• Title/Summary/Keyword: Thickness Measurement Error

Search Result 126, Processing Time 0.025 seconds

Design of Color Matching Filters and Error Analysis in Colorimetric Measurement of LCD Flat Panel Display Using the Filters (등색함수 필터의 설계와 이를 이용한 LCD 평판 디스플레이의 색채 측정에 대한 오차 분석)

  • Jeon, Ji-Ho;Jo, Jae-Heung;Park, Seung-Nam;Park, Chul-Woung;Lee, Dong-Hoon;Jung, Ki-Lyong
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • Filter colorimeters have a set of spectral bands for which spectral responsivity is the same as the color matching function defined by CIE (Commission Internationale de I'Eclairage). We have designed a set of color matching function filters denoted by $\bar{x}-filter,\;\bar{y}-filter,\;and\;\bar{z}-filter$. Because the $\bar{x}-function$ has two transmission bands, two $\bar{x}-filters$ are designed to cover the $\bar{x}-function$. To design the filters, we developed a nonlinear least square fit program which determines the thickness of the color glasses by minimizing its spectral mismatch value ($f{_1}'$) to below 3 %. The design has been validated by fabrication of the $\bar{y}-bar$ filter, of which $f{_1}'$ was measured to be 2.8 %. Considering a LCD flat panel display as a device under test, we have calculated the systematic error of the colorimetric measurement using the designed filters.

A Study on Estimation of Carotid Intima-Media Thickness(IMT) using Pulse Wave Velocity(PWV) (맥파전달속도를 이용한 내중막 두께 추정에 관한 연구)

  • Song, Sang-Ha;Jang, Seung-Jin;Kim, Wuon-Shik;Lee, Hyun-Sook;Yoon, Young-Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.5
    • /
    • pp.401-411
    • /
    • 2009
  • In this paper, we correct pulse wave velocity(PWV) with heart-rate and derive regression equations to estimate intima-media thickness(IMT). Widely used methods for diagnosis of arteriosclerosis are IMT and PWV. Arterial wall stiffness determines the degree of energy absorbed by the elastic aorta and its recoil in diastole but there is not correlation between sclerosis and IMT in an existing study. In this study, we will correct PWV with heart-rate and get regression equation to estimate IMT using heart-rate correction index(HCI). We executed experiments for this study. Made up question of physical condition and measured electrocardiogram(ECG), photoplethysmogram (PPG) of finger-tip and toe-tip and ultrasound image of carotid artery. Calculated PWV and IMT using ECG, PPG and ultrasound image. We found that every p-value between PWV and IMT is not significant(<0.05). But p-value between IMT and HCI which is a corrected PWV using heart-rate is significant(>0.01). We use HCI and various measured parameter for estimating regression equation and apply backward estimation to select parameters for regression analysis. Result of backward estimation, found that only HCI is possible to derive proper regression equation of IMT. Relationship between PWV and IMT is the second order. Result of regression equation of E-H PWV is $R^2$=0.735, adj $R^2$=0.711. This is the best correlation value. We calculate error of its analysis for verification of earlobe PWV regression equation. Its result is RMSEP=0.0328, MAPE(%) = 4.7622. Like this regression analysis, we know that HCI is useful parameter and relationship between PWV, HCI and IMT. In addition, we are able to suggest possibility which is that we can get different parameter of prediction throughout just one measurement.

The Changes of The Eye and a Correlation Depending on Watching a Smartphone and taking in Alcohol (스마트폰 시청과 알코올 섭취에 따른 눈의 변화와 상관관계)

  • Lee, Jeong-Yun;Yun, Eon-Jeong;Kim, Sung-Min;Hwang, Hye-Kyung;Park, Gyeung-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.473-479
    • /
    • 2013
  • Purpose: This article tried to find the changes of the eye and a correlation depending on watching a smartphone and taking in alcohol. Methods: This paper conducted the refraction inspection, the radius of corneal curvature, tonometry and the corneal thickness measurement and analysis for 31 persons (18 males and 13 females) who have healthy drinking habit, not having the medical history of taking medicine related with disorders of the eye, a mental disease, systemic disease and alcohol metabolism. Results: Of respirations depending on watching a smartphone, the alcohol concentration was significantly decreased in 15 minutes, 30 minutes, 45 minutes, 60 minutes and the convalescent stage. (p<0.01, p<0.001) As the result of comparing the refraction inspection after and before watching a smartphone when drinking alcohol, there was a significant difference in the cylindrical power and the axis. (p=0.005, p=0.001) The change of intraocular pressure depending on watching a smartphone after drinking alcohol was decreased significantly from 30 minutes (p<0.001), and watching a smartphone didn't have any significant effect on the corneal thickness depending on the elapsed time from when drinking alcohol. Conclusions: Watching a smartphone and taking in alcohol had a significant effect on the cylindrical power and the axis. Watching a smartphone and taking in alcohol which may cause the visual function-strain are the factors that need to consider before the refraction inspection.

Target Localization and Dose Delivery Verification used a Water Phantom in Stereotactic Radiosurgery (정위적 방사선 수술에서 물팬텀을 이용한 목표점 및 전달 선량확인)

  • Kang, Young-Nam;Lee, Dong-Jun;Kwon, Soo-Il;Kwon, Yang
    • Progress in Medical Physics
    • /
    • v.7 no.2
    • /
    • pp.19-28
    • /
    • 1996
  • It is important that the precise decision of the region and the accurate delivery of radiation dose required for treatment in the stereotactic radiosurgery. In this research, radiosurgery was carried with Leksell streotactic frame(LSF) which is especially developed water phantom to verify in experiment. Leksell Gamma Knife and LSF are used in radiosurgery is the spherical water phantom has the thickness of 2 mm, the radius of 160mm. The film for target localization and ionchamber for dose delivery was used in measurement instruments We compare the coordinate of target which is initialized by biplannar film with simple X-ray to the coordinate of film measured directly. The calculated dose by computer simulation and the measured dose by ionization chamber are compared. In this research, the target localization has the range ${\pm}$0.3mm for the acceptable error range and the absolute dose is :${\pm}$0.3mm for the acceptable error range. This research shows that the values measured by using the especially manufactured phantom are included the acceptable error range. Thus, this water phantom will be used continuously in the periodic quality assurance of Gamma Knife Unit and Leksell Stereotactic Frame.

  • PDF

Development of Differential Diagnosis and Treatment Method of Reproductive Disorders Using Ultrasonography in Cows II. Differential Diagnosis of Subestrous Dairy Cows (초음파검사에 의한 소의 번식장애 감별진단 및 치료법 개발 II. 무발정우의 감별진단)

  • 강병규;최한선;강현구;오기석;서동호;손창호;서국현
    • Journal of Veterinary Clinics
    • /
    • v.15 no.2
    • /
    • pp.307-318
    • /
    • 1998
  • Accuracy of rectal palpation and ultrasonography for differential diagnosis of subestrous dairy trows were investigatedl using the result of pIRsma progesterone assay. The ovaries were examined 2 times of 10 days interval in 520 posearom and postinsemination subestroHs dairy cows, using rectal palpation and B-mode transrectal ultrasonography. The results of rectal palpation, ultrasonographic examination and measurement of plasma progesterone profiles in 520 subestrous dairy cows were silent brat or error of estrus detection 303 (58.3%), persistent corpus luteum 59 (11.3%), follicular cyst 37 (7.1%), luteal cyst 16 (3.1%), inactive ovary 9 (1.7%), granulosa tumor 1 (0.2%), hydmsalphinx 1 (0.2%), endomehris 81 (15.6%), pyometra 12 (2.3%) and mummified fetus 1 (0.2%), respectively. Accuncy of rectal palpation and ultrasonography for diagiosing ovarian disordeir based on plasma progesterone profiles were silent heat or error of estrus detection 80.5% and 96.7%$\boxUl$ persistent corpus luteum 57.6% and 94.9%, follicular cyst 62.5% and 91.9%1 luteal cyst 62.5% and 87.5%, maclive ovary 55.6% and 88.9% and granulosa cell tumor 100% and 100%, respectively. Acnuucy of rectal palpation for diagnosing uterine disorders based on ultrasonography was pyometra 75.0%1 endometritis 51.9% and mummified fetus 100%, respectively. Cbaracteristic ultrasonographic appearances of ovaries in subestrous dairy cows were as follows; Silent heat or error of estrus detection: anechoic follicle or hypoechoic corpus luteum than ovarian stroma was alternately present on Day 0 (first examination) and Day 10. Follicular cyst: uniformly nonechogenic ovarian structure $\geq $ 25 mm in diameter with a wall < 3 mm was present in ipsilateral on Day 0 and Day 10. Luteal cyst: luteal cyst was similar to follicular cysts but thickness of cystic wall was $\geq $ 3 mm. Inactive ovary : structures within ovaries was not present on Day 0 Bnd Day 10. Characteristic uthssonograpsc appearances of uterus in subestrous dairy cows were as follows; Endometritis: characterized by uterine lumen containing fluid in which 'snowy'echogenic particles art suspended. Pyometra: ultrasonographic appearance of pyometra was diffuse echogenic particles distributed in fluid within the distended uterus, and a thickened uterine wall. These results indicated that ultrasonography was practical far diagnosing reproductive disorders. To diagnosing ovarian disorders, ultrasonography should be carried out 2 times of 10 days interval and rndometritis should be differentiated with uterus of luteal phase in normal cycling cows.

  • PDF

A $2{\times}2$ Microstrip Patch Antenna Array for Moisture Content Measurement of Paddy Rice (산물벼 함수율 측정을 위한 $2{\times}2$ 마이크로스트립 패치 안테나 개발)

  • 김기복;김종헌;노상하
    • Journal of Biosystems Engineering
    • /
    • v.25 no.2
    • /
    • pp.97-106
    • /
    • 2000
  • To develop the grain moisture meter using microwave free space transmission technique, a 10.5GHz microwave signal with the power of 11mW generated by an oscillar with a dielectric resonator is transmitted to an isolator and radiated from a transmitting $2{\times}2$ microstrip patch array antenna into the sample holder filled with the 12 to 26%w.b. of Korean Hwawung paddy rice. the microwave signal, attenuated through the grain with moisture, is collected by a receiving $2{\times}2$ microstrip patch array antenna and detected using a Shottky diode with excellent high frequency characteristic. A pair of light and simple microstrip patch array antenna for measurement of grain moisture content is designed and implemented on atenflon substrate with trleative dielectric constant of 2.6 and thickness of 0.54 by using Ensemble ver. 4.02 software. The aperture of microstrip patch arrays is 41 mm width and 24mm high. The characteristics of microstrip patch antenna such as grain. return loss, and bandwidth are 11.35dBi, -38dB and 0.35GHz($50^{\circ}$ at far-field pattern of E and H plane. The width of the sample holder is large enough to cover the signal between the antennas temperature and bulk density respectively. The calibration model for measurement of grain moisture content is proposed to reduce the effects of fluectuations in bulk density and temperature which give serious errors for the measurements . From the results of regression analysis using the statistically analysis method, the moisture content of grain samples (MC(%)) is expressed in terms of the output voltage(v), temperature (t), and bulk density of samples(${\rho}b$)as follows ;$$MC(%)\;=\;(-3.9838{\times}10^{-8}{\times}v^{3}+8.023{\times}10^{-6}{\times}v^{2}-0.0011{\times}v-0.0004{\times}t+0.1706){\frac{1}{{\rho}b}}{\times}100$ Its determination coefficient, standard error of prediction(SEP) and bias were found to be 0.9855, 0.479%w.b. and -0.0.369 %w.b. respectively between measured and predicted moisture contents of the grain samples.

  • PDF

Evaluation of Shielding Performance of Tungsten Containing 3D Printing Materials for High-energy Electron Radiation Therapy (고에너지 전자선 치료 시 텅스텐 함유 3D 프린팅 물질의 차폐 성능 평가)

  • Yong-In Cho;Jung-Hoon Kim;Sang-Il Bae
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.641-649
    • /
    • 2023
  • This study compares and analyzes the performance of a shield manufactured using 3D printing technology to find out its applicability as a shield in high-energy electron beam therapy. Actual measurement and monte carlo simulations were performed to evaluate the shielding performance of 3D printing materials for high-energy electron beams. First, in order to secure reliability for the simulation, a source term evaluation was conducted by referring to the IAEA's TRS-398 recommendation. Second, to analyze the shielding performance of PLA+W (93%), a specimen was manufactured using a 3D printer, and the shielding rate by thickness according to electron beam energy was evaluated. Third, the shielding thickness required for electron beam treatment was calculated through a comparative analysis of shielding performance between PLA+W (93%) and existing shielding bodies. First, as a result of the evaluation of the source term through actual measurement and simulation, the TRS-398 recommendation was satisfied with an error of less than 1%, thereby securing the reliability of the simulation. Second, as a result of the shielding performance analysis for PLA+W (93%), 6 MeV electron beams showed a shielding rate of more than 95% at 3.12 mm, and 15 MeV electron beams showed a shielding rate of more than 90% at 10 mm thickness. Third, through simulations, comparative analysis between PLA+W (93%) materials and existing shields showed high shielding rates within the same thickness in the order of tungsten, lead, copper, PLA+W (93%), and aluminum. 6 MeV electron beams showed almost similar shielding rates at 5 mm or more and 15 MeV electron beams. Through this study in the future, it is judged that it can be used as basic data for the production and application of shielding bodies using PLA+W (93%) materials in high-energy electron beam treatment.

Laboratory Determination of Compressional wave Velocity for Unconsolidated Marine Sediment (미고결 해저퇴적물의 음파전달속도 측정에 관한 연구)

  • KIM Dae-Choul
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.22 no.3
    • /
    • pp.147-153
    • /
    • 1989
  • Laboratory measurement of compressional wave velocity for two piston cores has been carried out successfully. The cores penetrated into the Holocene mud deposit located just off the Pusan harbor. Differences between the mercury delay method using a mercury column and the time delay method utilizing a digital processing oscilloscope for the observed velocity are negligible. Thus, both methods can be used independently to determine the velocity of unconsolidated marine sediment. The core velocity is, however, always higher than the velocity calculated from the seismic profile. This result should be considered seriously to interprete a seismic profile, otherwise one may encounter systematic error in calculating sediment thickness.

  • PDF

A Study on the Reliability of Detecting Reinforcement Embedded in Concrete in Various Factors Using Electromagnetic Induction Method and Electromagnetic Wave Method (전자기유도법과 전자파레이더법을 이용한 각종인자에 따른 철근탐사의 신뢰성에 관한 연구)

  • Kim, Jong-Ho;Oh, Kwang-Chin;Park, Seung-Bum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.4
    • /
    • pp.179-186
    • /
    • 2008
  • Probing inside of concrete structures is one of the important steps in assessing condition of the structure. For the assessment, electromagnetic induction method and electromagnetic wave method are currently applied to the measurement of cover depth, and the detection of reinforcement embedded in concrete. To determine detection capability of locating reinforcement embedded in concrete, commercially available nondestructive testing (NDT) equipments have been tested. The equipments include electromagnetic wave system and electromagnetic induction system. In the tests, nine concrete specimens which have the dimensions of 1,000mm(length))${\times}$300mm(width) with thickness varying from 125mm to 150mm are used. The reinforcement are located at 45, 60, 100mm depth from the concrete surface. Horizontal reinforcement spacing has been set over 100mm. From the outcome, it is shown that error is increased as the diameter of reinforcement enlarge in case of using electromagnetic induction method. In case of using electromagnetic wave method, the detection of reinforcement embedded in deep is good in the view of reliability because of using the relative permittivity on the real cover depth.

Design & Fabrication of a Feedforward Power Amplifier for 900 MHz Band RFID Readers (900 MHz 대역 RFID 리더기용 Feedforward형 선형 전력 증폭기 설계 및 제작)

  • Jung, Byoung-Hee;Chae, Gyu-Sung;Kim, Chang-Woo
    • Journal of Advanced Navigation Technology
    • /
    • v.8 no.2
    • /
    • pp.184-190
    • /
    • 2004
  • A feedforward linear power amplifier (FLPA) has been developed for UHF-band RFID reader applications. The main and error amplifiers are composed of a 2 stage so that linearity of the FLPA can be improved. The FLPA has been implemented on an FR-4 substrate (Er=4.7 and thickness=0.8 mm) with 3-dB and 10-dB hybrid couplers for input/output power divider and combiner. For 2-tone measurement (input level=-11 dBm at $f_1$=915 MHz and $f_2$=916 MHz), the FLPA exhibits a -18.52 dBm of $IMD_3$, which indicates that $IMD_3$ cancellation with feedforward loop is more than 27 dB. From 890 to 960 MHz, 1-dB gain compression output power and power gain of the FLPA are higher than 30 dBm and 40 dB, respectively.

  • PDF