• Title/Summary/Keyword: Thermocycling effect

Search Result 94, Processing Time 0.024 seconds

EFFECT OF CHLORHEXIDINE ON MICROTENSILE BOND STRENGTH OF DENTIN BONDING SYSTEMS (Chlorhexidine 처리가 상아질 접착제의 미세인장결합강도에 미치는 영향)

  • Oh, Eun-Hwa;Choi, Kyoung-Kyu;Kim, Jong-Ryul;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.148-161
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of chlorhexidine (CHX) on microtensile bond strength (${\mu}TBS$) of dentin bonding systems. Dentin collagenolytic and gelatinolytic activities can be suppressed by protease inhibitors, indicating that MMPs (Matrix metalloproteinases) inhibition could be beneficial in the preservation of hybrid layers. Chlorhexidine (CHX) is known as an inhibitor of MMPs activity in vitro. The experiment was proceeded as follows: At first, flat occlusal surfaces were prepared on mid-coronal dentin of extracted third molars. GI (Glass Ionomer) group was treated with dentin conditioner, and then, applied with 2 % CHX. Both SM (Scotchbond Multipurpose) and SB (Single Bond) group were applied with CHX after acid-etched with 37% phosphoric acid. TS (Clearfil Tri-S) group was applied with CHX, and then, with adhesives. Hybrid composite Z-250 and resin-modified glass ionomer Fuji-II LC was built up on experimental dentin surfaces. Half of them were subjected to 10,000 thermocycle, while the others were tested immediately. With the resulting data, statistically two-way ANOVA was performed to assess the ${\mu}TBS$ before and after thermo cycling and the effect of CHX. All statistical tests were carried out at the 95 % level of confidence. The failure mode of the testing samples was observed under a scanning electron microscopy (SEM). Within limited results, the results of this study were as follows; 1. In all experimental groups applied with 2 % chlorhexidine, the microtensile bond strength increased, and thermo cycling decreased the micro tensile bond strength (P > 0.05). 2. Compared to the thermocycling groups without chlorhexidine, those with both thermocycling and chlorhexidine showed higher microtensile bond strength, and there was significant difference especially in GI and TS groups. 3. SEM analysis of failure mode distribution revealed the adhesive failure at hybrid layer in most of the specimen. and the shift of the failure site from bottom to top of the hybrid layer with chlorhexidine groups. 2 % chlorhexidine application after acid-etching proved to preserve the durability of the hybrid layer and microtensile bond strength of dentin bonding systems.

Influence of nano-structured alumina coating on shear bond strength between Y-TZP ceramic and various dual-cured resin cements

  • Lee, Jung-Jin;Choi, Jung-Yun;Seo, Jae-Min
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.2
    • /
    • pp.130-137
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the effect of nano-structured alumina surface coating on shear bond strength between Y-TZP ceramic and various dual-cured resin cements. MATERIALS AND METHODS. A total of 90 disk-shaped zirconia specimens (HASS CO., Gangneung, Korea) were divided into three groups by surface treatment method: (1) airborne particle abrasion, (2) tribochemicalsilica coating, and (3) nano-structured alumina coating. Each group was categorized into three subgroups of ten specimens and bonded with three different types of dual-cured resin cements. After thermocycling, shear bond strength was measured and failure modes were observed through FE-SEM. Two-way ANOVA and the Tukey's HSD test were performed to determine the effects of surface treatment method and type of cement on bond strength (P<.05). To confirm the correlation of surface treatment and failure mode, the Chi-square test was used. RESULTS. Groups treated with the nano-structured alumina coating showed significantly higher shear bond strength compared to other groups treated with airborne particle abrasion or tribochemical silica coating. Clearfil SA Luting showed a significantly higher shear bond strength compared to RelyX ARC and RelyX Unicem. The cohesive failure mode was observed to be dominant in the groups treated with nano-structured alumina coating, while the adhesive failure mode was prevalent in the groups treated with either airborne particle abrasion or tribochemical silica coating. CONCLUSION. Nano-structured alumina coating is an effective zirconia surface treatment method for enhancing the bond strength between Y-TZP ceramic and various dual-cured resin cements.

EFFECT OF METAL PRIMER TREATMENT OF THE Au-Ag-PD ALLOY SURFACE ON THE METAL-RESIN BONDING (치과용 금-은-팔라디움 합금에 대한 프라이머 처리가 금속-레진 접착에 미치는 영향)

  • Lee Kang;Lee Cheong-Hee;Jo Kwang-Hun;Kim Kyo-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.4
    • /
    • pp.417-432
    • /
    • 2001
  • The pcf metal primers on the bond strength and durability of 4-META/MMA-TBB resins adhered to an Au-Ag-Pd alloy. For this study, the specimens were divided into 8 groups as follows: Thermocyle 0 : (1) control group : sandblast, (2) Group I : sandblast + Cesead Opaque Primer; (3) Group II : sandblast + Metal Primer; (4) Group III : sandblast + V-Primer; Thermocyle 10,000 (5) control sandblast: (6) Group I : sandblast + Cesead Opaque Primer: (7) Group II : sandblast + Metal Primer; (8) Group III sandblast + V-Primer. The shear bond strength was determined using an Instron were observed with the use of scanning electron microscope. Finally, the strengths of bonded joints were evaluated with regard to their adherence energy using a wedge test. The results obtained were as follows ; (1) The shear bond strength of 4-META/MMA-TBB resin to the Au-Ag-Pd alloy was significantly improved in all the groups treated with the primers (p<0.05). (2) Regardless of the adhesive primers used, a significant difference was observed in the bond strength of the thermocycle 0 groups and 10,000 groups (p<0.05). (3) Both before and after thermocycling, the strongest bond strength between the resin an the alloy was obtained after treatment with a metal primer containing MEPS (p<0.05). (4) In the wedge test, the adherence energies of the control group and Group III decreased more rapidly than those of Group I and II during the 2nd day of storage in water.

  • PDF

Fracture load and survival of anatomically representative monolithic lithium disilicate crowns with reduced tooth preparation and ceramic thickness

  • Nawafleh, Noor A;Hatamleh, Muhanad M;Ochsner, Andreas;Mack, Florian
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.6
    • /
    • pp.416-422
    • /
    • 2017
  • PURPOSE. To investigate the effect of reducing tooth preparation and ceramic thickness on fracture resistance of lithium disilicate crowns. MATERIALS AND METHODS. Specimen preparation included a standard complete crown preparation of a typodont mandibular left first molar with an occlusal reduction of 2 mm, proximal/axial wall reduction of 1.5 mm, and 1.0 mm deep chamfer (Group A). Another typodont mandibular first molar was prepared with less tooth reduction: 1 mm occlusal and proximal/axial wall reduction and 0.8 mm chamfer (Group B). Twenty crowns were milled from each preparation corresponding to control group (n=5) and conditioned group of simultaneous thermal and mechanical loading in aqueous environment (n=15). All crowns were then loaded until fracture to determine the fracture load. RESULTS. The mean (SD) fracture load values (in Newton) for Group A were 2340 (83) and 2149 (649), and for Group B, 1752 (134) and 1054 (249) without and with fatigue, respectively. Reducing tooth preparation thickness significantly decreased fracture load of the crowns at baseline and after fatigue application. After fatigue, the mean fracture load statistically significantly decreased (P<.001) in Group B; however, it was not affected (P>.05) in Group A. CONCLUSION. Reducing the amount of tooth preparation by 0.5 mm on the occlusal and proximal/axial wall with a 0.8 mm chamfer significantly reduced fracture load of the restoration. Tooth reduction required for lithium disilicate crowns is a crucial factor for a long-term successful application of this all-ceramic system.

SHEAR BOND STRENGTH OF PORCELAIN REPAIR RESINS TO NONPRECIOUS CERAMO-METAL ALLOY (도재소부전장관 파절시 비귀금속과 도재수리용 레진간의 결합력에 관한 실험적 연구)

  • Ann, Joon-Young;Bae, Jung-Soo;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.195-209
    • /
    • 1991
  • When the porcelain fused to metal restorations were fractured at the metal interface, various techniques and materials for intraoral porcelain repair have been suggested. The purpose of this study was to investigate the effect of metal surface treatment method and water storage on the shear bond strength of four porcelain repair systems. : Clearfil(Kuraray), All-bond(Bisco), Superbond C & B(Sun Medical), Panavia OP(Kuraray). After the metal surfaces of the specimens were sandblasted by aluminum oxide or roughened by diamond point, they were stored in double deionized water(24 Hr., $37^{\circ}C$) and thermocycling was performed(24 Hr., 1024 cycles), and again half of specimes were stored in water bath(2 Months, $37^{\circ}C$). Mean shear bond strength and mode of failure were recorded. The results of this study were obtained as follows : 1. Differences were observed between the sandblasted and diamond - treated specimens in Clearfil, All-bond, and Superbond. No statistically significant differences were observed in Panavia. 2. The 2-month storage time significantly affected the bond strength of All-bond and Superbond. No statistically significant differences were observed in Clearfil and Panavia. 3. The failures were observed at the interface between opaque resin and the metal in Clearfil and All-bond. 4. The failures were observed at the interface between opaque resin and veneered resin in Panavia. The failures were observed at the interface between opaque resin and veneered resin in Superbond, but 40% of them were fractured at the interface between the metal and opaque resin after 2-month storage time.

  • PDF

AN EXPERIMENTAL STUDY FOR THE EFFECT OF ALL-BOND 2, GLUMA, SCOTCH BOND MULTI-PURPOSE (수종 상아질 접착제의 제 V급 와동에서의 미세 변연누출에 관한 비교연구)

  • Kang, Chang-Seong;Park, Seong-Ho;Lee, Chong-Suck
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.261-274
    • /
    • 1995
  • This study aimed to evaluate the marginal microleakage of Class V cavities of All-bond 2 (Wet - bonding system), Gluma (Adhesion of resin to exposed collagen fibers), and Scotchbond Multi-purpose(Mild Etching System). Hundred extracted human teeth divided into a control and three experimental groups consisting of eight teeth. The experimental group was further subdivided into All- bond2, Gluma and Scotchbond MP groups, Vitrebond served as the control. The positive control group consisted of specimens filled with resin and with no etching, primer and bonding procesure. Polished specimens underwent temperature changed from $5^{\circ}C$ to $55^{\circ}C$ a thousand times. After thermocycling, speciemens were placed in 2 % methylene blue dye solution for 24 hours in an incubator set at $37^{\circ}C$. The teeth were sectioned buccolingually and the degree of dye penetration was observed with a stereomicroscoped(*20). The following results were obtained. 1. Both the control and the experimental group showed a lower degree of dye penetration on enamel than on dentin margins(p<0.05) 2. Gluma exhibited a statistically significant lower degree of dye penetration than All-bond 2 on enamel margins(p<0.05) Scotchbond MP also exhibited a lower degree of dye penetration than All-bone 2 but was no statistically significant. Gluma and Scotchbond MP exhibited a similar degree of dye penetration. 3. The degree of dye penetration of All-bond 2, Gluma and Scotch bond MP showed no statistically singnificance on enamel margins but was significantly lower than in the control using Vitrebond. 4. All-bond 2 exhibited a statistically significant lower degree of dye penetration than Gluma on dentin margins. All- bond 2 and Scotchbond MP showed a similar degree of dye penetration. 5. The degree of dye penetration of All-bond 2, Gluma and Scotchbond MP showed no statistically significance on dentin margins. There was neither a statistical significance with the control.

  • PDF

Effect of repair methods and materials on the flexural strength of 3D-printed denture base resin

  • Viotto, Hamile Emanuella do Carmo;Silva, Marcela Dantas Dias;Nunes, Thais Soares Bezerra Santos;Coelho, Sabrina Romao Goncalves;Pero, Ana Carolina
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.5
    • /
    • pp.305-314
    • /
    • 2022
  • PURPOSE. The aim of this study was to evaluate the flexural strength of a 3D-printed denture base resin (Cosmos Denture), after different immediate repair techniques with surface treatments and thermocycling. MATERIALS AND METHODS. Rectangular 3D-printed denture base resin (Cosmos Denture) specimens (N = 130) were thermocycled (5,000 cycles, 5℃ and 55℃) before and after the different repair techniques (n = 10 per group) using an autopolymerized acrylic resin (Jet, J) or a hard relining resin (Soft Confort, SC), and different surface treatments: Jet resin monomer for 180 s (MMA), blasting with aluminum oxide (JAT) or erbium: yttrium-aluminum-garnet laser (L). The control group were intact specimens. A three-point flexural strength test was performed, and data (MPa) were analyzed by ANOVA and Games-Howell post hoc test (α = 0.05). Each failure was observed and classified through stereomicroscope images and the surface treatments were viewed by scanning electron microscope (SEM). RESULTS. Control group showed the highest mean of flexural strength, statistically different from the other groups (P < .001), followed by MMA+J group. The groups with L treatment were statistically similar to the MMA groups (P > .05). The JAT+J group was better than the SC and JAT+SC groups (P < .05), but similar to the other groups (P > .05). Adhesive failures were most observed in JAT groups, especially when repaired with SC. The SEM images showed surface changes for all treatments, except JAT alone. CONCLUSION. Denture bases fabricated with 3D-printed resin should be preferably repaired with MMA+J. SC and JAT+SC showed the worst results. Blasting impaired the adhesion of the SC resin.

Assessment of effect of accelerated aging on interim fixed dental materials using digital technologies

  • Omar, Alageel;Omar, Alsadon;Haitham, Almansour;Abdullah, Alshehri;Fares, Alhabbad;Majed, Alsarani
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.360-368
    • /
    • 2022
  • PURPOSE. This study assessed the physical and mechanical properties of interim crown materials fabricated using various digital techniques after accelerated aging. MATERIALS AND METHODS. Three groups of interim dental restorative materials (N = 20) were tested. The first group (CO) was fabricated using a conventional manual method. The second group (ML) was prepared from prefabricated resin blocks for the milling method and cut into specimen sizes using a cutting disc. The third group (3D) was additively manufactured using a digital light-processing (DLP) 3D printer. Aging acceleration treatments using toothbrushing and thermocycling simulators were applied to half of the specimens corresponding to three years of usage in the oral environment (N = 10). Surface roughness (Ra), Vickers microhardness, 3-point bending, sorption, and solubility tests were performed. A 2-way analysis of variance (ANOVA) and Fisher's multiple comparison test were used to compare the results among the groups. RESULTS. The mean surface roughness (Ra) of the resin after accelerated aging was significantly higher in the CO and ML groups than that before aging, but not in the 3D group. All groups showed reduced hardness after accelerated aging. The flexural strength values were highest in the 3D group, followed by the ML and CO groups after accelerated aging. Accelerated aging significantly reduced water sorption in the ML group. CONCLUSION. According to the tested material and 3D printer type, both 3D-printed and milled interim restoration resins showed higher flexural strength and modulus, and lower surface roughness than those prepared by the conventional method after accelerated aging.

Effect of hydrogel-based antibiotic intracanal medicaments on crown discoloration

  • Rayan B. Yaghmoor;Jeffrey A. Platt;Kenneth J. Spolnik;Tien Min Gabriel Chu;Ghaeth H. Yassen
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.52.1-52.11
    • /
    • 2021
  • Objectives: This study evaluated the effects of low and moderate concentrations of triple antibiotic paste (TAP) and double antibiotic paste (DAP) loaded into a hydrogel system on crown discoloration and explored whether application of an adhesive bonding agent prevented crown discoloration. Materials and Methods: Intact human molars (n = 160) were horizontally sectioned 1 mm apical to the cementoenamel junction. The crowns were randomized into 8 experimental groups (calcium hydroxide, Ca[OH]2; 1, 10, and 1,000 mg/mL TAP and DAP; and no medicament. The pulp chambers in half of the samples were coated with an adhesive bonding agent before receiving the intracanal medicament. Color changes (ΔE) were detected by spectrophotometry after 1 day, 1 week, and 4 weeks, and after 5,000 thermal cycles, with ΔE = 3.7 as a perceptible threshold. The 1-sample t-test was used to determine the significance of color changes relative to 3.7. Analysis of variance was used to evaluate the effects of treatment, adhesive, and time on color change, and the level of significance was p < 0.05. Results: Ca(OH)2 and 1 and 10 mg/mL DAP did not cause clinically perceivable tooth discoloration. Adhesive agent use significantly decreased tooth discoloration in the 1,000 mg/mL TAP group up to 4 weeks. However, adhesive use did not significantly improve coronal discoloration after thermocycling when 1,000 mg/mL TAP was used. Conclusions: Ca(OH)2 and 1 and 10 mg/mL DAP showed no clinical discoloration. Using an adhesive significantly improved coronal discoloration up to 4 weeks with 1,000 mg/mL TAP.

Correlation between different methodologies used to evaluate the marginal adaptation of proximal dentin gingival margins elevated using a glass hybrid

  • Hoda S. Ismail;Brian R. Morrow;Ashraf I. Ali;Rabab El. Mehesen;Franklin Garcia-Godoy;Salah H. Mahmoud
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.4
    • /
    • pp.36.1-36.17
    • /
    • 2022
  • Objectives: This study aimed to evaluate the effect of aging on the marginal quality of glass hybrid (GH) material used to elevate dentin gingival margins, and to analyze the consistency of the results obtained by 3 in vitro methods. Materials and Methods: Ten teeth received compound class II cavities with subgingival margins. The dentin gingival margins were elevated with GH, followed by resin composite. The GH/gingival dentin interfaces were examined through digital microscopy, scanning electron microscopy (SEM) using resin replicas, and according to the World Dental Federation (FDI) criteria. After initial evaluations, all teeth were subjected to 10,000 thermal cycles, followed by repeating the same marginal evaluations and energy dispersive spectroscopy (EDS) analysis for the interfacial zone of 2 specimens. Marginal quality was expressed as the percentage of continuous margin at ×200 for microscopic techniques and as the frequency of each score for FDI ranking. Data were analyzed using the paired sample t-test, Wilcoxon signed-rank test, and Pearson and Spearmen correlation coefficients. Results: None of the testing techniques proved the significance of the aging factor. Moderate and strong significant correlations were found between the testing techniques. The EDS results suggested the presence of an ion-exchange layer along the GH/gingival dentin interface of aged specimens. Conclusions: The marginal quality of the GH/dentin gingival interface defied aging by thermocycling. The replica SEM and FDI ranking results had stronger correlations with each other than either showed with the digital microscopy results.