• Title/Summary/Keyword: Thickness Ratio

Search Result 3,803, Processing Time 0.035 seconds

Effects of varying nursery phase-feeding programs on growth performance of pigs during the nursery and subsequent grow-finish phases

  • Lee, Chai Hyun;Jung, Dae-Yun;Park, Man Jong;Lee, C. Young
    • Journal of Animal Science and Technology
    • /
    • v.56 no.7
    • /
    • pp.24.1-24.6
    • /
    • 2014
  • The present study investigated the effects of varying durations of nursery diets differing in percentages of milk products on growth performance of pigs during the nursery phase (NP) and subsequent grow-finish phase (GFP) to find the feasibility of reducing the use of nursery diets containing costly milk products. A total of 204 21-d-old weanling female and castrated male pigs were subjected to one of three nursery phase feeding programs differing in durations on the NP 1 and 2 and GFP diets containing 20%, 7%, and 0% lacrosse and 35%, 8%, and 0% dried whey, respectively, in 6 pens (experimental units) for 33 d: HIGH (NP 1, 2 and 3 diets for 7, 14, and 12 d), MEDIUM (NP 2 and 3 for 14 and 19 d), and LOW (NP 2 and 3 and GFP 1 for 7, 14, and 12 d). Subsequently, 84 randomly selected pigs [14 pigs (replicates)/pen] were fed the GFP 1, 2 and 3 diets during d 54-96, 96-135, and 135-182 of age, respectively. The final body weight (BW) and average daily gain (ADG) of nursery pigs did not differ among the HIGH, MEDIUM, and LOW groups (14.8, 13.3, and 13.7 kg in BW and 273, 225, and 237 g in ADG, respectively). The average daily feed intake during the nursery phase was greater (p < 0.01) in the HIGH group than in the MEDIUM and LOW groups, whereas the gain:feed ratio did not differ across the treatments. The BW on d 182 and ADG during d 54-182 were greater in the HIGH and MEDIUM groups vs. the LOW group (110.0, 107.6, and 99.6 kg in BW, respectively; p < 0.01). The backfat thickness and carcass grade at slaughter on d 183 did not differ across the treatments. In conclusion, the MEDIUM program may be inferior to the commonly used HIGH program in supporting nursery pig growth. Nevertheless, the former appears to be more efficient than the latter in production cost per market pig whereas the LOW program is thought to be inefficient because of its negative effect on post-nursery pig growth.

For High Aspect Ratio of Conductive Line by Using Alignment System in Micro Patterning of Inkjet Industry (화상정렬 시스템을 이용한 잉크젯 반복인쇄기술)

  • Park, Jae-Chan;Park, Sung-Jun;Seo, Shang-Hoon;Joung, Jae-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.154-154
    • /
    • 2006
  • Samsung Electro Mechanics ink jet has developed ultra high resolution alignment system. The alignment system has been developed for repeatable printing of conductive ink. The resolution of alignment system is 0.5um and the velocity of printing working plate is 1.5m/s. So far repeated printing results included sintering process have over 30um of drop mislocation data. In order to improve line thickness and conductivity of metal line, we need to develop the higher mechanical accurate align system. On the demand, this developed align system has under $1{\sim}2{\mu}m$ mispositioning performance and can measure of mechanical accuracy of inkjet printer, as well as the straightness of jetted drop from inkjet head. There is no kinds limit of substrate and ink to use SEM alignment system. By using this alignment system, we progress two experiment of reiterate printing drop and making conductive line on the glass and photo paper. Optical microscope and 3D profiler has been used for measurement of printed ink.

  • PDF

A Study on Radiographical Conditions and Exposure Doses During Chest Radiography at Medical Facilities in Pusan (부산지역 의료기관의 흉부촬영 조건과 피폭선량에 관한 조사연구)

  • Jeon, Sung-Oh;Cho, Young-Ha
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.49-55
    • /
    • 1997
  • This study was carried out to investigate radiographical and operating conditions of X-ray units and exposure doses to patients during chest radiography, so that the results could provide basic data used for reducing the exposure dose and for providing the diagnostic information with better quality. The conditions and exposure doses of 100 X-ray units mainly used for chest radiography were examined and also 100 radiological technologists mainly handling those apparatus at 76 medical facilities in Pusan were surveyed using a questionnaire from October 1 to December 31 in 1995. The following results were obtained from the study : 1. It was found that most units were capable of taking a high tube voltage radiography by showing 67% of the units equipped with the maximum tube voltage of 150 kV, 94% with more than 500 mA for the rating capacity and 85% with the full wave type of a signal phase. 2. For actual chest radiographical conditions, however, 80% of the units were operated at $60{\sim}100\;kVp$ and only 14% at 100 kVp and over for the high tube voltage. 3. The average exposure time was less than 0.1 second, and eighty four percent of the units adapted the X-ray tube currents ranging from 200 to 300 mA, 80% the focus-film distances between 180 and 210 cm, and 63% the focus sizes of more than 2.0 mm. 4. Most units(98%) employed additional filters made of aluminum, 75% the thickness of filters less than 2.0 mm, and only 2 units the compound filters. 5. Ortho chromatic system was only adopted in 13% of screen film system for the units, and 73% used the grid ratio at 8 : 1 for the low tube voltage during chest radiography. 6. The average exposure dose of all X-ray units during chest radiography was $371\;{\mu}Sv$ with a difference of about 16 times between the minimum to the maximum, and $386\;{\mu}Sv$ both at hospitals and at health centers, followed by $380\;{\mu}Sv$ at general hospitals and $263\;{\mu}Sv$ at university hospitals without showing any statistically significant differences. In conclusion, since patients during chest radiography at medical facilities in Pusan exposed to high levels of radiation, it is recommended that appropriate added filters and grids necessary for the high tube voltage radiography and high-speed screen systems should be adopted and used as soon as possible in order to reduce exposure dose to the patients.

  • PDF

Study on the Improved Abrasion Resistance of Polycarbonate Substrate by UV-curable Organic/Inorganic Hybrid Coatings (자외선 경화형 유기/무기 복합코팅에 의한 폴리카보네이트의 내마모성 향상 연구)

  • 윤석은;우희권;김동표
    • Polymer(Korea)
    • /
    • v.24 no.3
    • /
    • pp.389-398
    • /
    • 2000
  • Transparent, abrasion resistant coatings with 4~13 ${\mu}{\textrm}{m}$ thickness were prepared by spin-coating on polycarbonates with organic/inorganic hybrid solutions, followed by UV curing and heat treatment at 12$0^{\circ}C$ for 12 hours. The coating solutions were composed of inorganic phase and organic phase in 0:100, 20:80, 30:70, 50:50, 80:20 wt% ratios, respectively, mixed with photoinitiator, senaitizer and surfactant. The inorganic phase was formed by sol-gel reaction of TEOS and silane coupling agent MPTMS in 1 : 2 or 2 : 1 molar ratios, the organic phase consisted of difunctional urethane acrylate oligomeric resin, multifunctional acrylate TMPTA and HDDA in 4 : 3 : 3 wt% ratio. The coating systems were investigated by FT-IR, $^{29}$ Si-NMR spectra. In addition, TGA/DSC for thermal analysis and SEM, AFM observation for coated surface were examined. Gererally, the homogeneity of phases, the surface smoothness of coating and abrasion resistance were improved with the higher content of inorganic component. Namely, coating system with below 10 $\AA$ surface roughness and T$_{g}$ of 15$0^{\circ}C$ showed only 10% decrease in light transmittance after abrasion test, whereas uncoated polycarbonate substrate exhibited 46% decrease..

  • PDF

Studies on the Performance of Korean Native Chickens II. A Comparison of Performance of Various Korean Native Chickens (한국재래닭의 능력에 관한 연구 II. 한국재래닭의 계통별 능력 비교)

  • 김상호;이상진;강보석;최철환;장병귀;오봉국
    • Korean Journal of Poultry Science
    • /
    • v.25 no.4
    • /
    • pp.177-183
    • /
    • 1998
  • A feeding trial was conducted to investigate the performance of various Korean Native Chickens (KNC) for 64 weeks. Eight hundreds and ten KNC one-day birds were arranged to three strains, Dark Brown(D), Light Brown(L) and Black(B). Each strain had three replicates of 90 birds a replicate. Birds fed same diet with Korean standard feeding. Data were obtained growing performance to 20 week of age and laying performance from twenty one to sixty four week. During the growing stage from hatch to 20 week of age, there were not significant difference to three strains on viability, body weight and feed intake. L strain tended to be earlier 50% egg production day than that of other strains, but was not significantly different. Egg production of L strain was the highest of strains. It showed significantly higher egg production compared to that of D strain(P<0.05), but was not statistically different from that of B strain. Laying peak period was between 28 to 32 week of age in all strains, Egg weight was heavier in D strain(P<0.05). Feed intake was the same as 105g, and feed conversion improved in L strain(P<0.05). There were not difference on interior egg and eggshell quality by strains although eggshell thickness improved slightly in D strain. Fertility of D strain was the highest compared to others(P<0.05) regardless laying stages. Hatchability was not influenced by strains at 39 weeks old, but was significantly higher in B strain at 62 week of age(P< 0.05). The results of this experiment indicated that KNC 3 strains were not effect on egg production, feed intake and feed conversion ratio.

  • PDF

LiF TLD in TLD Holder for In Vivo Dosimetry (생체 내 선량측정을 위한, TLD홀더에 넣은 LiF TLD)

  • Kim Sookil;Loh John J.K.;Min Byungnim
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.293-299
    • /
    • 2001
  • Prupose : LiF TLD has a problem to be used in vivo dosimetry because of the toxic property of LiF. The aim of this study is to develop new dosimeter with LiF TLD to be used in vivo dosimetry. Materials and methods : We designed and manufactured the teflon box(here after TLD holder) to put TLD in. The external size of TLD holder is $4\times4\times1\;mm^3$ To estimate the effect of TLD holder on TLD response for radiation, the linearity of TLD response to nominal dose were measured for TLD in TLD holder. Measurement were peformed in the 10 MV x-ray beam with LiF TLD using a solid water phantom at SSD of 100 cm. Percent Depth Dose (PDD) and Tissue-Maximum Ratio (TMR) with varying phantom thickness on TLD were measured to find the effect of TLD holder on the dose coefficient used for dose calculation in radiation therapy. Results : The linearity of response of TLD in TLD holder to the nominal dose was improved than TLD only used as dosimeter And in various measurement conditions, it makes a marginnal difference between TLD in TLD holder and TLD only in their responses. Conclusion : It was proven that the TLD in TLD holder as a new dosimetry could be used in vivo dosimetry.

  • PDF

Effects of Growth Temperature on Hydrothermally Grown ZnO Nanorod Arrays (수열합성법으로 성장된 산화 아연 나노로드의 성장 온도에 따른 구조적, 광학적 특성 연구)

  • Jeong, Yong-Il;Ryu, Hyuk-Hyun
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.3
    • /
    • pp.211-216
    • /
    • 2011
  • In this study, the effects of growth temperature on structural and optical properties of hydrothermally grown ZnO nanorod arrays have been investigated. Zinc nitrate ($Zn(NO_3)_2$) and hexamethylenetetramine were used as precursors. The ZnO buffered Si(100) with a thickness of 40 nm was used as the substrates. The ZnO nanorods were grown on these substrates with the temperature ranging from 55 to $115^{\circ}C$. The results were characterized by scanning electron microscope, X-ray diffraction and room temperature photoluminescence measurements. Well-aligned ZnO nanorods arrays were obtained from all samples. The tips of nanorods were flat when the temperature was less than $95^{\circ}C$, and the sharp-tip nanoneedle-like morphologies were obtained with the temperature of $115^{\circ}C$. In addition, some bundles were on the nanorods arrays with $115^{\circ}C$ due to the non-equilibrium growth. The growth temperature could affect the crystal and optical properties of ZnO. For the effects on crystal properties, the intensity of (002) peak was increased as the temperature was increased to $75^{\circ}C$, then decreased as the temperature was further increased to $115^{\circ}C$. As for the effects on optical properties, the intensity ratio of UV peak to visible peak is increased with the temperature increasing and the strongest UV peak intensity was obtained with the growth temperature of $95^{\circ}C$.

Fabrication of Large Area Transmission Electro-Absorption Modulator with High Uniformity Backside Etching

  • Lee, Soo Kyung;Na, Byung Hoon;Choi, Hee Ju;Ju, Gun Wu;Jeon, Jin Myeong;Cho, Yong Chul;Park, Yong Hwa;Park, Chang Young;Lee, Yong Tak
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.220-220
    • /
    • 2013
  • Surface-normal transmission electro-absorption modulator (EAM) are attractive for high-definition (HD) three-dimensional (3D) imaging application due to its features such as small system volume and simple epitaxial structure [1,2]. However, EAM in order to be used for HD 3D imaging system requires uniform modulation performance over large area. To achieve highly uniform modulation performance of EAM at the operating wavelength of 850 nm, it is extremely important to remove the GaAs substrate over large area since GaAs material has high absorption coefficient below 870 nm which corresponds to band-edge energy of GaAs (1.424 eV). In this study, we propose and experimentally demonstrate a transmission EAM in which highly selective backside etching methods which include lapping, dry etching and wet etching is carried out to remove the GaAs substrate for achieving highly uniform modulation performance. First, lapping process on GaAs substrate was carried out for different lapping speeds (5 rpm, 7 rpm, 10 rpm) and the thickness was measured over different areas of surface. For a lapping speed of 5 rpm, a highly uniform surface over a large area ($2{\times}1\;mm^2$) was obtained. Second, optimization of inductive coupled plasma-reactive ion etching (ICP-RIE) was carried out to achieve anisotropy and high etch rate. The dry etching carried out using a gas mixture of SiCl4 and Ar, each having a flow rate of 10 sccm and 40 sccm, respectively with an RF power of 50 W, ICP power of 400 W and chamber pressure of 2 mTorr was the optimum etching condition. Last, the rest of GaAs substrate was successfully removed by highly selective backside wet etching with pH adjusted solution of citric acid and hydrogen peroxide. Citric acid/hydrogen peroxide etching solution having a volume ratio of 5:1 was the best etching condition which provides not only high selectivity of 235:1 between GaAs and AlAs but also good etching profile [3]. The fabricated transmission EAM array have an amplitude modulation of more than 50% at the bias voltage of -9 V and maintains high uniformity of >90% over large area ($2{\times}1\;mm^2$). These results show that the fabricated transmission EAM with substrate removed is an excellent candidate to be used as an optical shutter for HD 3D imaging application.

  • PDF

Comparison of International Guidelines of Dermal Absorption Tests Used in Pesticides Exposure Assessment for Operators

  • So, Jaehwan;Ahn, Junyoung;Lee, Tae-Hee;Park, Kyung-Hun;Paik, Min-Kyoung;Jeong, Mihye;Cho, Myung-Haing;Jeong, Sang-Hee
    • Toxicological Research
    • /
    • v.30 no.4
    • /
    • pp.251-260
    • /
    • 2014
  • The number of farmers who have suffered from non-fatal acute pesticide poisoning has been reported to vary from 5.7% to 86.7% in South Korea since 1975. Absorption through the skin is the main route of exposure to pesticides for farmers who operate with them. Several in vitro tests using the skins of humans or animal and in vivo tests using laboratory animals are introduced for the assessment of human dermal absorption level of pesticides. The objective of this study is to evaluate and compare international guidelines and strategies of dermal absorption assessments and to propose unique approaches for applications into pesticide registration process in our situation. Until present in our situation, pesticide exposure level to operator is determined just using default value of 10 as for skin absorption ratio because of data shortage. Dermal absorption tests are requested to get exposure level of pesticides and to ultimately know the safety of pesticides for operators through the comparison with the value of AOEL. When the exposure level is higher than AOEL, the pesticide cannot be approved. We reviewed the skin absorption test guidelines recommended by OECD, EFSA and EPA. The EPA recommends assessment of skin absorption of pesticides for humans through the TPA which includes all the results of in vitro human and animal and animal in vivo skin absorption studies. OECD and EFSA, employ a tiered approach, which the requirement of further study depends on the results of the former stage study. OECD guidelines accept the analysis of pesticide level absorbed through skin without radioisotope when the recovery using the non-labeled method is within 80~120%. Various factors are reviewed in this study, including the origin of skin (gender, animal species and sites of skin), thickness, temperature and, etc., which can influence the integrity of results.

Development of an EMAT System for Detecting flaws in Pipeline (배관결함 검출을 위한 EMAT 시스템 개발)

  • Ahn, Bong-Young;Kim, Young-Joo;Kim, Young-Gil;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.1
    • /
    • pp.15-21
    • /
    • 2004
  • It is possible to detect flaws in pipelines without interruption using all EMAT transducer because it is a non-contact transducer which can transmit ultrasonic waves into specimens without couplant. And it ran easily generate guided waves desired in each specific problem by altering the design of coil and magnet. In the present work, EMAT systems have been fabricated to generate surface waves, and selectively the plate wave of $A_1\;or\;S_1$ mode. The surface wave of 1.5MHz showed a good signal-to-noise ratio without distortion in its propagation along a pipeline, while the $S_1$ mode of 800kHz and the $A_1$ mode of 940kHz were distorted according to their dispersive properties. The wider the excitation pulse becomes, the better the mode selectivity of the plate waves becomes. A pipe of 256mm inner diameter and 5.5m thickness with 5 flaws was used for comparing the flaw detectability among the modes under consideration.