• 제목/요약/키워드: Thermodilution

검색결과 15건 처리시간 0.027초

인체에서 Pick 원리 및 열희석법에 의한 심박출량 측정의 비교 연구 (Comparison of Cardiac Output Determination by Direct Fick and Thermodilution Method in Man)

  • 장병철
    • Journal of Chest Surgery
    • /
    • 제14권3호
    • /
    • pp.228-234
    • /
    • 1981
  • Measurement of cardiac output by thermodilution method is easy to perform and can be repeated at very short intervals and offers a number of theoretical and practical advantages. The purpose of this paper is to reevaluate the accuracy and reproducibility of the thermodilution cardiac output by comparing the results with those obtained by the direct Fick technique. From January through April 1981 [4 months], 26 simultaneous cardiac output measurements were made using thermodilution and direct Fick methods in 12 patients in the intensive care unit of Severance Hospital following open heart surgery. The average age of the patients was $34.8{\pm}12.0$ [SD] years [range; 17-57 years]. For cardiac output determination by thermodilution technique [$CO_TD$], a Swan-Ganz Thermodilution Catheter, Model 93A-131-7F [Edwards Laboratories], a Cardiac Output Computer, Model 9520A, and Strip Chart Recorder, Model 9810 [Edwards Laboratories] were used. For the determination of cardiac output by direct Fick principle [$CO_Fick$], a Van Slyke Manometric Apparatus [Thomas] for the measurements of arteriovenous oxygen content difference and a Collin`s Respirometer with Kymograph for the measurement of oxygen consumption were used. The correlation between the simultaneously measured $CO_TD$ and $CO_Fick$ was found to be $CO_Fick$ = 0.95.$CO_TD$ + 0.1073, [r= 0.9777, P < 0.001 ]. For 26 double or triple determinations of $CO_TD$, the values ranged from 1.77 L/min to 6.66 L/min, with a reproducibility of 2.18%. The maximum difference of $CO_TD$ for $CO_Fick$ was between +11.99% and -12,99% [$Mean{\pm}SD$ = $6.07{\pm}3.97$%]. Measurement of cardiac output by thermodilution method provides a simple, rapid, reproducible and highly accurate method for multiple cardiac output measurements suitable for use at the bedside. Comparison of Cardiac Output Determination by Direct Fick and Thermodilution Method in Man.

  • PDF

Swan-Ganz Catheter를 이용한 심폐기능 이상자의 정확한 Cardiac Output 측정 플랫폼 개발 (Cardiac Output Measurement Platform Development Using Swan-Ganz Catheter in Cardiopulmonary Patients with More Accurate)

  • 정용현;나상신;김영길
    • 한국정보통신학회논문지
    • /
    • 제15권7호
    • /
    • pp.1591-1597
    • /
    • 2011
  • 본 논문에서는 심폐기능에 이상이 있는 중환자의 상태를 진단하거나 치료 방향을 정하기 위하여 심박 출량을 측정하는 플랫폼 구현에 관한 연구로써, 센서가 내장된 Swan-Ganz Catheter를 체내에 삽입 후, 생리식염수를 투입하여 생기는 온도변화량을 열희석법을 이용하여 심박출량을 구하는 방법을 사용한다. Swan-Ganz Catheter는 온도센서와 압력센서를 포함하고 있으며 이를 통해 입력되는 센서 값을 보다 세밀하게 수집한다면 심박출량, 전선 및 폐혈관저항, 산소소모량 등을 보다 정확하게 계산해 낼 수가 있으므로 환자의 상태를 보다 정확하게 진단 및 치료가 가능하게 한다.

임피던스 카디오그래피와 열희석법에 의한 심박출량의 비교 (The Comparison of Cardiac Outputs between Impedance Cardiography and Thermobilution Technique)

  • 김덕원;이웅구
    • 대한의용생체공학회:의공학회지
    • /
    • 제9권2호
    • /
    • pp.165-170
    • /
    • 1988
  • The purpose of this study was to prove the accuracy of impedance cardiography by measuring cardiac outputs of patients simultaneously by thermodilution method, and impedance cardiography developed in our department. The subjects were eight patients with mitral stenosis admitted to the cathete rization laboratory in Severance Hospital. The correlation coefficient was 0.895, which is thought quite high considering the fact that accuracy of cardiac outputs of patients with valvular diseases measured by both methods was known to be low.

  • PDF

임피던스 심장기록기의 개발과 응용 (Development of Impedance Cardiograph and its Application)

  • 김덕원;김정열;김원기;박상희
    • 대한전자공학회논문지
    • /
    • 제27권3호
    • /
    • pp.54-62
    • /
    • 1990
  • 현재 임상에서 환자의 심박출량(cardiac output)을 측정하는데 널리 쓰이는 열희석법(thermodilution)은 카테터(catheter)의 심장주입에 따르는 위험성, 부작용 및 고도의 기술요구와 측정장비 및 비용의 고가, 측정 횟수의 제한, 환자의 고통등 여러 가지 문제점을 내포하고 있다. 한편 Electrical Impedance Cardiography는 이러한 열의석법의 단점들을 해결하고 나아가서 열희석법과는 달리 계속적으로 심박출량 뿐만 아니라 박동량(stroke volume) 및 심근육의 수축력등 심장의 기계적 기능을 감시할 수 있는 방법으로서, 외국에서는 널리 쓰이고 있고 이에 대한 연구도 활발한 상태이나 국내에서는 거의 보급이 안되어 있는 설정이다. 그리하여 본 연구에서는 이 새로운 분야의 국내 보급을 위하여 시제품을 완성하고 임상에서의 표준방법인 열희석법과 동시에 측정하여 기기의 정확성을 확인하였으며 운동 중에 운동부하 증가에 따른 심장기능의 변화도 측정하였다.

  • PDF

Swan-Ganz Catheter를 이용한 심폐기능 이상자의 지속적 심박출량 측정 모듈 개발에 관한 연구 (The Study of continuous cardiac output measurement module development of the cardiopulmonary function patient of using the Swan-Ganz Catheter)

  • 한승환;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.194-197
    • /
    • 2012
  • 본 논문에서는 심폐기능에 이상이 있는 중환자의 상태를 감시 및 진단하기 위한 방법으로 Swan-Ganz Catheter를 체내에 삽입하여, 지속적인 심박출량 데이터를 기존 장비들 보다 정밀하게 측정할 수 있는 모듈을 개발하고자 한다. 이전에 차가운 수액을 심장 내에 주입하여 심박출량을 측정하는 방법은 지속적인 환자의 감시 및 진단이 힘들다는 점을 보완하여 지속적인 심박출량 측정을 통해 심폐기능 문제를 가진 중환자를 보다 효과적이고 정확한 진단과 치료를 가능하게 한다.

  • PDF

임피던스 심장기록법을 이용한 심장기능의 측정 (Measurement of Cardiac Function using Impedance Cardiography)

  • 김덕원;김정열
    • 대한의용생체공학회:의공학회지
    • /
    • 제9권1호
    • /
    • pp.109-116
    • /
    • 1988
  • In this paper, principles of impedance tenchinque and relationship between stroke volume and impedance change were theoretically explained. An impedance cardiograph was designed and constructed. Its reproducibility was verified by experiment. Until now, the peak point of dZ/dt waveform, first derivative of impedance change(${\Delta}$Z) , has been detected by software technique requiring considerable time to process. However in this paper its peak point was found using hardware for saving processing time. Useful cardiac parameters such as stroke volume and contractility of cardiac muscle were measured noninvasively. The reproducibility of the instrument was measured to be better(less than 10%) than that of clinical standard method such as thermodilution (more than 30%). Hence impedance cardiography was found to be better techique for monitoring stroke volume and myocardial contractility for pre and post operation, and pharmacological studies.

  • PDF

임피던스 방법을 이용한 심장 기능의 측정 (Measurement of Cardiac Function using Impedance Technique)

  • 김정얼;김덕원;김원기;박상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.727-730
    • /
    • 1988
  • In this paper, cardiac parameters and relationship between stroke volume and impedance change were explained, and an impedance cardiograph was designed and constructed, and its accuracy was verified by experiment. Useful cardiac parameters such as stroke volume and contractility of cardiac muscle were measured noninvasively. The reproducibility of the instrument was measured to be better(less than 10%) than that of clinical standard method such as thermodilution. Hence impedance cardiography was found to be better technique for monitoring stroke volume and contractility of patients for pre and post operation, and pharmacological studies.

  • PDF

비글견에서 심초음파를 이용한 심박출량 측정에 관한 비교 연구 (Comparative Evaluation of Cardiac Output using Echocardiography in Beagle Dogs)

  • 박기태;연성찬;이희천
    • 한국임상수의학회지
    • /
    • 제29권5호
    • /
    • pp.384-390
    • /
    • 2012
  • 본 연구는 심초음파를 이용한 심박출량 측정의 정확성을 평가하고, 수의학에서 심박출량 측정을 위해 처음 적용되는 Automated Contour Tracking method (ACT method)와 다른 심초음파 측정 방법간의 비교를 위한 목적으로 실시되었다. 따라서 본 연구에서는 흡입마취된 비글견에서 심초음파를 이용한 세가지 심박출량 측정 방법 (modified Simpson's method, left ventricular outflow method 그리고 ACT method)과 절대적 표준법으로 사용되어 오고 있는 열희석법의 성적을 비교 분석하였다. 결과의 검정은 피어슨 상관계수와 선형 회귀 분석법을 사용하였다. 실험에 사용된 실험견은 심혈관계 및 전신상태에 이상이 없는 10마리 비글견이며 호흡마취 유도하에 평가가 실시되었다. 실험은 심초음파법으로 측정한 다음 연이어 열희석법으로 측정하는 순서로 진행되었다. 세 가지 심초음파 측정법들은 모두 열 희석법과 유의적인 상관관계(p < 0.05)에 있음을 알 수 있었고 특히, 세 가지 방법 중에서는 ACT method에서 상관관계가 가장 높음을 확인할 수 있었다. 본 실험에서 심초음파를 이용한 심박출량 측정법은 절대적인 심박출량을 제시하지 못하였다. 하지만 심박출량 측정의 절대적 표준법으로 사용되는 열희석법과 유의적인 상관관계가 있음이 확인 되었으므로 심박출량의 간접적인 정보로 활용함으로써 환자의 마취시에 발생할 수 있는 혈역학적 장애의 발견이나 교정을 위해서 유용하게 사용될 수 있음을 확인하였다.

선천성 심장기형 환자에서 조기술후 심실 전부하 용적과 심박출량의 상호 관계 및 혈역학적 변화 분석 (Analysis of Relation between Ventricular Preload and Cardiac Output and Hemodynamic in the Early Postoperative Period of Congenital Heart Surgery)

  • 박승일;김응중;김용진
    • Journal of Chest Surgery
    • /
    • 제23권1호
    • /
    • pp.22-32
    • /
    • 1990
  • Postoperative cardiac performance of cyanotic congenital heart disease is somewhat different from that of other cardiac diseases. For the evaluation of postoperative cardiac performance in the cyanotic congenital heart disease we measured cardiac output by thermodilution technique at 1, 4, 8, 12, 16, 20, 24, 36, 48 postoperative hours in 14 patients operated from Feb. 1989 to Nov. 1989 in The Department of Thoracic and Cardiovascular Surgery, Seoul National University Children`s Hospital. At the same time, we checked left atrial pressure [LAP], central venous pressure [CUP], and mixed venous oxygen saturation [SvO2] to detect correlation between them. Immediate postoperative cardiac index was 3.585 $\pm$ 0.945 L/min/m2, and it decreased maximally to 3.322$\pm$1.007 L/min/m2 at postoperative 16 hours. After then it increased and stabilized from 36 hours after operation, and its value was 4.426$\pm$1.358 L/min/m2. There were no correlations between cardiac index and left atrial pressure or central venous pressure. Between mixed venous oxygen saturation and cardiac index, there was no correlation in the early postoperative period but after postoperative 16 hours, there was significant correlation between them and correlation coefficients were 0.573 [16hrs], 0.743 [20hrs], 0.436 [24hrs], 0.560 [36hrs], 0.636 [48hrs], respectively. From these results, we concluded that in the corrective surgery of cyanotic congenital heart disease, cardiac performance was depressed in the early postoperative period. It improved from postoperative 16 hours, and stabilized from 36 hours after operation. During early postoperative period, mixed venous oxygen saturation should not be used as a predictor of cardiac performance but it could be used as a predictor of cardiac performance from 16 hours after operation.

  • PDF

개심술을 시행하는 환자에서 경식도 심초음파의 이용 (The Usefulness of Transesophageal Echocardiography During Heart Surgery)

  • 조규도;김치경
    • Journal of Chest Surgery
    • /
    • 제30권12호
    • /
    • pp.1205-1213
    • /
    • 1997
  • 가톨릭대학교 의과대학 부속 성바오로 병원에서 1996년 1월부터 7월까지 개심술시 경식도심초음파를 이용하여 수술 중 관찰한 61명의 증례를 분석하여 다음과 같은 결과를 얻었다. 61명의 환자 중 질병 분류는 심장 판막 질환 25명, 관상동맥 질환 22명, 선천성 심질환 13명, 심장 판막 질환과 관상동맥 질환이 병발한 경우가 1명 이었다. 1. 경식도심초음파를 이용하여 선천성 심질환 1예(심실중격결손증 재수술)와 대동맥 판막 치환술을 시행한 환자 1예에서 일차 심정지에 의한 수술 후 잔존 단락과 판막 주위 누출이 확인되어 재심정지를 유도하여 수술을 완료하였다 2. 공기색전증의 발생을 전 예에서 방지할 수 있었다. 3. 경식도심초음파로 측정한 심박출량과 온도희석법으로 측정한 심박출량은 통계학적으로 의미있는 상관관계를 보여 경식도 초음파를 이용한 심박출량 감시가 의미 있음을 시사하였다(Linear regression analysis, p<0.001). 4. 관상동맥우회로술을 시행한 23명의 환자에서 수술 중 경식도 초음파도상 이상 벽운동을 보이는 분절의 도부타민 투여 전후와 관상동맥우회로술 후의 반응을 비교 관찰하였다. 저 용량 도부타민 검사는 통계적으 \ulcorner유의하였다(민감도 76%, 특이도 94.7%, 양성 예측율 95%, 음성 예측율 75%).

  • PDF