• Title/Summary/Keyword: Thickness changes

Search Result 1,717, Processing Time 0.026 seconds

Comparison of the Effects of Plank and Kegel Exercises on Core Muscle Thickness (플랭크 운동과 케겔 운동이 코어 근육 두께에 미치는 효과 비교)

  • Bae, Wonsik;Ok, Jeongmin;Lim, Dogyun;Shin, Sol;Lee, Keoncheol
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.6 no.1
    • /
    • pp.91-98
    • /
    • 2018
  • Purpose : The aim of this study is to determine changes to the thickness of core muscles, e.g., transversus abdominis (TrA), external oblique (EO), and internal oblique (IO), after plank and Kegel exercises and to compare the effects of the two exercise methods. Method : The study divided men and women in their 20s into two groups, Kegel and plank, by randomly allocating 30 males and 30 females to the targeted groups. To achieve the purpose of this study, we examined the thickness of core muscles after the participants performed plank or Kegel exercises. Results : 1. In the Kegel group, abdominal muscle thickness increased with time, and there was a statistically significant difference in the thickness of the TrA. 2. In the plank group, abdominal muscle thickness increased with time, and there was a statistically significant difference in the thickness of the TrA. 3. After the experiment, muscle thickness of the abdominal muscles in the plank exercise group were higher, but there was no significant difference between the Kegel exercise group and the plank exercise group. Conclusion : Both plank and Kegel exercises are recommended for core muscle stabilization, and based on the results of this study, Kegel exercise is either used as a core stabilizing exercise or as a plank exercise for the weaker patients or women.

Intra- and inter-rater reliability of muscle thickness measurement of the tibialis anterior using different inward pressures

  • Lee, Seong-Joo;Lim, Ji Young;Lee, Chang-Hyung;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.4
    • /
    • pp.218-224
    • /
    • 2019
  • Objective: This reliability study examined the effects of applying varying induced inward pressures using a transducer placed at 0° neutral ankle position (NEU) and 15° ankle dorsiflexion (DF) on tibialis anterior (TA) muscle thickness using a custom-made device with a force indicator during rehabilitative ultrasound imaging. Design: Cross-sectional study. Methods: Twenty-four healthy subjects were recruited in this study. Two examiners measured the muscle thickness of the TA at 0° NEU and 15° DF in 3 conditions of inward pressures (1.0 N, 2.0 N, and 4.0 N) using a custom-made holder. The muscle thickness was measured three times for each of the conditions arranged in random order. For intra- and inter-rater reliability, the intraclass correlation coefficients (ICCs) with 95% confidence intervals, standard error of measurement, minimal detectable change, and coefficient of variation were analyzed. One-way repeated measures analysis of variance was conducted for investigating changes of TA muscle thickness according to the inward pressures of the transducers. Results: The intra-rater reliability of TA muscle thickness measurement was excellent (ICC3,1: 0.92-0.96) for all conditions (at both ankle joint angles per varying inward pressure). Likewise, the inter-rater reliability of TA muscle thickness measurement was excellent (ICC2,1: 0.89-0.97) under same conditions. The mean of TA thickness showed the trend of decreasing significantly with increased inward pressures at all ankle joint angles (p<0.05). Conclusions: Use of this custom-made device with a force indicator is useful to accomplish the high intra- and inter-rater reliability of TA muscle thickness measurement at both ankle joint angles in reducing the measurement error.

Influence of soft tissue and bone thickness on the dimensional change of peri-implant soft tissues;A clinical follow-up study (연조직 및 골 두께가 임플란트 주위 연조직 형태에 끼치는 영향에 관한 임상추적연구)

  • Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.1
    • /
    • pp.187-197
    • /
    • 2005
  • The aim of this study was to investigate the influence of peri-implant soft tissue and bone thickness on the early dimensional change of peri-implant soft tissue. Seventy-seven non-submerged implants of 39 patients which had been loaded more than 6 months were selected for the study. Following clinical parameters were measured; bucco-lingual bone width of the alveolar bone for implant placement before implant surgery; distance between implant shoulder and the first bone/implant contact at the surgery; presence of plaque, probing depth, bleeding on probing, width of keratinized mucosa, mucosa thickness, distance between implant shoulder and peri-implant mucosa, crown margin location at follow-up examination. The results showed that distance between implant shoulder and peri-implant mucosa (DIM) was correlated with probing depth and width of keratinized mucosa (p < 0.05). In addition, mucosa thickness was also correlated with probing depth (p<0.05). However, the bone width of alveolar bone and soft tissue thickness were not found to be correlated with DIM. It is important to understand the meaning of peri-implant tissue dimension in relation to dimensional changes of peri-implant soft tissue which designates appearance of implant-supported restorations. Future study is needed to elucidate the significance of the buccal bone thickness and soft tissue thickness with respect to the change of peri-implant soft tissue margin with the use of an instrument capable of measuring buccal bone thickness directly.

The Effects of Craniocervical Flexion Exercise on Deep Cervical Flexor Muscle Thickness and Gait for Children with Hemiplegic Cerebral Palsy (머리-목 굽힘 운동이 편측 뇌성마비 환자의 깊은 목 굽힘근의 두께와 보행에 미치는 영향)

  • Yun, Changkyo;Kim, HyunSung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.6 no.1
    • /
    • pp.99-105
    • /
    • 2018
  • Purpose : The purpose of this study was to evaluate the effect of craniocervical flexion exercise on deep cervical flexor thickness and gait in children with hemiplegic cerebral palsy. Methods : Twelve children with hemiplegic cerebral palsy were recruited for this study. All subjects performed active craniocervical flexion exercise 3times a week over the course of 6weeks. using a pressure bio feedback unit. Ultrasonography was used to assess deep cervical flexor thickness, and a 10m walking test was used to assess gait function. For the statistical analysis, a paired t-test was used to compare the differences pre- and post-value. SPSS Statistics version 20.0 was used for statistical analysis, and statistical significance was defined as a p-value less than 0.05. Result : The results of this study indicate that children with hemiplegic cerebral palsy experienced statistically significant positive changes in both deep cervical flexor thickness (p<.05). and gait(p<.05) following the intervention. Conclusion : In conclusion, craniocervical flexion exercise can positively affect deep cervical flexor thickness in children with hemiplegic cerebral palsy, which in turn positively affects gait.

Numerical simulation of the effect of bedding layer geometrical properties on the shear failure mechanism using PFC3D

  • Haeri, Hadi;Sarfarazi, Vahab;Zhu, Zheming;Marji, Mohammad Fatehi
    • Smart Structures and Systems
    • /
    • v.22 no.5
    • /
    • pp.611-620
    • /
    • 2018
  • In this research the effect of bedding layer angle and bedding layer thickness on the shear failure mechanism of concrete has been investigated using PFC3D. For this purpose, firstly calibration of PFC3d was performed using Brazilian tensile strength. Secondly shear test was performed on the bedding layer. Thickness of layers were 5 mm, 10 mm and 20 mm. in each thickness layer, layer angles changes from $0^{\circ}$ to $90^{\circ}$ with increment of $25^{\circ}$. Totally 15 model were simulated and tested by loading rate of 0.016 mm/s. The results shows that when layer angle is less than $50^{\circ}$, tensile cracks initiates between the layers and propagate till coalesce with model boundary. Its trace is too high. With increasing the layer angle, less layer mobilize in failure process. Also the failure trace is very short. It's to be note that number of cracks decrease with increasing the layer thickness. The minimum shear test strength was occurred when layer angle is more than $50^{\circ}$. The maximum value occurred in $0^{\circ}$. Also, the shear test tensile strength was increased by increasing the layer thickness.

Numerical simulation of the effect of bedding layer geometrical properties on the punch shear test using PFC3D

  • Haeri, Hadi;Sarfarazi, Vahab;Zhu, Zheming
    • Structural Engineering and Mechanics
    • /
    • v.68 no.4
    • /
    • pp.507-517
    • /
    • 2018
  • In this research the effect of bedding layer angle and bedding layer thickness on the shear failure mechanism of concrete has been investigated using PFC3D. For this purpose, firstly calibration of PFC3d was performed using Brazilian tensile strength. Secondly punch shear test was performed on the bedding layer. Thickness of layers were 5 mm, 10 mm and 20 mm. in each thickness layer, layer angles changes from $0^{\circ}$ to $90^{\circ}$ with increment of $25^{\circ}$. Totally 15 model were simulated and tested by loading rate of 0.016 mm/s. The results show that when layer angle is less than $50^{\circ}$, tensile cracks initiates between the layers and propagate till coalesce with model boundary. Its trace is too high. With increasing the layer angle, less layer mobilizes in failure process. Also, the failure trace is very short. It's to be note that number of cracks decrease with increasing the layer thickness. The minimum shear punch test strength was occurred when layer angle is more than $50^{\circ}$. The maximum value occurred in $0^{\circ}$. Also, the shear punch test tensile strength was increased by increasing the layer thickness.

Numerical Investigation of Thermo-Fluid Flow for Improvement of Micro-Dilution Chamber on Particulate Deposition (수치적 열유동 해석을 통한 마이크로 희석챔버의 개선)

  • Kim, Sung-Hoon;Lee, Dong-Ryul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.637-645
    • /
    • 2009
  • The main purpose of this study lies on the improvement of micro dilution tunnel based on the typical porous tube type chamber. The characteristics of flow and temperature fields for steady state has been obtained by numerical analysis using FLUENT. Three different geometrical variations of the porous tube; a) increase of thickness at center, b) step increase of thickness at center and downstream, c) tapered increase of thickness, have been proposed. Accordingly results are obtained and compared in terms of penetration velocity and velocity ratio to therrmophoretic velocity for improvement against particulate deposition inside the tube. The penetration velocity and velocity ratio distributions in the upstream portion and portion of impinging of dilution air are apparently shown to be improved for the case of the step and tapered change of porous tube. The tapered change of tube thickness addition are shown to be the most effective among three geometrical changes. In addition, the considerable improvement against deposition are shown that its thickness should be at least 2mm.

Health monitoring of steel structures using impedance of thickness modes at PZT patches

  • Park, Seunghee;Yun, Chung-Bang;Roh, Yongrae;Lee, Jong-Jae
    • Smart Structures and Systems
    • /
    • v.1 no.4
    • /
    • pp.339-353
    • /
    • 2005
  • This paper presents the results of a feasibility study on an impedance-based damage detection technique using thickness modes of piezoelectric (PZT) patches for steel structures. It is newly proposed to analyze the changes of the impedances of the thickness modes (frequency range > 1 MHz) at the PZT based on its resonant frequency shifts rather than those of the lateral modes (frequency range > 20 kHz) at the PZT based on its root mean square (RMS) deviations, since the former gives more significant variations in the resonant frequency shifts of the signals for identifying localities of small damages under the same measurement condition. In this paper, firstly, a numerical analysis was performed to understand the basics of the NDE technique using the impedance using an idealized 1-D electro-mechanical model consisting of a steel plate and a PZT patch. Then, experimental studies were carried out on two kinds of structural members of steel. Comparisons have been made between the results of crack detections using the thickness and lateral modes of the PZT patches.

Crystal structure and thermal properties of solution crystallized nylon 4,6 (용액 결정성장하의 Nylon 4,6 의 결정구조 및 열적성질)

  • 김연철;홍성권
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 1993.05a
    • /
    • pp.99-100
    • /
    • 1993
  • Calorimetric (D.S.C) studies were carried out on the nylon 4,6 single crystals grown from 1,4-butanediol solution at various crystallisation temperatures, based on the assessment of the lamellar thickness by small angle x-ray scattering. Samples were annealed mainly ot get rid of residual solvents inside the crystals. The effect of annealing on the crystal perfection is inferred from the measured thermal properties of the crystals. Accordig to the scanning rates less than 80 K/min., D. S C. melting peaks indicate that changes in the internal morphology of nylon 4,6 crystals preapred at different crystallisation temeratures yield a thermodynamic melting temperature. Tm, of 319 $^{\circ}C$, for the infinitely extended crystal thickness (1/ι). The obtained heat of fusion value for the inginite crystal thickness, Ho, was 270 J/g from the plot of measured feat of fusion ($\Delta$Hm) vs. reciprocal crystal thickness (1/ι). based on these values, the fold surface energy, $\delta$e. of 65.4 erg/$\textrm{cm}^2$ was obtained from Hoffman-Waeeks equation. The thermodynamic melting temperature and heat of fusion of the infinite crystal thickness for the solution grow nylon 4,6 single crystals are found to be higher than of the reported corresponding solution grown nylon 6,6 single crystals. pbtained crystallinity from D. S. C measurements ranges from 40 to 50 %, which is close to the reported yalue for the nylon 6,6 single ctystals but lower than we expected.

  • PDF

Relationship of fractures in coal with lithotype and thickness of coal lithotype

  • Pan, Jienan;Wang, Haichao;Wang, Kai;Niu, Qinghe
    • Geomechanics and Engineering
    • /
    • v.6 no.6
    • /
    • pp.613-624
    • /
    • 2014
  • The fractures in coal are the main migration and output channels of coalbed methane, directly influencing the permeability of the coal seams. It is of great significance to study the effect of fracture distribution in coals on the permeability of coal seam. The development rules of endogenetic and exogenetic fractures are different among various coal lithotypes. There is also difference in the fracture density for the same lithotype with different thicknesses. Through the observation and description of the macroscopic fractures in coal and the origin of fractures in coal, the effect of the coal lithotype and its thickness on fracture development in coal was discussed. It was found through the study that the density of fractures in vitrain band was the maximum for the same coal rank and thickness, followed by clarain band. There were few fractures developed in the durain band. However, the changes of fracture density in three types of bands presented different declining trends for low, medium and high coal rank. There were no fractures developed in the fusain. There were three variation patterns for the fracture densities at the same coal rank and coal lithotype: linear decrease, nonlinear decrease, and first decrease then remaining unchanged. However, the overall trend was that the fracture density decreased with the increase of thickness of coal band for the same coal rank and coal lithotype.