• Title/Summary/Keyword: Thermometers

Search Result 80, Processing Time 0.028 seconds

A Systematic Review of Injury or Poisoning Related to Mercury Thermometer (수은 체온계와 관련된 손상 및 중독에 대한 체계적 고찰)

  • Lee, Yo Seop;Joo, Young Seon;You, Je Sung;Chung, Sung Phil;Chung, Hyun Soo;Lee, Hahn Shick
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.12 no.1
    • /
    • pp.22-30
    • /
    • 2014
  • Purpose: The purpose of this systematic review was to evaluate the evidence regarding injury and poisoning associated with the clinical mercury thermometer. Methods: Electronic literature searches were conducted for identification of relevant studies and case reports of injury and poisoning associated with the clinical mercury thermometer. The search outcomes were limited to literature with English and Korean languages published from 1966. Studies related to occupational mercury exposure, or mercury exposure from sphygmomanometer, barometer, and fluorescent light were excluded. Results: A total of 60 reports, including 59 case reports, were finally included. Of those, nine cases pertained to an intact thermometer as a foreign body, 25 injuries were related to a thermometer, and 26 cases involved exposures to mercury from a broken thermometer. Case reports were classified according to severity into 16 mild, 41 moderate, and two severe cases. Two cases of mortality were reported, one was deliberate intravenous injection of mercury and the other was acute vapor inhalation of mercury from broken thermometers. Conclusion: Findings of this systematic review suggested that the mercury thermometer could cause various forms of poisoning and injury. In particular, inhalation of mercury vapor from a broken thermometer can lead to systemic toxicity requiring chelating therapy.

  • PDF

Assessment and Corrective Measures of Child-care Foodservices by Sanitary Inspection Checklist Suggested by Korea Food and Drug Administration (식품의약품안전처의 위생점검표에 의한 육아지원기관 급식소 평가 및 개선대책)

  • An, Su-Jung;Moon, Hye-Kyung
    • Journal of the Korean Dietetic Association
    • /
    • v.21 no.3
    • /
    • pp.227-240
    • /
    • 2015
  • The purpose of this study was to assess the hygiene status of 145 child-care foodservices, which were newly registered in the Center for the Children's Foodservice Management (CCFSM) in Changwon, Gyeongnam. Sanitary inspection checklist (40 food safety items) of Korea Food and Drug Administration (KFDA) was used by the CCFSM in Changwon, Gyeongnam. Average score from the total safety items in 145 child-care foodservices was 21.41 points out of 40 points. Score gaps between the lower group (71 foodservices, 13.92 points) and higher group (74 foodservices, 28.61 points) showed a significant difference (P<0.001). The top five priorities of sanitary measures needing corrective actions for child-care foodservices were as follows: 'provide hand washing and sanitizing tools, and supply manuals on how to wash hands properly', 'supply record form for access/inspection', 'conduct education for cooks on standards in the selection of sanitizer for raw vegetables and proper methods to wash and sanitize raw vegetables', 'provide a refrigerator and a freezer with installed thermometers and temperature record monitoring logs', 'encourage separation of contamination operating zone and clean zone or conduct training for cooks on ways to prevent cross-contamination by performing work separately by the hour'. For the higher group, most were national/public facilities (83.3%), whereas in the lower group, private facilities (62.1%) were more common than national/public ones (37.9%). Therefore, a significant difference (P<0.001) was detected in the two groups. These private facilities should be supported.

Experiments on a Regenerator with Thermosyphon for Absorption Heat Pumps (기포 펌프를 적용한 흡수식 열펌프용 고온 재생기의 작동 특성 실험)

  • Park, C.W.;Jurng, J.;Nam, P.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.463-472
    • /
    • 1996
  • Experiments were carried out to study the operation characteristics of a regenerator with a thermo-syphon pump and a surface-flame burner for a lithium bromide (LiBr)-water absorption heat pump. A cylindrical-shape metal-fiber burner and commercial grade propane were used. The emission of carbon monoxide and nitric oxide was measured by a combustion gas analyzer. Ther regeneration rate of water vapor as a refrigerant was measured. It could be as a reference value showing the performance of the regenerator. The circulation rate of the LiBr-water solution was also measured from both the tanks for the weak-and the strong-solution. Using a refractometer, the LiBr concetration in the solution was calculated from the measured refractory index of the solution. Temperature of the solution and the condensed water was recorded at several points in the experimental apparatus with thermocouples, using a personal computer. This data collecting system for measuring temperature was calibrated with a set of standard thermometers. The generating rate of water vapor as refrigerant increased linearly with heat supplied. It was about 4.0g/s with the heat supplied at a rate of 16,500kcal/h. The circulation rate of LiBr solution also increases with the heat supplied. The difference in LiBr concentrations between the weak and the strong solution was in the range of 1 to 5% when the concentration of the strong solution was about 60%. It was dependent upon both the heat supplied and the circulation rate of the solution. The initial concentration and the level of the LiBr solution in the regenerator were measured and recorded before experiments. The effect of them on the generating rate of water vapor and the circulation rate of the solution was also studied. The generating rate of water vapor was not strongly dependent upon both the level of the LiBr solution and the initial LiBr concentration. However, the concentration difference of the solution increases with the initial level of the LiBr solution.

  • PDF

ENVIROMENTAL CONDITION DURING AIR SHIPMENT OF HORTICULTURAL PRODUCTS FROM OKINAWA TO TOKYO

  • Akinaga, Takayoshi;Kohda, Yoshihiro
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.413-422
    • /
    • 1993
  • Air shipment affords the quickest possible delivery of horticultural products. The price of air shipped horticultural products are relatively high as most of these products are perishable. Usually the temperature in the cargo compartment is not controlled during flight. Thus, special attention should be paid to procooling prior to shipment. The environmental condition during transportation of horticultural products is an essential parameter for maintaining the quality of perishable products. Commonly horticultural products were loaded by ULD(Unit Load Devices) as a container or pallet in the aircraft (except for small aircraft) . Therefore, inside temperature of the container and cargo compartment came into question. Scarce literature on the relationship between environmental condition and quality changes of horticultural products during air shipment can be found. By the stand point of keeping fresh quality, investigations on the actual condition of air shipments were carried out to improve the technique during the distribution process of fresh horticultural products. Temperature, humidity, atmospheric pressure, carbon dioxide, ethylene, impacts, and changes in quality during the air shipment of snapbeans, okras and chrysanthemums were measured. Temperature was measured by recording thermometers, relative humidity by recording hygrometers, atmospheric pressure by a strain -guage type pressure sensor, carbon dioxide by testing tubes, ethylene by sampling bags and a gaschromatograph, impacts and vibrations by impact recorders and a 3D accelerometer. Relationships between environmental conditions and quality changes during air shipments were clarified. It was expected from investigations into actual shipments that the ventilation and insulation properties of air freight containers were related to the quality of agricultural products. Aircraft can no directly load and unload trucks into them. The transshipment is inclined to cause shocks and vibrations, and to invite damages within a short time.

  • PDF

Size-of-source Effect and Self-radiation Effect of an Infrared Radiation Thermometer (적외선 복사온도계의 복사원 크기효과 및 자기복사효과)

  • Yoo, Yong-Shim;Kim, Bong-Hwak;Park, Chul-Woung;Park, Seung-Nam
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.4
    • /
    • pp.133-138
    • /
    • 2010
  • All radiation thermometers have a size-of-source effect (SSE) and a self-radiation effect (SRE). The SSE,defined as dependence of the detector signal of a radiation thermometer on the diameter of a source, is critically dependent on the wavelength since diffraction is the main cause. In this paper, we have measured the SSE and the SRE of TRT2 (Transfer Radiation Thermometer 2, HEITRONICS) widely used as a transfer standard in low and middle temperature range. At $300^{\circ}C$, The radiation temperature difference between the 60 mm diameter blackbody and 10 mm diameter blackbody due to the SSE was estimated to be $3.5^{\circ}C$ in low temperature mode ($8-14\;{\mu}m$) and $0.5^{\circ}C$ in middle temperature mode ($3.9\;{\mu}m$). In addition, the measured radiation temperature difference of the blackbody due to the SRE was found to be 110 mK when the body temperature change of TRT2 was set at $2.6^{\circ}C$.

Comparison of Tympanic and Axillary Temperatures (고막체온과 액와체온의 비교 연구 - 성인대상자를 중심으로 -)

  • Yea, Jae-Hee;Jo, Hyun-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.16 no.2
    • /
    • pp.162-170
    • /
    • 2009
  • Purpose: To verify the usability of tympanic temperature measurement for adults, a comparison of tympanic and axillary temperatures was done. Method: The study was conducted during October 2008, and participants were 110 female nursing students. Axillary temperatures were taken with glass mercury thermometers for 5, 7 and 10 minutes. Tympanic temperatures were taken with Infrared Thermometer IRT 4520 on both ears, twice at a 5-second interval. The data were analyzed using the SPSS 12.0 program. Results: In the 1st measurement, the mean for right tympanic temperatures ($0.06^{\circ}C$) and for left ($0.03^{\circ}C$) were significantly higher than the 2nd. A comparison of mean temperatures for right and left, showed that the mean for the left side on the 1st measurement was significantly higher ($0.01^{\circ}C$) than the right. Also the temperature on left side in the 2nd measurement was higher ($0.04^{\circ}C$) than the right 2nd, but not significantly higher. The mean temperature for right and left tympanic on 1 st and 2nd measurements were significantly higher than axilla for 5 minutes ($0.58^{\circ}C$), for 7 minutes ($0.52^{\circ}C$), and for 10 minutes ($0.43^{\circ}C$). The tympanic temperature was the most closely correlated with the axillary temperature at 10 minutes. Conclusion: Findings indicate that measurement of tympanic temperature is a useful alternative to axillary temperature taken for 10 minutes.

  • PDF

A Fact-finding Research Exercise into the Handling Abilities of Experimental Apparatus by Elementary School Students (초등학생의 실험 기구 조작 능력에 대한 실태 조사)

  • Park, Jae-Won;Yoon, Sang-Mi;Won, Jeong-Ae;Paik, Seoung-Hey
    • Journal of Korean Elementary Science Education
    • /
    • v.26 no.2
    • /
    • pp.161-170
    • /
    • 2007
  • This study aims at helping us improve the methods used to teach elementary school students how to handle experimental apparatus by examining their manual skills and their understanding of the alcohol lamp, spuit and thermometer. To evaluate their ability to handle each experimental apparatus, a practical skills test and knowledge evaluation sheets were developed. The evaluation was carried out with 270 students from 2 classes each in the 3rd, 4th, 5th and 6th grade of D Elementary School located in Daejeon City. For their handling ability of the alcohol lamp, the results for the practical skills test showed that the students had a very low ability in placing objects in the center of the apparatus for safe use and also in adjusting the height of the trivet to place objects so that they contact the outer flames correctly. For the spuit, the pass rate of the skills test was generally low in regards to how students should grasp a spuit and the timing and method of depressing the rubber part before dipping it into liquid. For the thermometer, on the other hand, the pass rate was relatively high in every respect. The knowledge evaluation results for the use of experimental apparatus showed a very high rate of correct answers for alcohol lamps and thermometers. The test results for spoils also produced a relatively high rate of correct answers, with the exception of the test item regarding the way that students should grasp them.

  • PDF

A Survey of the Temperature Control of Refrigerators and Freezers in Retail Food Shops (식품판매업소의 냉장.냉동 진열대의 온도 관리 조사연구)

  • 김종규
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.161-171
    • /
    • 2002
  • The number of food establishments selling raw and convenience foods are increasing in Korea, and people enjoy purchasing and eating foods at these shops. However, there are only a few reports on the temperature control of the refrigerators and freezers at retail food shops. This study was performed to investigate the temperature control of refrigerators and freezers in retail food shops in Daegu. The survey was carried out from July 20 to August 30 in 2001. The trained surveyors visited the twenty retail food shops (four department stores, eight marts/supermarkets and eight convenience stores) in the 8 major areas of Daegu and inspected the temperature control of 48 refrigerators for dairy products, fruits & vegetables, and rolled rice & sandwiches, and 52 freezers for ice cream & sherbet, frozen food, and frozen fish. The percentage of the refrigerators, and freezers with unsafe temperatures higher than the recommended safe temperature (10℃ for refrigerators, and -18℃ for freezers) was 42%; 45.8% in refrigerators; 38.5% in freezers. On an average, the bigger the size of the shop, the better than the other freezers. On the other hand, the temperature control of refrigerator for fruits & vegetables was the worst because they were usually open. Actual temperatures in the refrigerators and freezers were found to be significantly higher than the reading on the thermometers attached to the refrigerators and freezers(p<0.05). These results indicate that temperature control of refrigerators and freezers at retail food shops should be monitored several times each day, and should have strict inspection. There should be more detailed legal standard and specification for temperature control of refrigerators and freezers at retail food shops to prevent foodborne illness from unsafely stored food.

Development of a Web-Based Program for Cross-Calibration and Record Management of Radiation Measuring Equipment

  • Park, So Hyun;Lee, Rena;Kim, Kyubo;Ahn, Sohyun;Lim, Sangwook;Cho, Samju
    • Progress in Medical Physics
    • /
    • v.30 no.2
    • /
    • pp.59-63
    • /
    • 2019
  • Purpose: To manage radiation measurement equipment, a web-based management program has been developed in this study. Materials and Methods: This program is based on a web service and Java Server Pages (JSP) and employs compatibility and accessibility. Results: The first step in the workflow has been designed to create accounts for each user or organization and to log in. The program consists of two parts: fields for listed instruments, and measurement information. The instruments for measuring radiation listed in this program are as follows: ionization chambers, survey meters, thermometers, barometers, electrometers, and phantoms. Instrument properties can be put in the recording fields and browsing for associated instruments can be performed. The main part of the program is the cross-calibration for each ion chamber. For instance, the ionization chamber to be used as a relative dosimeter can be registered by cross-calibration data with a reference chamber calibrated by an accredited laboratory. This program supports methods using the central axis transfer theory for cross-calibration for the ionization chambers. The reference and field ionization chambers were placed in a solid water phantom along the beam central axis at two different depths, and then the positions were switched. Each measured value was used for calculating the cross-calibration factor. Conclusions: Because many instruments are used and managed in radiation oncology departments, systematic, traceable recording is very important. The web-based program developed in this study is expected to be used effectively in the maintenance of radiation measurement instruments.

A geothermal gradient of the upper mantle beneath Jeju-do, Korea: evidence from mantle xenoliths

  • Choi, Seong-Hee;Jwa, Yong-Joo;Lee, Han-Yeang
    • Proceedings of the Mineralogical Society of Korea Conference
    • /
    • 2000.05a
    • /
    • pp.19-19
    • /
    • 2000
  • ;Ultramafic xenoliths found in alkali basalts from Jeju-do, Korea are mostly spinel Iherzolites composed of olivine, orthopyroxene, clinopyroxene and spinel. A subordinate amount of spinel harzburgites and pyroxenites are also found. Temperatures for these xenoliths were estimated from the compositions of coexisting pyroxenes (Wood '||'&'||' Banno 1973; Wells 1977; Bertrand '||'&'||' Mercier 1985; Brey '||'&'||' Kohler 1990), the AI-solubility in orthopyroxene coexisting with olivine and spinel (Sachtleben '||'&'||' Seck 1981; Webb '||'&'||' Wood 1986), and from Fe/Mg partitioning between olivine and spinel (Ballhaus et al. 1991). Temperature estimates from the thermometers by Wells (1977) and Brey and Kohler (1990) are compatible. Average equilibrium temperatures by these two methods for spinel peridotites range from 890 to 1030$^{\circ}$C. Pressures for spinel peridotites were estimated from the geobarometer by Kohler and Brey (1991) derived from the equilibrium Ca content of olivine coexisting with clinopyroxene, and fall within the range of 12.9 to 26.3 kbar. The combination of the thermometer by Brey and Kohler (1990) and the geobarometer by Kohler and Brey (1991) yields P- T estimates for Jeju-do spinel peridotites that fall in experimentally determined spinel lherzolite field in CFMASCr system (O'Neill 1981). These P-T data sets have been used to construct the Quaternary Jeju-do geotherm, which is significantly different from the conventional conductive geotherm. The xenolith-derived geotherm has a higher T gradient at low P (13 kbar) than at high P, which may be due to perturbation of the conductive heat flow by magma underplating or overplating at the crust-mantle boundary. Temperature estimates and statistics on the xenoliths indicate that the crust/mantle boundary in Jeju-do lies at about 11 kbar (~39 km). Spinellherzolite is inferred as a main constituent rock of the uppermost lithospheric mantle beneath Jeju-do. Pyroxenites were intercalated in peridotites in similar depth and temperature as re-equilibrated veins or lens.

  • PDF