Recently, functional insoles of wedge-type it is for the young to raise their height inserted between insole and heel cause foot pain and disease. Additionally, these have a problem with stability and excessively load-bearing during gait like high-heel shoes. In this study, we compared the changes in biomechanical characteristics of foot with different insole thickness then we will utilize for the development of the insole with the purpose of relieving the pain and disease. Subjects(male, n = 6) measured COP(center of pressure) and PCP(peak contact pressure) on the treadmill(140cm/s) using F-scan system and different insole thickness(0~50 mm) between sole and plantar surface during gait. Also, we computed changes of stresses at the foot using finite element model with various insole thickness during toe-off phase. COP moved anterior and medial direction and, PCP was increased at medial forefoot surface, $1^{st}$ and $2^{nd}$ metatarsophalangeal, ($9%{\uparrow}$) with thicker insoles and it was show sensitive increment as the insole thickness was increased from 40 mm to 50 mm. Change of the stress at the soft-tissue of plantar surface, $1^{st}$ metatarsal head represents rapid growth($36%{\uparrow}$). Also, lateral moments were increased over the 100% near the $1^{st}$ metatarsal as the insole thickness was increased from 0 mm to 30 mm. And it is show sensitive increment as the insole thickness changed 10 mm to 20 mm. As a result, it was expected that use of excessively thick insoles might cause unwanted foot pain at the forefoot region. Therefore, insole thickness under 30 mm was selected.
Purpose: This study aimed to compare changes in abdominal muscle thickness in different standing postures with a handheld load between subjects with and without chronic low back pain (CLBP). Methods: Twenty subjects with CLBP and 20 controls participated in this study. Ultrasound imaging was used to assess the changes in the thickness of the transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) muscles. Muscle thickness in three different standing postures (standing at rest, standing with loads, standing with lifting loads) was compared with the muscle thickness at rest in the supine position and was expressed as a percentage of change in the thickness of the muscle. Results: While standing with loads, the change in IO muscle thickness in the CLBP patients increased more significantly than in the pain-free controls (p < 0.05). The standing with lifting loads posture showed a significant increase in the change in thickness of the TrA compared with the standing with loads posture (p < 0.05). In addition, the standing with lifting loads posture showed a significant decrease in the change in the thickness of the EO when compared with the standing with loads posture (p < 0.05). Conclusion: The automatic activity of the IO muscle in subjects with CLBP increased more than that of the pain-free controls in the standing with loads posture. These findings suggest that IO muscle function may be altered in those with CLBP while standing with loads. Additionally, TrA the activation level was found to be associated with increased postural demand caused by an elevated center of mass.
Background: The purpose of this study was to find out how changes in knee angles in stable and unstable support surfaces affect the muscle thickness of core muscles. Methods: The subjects of this study were 25 male adult. Each knee angle of 120, 90 and 60 degrees, they were performed bridge exercise on the stabilized surface and on the unstable support surface using TOGU, and measured the muscle thickness of the external and internal oblique muscle and the abdominal muscles through ultrasound images. Results: There was no significant difference between the thickness of the rectus abdominis and the internal oblique muscle depending on the support surface and the knee joint bending angles. However, there was a significant difference between the external oblique muscle and the transverse abdominis muscle by knee joint flexion angle. Conclusion: While the muscle thickness of the core muscle was not significantly affected by each support surface during the bridge exercise, there were significant changes in the core muscle as a result of changes in knee angle.
Purpose: This study examined the effect of vibration exercise on the thickness of the oblique extrinsic, oblique abdominal, and biceps muscles, which are trunk muscles, targeting children with spastic cerebral palsy. Methods: The participants in this study were 20 children (8 male and 12 female) with cerebral palsy aged 5-10 years. They were classified into two groups using a randomized allocation method, and the trunk muscle thickness was measured using an ultrasound-imaging device before and six weeks after the experiment. A paired t-test was used for the within-group changes, and an independent t-test was used for the inter-group changes. The significance level was set to α=0.05. Results: There was a significant increase in the inter-group change in the experimental group and control group in the intra-group change in the external oblique muscle and internal oblique muscle. After six weeks, there was a significant increase in the experimental group compared to the control group. Conclusion: Vibration exercise had a positive effect on the trunk muscle thickness of children with cerebral palsy. Vibration exercise produced a significant difference in the changes in the trunk muscle thickness in children with cerebral palsy compared to no vibration exercise. These results may provide basic data for future research and as a training method for strengthening the trunk muscles in clinical trials.
MDCT is used to determine how the noise changes as the slice thickness changes. Noise according to thickness of 1.5, 3.0, 5.0 and 10.0 mm was analyzed using the Siemens (Somatom Definition Flash, Germany) equipment and calibration conditions such as tube voltage and tube current using the calibration QC phantom. 1.5, 3.0, 5.0 and 10.0 mm, respectively. The mean HU was 1.5 mm (7.7 HU), 3.0 mm (4.9 HU) and was reduced by 59.5% from 1.5 mm. 5.0 mm (3.9 HU) and 97.6% compared to 1.5 mm, 10.0 mm (3.1 HU) and 148% less than 1.5 mm. It was found that as slice thickness increased, noise decreased, while slice thickness decreased. In conclusion, setting the appropriate slice thickness for each site may be useful for obtaining appropriate noise and image quality.
Ultrastructural changes in the cuticle of Paleamon serrifer associated with the intermolt cycle were examined and quantified as changes in the cuticular thickness. The cuticular thickness in each zoea stage increased with time elapsed after molting. The cuticle in the premolt stage was about 1.5 and 3 times thicker than that in the postmolt and intermolt stage, respectively. The cuticle in the premolt stage, including the molting space, was more than 5 times as thick as in the postmolt stage. In addition, newly hatched larvae were individually reared in the laboratory and body length for each specimen was measured frequently until the end of zoea VI. An average increase in body length between one zoea stage and the next is about $10\%$ of the length of the previous stage. Within individual zoea stages, the premolt stage had a body length some 0.3% longer than that of the postmolt stage, indicating a growth rate of about 0.03 mm/d.
Background: The purpose of this study is to investigate the effect of wall squat exercise according to the difference in the support surface on the thickness change of external oblique, internal oblique and transverse abdominalis of the trunk muscles and the change in distance of center of pressure when the eyes are opened and closed. Design: Randomized controlled trial. Methods: The subjects were 26 healthy adults, 18 males and 8 females. The composition of each group using the single-blind method was 13 people in the unstable side wall squat exercise group and 13 people in the stable side wall squat exercise group. Experimental measurements were divided into before, 3 weeks, and 6 weeks after the experiment, and changes in muscle thickness and balance were confirmed. Muscle thickness was measured using ultrasinic, and static balance change was measured using Bio-rescue. Results: There were significant differences in the thickness changes of external oblique, internal oblique and transverse abdominalis according to the wall squat exercise method by period and in the interaction between the period and the group (p<0.05). As a result of the post-hoc analysis, there was a significant difference in the change between the two groups in external oblique muscle after 6 weeks. And there was a significant difference in the distance of the pressure center between eyes open and closed eyes (p<0.05). Conclusion: In terms of instability, wall squat exercise was positive for changes in trunk muscle thickness. It suggests the possibility of using it for trunk muscle strengthening training in the future.
교정치료 후 연조직의 변화가 나타난다. 특히, 하안면부위에 많은 변화를 일으키게 되며, 대표적으로 입술은 치아 이동량의 $60\~70\%$정도 이동한다고 알려져 있다. 하지만, 이동량은 개인마다 그 양상이 다양하다. 본 연구는 환자의 입술두께에 따라 연조직 이동 양상에 차이가 있는지 여부를 조사하는데 그 목적이 있다. 발치를 동반한 교정치료를 받은 성인환자를 대상으로 basic upper lip thickness에 따라 환자를 분류한 결과, 두께가 얇은 군(group 1)에서 치료 후 연조직 변화에 영향을 미치는 요인으로는 mentolabial angle와 하순의 변화간에 음의 상관관계를 보였다. 두께가 평균인 군(group 2)에서 상순의 변화에 영향을 미치는 요소로는 상악전치의 변화, 하악전치의 변화, 하순의 변화, nasolabial angle의 변화로 나타났으며, 하순의 변화에 영향을 미치는 요소로는 상순의 변화, 상악전치의 변화, 하악전치의 변화로 나타났다. 두께가 두꺼운 군(group 3)에서 는 상순, 하순의 변화는 전치위치의 변화나 연조직 변화와는 관련 없음으로 관찰되었다.
Background: The purpose of this study is to examine the effect of push-up plus exercise on the changes in the thickness of the trapezius trapezius, serratus anterior and pectoralis major muscles involved in shoulder stability in various support surfaces. Design: Randomized controlled trial. Methods: The thickness change of the shoulder stabilizing muscle was measured using an ultrasound device. Corresponding t-test was performed to confirm the change within the group before the experiment and after 5 weeks. And one-way ANOVA was used to confirm the change between groups after 5 weeks. As a post hoc test, the least significant difference test was performed, and the significance level was set to a=0.05. Results: Changes in the thickness of the trapezius muscle within the group were significantly different between UPEG and SPEG after 5 weeks (p<0.05), and there was a significant difference between groups after 5 weeks (p<0.05). Changes in the thickness of the serratus anterior and pectoralis major muscle within the group were significantly different after 5 weeks in PEG, UPEG and SPEG (p<0.05), and the changes between the groups were significantly different in the serratus anterior muscle after 5 weeks (p<0.05). Conclusion: From the results of this study, it was found that the push-up exercise on an unstable support surface was effective for strengthening the trapezius upper and serratus anterior. This study intends to suggest the possibility of application as basic data for a push-up plus exercise program in clinical practice.
Organic light-emitting diode is quick response speed, low power consumption and the self-interest has many advantages, such as insanity. So, organic light-emitting diode mechanism of light-emitting diode in order to more clearly understand the changes in the thickness of emitting materials for OLED characteristics of the simulation. emitting layer to a thickness of 10 [nm] ~ 100 [nm] changed the experiment, and hole transport layer 190 [nm] as a fixed. and emitting layer 10 [nm] ~ 100 [nm] to change the simulation results. Changes in the thickness of emitting layer gradually increased. depending on the emitting was 20 [nm] in the high 441 [lm / W] shows. and was gradually reduced. emitting layer 190 [nm] when fixed, hole transport layer, depending on changes in the thickness of 70 [nm] in the efficiency maximum value of 477 [lm / W], and was gradually reduced.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.