• Title/Summary/Keyword: Thermometer

Search Result 355, Processing Time 0.039 seconds

Estimation of Daytime Sensible Heat Flux using Routine Meteorological Data (정규기상관측자료를 이용한 주간의 현열 플럭스 추정)

  • 이종범;김용국;박철용
    • Journal of Environmental Science International
    • /
    • v.9 no.2
    • /
    • pp.109-114
    • /
    • 2000
  • The purpose of the present study is to develope the estimation scheme for sensible heat flux by semi-empirical approach using routine meteorological data such as solar radiation and air temperature. To compare observed sensible heat flux with estimated sensible heat flux, the sensible heat fluxes were measured by three dimensional sonic anemometer-thermometer. The field observation was performed during 1 year from December 1, 1995 to November 30, 1996 on a rice paddy field in Chunchon basin. The heat fluxes were measured at a heights of 5m and mean meteorological variables were obtained at two levels, 2.5m(or 1.5m) and 10m. Since condition of rice paddy field such as, wetness of the field, roughness length, vary widely, we devided annual data to 5 periods. Comparing with two sensible heat fluxes, the results showed that the correlation coefficients were more than 0.86. Thus, we can conclude that the estimation method of sensible heat fluxes using routine meteorological data is practical and reliable enough.

  • PDF

Programmable Digital On-Chip Terminator

  • Kim, Su-Chul;Kim, Nam-Seog;Kim, Tae-Hyung;Cho, Uk-Rae;Byun, Hyun-Guen;Kim, Suki
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1571-1574
    • /
    • 2002
  • This paper describes a circuit and its operations of a programmable digital on-chip terminator designed with CMOS circuits which are used in high speed I/O interface. The on-chip terminator matches external reference resistor with the accuracy of ${\pm}$ 4.1% over process, voltage and temperature variation. The digital impedance codes are generated in programmable impedance controller (PIC), and the codes are sent to terminator transistor arrays at input pads serially to reduce the number of signal lines. The transistor array is thermometer-coded to reduce impedance glitches during code update and it is segmented to two different blocks of thermometer-coded transistor arrays to reduce the number of transistors. The terminator impedance is periodically updated during hold time to minimize inter-symbol interferences.

  • PDF

Thermal Characteristics and Heatsink Modeling. for IGBT (IGBT의 열 특성 및 히트싱크 모델링)

  • Ryu, Se-Hwan;Bea, Kyung-Kuk;Shin, Ho-Chul;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.172-173
    • /
    • 2007
  • As the power density and switching frequency increase, thermal analysis of power electronics system becomes imperative. The thermal analysis provides valuable information on the semiconductor rating, long-term reliability. In this paper, thermal distribution of the Non Punchthrough(NPT) Insulated Gate Bipolar Transistor has been studied. For analysis of thermal distribution, we obtained experimental and simulation results by using finite element simulator, Ansys and by using photographic infrared thermometer, we compared experimental date with simulation result. and got good agreement. Also this paper provided thermal distribution of IGBT connected to heat sinks. and this results will be good information to design optimal heat sink for IGBT.

  • PDF

Study of the Fire Risk Caused by the Use of a Bimetal type Thermometer in the Drying Equipment (바이메탈식 온도센서를 적용한 건조설비에서의 화재 위험성 연구)

  • Park, Nam-Kyu;Kim, Jin-Pyo;Nam, Jung-Woo;Park, Jong-Taek;Song, Jae-Yong
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.73-78
    • /
    • 2017
  • In this paper, the fire risk using a bimetal type thermometer for construction installation is presented. Because construction equipment is used widely in the field and the site is exposed to explosions and fire by combustible gas or fume, strong restrictions on the structure and usage are applied. Moreover, the risk of fire increases as precise temperature measurements are poorly conducted via an inner temperature sensor inside construction furnace. Therefore, this paper presents the results of structural analysis of a bimetal temperature sensor which is used widely in construction installation and temperature measurement experiments relative to the material property of the target object. The results revealed the relatively precise temperature of the liquid object, whereas those of the gas and solid object showed a lower temperature compared to the real temperature. This shows that bimetal-type temperature sensor is more suitable for measuring a liquid state object than measuring a gas or solid state object.

Development of Two-color Radiation Thermometer for Harsh Environments

  • Mohammed, Mohammed Ali Alshaikh;Kim, Ki-Seong
    • Journal of ILASS-Korea
    • /
    • v.21 no.4
    • /
    • pp.184-194
    • /
    • 2016
  • Many industrial processes require reliable temperature measurements in harsh environments with high temperature, dust, humidity, and pressure. However, commercially-available conventional temperature measurement devices are not suitable for use in such conditions. This study thus proposes a reliable, durable two-color radiation thermometer (RT) for harsh environments that was developed by selecting the appropriate components, designing a suitable mechanical structure, and compensating environmental factors such as absorption by particles and gases. The two-color RT has a simple, compactly-designed probe with a well-structured data acquisition system combined with efficient LabVIEW-based code. As a result, the RT can measure the temperature in real time, ranging from 300 to $900^{\circ}C$ in extremely harsh environments, such as that above the burden zone of a blast furnace. The error in the temperature measurements taken with the proposed two-color RT compared to that obtained using K-type thermocouple readouts was within 6.1 to $1.4^{\circ}C$ at a temperature range from 200 to $700^{\circ}C$. The effects of absorption by gases including $CO_2$, CO and $H_2O$ and the scattering by fine particles were calculated to find the transmittance of the two wavelength bands of operation through the path between the measured burden surface and the two-color probe. This method is applied to determine the transmittance of the short and long wavelength bands to be 0.31 and 0.51, respectively. Accordingly, the signals that were measured were corrected, and the true burden surface temperature was calculated. The proposed two-color RT and the correction method can be applied to measure temperatures in harsh environments where light-absorbing gases and scattering particles exist and optical components can be contaminated.

An Experimental Study on the Applicability of Plate Thermometer in Steady and Unsteady-State Fire Conditions (정상 및 비정상상태의 화재조건에서 판형 열유속계의 적용성에 관한 실험적 연구)

  • Yun, Hong-Seok;Mun, Sun-Yeo;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.34-41
    • /
    • 2015
  • The applicability of plate thermometer (PT), which feature simple installation and low cost, was experimentally examined in steady and unsteady-state fire conditions. An infrared radiation heater and a square burner with C3H8 as fuel were used as heat sources. The relative measurement accuracy of the PT was evaluated by comparing measurements made using a Gardon-type heat flux meter. From a practical point of view and in terms of measurement accuracy, the optimal size and thickness of the PT in steady and unsteady-state fire conditions were 100 mm and 0.6 mm, respectively. These results can be explained by the conductive heat losses and thermal inertia of the PT for different sizes and thicknesses. It can be also concluded that measurements of heat flux using the PT in conditions of faster fire growth rate than slow require considerable attention.

The Effect of Urban Shade Trees on the WBGT(Wet Bulb Globe Thermometer Index) (도심 녹음수의 체감온도지수(WBGT) 조절효과)

  • 주민진;이춘석;류남형
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.32 no.3
    • /
    • pp.51-59
    • /
    • 2004
  • Focusing on WBGT(Wet Bulb Globe Thermometer Index) according to the LAI(Leaf Area Index) variation of trees, this study verifies the effects of urban shade trees on the outdoor thermal environment. As for methodology, air$.$globe temperature, air humidity and WBGT were measured under three shade trees whose LAIs were 2.1, 4.0 and 8.2 respectively at midday(12:00-13:00) of 14 sunny days from the 4th through the 29th day of September 2003. Those factors were also measured at the unshaded areas and compared with the values of shaded areas. The measured site was paved with interlocking concrete bricks. The measurements were analyzed through the ANCOV A(Analysis of Covariance) and the regression routines of SPSS11 for windows (SPSS Inc., 2001). The major findings were as follows. 1. The direct correlation between WBGT and LAI was very low. On the contrary, the WBGT showed close correlation with air$.$globe temperature and air humidity, and the LAI also showed very close correlation with globe temperature. These results tell that dominant shading effect by the tree is on the screening of direct solar radiation which lower the globe temperature and WBGT consequently. 2. While the average globe temperatures and WBGT at unshadowed area were 40.4$^{\circ}C$ and 26.2$^{\circ}C$ respectively, the former under the shade tree with LAI 2.1, 4.0 and 8.2 were 34.5$^{\circ}C$, 32.6$^{\circ}C$ and 30.2$^{\circ}C$, and the latter were 24.6$^{\circ}C$, 24$^{\circ}C$ and 23.4$^{\circ}C$ respectively. 3. The relationship between LAI(x) and WBGT(y) can be presented with the following equation: y = 24.23+1.53 $e^{-x}$+0.36x $e^{-x}$+0.46 $x^2$ $e^{-x}$ ($R^2$ =.98) =.98)

Establishment of Comparison Calibration Equipment for Infrared-radiation Thermometers Below ℃ (℃ 이하 적외선 복사온도계 비교 교정장치 구축)

  • Yoo, Yong Shim;Kim, Bong-Hak
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.2
    • /
    • pp.70-76
    • /
    • 2018
  • Comparison calibration equipment for infrared-radiation thermometers below $0^{\circ}C$ has been established, using a TRT2 (transfer radiation thermometer 2, HEITRONICS) as a transfer standard and an ME30 (Model: ME30, HEITRONICS) as a variabletemperature blackbody. The TRT2 was calibrated using three fixed points (Ice ($0.01^{\circ}C$), In ($156.5985^{\circ}C$), and Sn ($231.928^{\circ}C$)) and the Planckian Sakuma-Hattori equation, and including the interpolation and extrapolation errors at $-50^{\circ}C$ in the uncertainty. The pneumatic lid is installed upon opening of the ME30 and is opened for only 30 seconds for measuring the radiation temperature, which prevents formation of ice in the ME30 and also reduces the calibration time to half. The farther away from the $0{\sim}232^{\circ}C$ region, the larger the uncertainty of the comparison calibration equipment becomes. The expanded uncertainty of the comparison calibration equipment was estimated as 0.26 K at $-20^{\circ}C$.

A Fact-finding Research Exercise into the Handling Abilities of Experimental Apparatus by Elementary School Students (초등학생의 실험 기구 조작 능력에 대한 실태 조사)

  • Park, Jae-Won;Yoon, Sang-Mi;Won, Jeong-Ae;Paik, Seoung-Hey
    • Journal of Korean Elementary Science Education
    • /
    • v.26 no.2
    • /
    • pp.161-170
    • /
    • 2007
  • This study aims at helping us improve the methods used to teach elementary school students how to handle experimental apparatus by examining their manual skills and their understanding of the alcohol lamp, spuit and thermometer. To evaluate their ability to handle each experimental apparatus, a practical skills test and knowledge evaluation sheets were developed. The evaluation was carried out with 270 students from 2 classes each in the 3rd, 4th, 5th and 6th grade of D Elementary School located in Daejeon City. For their handling ability of the alcohol lamp, the results for the practical skills test showed that the students had a very low ability in placing objects in the center of the apparatus for safe use and also in adjusting the height of the trivet to place objects so that they contact the outer flames correctly. For the spuit, the pass rate of the skills test was generally low in regards to how students should grasp a spuit and the timing and method of depressing the rubber part before dipping it into liquid. For the thermometer, on the other hand, the pass rate was relatively high in every respect. The knowledge evaluation results for the use of experimental apparatus showed a very high rate of correct answers for alcohol lamps and thermometers. The test results for spoils also produced a relatively high rate of correct answers, with the exception of the test item regarding the way that students should grasp them.

  • PDF