• Title/Summary/Keyword: Thickness, Ultrasonography

Search Result 265, Processing Time 0.028 seconds

Ultrasonographic evaluation of skin thickness in small breed dogs with hyperadrenocorticism

  • Heo, Seonghun;Hwang, Taesung;Lee, Hee Chun
    • Journal of Veterinary Science
    • /
    • v.19 no.6
    • /
    • pp.840-845
    • /
    • 2018
  • The purpose of this study was to propose a standard for differentiation between normal dogs and patients with hyperadrenocorticism (HAC) by measuring skin thickness via ultrasonography in small breed dogs. Significant changes in skin thickness of patients treated with prednisolone (PDS) or patients with HAC treated with trilostane were evaluated. Skin thickness was retrospectively measured on three abdominal digital images obtained from small breed dogs weighing < 15 kg that underwent abdominal ultrasonography. Mean skin thickness of normal dogs was $1.03{\pm}0.25mm$ (mean ${\pm}$ SD). Both the HAC and PDS groups showed significantly thinner skin than that in the normal group. Seven of the 10 HAC patients treated with trilostane had increased skin thickness. The area under the curve value of 0.807 was based on the receiver operating characteristics (ROC) curve for differentiating normal dogs from HAC patients. Sensitivity was 76% and specificity was 73% when skin thickness was less than the 0.83 mm cutoff value. In conclusion, measurement of skin thickness in small breed dogs by using ultrasonography is likely to provide clinical information useful in differentiating HAC patients from normal dogs. However, exposure to PDS, trilostane, and other conditions may have a significant effect on skin thickness.

Comparison of Ultrasonography on Both Sides of the Upper Extremity Muscle of Hemiplegic Patient (편마비환자 양측 상지근에 대한 초음파 영상 비교)

  • Seo, Sam-Ki;Lee, Jeong-Woo;Yoon, Se-Won
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.5 no.1
    • /
    • pp.1-10
    • /
    • 2007
  • This study aims to comparison of ultrasonography on both sides of the upper arm of hemiplegic patient. The biceps brachii and deltoid muscle of ten subjects(4 men, 6 women) with stroke were scanned with ultrasonography at the muscle belly at rest at elbow angles of 90 deg. The echogenicity(densit, white area index; WAI) and muscle thickness of ultrasonography was examined using real-time B-mode ultrasonography with 7.5 MHz linear-array prob. In the biceps brachii muscle, MHz there were significant differences of thickness, density, and WAI between affected side and non-affected side. In the deltoid muscle, there were significant differences of thickness, density, and WAI between affected side and non-affected side. Both of the muscles, thickness of the affected side was thin than non-affected side and echogenicity(density, WAI) of the affected side was higher than non-affected side. This study showed that change of skeletal muscle architecture properties occurred in the upper arm of the affected side muscle of hemiplegic patient.

  • PDF

The relationship between masseter muscle thickness measured by ultrasonography and facial profile in young Korean adults

  • Park, Kyeong-Mee;Choi, Eunhye;Kwak, Eun-Jung;Kim, Seoyul;Park, Wonse;Jeong, Jin-Sun;Kim, Kee-Deog
    • Imaging Science in Dentistry
    • /
    • v.48 no.3
    • /
    • pp.213-221
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the relationship between masseter muscle thickness, facial morphology, and mandibular morphology in Korean adults using ultrasonography. Materials and Methods: Ultrasonography was used to measure the masseter muscle thickness bilaterally of 40 adults(20 males, 20 females) and was performed in the relaxed and contracted states. Facial photos and panoramic radiography were used for morphological analyses and evaluated for correlations with masseter muscle thickness. We also evaluated the correlations of age, body weight, stature, and body constitution with masseter muscle thickness. Results: In the relaxing, the masseter was $9.8{\pm}1.3mm$ in females and $11.3{\pm}1.2mm$ in males. In the contracted state, it was $12.4{\pm}1.4mm$ in females and $14.7{\pm}1.4mm$ in males. Facial photography showed that bizygomatic facial width over facial height was correlated with masseter muscle thickness in both sexes in the relaxed state, and was statistically significantly correlated with masseter muscle thickness in males in the contracted state. In panoramic radiography, correlations were found between anterior angle length and posterior angle length and masseter muscle thickness in females, and between body length and posterior angle length, between anterior angle length and body length, between ramal length and body length, and between body length and condyle length in males. Conclusion: Masseter muscle thickness was associated with facial and mandibular morphology in both sexes, and with age in males. Ultrasonography can be used effectively to measure masseter muscle thickness.

The Analysis of Ultrasonography on Gastrocnemius Medialis of Patient with Stroke (뇌졸중환자 내측 비복근의 초음파 영상 분석)

  • Seo, Sam-Ki
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.2
    • /
    • pp.11-19
    • /
    • 2007
  • Purpose: The purpose of this study were to analyze ultrasonography on both sides of gastrocnemius medialis of stroke patient. Methods: In fourteen subjects with stroke, the gastrocnemius medialis(GM) muscle were scanned with ultrasonography at the muscle belly at rest at ankle angles of 0 degree (neutral position) and it were measured with ultrasonography on both sides of the leg. Muscle architecture (thickness, pennation angle, fascicle length, density, white area index) was examined using real-time B-mode ultrasonography with 7.5MHz linear-array prob. Results: Thickness of non-paratic side was significantly thicker than paratic side. Pennation angle of non-paratic side was significantly larger than paratic side. Fascicle length of non-para tic side was significantly smaller than paratic side. Density of non-paratic side was significantly smaller than paratic side. White area index of non-paranc side was significantly smaller than paratic side. Conclusion: This study showed that stroke have influenced on mechanical properties and quality properties of skeletal muscle architecture.

  • PDF

Diagnostic Correlation between Ultrasonography and CT Arthrography in Rotator Cuff Disease (회전근 개 질환에서 초음파 검사와 관절 조영 컴퓨터 단층 촬영의 진단적 가치 비교)

  • Park, Tae Soo;Yoon, Jong Pil;Kim, Hyung Sup;Jeong, Won-Ju
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.2
    • /
    • pp.53-59
    • /
    • 2013
  • Purpose: The aim of this study wasto evaluate the comparison of CT arthrography and ultrasonography, confirmed by the arthroscopic finding in patients with rotator cuff disease. Materials and Methods: We evaluated fifty seven patients with rotator cuff disease underwent CTA and arthroscopy, and twenty eight patients had taken ultrasonographyadditionally. The diagnostic value and prediction for tear size between CTA and ultrasonography were evaluated, as compared to arthroscopic findings. Results: CTA showed a sensitivity of 86.2% and a specificity of 100% in full thickness tear ofsupraspinatus, a sensitivity of 58.3% and a specificity of 87.8% in partial-thickness tear. CTA demonstrated good diagnostic value for full thickness tear, but there was relatively lower value for partial-thickness tear. Ultrasonography showed a sensitivity of 84.6% and a specificity of 86.7% for diagnosing in full thickness tear, a sensitivity of 84.6% and a specificity of 73.3% in partial-thickness tear. Ultrasonography provided good diagnostic value, but, there is lesser accurate result for prediction of tear size. Conclusion: CTA showedgood diagnostic tool of detection full-thickness tear of rotator cuff disease and predicting of tear size. Comparing with ultrasonography, CTA was inferior for detection of partial-thickness tear, but, provided better estimation for tear size.

  • PDF

Outcome of Nonoperative Treatment for Proximal Plantar Fasciitis: Comparative Analysis According to Plantar Fascia Thickness (근위 족저 근막염의 비수술적 치료 결과 : 족저 근막 두께에 따른 비교 분석)

  • Yoon, Kwang-Sup;Jung, Hong-Geun;Bae, Eui-Jung;Kim, Tae-Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.2
    • /
    • pp.122-127
    • /
    • 2008
  • Purpose: To evaluate the clinical outcome of proximal plantar fasciitis after nonoperative treatment, and also to find the correlation of the heel pain with the plantar fascia thickness measured by ultrasonography. Materials and Methods: The study is based on 41 patients, 46 feet of the proximal plantar fasciitis that were treated conservatively with at least 12 months follow-up. All were treated with heel pad, Achilles and plantar fascia stretching and pain medications for at least 3 months. Heel ultrasonography was performed at the beginning of the treatment to measure the plantar fascia (PF) thickness and the echogenicity. PF thickness over 4 mm and less were grouped in to group A and B respectively to compare the clinical outcome. Results: Average thickness of the PF at the calcaneal attach was 5.2 mm. Symptom duration before the treatment was average 13.2 month; group A being 14.6 months and group B being 9.0 months with no significant difference (p=0.09). As functional evaluation, Roles-Maudsley score improved from 3.4 initially to 2.3 at final follow-up, while morning heel pain also improved from average VAS pain score of 7.2 to 4.0. However Maudsley and VAS score both didn't show statistical difference between the 2 groups (p>0.05). Conclusion: Plantar fasciitis improved substantially with the nonoperative treatments. However, the 2 groups, divided according to 4 mm thickness by ultrasonography, didn't show significant difference in either symptom duration or in the clinical outcomes.

  • PDF

Maximal Voluntary Contraction and Muscle Thickness Relationship in Skeletal Muscle (골격근에서 최대 수의적 등척성 수축력과 근 두께와의 관계)

  • Jeong, Jin-Gyu;Kim, Yang-Ho;Kim, Tae-Youl
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.2 no.2
    • /
    • pp.25-37
    • /
    • 2004
  • To provide reflection diagnostical basic-data by ultrasonography intended for 38 male/female students used by ultrasound imaging system and dynamometer, compared the MVIC and muscle thickness take an accurate measurement of elbow flexor and knee extensor of thickness and MVIC, in confirmity with distinction of sex and then analysised of correlation in muscle thickness-MVIC, MVIC-weight, weight-muscle thickness, it shows statiscally significant difference MVIC and muscle thickness according to sex. Also there is a high interrelation between two. As well as it shows that there is a different between sex in the MVIC of same thickness and MVIC of same weight. This difference will be related with preportions of muscle fiber type in view of the results by preceded research, it needs to be prerequisite analysis of difference in sex with a great variety of ways hereafter.

  • PDF

Ultrasonography to the Diagnosis of Dogs with cataracts and retinal detachment (개의 백내장 및 망막박리에서의 초음파 진단)

  • 김종택
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.235-237
    • /
    • 1997
  • Cataract and Retinal detachment eyes dogs were examined by ultrasonography. Ultrasonography of the immature and mature cataractous eyes showed echographic changes, and cataractous lens increased in thickness. The diagnosis of retinal detachment was made an echodense waving motion structure in the posterior segment was imaged. This investigation will provide basic information for the study of pathologic conditions affecting the eyes of dog using ultrasound unit commonly available to the veterinarian.

  • PDF

Effects of Diamond Taping Applied Around the Lateral Elbow on Common Extensor Tendon Thickness, Grip Strength and Wrist Extension Force in Healthy Subjects (팔꿉관절 가쪽 부위에 적용한 다이아몬드 테이핑이 정상인의 공동폄근 힘줄의 두께와 악력, 손목 폄력에 미치는 영향)

  • Park, So-hyun;Kim, Suhn-yeop
    • Physical Therapy Korea
    • /
    • v.27 no.3
    • /
    • pp.163-170
    • /
    • 2020
  • Background: The characteristics of lateral epicondylitis (LE) are muscle strength weakness and increased common extensor tendon (CET) thickness. Ultrasonography has recently been used to evaluate tendinopathy. Diamond taping (DT) is commonly used to manage patients with LE. However, no previous studies have investigated the effects of DT on CET thickness. Objects: The aim of this study was to investigate the effects of DT applied around the lateral elbow on CET thickness, grip strength, and wrist extension force in healthy subjects. Methods: The subjects were 26 adults (13 male) in their twenties. First, the CET thickness was measured at rest. The CET thickness was measured by using ultrasonography at two points. The subjects were then instructed to perform maximal grip activities or maximal wrist extension activities before and after DT around the lateral elbow. The DT technique was applied using non-elastic tape. While the subjects performed maximal grip activities, the investigator measured the maximum grip strength (MGS) and CET thickness. Likewise, while the subjects performed maximal wrist extension activities, the investigator measured the maximum wrist extension force (MWEF) and CET thickness. Results: The MGS showed a statistically significant improvement after DT taping application in men (p < 0.05). The MWEF showed a statistically significant improvement after DT application in male (p < 0.01) and female (p < 0.05). When performing the activities, the CET thickness increased compared to that at rest. However, CET thickness didn't show a statistically significant improvement before and after DT. Conclusion: This study shows that DT applied around the lateral elbow is effective in improving MGS and MWEF. However, it does not affect CET thickness.

The Effect of Change in Transversus Abdominis Thickness Using Ultrasound Image during a Hip Adductor Contraction (고관절 내전근 수축이 복횡근의 두께변화에 미치는 영향)

  • Moon, Hyun-Ju;Goo, Bong-Oh
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.3
    • /
    • pp.287-292
    • /
    • 2011
  • Purpose :The present study invesigated the effect of changes in transversus abdominis thickness using ultrasonography during a hip adductor contraction. Methods : This study was carred out in a volunteer sample of adults (N=30) without a history of low back pain or injury. In standing position, muscle thickness measurements of transversus abdominis(TrA) were measured using ultrasonography at rest and during a hip adducor contraction. Results : TrA thickness were influenced a hip adductor during a voluntary contraction in people without LBP. TrA showed significantly greater thickness changes on a hip adductor contraction.(p=0.000) Conclusion : The results from this study showed that the hip adductor contraction improves the ability to increase change in TrA thickness. These results can be a good evidence to prevent low back pain due to hip adductor weakness or genu varum deformity of knee osteoarthritis.