• Title/Summary/Keyword: Thickness Error

Search Result 507, Processing Time 0.032 seconds

Analysis of Accelerated Soft Error Rate for Characteristic Parameters on Static RAM (정적 RAM 특성 요소에 의한 소프트 에러율의 해석)

  • Gong, Myeong-Kook;Wang, Jin-Suk;Kim, Do-Woo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.199-203
    • /
    • 2006
  • This paper presents an ASER (Accelerated Soft Error Rate) integral model. The model is based on the facts that the generated EHP/s(electron hole pairs) are diminished after some residual range of the incident alpha particle, where residual range is a function of the incident angle and the capping layer thickness over the semiconductor junction. The ASER is influenced by the flux of the alpha particles, the junction area ratio, the alpha particle incident angle when the critical charge is same as the collected charge, and the sizes of the alpha source and the chip. The model was examined with 8M static RAM samples. The measured ASER data showed good agreement with the calculated values using the model. The ASER decreased exponentially with respect to the operational voltage. As the capping layer thickness increases up to $16{\mu}m$, the ASER increases, and after that thickness, the ASER decreases. The ASER increased as the depth of BNW increased from $0{\mu}m\;to\;4{\mu}m$. and then saturated. The ASER decreased as the node capacitance increased from 2fF to 5fF.

Comparison of Target Localization Error between Conventional and Spiral CT in Stereotactic Radiosurgery

  • Kim, Jong-Sik;Ju, Sang-Kyu;Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.20-25
    • /
    • 2000
  • The accuracy of the target localization was evaluated by conventional and spiral CT in stereotactic radiosurgerv. Conventional and spiral CT images were obtained with geometrical phantom, which was designed to produce exact three-dimensional coordinates of several objects within 0.1mm error range. Geometrical phantom was attached by BRW headframe, intermediate head ring, and CT localizer. Twentv-seven slices of conventional CT image were scanned at 3 mm slice thickness. Spiral CT images were scanned at 3 mm slice thickness from the pitch value 1 to 3, and twenty-seven slices of image were obtained per each the pitch value. These CT images were transferred to a treatment planning system(X-knife, Radionics) by ethernet, Three-dimensional coordinates of these images measured from the treatment planning system were compared to known values of geometrical phantom. The mean localization error of the target localization of conventional CT was 1.4mm. In case of spiral CT, the error of the target localization was within 1.6mm from the pitch value 1 to 1.3, but was more than 30mm above the pitch value 1.5. In conclusion, as the localization error of spiral CT was increased in high pitch value compared to conventional CT, the application of spiral CT will be with caution in stereotactic radiosurgery.

  • PDF

Study of Ocular Components in Determining the Refractive State of the Eye (굴절이상을 결정하는 안광학 요소에 관한 연구)

  • Seo, Y.W.;Choe, Y.J.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.7-14
    • /
    • 1999
  • The purpose of this study is to evaluate the relationship between ocular components and refractive error for human eye. Ocular components were measured by keratometry, phakometry, and ultrasonography. Refractive error was measured by subjective refraction on 38 subjects aged from 17 to 30. The results were as follows; 1) Refractive error and axial length, vitreous chamber depth, axial length/corneal radius were highly correlated that the correlation coefficients were 0.95, 0.96, 0.95, respectively. 2) Refractive error and corneal radius, corneal power, lens thickness were correlated with the correlation coefficients for 0.60, 0.66, 0.67 respectively. 3) There were no significant correlation between refractive error and corneal thickness.

  • PDF

An Experimental Study to Reduce the Fraction of Noise Defect of Hoist Gear Boxes (호이스트 기어박스의 소음불량률 저감을 위한 실험적 연구)

  • 이희원;손병진;신용하
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1347-1354
    • /
    • 1994
  • This paper deals with the experimental research, including measurement and analysis and field survey, on the causes of occurring noise defective gear boxes in hoist production plant in order to reduce the fraction of their occurrence. In this reserch following investigations are performed : measurement and gear-boxes, examination of each machining process of production, measurement and analysis of dimensional accuracy of each part, comparative vibration test with exchanging inaccurate parts. From these investigations, it is found that the machining accuracy of pinion gear tooth thickness is the most sensitive factor of noise problem. By maintaining the tooth thickness error within 0.05 mm tolerance in the gear cutting process, the fraction of noise defective gear-boxes are greatly reduced to less than 2%, where the usual rate of it has been 20-50%.

Optimization of Process Parameters for Dry Film Thickness to Achieve Superior Water-based Coating in Automotive Industries

  • Prasad, Pranay Kant;Singh, Abhinav Kr;Singh, Sandeep;Prasad, Shailesh Kumar;Pati, Sudhanshu Shekher
    • Corrosion Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.121-129
    • /
    • 2022
  • A study on water-based epoxy coated on mild steel using the electroplating method was conducted to optimize the process parameters for dry film thickness to achieve superior paint quality at optimal cost in an automotive plant. The regression model was used to adjust various parameters such as electrode voltage, bath temperature, processing time, non-volatile matter, and surface area to optimize the dry film thickness. The average dry film thickness computed using the model was in the range of 15 - 35 ㎛. The error in the computed dry film thickness with reference to the experimentally measured dry film thickness value was - 0.5809%, which was well within the acceptable limits of all paint shop standards. Our study showed that the dry film thickness on mild steel was more sensitive to electrode voltage and bath temperature than processing time. Further, the presence of non-volatile matter was found to have the maximum impact on dry film thickness.

Study of Correlation between Macular Thickness, Retina Nerve Fiber Layer Thickness and Axial Length according to Refractive Errors in Children (아동들의 굴절이상에 따른 안축장과 황반두께, 망막신경섬유층 두께의 상관성연구)

  • Choi, Hyung-Seok;Leem, Hyun-Sung
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.421-429
    • /
    • 2018
  • Purpose : We identified correlation between macular thickness and RNFL (retina nerve fiber layer) measured by OCT and axial length in Korean children divided as three groups according to refractive errors. Methods : In total, 134 eyes of 67 Korean children who experienced no eye disease and ophthalmology surgery were involved in this study and then divided as three groups such as hyperopic, emmetropic and myopic groups. Macular thickness and RNFL thickness were measured with Cirrus HD-OCT, and axial length was done with IOL Master.Macular thickness and RNFL thickness were measured by Cirrus HD-OCT, and axial length using IOL Master. Correlation between axial length and retinal thickness in three groups according to refractive errors was investigated. Results : The type of refractive error measured by axial length was myopic, emmetropic and hyperopic groups in order, showing significant difference (p<0.05). The center thickness of macular was myopic, emmetropic and hyperopic groups in order, showing significant difference(p<0.05). The thicknesses of superior, nasal and inferior regions in peripheral macula were the thinnest in myopic group (p<0.05). It was shown that positive correlation was found between the center thickness of macula and axial length (r=0.283, p<0.05), while negative correlation was found between the peripheral thickness of RNFL and axial length. The temporal thickness of RNFL represented the thickest in myopic group, showing positive correlation with axial length(r=0.39, p<0.05). The superior, nasal and inferior thickness of RNFL represented negative correlation with axial length, showing statistically significant in the nasal thickness of RNFL(r=-0.23, p<0.05). Conclusion : Through this study, we identified correlation between macular thickness, the thickness of RNFL and axial length using OCT in Korean children, and also found the differences in three refractive error groups.

Estimation of Aerosol Optical Thickness over East Asia Using GMS-5 Visible Channel Measurements (GMS-5 위성의 가시자료를 이용한 동아시아 지역의 에어로솔 광학두께 추정)

  • Urm, Young-Dae;Sohn, Byung-Ju
    • Atmosphere
    • /
    • v.15 no.4
    • /
    • pp.203-211
    • /
    • 2005
  • One algorithm has been developed for retrieving aerosol optical thickness from GMS-5 visible channel measurements, and then the algorithm was applied for obtaining the geographical distribution of aerosol optical thickness over East Asia during April 2002. Algorithm employs a look-up table based upon radiative transfer calculations with solar geometry, aerosol optical thickness, and surface albedo as inputs. Validation was conducted by comparing retrieved aerosol optical thickness with measured values from ground-based sky radiation measurements at Anmyon Do, Korea. It was found that the correlation coefficient is 0.71 with -0.03 of bias and 0.34 of root mean square error, suggesting that the algorithm developed in this study can be used for estimating aerosol optical thickness in a quantitative sense.

The Accuracy Design of LM Guide System in Machine Tools (공작기계 직선 베어링 안내면의 정도 설계에 관한 연구)

  • 김경호;박천홍;송창규;이후상;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.692-695
    • /
    • 2000
  • This paper is concerned with Accuracy Design of LM Guide System in Machine Tools. Elastic deformation of bearing is calculated by Hertz contact theory and motion error of LM block is analyzed. A new algorithm using block stiffness is proposed fur the analysis of motion accuracy of the table. The best advantage of this algorithm is fast analysis speed because it isn't necessary iteration processes for satisfying equilibrium equation of the table. Motion errors of the table analyzed under artificial form error of rail theoretically and experimentally. Only one of two rails is bent by putting a thickness gauge into horizontal direction. This form error of rail is measured by gap sensor against the other rail. Then, motion errors of the table are predicted by proposed new algorithm theoretically and measured by laser interferometer. Measurements are carried out by changing the preload and thickness. The results show that the table motion errors are reduced from 1/2 to 1/60 times than form error of rail according to its height and width. And the effect of preloading is almost negligible.

  • PDF

Reliability on Accelerated Soft Error Rate in Static RAM of Thin Film Transistor Type (소프트 에러율에 대한 박막 트랜지스터형 정적 RAM의 신뢰성)

  • Kim Do-Woo;Wang Jin-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.6
    • /
    • pp.507-511
    • /
    • 2006
  • We investigated accelerated soft error rate (ASER) in static random access memory (SRAM) cells of thin film transistor (TFT) type. The effects on ASER by cell density, buried nwell structure, operational voltage, and polysilicon-2 layer thickness were examined. The increase in the operational voltage, and the decrease in the density of SRAM cells, respectively, resulted in the decrease of ASER values. The SRAM chips with buried nwell showed lower ASER than those with normal well structure did. The ASER decreased as the test distance from alpha source to the sample increased from $7{\mu}m\;to\;15{\mu}m$. As the polysilicon-2 thickness increased up to $1000\;{\AA}$, the ASER decreased exponentially. In conclusion, the best condition for low soft error rate, which is essential to obtain highly reliable SRAM device, is to apply the buried nwell structure scheme and to fabricate thin film transistors with the thick polysilicon-2 layer

Sensitivity and Error Propagation Factors for Three-Parameter Ellipsometry

  • Ihm, Hye-Ran;Chung, Gyu-Sung;Paik, Woon-Kie;Lee, Duck-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.11
    • /
    • pp.976-980
    • /
    • 1994
  • The sensitivity factors and the error propagation factors are defined for the three-parameter ellipsometry (TPE). The sensitivity factor is useful for understanding the nature of the TPE measurements in connection with determination of the optical properties and the thickness of a film. On the other hand, the error propagation factors provide a quantitative tool for predicting the optimum condition for TPE experiments. Their usefulness is demonstrated for the passive film formed on nickel in aqueous solution.