• 제목/요약/키워드: Thick-wall pipes

검색결과 13건 처리시간 0.016초

펄스와전류를 이용한 보온재 비해체식 배관감육 평가기술 (Nondestructive evaluation of wall thinning covered with insulation using pulsed eddy current)

  • 박덕근;;이덕현
    • 한국압력기기공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.90-95
    • /
    • 2014
  • Local wall thinning is a point of concern in almost all steel structures such as pipe lines covered with a thermal insulator made up of materials with low thermal conductivity(fiberglass or mineral wool); hence, Non Destructive Technique(NDT) methods that are capable of detecting the wall thinning and defects without removing the insulation are necessary. In this study we developed a Pulsed Eddy Current(PEC) system to detect the wall thinning of Ferro magnetic steel pipes covered with fiber glass thermal insulator and shielded with Aluminum plate. The developed system is capable of detecting the wall thickness change through an insulation of thickness 10cm and 0.4mm aluminum shielding. In order to confirm the thickness change due to wall thinning, two different sensors, a hall sensor and coil sensor were used as a detecting element. In both cases, the results show a very good change corresponding to the thickness change of the test specimen. During these experiments a carbon steel tube of diameter 210mm and a length of 620mm, which is covered with insulator of 95mm thickness was used. To simulate the wall thinning, the thickness of the tube is changed for a specified length such as 2.5mm, 5mm and 8 mm from the inner surface of the tube. A 0.4mm thick Aluminum plate was covered on the Test specimen to simulate the shielding of the insulated pipelines. For both hall sensor and coil detection methods Fast Fourier transform(FFT) was calculated using window approach and the results for the test specimen without Aluminum shielding were summarized which shows a clear identification of thickness change in the test specimen by comparing the magnitude spectra. The PEC system can detect the wall thinning under the 95 mm thickness insulation and 0.4 mm Al shielding, and the output signal showed linear relation with tube wall thickness.

Analytical calculation method for the axial equivalent elastic modulus of laminated FRP pipes based on three-dimensional stress state

  • Chen, Li;Pan, Darong;Zhao, Qilin;Chen, Li;Chen, Liang;Xu, Wei
    • Structural Engineering and Mechanics
    • /
    • 제77권1호
    • /
    • pp.137-149
    • /
    • 2021
  • In engineering design, the axial equivalent elastic modulus of laminated FRP pipe was mostly calculated by the average elastic modulus method or the classical laminated plate theory method, which are based on relatively simplified assumptions, and may be not accurate enough sometimes. A new analytical calculation method for the axial equivalent elastic modulus of laminated FRP pipe was established based on three-dimensional stress state. By comparing the results calculated by this method with those by the above two traditional analytical methods and the finite element method, it is found that this method for the axial equivalent elastic modulus fits well not only for thin-walled pipes with orthotropic layers, but also for thick-walled pipes with arbitrary layers. Besides, the influence of the layer stacking on the axial equivalent elastic modulus was studied with this method. It is found that a proper content of circumferential layer is beneficial for improving the axial equivalent elastic modulus of the laminated FRP pipe with oblique layers, and then can reduce its material quantity under the premise that its axial stiffness remains unchanged. Finally, the meso-mechanical mechanism of this effect was analyzed. The improving effect of circumferential layer on the axial equivalent elastic modulus of the laminated FRP pipe with oblique layers is mainly because that, the circumferential fibers can restrain the rigid body rotations of the oblique fibers, which tend to cause the significant deformations of the pipe wall units and the relatively low axial equivalent elastic modulus of the pipe.

내(耐)Sour 라인파이프 강재의 개발동향 및 용접부 Sour특성 (Development Trend of Sour Resistant Linepipe Steel and its Sour Characteristics in Welded Joints)

  • 김영훈;송우현;고성웅
    • Journal of Welding and Joining
    • /
    • 제32권5호
    • /
    • pp.21-25
    • /
    • 2014
  • Oil and gas fields were left unexploited which deemed too deep and sour. New developing markets are emerging in this part and pipe manufacturers need demanding requirements in the combination of sour service requirements with heavier wall thickness required to cope with increasing water depths. Whilst, the strength and fracture toughness needed to meet the strict requirements In order to deliver the optimum sour properties in the final pipe, attention needs to be paid to each stage throughout the process from steel making. The main key during steel making is strengthening, securing mechanical properties and suppression of center segregation by adding proper chemical elements and controlling water cooling and plate rolling. Additionally in welding, it is required to prevent HAZ softening by high heat input during welding of heavy thick pipes and hydrogen assisted cracking in high strength steels with hard phases. In this paper, we introduce markets of sour resistant linepipe steels and in response to this, have a look in the development trend of sour resistant linepipe steels and its sour characteristics in welded joints.