupled Microstrip Antenna with a High Permittivity Feed Substrate

  • Kim, Jae-Hyun;Kim, Boo-Gyoun
    • Journal of electromagnetic engineering and science
    • /
    • 제18권2호
    • /
    • pp.101-107
    • /
    • 2018
  • The impedance bandwidth and radiation characteristics of an aperture-coupled microstrip line-fed patch antenna (ACMPA) with a high permittivity (${\varepsilon}_r=10$) feed substrate suitable for integration with a monolithic microwave integrated circuit (MMIC) are investigated for various feed substrate thicknesses through an experiment and computer simulation. The impedance bandwidth of an ACMPA with a high permittivity feed substrate increases as the feed substrate thickness decreases. Furthermore, the front-to-back ratio of an ACMPA with a high permittivity feed substrate increases and the cross-polarization level decreases as the feed substrate thickness decreases. As the impedance bandwidth of an ACMPA with a high permittivity feed substrate increases and its radiation characteristics improve as the feed substrate thickness decreases, the ACMPA configuration becomes suitable for integration with an MMIC.

Soft-tissue thickness of South Korean adults with normal facial profiles

  • Cha, Kyung-Suk
    • 대한치과교정학회지
    • /
    • 제43권4호
    • /
    • pp.178-185
    • /
    • 2013
  • Objective: To standardize the facial soft-tissue characteristics of South Korean adults according to gender by measuring the soft-tissue thickness of young men and women with normal facial profiles by using three-dimensional (3D) reconstructed models. Methods: Computed tomographic images of 22 men aged 20 - 27 years and 18 women aged 20 - 26 years with normal facial profiles were obtained. The hard and soft tissues were three-dimensionally reconstructed by using Mimics software. The soft-tissue thickness was measured from the underlying bony surface at bilateral (frontal eminence, supraorbital, suborbital, inferior malar, lateral orbit, zygomatic arch, supraglenoid, gonion, supraM2, occlusal line, and subM2) and midline (supraglabella, glabella, nasion, rhinion, mid-philtrum, supradentale, infradentale, supramentale, mental eminence, and menton) landmarks. Results: The men showed significantly thicker soft tissue at the supraglabella, nasion, rhinion, mid-philtrum, supradentale, and supraglenoid points. In the women, the soft tissue was significantly thicker at the lateral orbit, inferior malar, and gonion points. Conclusions: The soft-tissue thickness in different facial areas varies according to gender. Orthodontists should use a different therapeutic approach for each gender.

동장공정의 로보틱자동화를 위한 설계지원 시스템 (Computer aided design system for robotic painting line)

  • 서석환;조정훈;강대호
    • 한국정밀공학회지
    • /
    • 제11권5호
    • /
    • pp.171-179
    • /
    • 1994
  • For successful implementation of robotic painting system, a structured design and analysis procedure is necessary. In designing robotic system, both functional and economical feasibility should be investigated. As the robotization is complicated task involving implemen- tation details (such as robot selection, accessory design, and spatial layout) together with operation details, the computer aided design and analysis method should be sought. However, conventional robotic design systems and off-line programming systems cannot accommodate these inquiries in a unified fashion. In this research, we develop an interactive design support system for robotization of a cycle painting line. With the developed system called SPRPL (Simulation Package for Robotic Painting Line) users can design the painting objects (via FRAME module), select robot model (ROBOT), design the part hanger (FEEDER), and arrange the workcell. After motion programming (MOTION), the design is evaluated in terms of: a) workpace analysis, b) coating thickness analysis, and c) cycle time (ANALYSIS).

  • PDF

수압에 의한 Expoxy 수지 피복막의 피단강도에 관한 연구 (A Study of Rupture Strength of Epoxy Resin Film by Water Pressure)

  • 백영남
    • 한국표면공학회지
    • /
    • 제9권3호
    • /
    • pp.5-8
    • /
    • 1976
  • In this study, a ruture strength of epoxy resin film coated on the leaking spot in waterpipe line was determined, using water pressure, without interrupting water supply. This results could be used for the sealing of water leakage in large size waterpipe lines. An experimental equation {{{{P=Kt^m~ /R^n~ (m=2, n=3.5) }} was also obtained, where P is the rupture pressure, K is constant, t is the thickness and R is the radius of the resin film. From this results, the safe쇼 thickness of the film for a domestic use was calculated with various radii against the maximum pressure.

  • PDF

Inter-Rater Reliability of Abdominal Muscles Thickness Using Ultrasonography for Different Probe Locations and Thickness Measurement Techniques

  • Lim, One-Bin;Hong, Ji-A;Yi, Chung-Hwi;Cynn, Heon-Seock;Jung, Doh-Heon;Park, Il-Woo
    • 한국전문물리치료학회지
    • /
    • 제18권4호
    • /
    • pp.60-67
    • /
    • 2011
  • Ultrasonography (US) is a recent technique that has proven to be useful for assessing muscle thickness and guiding the rehabilitation decision-making of clinicians and researchers. The purpose of this study was to determine the inter-rater reliability of the US measurement of transversus abdominis (TrA), internal oblique (IO), and external oblique (EO) thicknesses for different probe locations and measurement techniques. Twenty healthy volunteers were recruited in this study. Muscle thicknesses of the transversus TrA, IO, and EO were measured three times in the hook-lying position. The three different probe locations were as follows: 1) Probe location 1 (PL1) was below the rib cage in direct vertical alignment with the anterior superior iliac spine (ASIS). 2) Probe location 2 (PL2) was halfway between the ASIS and the ribcage along the mid-axillary line. 3) Probe location 3 (PL3) was halfway between the iliac crest and the inferior angle of the rib cage, with adjustment to ensure the medial edge of the TrA. The two different techniques of thickness measurement from the captured images were as follows: 1) Muscle thickness was measured in the middle of the muscle belly, which was centered within the captured image (technique A; TA). 2) Muscle thickness was measured along a horizontal reference line located 2 cm apart from the medial edge of the TrA in the captured image (technique B; TB). The intraclass correlation coefficient (ICC [3,k]) was used to calculate the inter-rater reliability of the thickness measurement of TrA, IO and EO using the values from both the first and second examiner. In all three muscles, moderate to excellent reliability was found for all conditions (probe locations and measurement techniques) (ICC=.70~.97). In the PL1-TA condition, inter-rater reliability in the three muscle thicknesses was good to excellent (ICC=.85~.96). The reliability of all measurement conditions was excellent in IO (ICC=.95~.97). Therefore, the findings of this study suggest that TA can be applied to PL1 by clinicians and researchers in order to measure the thickness of abdominal muscles.

고성능 유압 베인펌프의 윤활특성 (Lubrication Characteristics of High Performance Oil Hydraulic Vane Pump)

  • 정재연
    • Tribology and Lubricants
    • /
    • 제9권1호
    • /
    • pp.45-54
    • /
    • 1993
  • The lubrication characteristics of line contacts between the vane and cam ring in an oil hydraulic vane pump with intravanes have been investigated. Variations of the radial acting force of a vane were calculated from previously measured results of dynamic internal pressures in four chambers surrounding a vane, and variations of the film thickness were estimated in both the rotational speed range from 500 to 1500 rpm and in the delivery pressure range from 1 to 14 MPa. The results indicate the variations of the radial acting force and film thickness. It is found that the regimes of lubrication in the vane tip contacts lover rigid-isoviscous to rigidvariable viscosities.

Evaluation of Adhesive Characteristics of Mixed Cross Laminated Timber (CLT) Using Yellow Popular and Softwood Structural Lumbers

  • Keon-Ho KIM;Hyun-Mi LEE;Min LEE
    • Journal of the Korean Wood Science and Technology
    • /
    • 제52권1호
    • /
    • pp.58-69
    • /
    • 2024
  • To evaluate the adhesive characteristics of mixed cross-laminated timber (CLT) using domestic softwoods structural lumber proposed by KS F 3020 and yellow poplar, penetration depth of adhesive and thickness of bonding line were analyzed based on the results of boiling water soaking delamination. 3 Types of adhesives and 2 types of major layer were divided into a 5 ply CLT using yellow popular as minor layer. The bonding performance of the mixed CLT as structural members was evaluated based on the KS F 2081. The thickness of bonding line between layers of the mixed CLT was measured with a scanning electron microscope, and the adhesive penetration depth in the layer members was measured with an optical microscope. As a result of boiling water soaking delamination test of mixed CLT, the CLT specimens using PRF and PUR adhesives met the requirements of KS F 2081. It was verified that the penetration path of the adhesive in the layes was mainly through the tracheid cell in the case of Japanese larch and Korean red pine layers, and through the vessel and radial tissue in yellow popular layers. The penetration depth of the adhesive was the highest for the PRF adhesive under the same pressing time conditions, and the thickness of the bonding line was in inverse proportion to the penetration depth in the case of the PUR adhesive.

X-선 투과검사를 이용한 저항 점용접부 품질평가기법 (Weld Quality Evaluation Method for the Resistance Spot Welds using X-ray Transmission Inspection)

  • 이종대;이소정;방정환;윤길상;김목순;김준기
    • Journal of Welding and Joining
    • /
    • 제32권6호
    • /
    • pp.1-7
    • /
    • 2014
  • For the resistance spot welds of CR1180 and GA1180 TRIP steels, the weld quality evaluation method using the digitalized X-ray transmission imaging apparatus was investigated in comparison with the crosssectional examination method. In the case of the resistance spot welding of CR1180, three circular regions, such as WZ(white zone), GZ(grey zone) and DZ(dark zone), appeared on X-ray image and they corresponded to the diameters of indentation mark, nugget and corona bond, respectively. The variation of X-ray transmission thickness due to the thickness variation of the weld seemed to be mainly responsible for the formation of those contrasts. The X-ray image contrast formed from the variation of transmission thickness at the outer border line of DZ could also enable the inspections of the notch shape, nonuniformity of the welding pressure and spatter from its sharpness, concentricity and the normal straight line, respectively. The X-ray image of the resistance spot weld of galvannealed GA1180 TRIP steel was very similar to that of CR1180 TRIP steel except the crown shaped outer border line of DZ which was considered to be due to the melting behavior of zinc having the boiling temperature even lower than the melting temperature of steel.

Cause Analysis of Flow Accelerated Corrosion and Erosion-Corrosion Cases in Korea Nuclear Power Plants

  • Lee, Y.S.;Lee, S.H.;Hwang, K.M.
    • Corrosion Science and Technology
    • /
    • 제15권4호
    • /
    • pp.182-188
    • /
    • 2016
  • Significant piping wall thinning caused by Flow-Accelerated Corrosion (FAC) and Erosion-Corrosion (EC) continues to occur, even after the Mihama Power Station unit 3 secondary pipe rupture in 2004, in which workers were seriously injured or died. Nuclear power plants in many countries have experienced FAC and EC-related cases in steam cycle piping systems. Korea has also experienced piping wall thinning cases including thinning in the downstream straight pipe of a check valve in a feedwater pump line, the downstream elbow of a control valve in a feedwater flow control line, and failure of the straight pipe downstream of an orifice in an auxiliary steam return line. Cause analyses were performed by reviewing thickness data using Ultrasonic Techniques (UT) and, Scanning Electron Microscope (SEM) images for the failed pipe, and numerical simulation results for FAC and EC cases in Korea Nuclear Power Plants. It was concluded that the main cause of wall thinning for the downstream pipe of a check valve is FAC caused by water vortex flow due to the internal flow shape of a check valve, the main cause of wall thinning for the downstream elbow of a control valve is FAC caused by a thickness difference with the upstream pipe, and the main cause of wall thinning for the downstream pipe of an orifice is FAC and EC caused by liquid droplets and vortex flow. In order to investigate more cases, additional analyses were performed with the review of a lot of thickness data for inspected pipes. The results showed that pipe wall thinning was also affected by the operating condition of upstream equipment. Management of FAC and EC based on these cases will focus on the downstream piping of abnormal or unusual operated equipment.

편측무시 환자에게 실시간 초음파 영상을 이용한 왼쪽 몸통 굽힘 패턴을 적용한 과제지향적 훈련의 효과 -단일 사례 연구- (The Effects of Task-Oriented Training for Left Trunk Flexion Pattern Using Real-Time Ultrasound Imaging -A Single-Subject Experimental Study-)

  • 김지선;기경일;강태우
    • PNF and Movement
    • /
    • 제17권1호
    • /
    • pp.1-9
    • /
    • 2019
  • Purpose: This study investigates the effects of task-oriented training for a left trunk flexion pattern using real-time ultrasound imaging in a stroke patient with unilateral neglect symptoms. Methods: This study used the ABA experimental design, which is a single-subject research method among individual case research methods. For the ABA experimental design, changes in the degree of unilateral neglect, balance ability, and the thickness of the lateral abdominal muscle were visually analyzed during the baseline process, in the intervention period, and after the intervention. The experiments were performed 24 times in total for 8 times in each of the 3 periods. The unilateral neglect was measured using the Albert test, balance ability was measured using the Berg balance test, and the thickness of the lateral abdominal muscle was measured using ultrasound imaging. The subject was a 50-year-old male patient with unilateral neglect caused by right cerebral hemorrhage. He performed task-oriented training for a voluntary left trunk flexion pattern using real-time ultrasound imaging during the intervention period. Results: The result of comparing the data collected during the intervention period with the data point average of the baseline process showed that balance ability improved and the tendency line was above the baseline. The tendency line of unilateral neglect was below the baseline and showed a decreasing tendency. The thickness of the lateral abdominal muscle showed an increasing trend and the tendency line was above the baseline. Conclusion: The results of this study suggest that the task-oriented training for left trunk flexion pattern using real-time ultrasound imaging has a beneficial effect on balance ability, the degree of unilateral neglect, and the strength of the lateral abdominal muscle in unilateral neglect patients.