• 제목/요약/키워드: Thermodynamic cycle

검색결과 224건 처리시간 0.025초

2 중효용 흡수식 히트점프의 난방 성능 해석 (Thermodynamic Analysis of an Absorption Heat Pump Heating System with LiBr-Water Solution)

  • 원승호;이원용;정헌생
    • 태양에너지
    • /
    • 제9권3호
    • /
    • pp.73-80
    • /
    • 1989
  • This paper presents as assessment based on steady-state thermodynamic analysis and computer modeling of a double effect generation absorption heating cycle for solar air-conditioning to find operating temperature ranges. The influences of component temperatures on the heating coefficients of performance and mass flow ratio have been investigated to obtain optimum operating conditions for the proposed air conditioning system. And the single and double effect absorption cycles are compared with each other over the same range of temperatures.

  • PDF

KCl-LiCl 공정 용융염욕에서 열역학적 싸이클법에 의한 금속산화물의 용해도적 계산 (Calculations of Solubility Preduct Constants for Metal Oxides in the KCI-LiCl Eutectic Composition by Exact Thermodynamic Cycle)

  • 백영현
    • 한국표면공학회지
    • /
    • 제23권4호
    • /
    • pp.225-229
    • /
    • 1990
  • Solubility Products of metal oxides, such as Al2O3 and UO2 in KCl-LiCl eutectic composition was calculated by using an exact an exact thermodynamic. The values for Al2O3 ThO2 and UO2 were found to be 2.51$\times$10-27, 4.97$\times$10-15and 2.17$\times$10-12in mole per liter basis at 743 K, respectively. The correlation of theoretical values with those of experiment were in good agreement. It is worth to note that the exact cycle method was proved to be satisfactory in making predictions of solubillities and also solubility products of sparingly soluble metal oxides in an ionic salt system.

  • PDF

열병합 발전소의 구성안별 성능 평가 방안 - 플랜트 열성능 및 단순화 발전단가 분석 (Performance Evaluation of Combined Heat and Power Plant Configurations -Thermodynamic Performance and Simplified Cost Analysis)

  • 김승진;최상민
    • 한국연소학회지
    • /
    • 제18권3호
    • /
    • pp.1-8
    • /
    • 2013
  • Thermodynamic and economic analyses of various types of gas turbine combined cycle power plants have been performed to establish criteria for optimization of power plants. The concept of efficiency, in terms of the difference in energy levels of electricity and heat, was introduced. The efficiency of power and heat generation by power plants with other purposes was estimated, and power generation costs were figured out for various types of combined heat and power plants(i.e., fired and unfired, condensing and non-condensing modes, single or double pressure HRSG).

열교환 과정을 고려한 혼합매체 냉동사이클의 엑서지 해석 (Exergy Analysis of Refrigeration Cycle With Mixed Refrigerants Considering The Heat Exchange Process)

  • 정상권;노승탁
    • 대한설비공학회지:설비저널
    • /
    • 제16권3호
    • /
    • pp.305-314
    • /
    • 1987
  • Thermodynamic analysis of a mixed refrigerant refrigeration cycle has been performed by computing thermodynamic properties of various refrigerants. The analyses are carried cut to identify the sources and distribution of the energy degradation by irreversible processes. Heat exchange process with the surroundings produces the entropy and the irreversible loss can be reduced by the mixed refrigerant whose phase change temperature varies during the phase change processes in the evaporator and the condenser. The concept has been applied to find the minimum compression work and thus the minimum energy loss in the overall system, specifically in the case of the mixed refrigerant of R12 and R114. Parametric studies have been added to recognize the various factors affecting the system performance.

  • PDF

소용량 수소액화 파일럿 플랜트 구축을 위한 공정의 열역학 해석 (Thermodynamic Analysis of a Hydrogen Liquefaction Process for a Hydrogen Liquefaction Pilot Plant with a Small Capacity)

  • 김태훈;최병일;한용식;도규형
    • 한국수소및신에너지학회논문집
    • /
    • 제31권1호
    • /
    • pp.41-48
    • /
    • 2020
  • The present study discussed the thermodynamic analysis of the hydrogen liquefaction process to build a hydrogen liquefaction pilot plant with a small capacity (0.5 ton/day). A 2-stage Brayton cycle utilizing LNG/LN2 cold energy was suggested to be built in Korea for the hydrogen liquefaction pilot plant with a small capacity. Thermodynamic analysis on the effect of various variables on the efficiency of hydrogen liquefaction process was performed. As a result, the CASE in which the ortho-para conversion catalyst was infiltrated inside the heat exchanger showed the best process efficiency. Finally, thermodynamic analysis was performed on the effect of turbo expander compression ratio on the hydrogen liquefaction process and it was confirmed that an optimal turbo expander compression ratio exists.

Thermodynamic Calculations on the Chemical Behavior of SrO During Electrolytic Oxide Reduction

  • Jeon, Min Ku;Kim, Sung-Wook;Lee, Sang-Kwon;Choi, Eun-Young
    • 방사성폐기물학회지
    • /
    • 제18권3호
    • /
    • pp.415-420
    • /
    • 2020
  • Strontium is known as a salt-soluble element during the electrolytic oxide reduction (EOR) process. The chemical behavior of SrO during EOR was investigated via thermodynamic calculations to provide quantitative data on the chemical status of Sr. To achieve this, thermodynamic calculations were conducted using HSC chemistry software for various EOR conditions. It was revealed that SrO reacts with LiCl salt to produce SrCl2, even in the presence of Li2O, and that the ratio of SrCl2 depends on the initial concentration of Li2O dissolved in LiCl. It was found that SrO reacts with Li to produce Sr during EOR and that the reduced Sr reacts with LiCl salt to produce SrCl2. As a result, the proportions of metallic forms were lower in Sr than in La and Nd under various EOR conditions. The thermodynamic calculations indicated that the three chemical forms of SrO, SrCl2, and Sr co-exist in the EOR system under an equilibrium with Li, Li2O, and LiCl.

발전소 온배수를 이용한 1MW급 폐쇄형 해양온도차발전 성능해석 (Analysis of 1MW Closed OTEC Cycle Using Thermal Effluent and Waste Heat)

  • 김현주;이호생;정동호;문덕수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권4호
    • /
    • pp.470-476
    • /
    • 2010
  • 발전소 온배수 및 폐열을 이용한 1 MW급 폐쇄형 해양온도차발전 사이클에 대한 성능을 비교 분석하였다. 폐쇄형 해양온도차발전 사이클에 대한 열역학적 모델은 랭킨 사이클이고, 기화기 증발 열원으로 발전소 온배수를 이용하여 사이클 효율, 기화기 및 응축기 열량 등 사이클 성능을 비교 분석하였다. 발전소 온배수 온도가 증가함에 따라 기화기 내 증발 포화압력은 상승하게 되고 그로 인해 사이클 효율은 증가하였고, 총 출력 1 MW에 필요한 기화기 및 응축기 용량은 감소하였다. 따라서 발전소 온배수는 폐쇄형 해양온도차발전에서 주요한 열원으로 사용될 수 있음을 알 수 있었다. 또한, 주위 이용 가능한 폐열이 있을 때 기화기 출구 작동유체와 열교환시켜 터빈으로 유입되는 작동유체의 온도를 상승시킨다면 사이클 효율은 크게 증가할 것이다.

저온 열원의 활용을 위한 칼리나/흡수냉동 복합사이클의 성능 해석 (Performance Analysis of a Combined Cycle of Kalina and Absorption Refrigeration for Recovery of Low-Temperature Heat Source)

  • 김경훈;고형종;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제29권5호
    • /
    • pp.490-496
    • /
    • 2018
  • Recently, the power and refrigeration cogeneration based on Kalina cycle has attracted much attention for more efficient utilization of low-grade energy. This study presents a thermodynamic performance analysis of a cogeneration cycle of power and absorption refrigeration based on Kalina cycle. The cycle combines Kalina cycle (KCS-11) and absorption cycles by adding a condenser and an evaporator between turbine and absorber. The effects of ammonia mass fraction and separation pressure were investigated on the system performance of the system. Results showed that the energy utilization of the system could be greatly improved compared to the basic Kalina cycle.

LNG 냉열을 열싱크로 이용하는 유기랭킨사이클(ORC)의 작동유체에 따른 성능 특성 (Effects of Working Fluids on the Performance Characteristics of Organic Rankine Cycle (ORC) Using LNG Cold Energy as Heat Sink)

  • 김경훈;하종만;김경천
    • 한국수소및신에너지학회논문집
    • /
    • 제25권2호
    • /
    • pp.200-208
    • /
    • 2014
  • This paper presents thermodynamic performance analysis of organic Rankine cycle (ORC) using low temperature heat source in the form of sensible energy and using liquefied natural gas (LNG) as heat sink to recover the cryogenic energy of LNG. LNG is able to condense the working fluid at a very low condensing temperature in a heat exchanger, which leads to an increased power output. Based on the mathematical model, a parametric analysis is conducted to examine the effects of eight different working fluids, the turbine inlet pressure and the condensation temperature on the system performance. The results indicate that the thermodynamic performance of ORC such as net work production or thermal efficiency can be significantly improved by the LNG cold energy.

Absorption cooling R&D in Europe

  • Kuhn, A.;Petersen, S.;Riebow, D.;Sahin, D.;Ziegler, F.
    • 대한설비공학회지:설비저널
    • /
    • 제33권3호
    • /
    • pp.50-57
    • /
    • 2004
  • This article reviews absorption cooling R&D in Europe from the viewpoint of fundamentals, cycle development and applications. The review contains information on R&D, predominantly of public projects in the field of sorption cooling. We report on research which is performed in Europe with some stress on Germany. There is progress in fundamentals, thermodynamic cycle design, and also applications. In the fundamentals part the discussion about thermodynamics, working pairs, and heat and mass transfer is reflected. Today's discussion on thermodynamic cycles is not very strong. Main focus is on special solid sorption cycles, compression­sorption hybrids, and open cycles, In the applications part the chilling business is the main issue. Some interest is given to the improvement of efficiency on and the adaptation to low temperature waste heat use, but the stress is on the use of solar energy as heat source. The area of heat pumping for heating purposes is less prominent but not at all negligible. Finally, industrial heat pumping involves the reverse cycle (heat transformer, heat pump type Ⅱ) also, but there is no significant activity.

  • PDF