• Title/Summary/Keyword: Thickener

Search Result 99, Processing Time 0.026 seconds

The Relationship between Rheological Properties and Spraying Behaviour of Polymer Dispersion

  • Dijkstra Dirk J.;Kiyomoto Yasuhiro;Abe Katsuya
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.133-134
    • /
    • 2006
  • In contrast to paints, the surface appearance of adhesive materials is of minor importance, because the adhesive is invisible between the two substrates. Therefore, the rheological properties needed to apply an adhesive dispersion by spray coating can be quite different. The influence of three different kinds of thickeners on the spraying behaviour of polyurethane adhesive dispersions was investigated. The associative thickener showed only minor changes, whereas the higher molecular weight soluble thickeners dramatically changed the spraying angle and the amount of overspray. Determination of the elongational viscosity by means of the CaBER rheometer proved to be of limited use for thickened dispersions.

  • PDF

Printing Properties of Novel Regenerated Cellulosic Fibers

  • Kim, Ik-Soo;Koh, Joon-Seok;Han, Nam-Keun;Kim, Jae-Pil
    • Fibers and Polymers
    • /
    • v.5 no.3
    • /
    • pp.219-224
    • /
    • 2004
  • The reactive printing properties of regular viscose rayon and a new regenerated cellulosic fiber (en Vix^{\textregistered}$) which was prepared from cellulose acetate fiber was investigated in a comparative manner. From the results, it was found that en Vix exhibited better printing properties than regular viscose rayon. It showed stable final color yields, irrespective of the amount of thickener, hence reproducibility of printing of en Vix is expected to be excellent. In addition, urea requirements were less for the printings on en Vix than for the corresponding printing on viscose rayon. Therefore, en Vix is also expected to reduce the amount of the urea which causes environmental problems in dyehouse effluent.

Mechanical Properties of PMMA Mortars without Crosslinking Agent (가교제 무첨가 PMMA 모르타르의 역학적 특성)

  • 최낙운;김완영;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.425-428
    • /
    • 2003
  • This study deals with the mechanical properties of polymethyl methacrylate(PMMA) mortars without crosslinking agent. Waste expanded polystyrene(EPS) is used as a multifunctional admixture such as a thickener, a extender, a shrinkage reducing agent, a assistant to polymerization. PMMA mortars are prepared with various EPS contents of binder and subjected to a dry and a dry/heat combined curing, and tested for working life, flexural and compressive strengths. From the test results, the working life of PMMA mortars without crosslinking agent is shortened with raising EPS content of binder. The flexural and compressive strengths of the PMMA Mortars are decreased somewhat with increase in the EPS content. PMMA mortars with good mechanical properties could be manufactured without any crosslinking agent and their properties would be controled by adjusting EPS content of binder.

  • PDF

Anaerobic Digestion of Thickened Septage at Municipal Wastewater Treatment Plant (하수(下水) 처리장(處理場)에서 정수조폐액(淨水槽廢液)의 혐기성소화(嫌氣性消化) 처리(處理)에 관한 연구(硏究))

  • Choi, Eui So;Kim, Tai Hyung;Lee, Ho Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.7 no.1
    • /
    • pp.13-19
    • /
    • 1993
  • Anaerobic Digestion of thickened septage was investigated in this study. Thickening could reduce the volume of septage to be treated to about 40% with 12hr HRT. The VS and BOD removal efficiencies were respectively 28 to 45%, and 75% when digested the thickened septage with 30 day HRT Or $1.4kgVS/m^3/d$. The BOD removal efficiency could be increased to about 90% with subsequent settling tank with about 6 hours HRT. The gas production rate was 0.22 to $0.35m^3gas/kgVSadd$($0.75m^3gas/kgVSrm$), or $1.32m^3gas/kgBOD_{rm}$. In addition, the supernatant of thickener could be returned to the aeration tank treating domestic sewage. In this case, a BOD loading rate of 0.5 to $0.7kgBOD/m^3/d$ or 0.5kgBOD/kgMLVSS/d was proposed for 80% BOD reduction.

  • PDF

Preparation of Heat-resistance Waterborne Coating Containing Synthetic Hectorite Clay (합성헥토라이트 점토를 함유한 내열성 수성코팅제의 제조)

  • 이석기;이병교
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.2
    • /
    • pp.122-127
    • /
    • 2001
  • 수열법으로 합성한 헥토라이트 점토(SHC), 아크릴 라텍스 및 코팅첨가제들을 배합하여 성분이 다른 수성코팅제(WBC-0, WBC-1, WBC-2) 3종류를 제조하였다. 제조한 수성코팅제(WBC)의 pH, 용액점도 및 고형분을 조사하였고, 전단력에 따른 유동성을 레오메타로 측정하였다. 또한 WBC로부터 주조된 필름의 열안정성과 투명성을 각각 TGA와 UV-VIS 분광광도계로 조사하였다. SHC가 8 phr 포함된 WBC-2는 전단력에 따라 졸과 겔의 상전이 현상, 즉 요변성을 나타내었으며 이로 인해 저장안정성이 우수하였다. 주조한 WBC-1과 WBC-2 필름의 초기분해온도와 투명성은 시판 WBC(OP-55W)의 필름보다 각각 99.6~110.2$^{\circ}C$와 20.9~21.7%의 범위로 증가하였다. 결과적으로, SHC가 함유된 WBC는 수팽윤성 점토에 의해 내열성과 용액점도의 증대효과가 나타났다.

  • PDF

Exmination of Rheological Properties on Cement Paste of High-Blaine Blast Furnace Slag Fineness (고미분말 고로슬래그의 치환율 변화에 따른 시멘트 페이스트의 레올로지 성질 검토)

  • Lim, Ji-Hee;Lee, Gun-Cheol;Yoon, Seung-Joe
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.186-187
    • /
    • 2013
  • Recently, high fluidity concrete is becoming more prevalent. High fluidity concrete uses admixture or thickener in order to prevent separation of materials due to increased fluidity, and, especially, BS is becoming more use for reduced heat of hydration and improved long-term strength. This study examined the effect of BS on fluidity of cement paste from a rheological viewpoint. As for BS types, materials equivalent to 1 types of KS F 2563 and the cement mass was substituted by 20, 40, 60, 80%.

  • PDF

Experimental study of file filling meterial with A thickener (증점제를 첨가한 매입말뚝 주면고정액의 실험적 연구)

  • Ko, Hye-Bin;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.21-22
    • /
    • 2020
  • In this study, the pile filling materials of the pile in drilled piling was studied. cement milk is mostly used as the filling materials of bored pile. The use of filling material based on cement milk is inefficient at field construction because it needs a lot of the charging mass. thickening agent was added to the cement milk to perform settlement estimation experiment on a circular cylinder, and as a result of examining the compressive strength of the day, it was found that the settlement estimation was significantly reduced. However, the strength was relatively low, it was confirmed that there was no problem with the regulation because the main surface fixative required relatively low strength.

  • PDF

A Study on the Factors that Influence the Sun Protection Factor(SPF) and Protection Factor of UV-A(PA) in Sunscreen (자외선 차단제품에서 자외선차단지수(SPF)와 자외선A차단등급(PA)에 영향을 주는 인자에 관한 연구)

  • Yeon, Jae-Young;Seo, Jeong-Min;Bae, Jun-Tae;Lee, Cheong-Hee;Lee, Sang-Gil;Pyo, Hyeong-Bae;Hong, Jin-Tae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.422-439
    • /
    • 2014
  • In this study, we measured the effects of UV protection efficiency of the polarity of oil, the type of emulsion, the viscosity of product, the type of thickener and light stabilizer in sunscreen. As a result, even higher polarity of the oil, UV protection efficiency is measured high (Butyloctyl salicylate: SPF 44.10, PA 7.93). In case of low, it was measured low conversely (Dimethicone: SPF 16.40, PA 5.57). In case of emulsion types, UV protection efficiency of W/O emulsion which organic sunscreen agent is based in the outer phase is measured higher than O/W emulsion. According to increasing of viscosity, UV protection efficiency tends to increase proportionally. However, the size of emulsion particles and the kinds of thickener has no effect to UV protection efficiency. Also light stabilizer was found to be an important factor affecting the UV protection efficiency. As a result, it is able to improve UV protection efficiency and it has potential which improve the economical effect of the sunscreen without increasing sunscreen agents.

Chemical Effects to Cement Concrete by Grease Oxidation (그리이스의 산화가 시멘트 콘크리트에 미치는 화학적 영향)

  • 정근우;조원오;김영운;임수진;이은아;김성욱
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.06a
    • /
    • pp.99-105
    • /
    • 2000
  • Greases composed of base oil and thickener are widely used in the purpose of lubrication and anti-corrosion of machinery. However, greases are sometimes oxidized and decomposed by heat of friction, and produced organic acid. And the greases leaked out ordinary spot make the concrete structures weaken. In this study, the chemical effects of the greases with the concrete structures were investigated through oxidation reaction under pressure and oxygen, and evaluated by the analysis of TAN, Ca content, FT-IR and XRD of grease and cement powder after the oxidation reaction. As the results, TAN value decreased with the increase of the content of cement because of neutralization of organic acid produced by the oxidation of grease with calcium contained in the cement. The content of calcium linearly increased with the increase of cement due to calcium salt by neutralization of acid. Also, according to XRD results of the cement powder oxidized at 99 $^{\circ}C$, the diffraction peak due to calcium hydroxide decreased in comparison with that at room temperature because of the reaction of calcium and organic acid.

  • PDF

Evaluation of Design Parameter on Residuals Treatment Facilities in Membrane Water Treatment Plants (막여과 정수장에서의 배출수처리시설 설계인자 평가)

  • Moon, Yong-Taik;Seo, In-Seok;Kim, Hong-Suck;Park, No-Suk;Ahn, Hyo-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.138-146
    • /
    • 2006
  • The characteristics of backwash and concentrate discharges depend upon the quality of the water being treated and the net recovery of the membrane system. This paper is to indicate a design methods on the capacities of residuals treatment facilities in membrane processes for drinking water. We operated a demonstration membrane plant with a recovery rate of 90% for designing G-water treatment plant. We investigated on design parameter (optimum coagulant dosage and surface loading rate etc.) to design efficiently the residuals treatment facilities. The settling test was conducted with 1m columns dosing PACl to kaolin and membrane residuals under the experimental condition that discharge permit was under a 60mg/L. When the quantity of membrane residuals was $1,575m^3/day$, the estimated results for 1st thickener demonstrated the surface loading rate of 14.4m/day, detention time of 5.83hr, available depth of 3.5m.