• Title/Summary/Keyword: Thickness Control

Search Result 2,811, Processing Time 0.03 seconds

Robust Design of Air Compressor-Driving Quadratic Linear Actuator in Fuel Cell BOP System using Taguchi Method

  • Kim, Jae-Hee;Kim, Jun-Hyung;Kim, Jin-Ho
    • Journal of Magnetics
    • /
    • v.17 no.4
    • /
    • pp.275-279
    • /
    • 2012
  • The linear actuator has the inherent drawback of air gap variation because its linear motion is usually guided by the springs, which destabilizes the dynamic performance. In order to design the linear actuator to be insensitive to air gap, this paper describes the robust design of the air compressor driving linear actuator using Taguchi method. The orthogonal arrays are constructed with selected control factors and noise factor for minimum experiment. The control factors are thickness of inner magnet, height of upper yoke, thickness of outer magnet and thickness of lower yoke while noise factor is airgap. The finite element analysis using commercial electromagnetic analysis program "MAXWELL" are performed instead of experiment. ANOVA are performed to investigate the effects of design factors. In result, the optimal robust linear actuator which is insensitive to air gap variation is designed.

Fabrication of SOl Structures For MEMS Application (초소형정밀기계용 SOl구조의 제작)

  • Chung, Gwiy-Sang;Kang, Kyung-Doo;Chung, Su-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.301-306
    • /
    • 2000
  • This paper describes on the fabrication of a SOI substrate by SDB technology and electrochemical etch-stop. The surface of the thinned SDB SOI substrate is more uniform than that of grinding or polishing by mechanical method, and this process was found to be a very accurate method for SOI thickness control. During electrochemical etch-stop, leakage current versus voltage curves were measured for analysis of the open current potential(OCP) point, the passivation potential(PP) point and anodic passivation potential. The surface roughness and the controlled thickness selectivity of the fabricated a SDB SOI substrate were evaluated by using AFM and SEM, respectively.

  • PDF

Fracture Behavior of Reinforced Concrete Beams Repaired by Latex-Modified Concrete (LMC로 보강된 철근콘크리트 보의 파괴거동)

  • 김성환;정원경;김기헌;김동호;윤경구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.475-480
    • /
    • 2003
  • Latex modification of concrete provides the material with higher flexural strength. This increase in flexural strength can attribute to the crack-arresting action of polymer in concrete, and also to the bonding they provide between the matrix and aggregates. This experimental study presents the fracture behavior of 12 flexural reinforced concrete beams repaired or strengthened by latex-modified concrete with the main experimental variables such as overlay thickness, strength thickness, and shear reinforcement. The results are as follow: All beam specimens having shear reinforcement were failed by delamination rupture at concrete interface at about 80% of ultimate loading after flexural cracking. All specimens overlayed and strengthened by latex-modified concrete (LMC) showed higher ultimate flexural strength than OPC control specimen, but lower than LMC control specimen. This increase in flexural strength could attribute to the high bonding they provide between the matrix and aggregates. All specimens except two shear unreinforced showed quite similar and consistent displacement behavior. The effect of overlay and strength thickness on the load-displacement relationship were a small at this study.

  • PDF

Characteristics Control of a Thickness Mode Piezoelectric Vibrator Using a Negative Impedance Converter Circuit (부임피던스 변환회로를 이용한 두께 모드 압전 진동자의 특성제어)

  • 황성필;김무준;하강열
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.7
    • /
    • pp.600-605
    • /
    • 2002
  • In this paper, a Negative Impedance Converter (NIC) circuit was employed for the electro-mechanical characteristic control of a thickness mode piezoelectric vibrator. Two circular plane piezoelectric vibrators were bonded together and the NIC circuit was connected to one of the vibrators. The theoretical and experimental analysis of the characteristics shown that the quality factor and the electro-acoustic efficiency of the vibrator with the NIC circuit could be improved by 20 times and 2.5 times, respectively.

The Fabrication of a SDB SOI Substrate by Electrochemical Etch-stop (전기화학적 식각정지에 의한 SDB SOI기판의 제작)

  • 정귀상;강경두
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.5
    • /
    • pp.431-436
    • /
    • 2000
  • This paper describes on the fabrication of a SOI substrate by SDB technology and electrochemical etch-stop. The surface of the thinned SDB SOI substrate is more uniform than that of grinding or polishing by mechanical method and this process was found to be a very accurate method for SOI thickness control. During electrochemical etch-stop leakage current versus voltage curves were measured for analysis of the open current potential(OCP) point the passivation potential(PP) point and anodic passivation potential. The surface roughness and the controlled thickness selectivity of the fabricated a SDB SOI substrate were evaluated by using AFM and SEM respectively.

  • PDF

Therapeutic Effects of Acupuncture and Herbal External Preparation on Healing of Deep Partial Thickness Burn Wound in Rats (심재성 2도 화상이 유발된 흰쥐의 조직 회복에 대한 침 및 한약외용제의 효과)

  • Jo, Hee-Guen;Park, Ae-Ryon;Choi, Jin-Bong
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.24 no.3
    • /
    • pp.87-98
    • /
    • 2014
  • Objectives The present study aimed to investigate the effects of acupuncture and herbal external preparation on wound healing procedure in a deep partial thickness burn model in rats. Methods A total of 40 male Sprague-Dawley rats were allocated into four groups with an equal number in each group: acupuncture treatment group, herbal external perparation group, Silver sulfadiazine dressing group and control group. We describe the effect of acupuncture and herbal external preparation on morphologic and histologic changes, epithelial growth factor (EGF), hematological value of the deep partial thickness burn wound in rats. Results At 21th day after wounding the wound size in acupuncture treat group and herbal external preparation group were decreased more significantly compared to control group. In addition, epidermal regeneration on acupuncture treatment was than other treatment and control group in histological finding. Hematological findings revealed that acupuncture treatment group and herbal external prepartion group was more effective than control group in reducing inflammation response induced by burn. In acupuncture treated group, neutrophil and leukocyte level were significantly decreased compared to other treatment group. Also, this study showed that EGF was obviously expressed in nascent tissue when wounds were treated with the acupuncture and herbal external preparation after injury. In particular, acupuncture treatment group had a significant increase of EGF expression in burn wound healing area when compared with the other treatment groups. Conclusions These findings suggest that acupuncture and herbal external prepration may improve burn wound healing through decreasing inflammatory reaction, increasing tissue regeneration and expression of EGF. Moreover, acupuncture treatment could be more effective in comparison with Silver sulfadiazine dressing.

The effect of periodontal therapy on the gingival thickness in patients with drug-induced gingival enlargement (치주치료가 약물성 치은비대 환자의 치은두께에 미치는 효과에 관한 연구)

  • Kim, Won-Kyung;Baek, Jin;Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.1109-1116
    • /
    • 2005
  • The purpose of this study was to observe the effects of periodontal therapy, including nonsurgical periodontal therapy with azithromycin, surgical therapy, and maintenace therapy on the drug-induced gingival enlargement, by means of measuring gingival thickness. The test group of 18 patients with drug-induced gingival enlargement received scaling, root planing with azithromycin for 5 days, with or without surgical periodontal treatment. The control group of 18 patients who had not taken any medication, received scaling and root planing, with or without surgical periodontal treatment. Both groups received supportive periodontal therapy every 3 months for 2 years. The mean period of total treatment is 32 months in the test group and 31 months in the control group. The thickness of the buccal gingiva was measured using an ultrasonic device of $SDM^{(R)}$(Krupp Corp., Essen, Germany). The results revealed that the test $group(1.21{\pm}0.51mm)$ showed statistically thicker buccal gingiva than the control $group(1.01{\pm}0.3mm)$. In the test group, the buccal gingiva was thickest on 2nd molars and was thinnest on canines of both dental arches. In the control group, the buccal gingiva was thickest on central incisors in the maxilla and 2nd molars in the mandible, while the thinnest areas were on canines in the maxilla and 1st premolars in the mandible. It would be concluded that the periodontal treatment with azithromycin aids in decreasing the degree of the gingival enlargement but cannot prevent the recurrence completely.

The effects of Far-infrared on Type II collagen induced mouse and the relative cytokine computerize programming (Emphasis on TNF-a and IL-1b) (원적외선이 관절염 흰쥐 모델에 미치는 영향과 관련 싸이토카인 예측 프로그래밍)

  • Kim Jae Yoon;Kim Jin-Sang;Bae Sung Soo;Park Rae Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.1
    • /
    • pp.38-60
    • /
    • 2003
  • The purpose of this study was to observe the effects of Far-infrared on mice rheumatoid arthritis induced by type II collagen. The author peformed several experimental tests which were the hematoxylin-eosin tissue stain, the hind paw thickness, and ELSIA of cytokines(TNF-$\alpha$, IL-1$\beta$). On day 14 and 21, FIR-Tx. group decreased in synovial membrane thickness more than control II group FIR-Tx group decreased in hind paw thickness more than control II group. In the ELISA test of TNF-$\alpha$ concentration, control II group significantly increased in the concentration more than normal and FIR-Tx. group on day 7, 14, and 21. In the ELISA test of IL-$\beta$ concentration, FIR-Tx. group decreased in the concentration more than control II group on day 14 and 21. With J's Linear Function Data Process Program, researchers can get the estimated the concentration or the hind paw thickness from this experiment. The estimated results would be a good guide to therapists and researchers, planning Far-infrared application on the rheumatoid arthritis. These results indicated that far-infrared irradiating appeared to reduce the concentration of TNF-$\alpha$ and IL-1$\beta$ at mouse model of autoimmune arthritis. It would be considered that Far-infrared has an effect on relieving rheumatoid arthritis.

  • PDF

Altered Motor Control in Patients With Neck Pain and Prospective Research Work (경부통증 환자의 변형된 운동조절 특성 분석과 향후 활용 방안)

  • Lee, Min-young;Yoon, Bum-chul
    • Physical Therapy Korea
    • /
    • v.23 no.2
    • /
    • pp.20-34
    • /
    • 2016
  • Background: It is necessary to find and develop the effective way of intervention for patients with neck pain, since the neck pain is becoming increasingly common throughout the world. To identify the altered motor control in patient with neck pain would be informative to find and develop the effective way of intervention. Objects: The aim of this study was to review literature regarding the altered motor control in patients with neck pain, measured by using surface electromyography (sEMG), ultrasonography, and functional magnetic resonance imaging (fMRI), and to suggest prospective research work on neck pain. Methods: Case-control (neck pain/healthy) studies published between 2004 and 2015 that investigated neck muscle activation, thickness, cross-sectional area, and fat infiltrate were searched in Scopus, PubMed, and ScienceDirect. Twenty-eight articles were included in this study. Results: sEMG, ultrasonography, and fMRI were used complementarily to investigate the altered superficial and deep neck muscle activation, thickness, cross-sectional area, and fat infiltrate in patients with neck pain. They showed the following altered motor control when compared retrospectively with healthy subjects or during specific functional tasks: (1) increased superficial muscle activation, (2) lesser deep muscle thickness, (3) smaller cross-sectional area of the deep muscle, and (4) greater fat infiltrate in deep muscles. In particular, among the women, the office workers showed higher muscle activation of superficial neck muscles during functional tasks, although they did not have neck pain, than those who were not office workers. Conclusion: Studies revealed that patients with neck pain showed an altered motor control when compared with healthy subjects by using various assessment modalities. Understanding this phenomenon would help researchers design an effective intervention for alleviating neck pain or to evaluate the effectiveness of the intervention. In addition, we recommend that female office workers take measures to care for their necks before developing neck pain.

A Study on Rolling Mill Dynamics Model and Automatic Gauge Control System

  • Kim, Tae-Young;Kwon, Dae-Hyun;Choi, Won-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.120-125
    • /
    • 2004
  • In the rolling of steel or non-steel metal the most important quality aspect are thickness and flatness. In thickness, there are two important factors. One of them is getting close with accurate goal, nominal gauge, the other is minimize gauge bandwidth, the variation in gauge. In this thesis, we proposed the fuzzy model AGC to minimize gauge variation along the length, developed the rolling mill dynamic model using the math mode of the rolling mill process and the rolling model related with the variety character of the rolling material. We compared the gauge control efficiency of fuzzy model AGC and PI mass flow AGC. We have got a simulation result, that the exit gauge variation of PI mass flow AGC was 2 micron and fuzzy model AGC was 1.2 micron at 1200mpm of rolling speed when each controller was rolling 5 micron of material that is the entry gauge variation.

  • PDF