• Title/Summary/Keyword: Thermocouples

Search Result 265, Processing Time 0.026 seconds

A Development of Test Equipment for Thermal Protection Performance on Insulator used in Rocket Motor Chamber (연소관 내열고무의 내열성능평가를 위한 시험장치 개발)

  • Kang, YoonGoo;Park, JongHo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.3
    • /
    • pp.32-36
    • /
    • 2016
  • Test equipment was designed and manufactured to evaluate thermal reaction characteristic of internal insulators of solid rocket motor. Test is allowed up to chamber pressure 2,500 psi, burn-time 100 s. A cross section of test sample part is quadrature, and various test samples can be comparable at the same time. Inner temperature of test sample can be measured by thermocouples during burning. Test was executed in condition of efficient average chamber pressure 1,000 psi, efficient burn-time 10 s and safety of equipment was confirmed. Basic data for understanding thermal characteristics of internal insulator, that is, pressure-time curve, temperature-time curve in the test sample, and thermal destruction thickness of test sample was gained successfully.

Experimental Study on Millimeter Scale Two Phase Catalytic Reactor (밀리미터 스케일의 이상 분해 반응기에 대한 실험적 연구)

  • Cho, Chung-Hun;Lee, Dae-Hoon;Kwon, Se-JIn
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.265-270
    • /
    • 2004
  • Experiment study on a down scaled two-phase catalytic reactor is presented. As a preliminary step for the development of catalytic reactor, nano-particulate catalyst was prepared. Perovskite La$\_$0.8/Sr$\_$0.2/CoO$_3$is chosen and synthesized as a catalyst considering superior catalytic performance in reduction and oxidation process where oxygen is involved among the reagent. Reactor that has a scale of 2${\times}$10${\times}$25mm was made by machining of A1 block as a layered structure considering further extension to micro-machining. Hydrogen peroxide of 70wt% was adopted as reactant and was provided to the reactor loaded with 1.5 g of catalyst. Reactant flow rate was varied by precision pump with a range of 0.15cc/min to 17.2cc/min. Temperature distribution within reactor was recorded by 3 thermocouples and total amount of liquid product was measured. Temperature distribution and factors that affect temperature were observed and relation between temperature distribution and production rate was also analyzed. Relative time scale plays a significant role in the performance of the reactor. To obtain steady state operation, appropriate ratio of flow rate, catalyst mass and reactor geometry is required and furthermore to get more efficient production rate temperature distribution should be evenly distributed. The database obtained by the experiment will be used as a design parameter for micro reactor.

A Study on Cooling of Hot Steel Surface by Water-Air Mixed Spray(I) -The Effect of Air Mass Flux on Film Boiling Heat Transfer- (물-공기 혼합분무에 의한 고온 강판 냉각에 대한 연구 (I) -막비등 열전달에 대한 공기질량유속의 영향-)

  • Lee, Pil-Jong;Jin, Sung-Tae;Lee, Sung-Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.247-255
    • /
    • 2004
  • The cooling characteristic of water-air mixed spray for high water mass flux is not well defined, compared to that of highly pressurized spray. A series of research program was planned to develop the boiling correlation for whole temperature range in case of water-air mixed spray with high water mass flux. The cooling experiments of hot steel surface with initial temperature of 820$^{\circ}C$ were conducted in unsteady state with relatively high water mass flux. A computer program was developed to calculate the heat flux inversely from measured data by three inserted thermocouples. Finally the effects of water and air mass flux on the averaged film boiling heat flux and wetting temperature were studied. In this 1st report, it is found that the boiling curve was similar to that of highly pressurized spray and the decreased slope of heat flux in film boiling region with respect to surface temperature became steep by increasing air mass flux. Also it is shown that, by increasing air mass flux, the averaged heat flux in film boiling region was increased, and then saturated and the wetting temperature was increased, and then decreased. Finally when the heat flux in film boiling region is compared with that of highly pressurized spray, it is known that the cooling is improved by introducing air up to 60%.

An Experimental Study on Effect of a Partitioned Electric Heating on Temperature Distribution in a Diesel Particulate Filter (분할형 전기히터 가열이 디젤 차량 배기가스저감장치 필터 내의 온도 분포에 미치는 영향에 관한 실험적 연구)

  • Lee, Choong-Hoon;Park, Sung-Chun
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.2
    • /
    • pp.151-157
    • /
    • 2008
  • The DPF temperature distribution which has a great effect on regenerating the ceramic filter effectively was measured at 30 locations using K-type thermocouples. Five partitioned electric heaters were used for heating the ceramic filter and they are switched ON/OFF in order. Also, the temperature distribution in the ceramic filter was measured with varying the electrical power supply to the heaters and the mass flow rate of the air supply from a blower. The uniform distribution of the air flow velocity at the inlet of the DPF make that of the temperature in the ceramic filter. The difference in heating ability between the partitioned heaters had a great effect on the temperature distribution in the ceramic filter.

Test and Analysis of Thermal Ratcheting Deformation for 316L Stainless Steel Cylindrical Structure (316L 스테인리스강 원통 구조물의 열라체팅 변형 시험 및 해석)

  • Lee, Hyeong-Yeon;Kim, Jong-Bum;Lee, Jae-Han
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.3
    • /
    • pp.479-486
    • /
    • 2002
  • In this study, the progressive inelastic deformation, so called, thermal ratchet phenomenon which can occur in high temperature structures of liquid metal reactor was simulated with thermal ratchet structural test facility and 316L stainless steel test cylinder. The thermal ratchet deformation at the reactor baffle cylinder of the liquid metal reactor can occur due to the moving temperature distribution along the axial direction as the sodium free surface moves up and down under the cyclic heat-up and cool-down transients. The ratchet deformation was measured with the laser displacement sensor and LVDTs after cooling the structural specimen which is heated up to 55$0^{\circ}C$ with steep temperature gradients along the axial direction. The temperature distribution of the test cylinder along the axial direction was measured with 28 channels of thermocouples and was used for the ratchet analysis. The thermal ratchet deformation was analyzed with the constitutive equation of nonlinear combined hardening model which was implemented as ABAQUS user subroutine and the analysis results were compared with those of the test. Thermal ratchet load was applied 9 times and the residual displacement after 9 cycles of thermal load was measured to be 1.79mm. The ratcheting deformation shapes obtained by the analysis with the combined hardening model were in reasonable agreement with those of the structural tests.

Study of Air Flow Effects on Heat Characteristics of Warm Needle Acupuncture (온침 열특성의 기류 영향에 관한 연구)

  • Kim, Jung-Wo Roy;Lee, Hye-Jung;Yi, Seung-Ho
    • Korean Journal of Acupuncture
    • /
    • v.27 no.4
    • /
    • pp.35-47
    • /
    • 2010
  • Objectives : To characterize the thermal properties of traditional warm needle and new warm needle with various air flows as an important environmental factor and to suggest the necessity of maintaining suitable environment of clinics to maximize their efficacy. Methods : We measured the temperature characteristics of traditional moxa warm needle and new moxa charcoal warm needle by applying an automatic temperature acquisition system with thermocouples while external various air flows were supplied. Temperatures of two positions at the needle body were measured while a moxa cone burned. Typical temperature characteristics like peak temperature, duration, curve shape and the efficiency of the heat stimuli by heat amount analysis were executed. Results : Both warm needles showed similar temperature curve with an increase in the air flow. Peak temperature and duration of effective heat decreased with the air flow, as shown in indirect moxibustion on garlic. The temperature change pattern by the air flow became more apparent when the total combustion heat was compared with the effective heat. The values from two positions on the needle body were significantly different, showing a distance dependency from the heat source of warm needle acupuncture. Conclusions : Thermal properties of warm needle acupuncture was observed variously with surrounding air flow of 0.0 - 0.7 m/s. It emphasized the importance of environmental control as well as the warm needle itself such as heat source and needle. The latter has already been known to deliver designated heat to subjects. It also indicated the importance of education and skill of the practitioners of warm needle acupuncture.

Temperature Distributions of the Lumbar Intervertebral Disc during Laser Annuloplasty : A Cadaveric Study

  • Lee, Min Hyung;Kim, Il Sup;Hong, Jae Taek;Sung, Jae Hoon;Lee, Sang Won;Kim, Daniel H.
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.6
    • /
    • pp.559-563
    • /
    • 2016
  • Objective : Low back pain, caused intervertebral disc degeneration has been treated by thermal annuloplasty procedure, which is a non-surgical treatement. The theoretical backgrounds of the annuloplasty are thermal destruct of nociceptor and denaturization of collagen fiber to induce contraction, to shrink annulus and thus enhancing stability. This study is about temperature and its distribution during thermal annuloplasty using 1414 nm Nd : YAG laser. Methods : Thermal annuloplasty was performed on fresh human cadaveric lumbar spine with 20 intact intervertebral discs in a $37^{\circ}C$ circulating water bath using newly developed 1414 nm Nd : YAG laser. Five thermocouples were attached to different locations on the disc, and at the same time, temperature during annuloplasty was measured and analyzed. Results : Thermal probe's temperature was higher in locations closer to laser fiber tip and on lateral locations, rather than the in depth locations. In accordance with the laser fiber tip and the depth, temperatures above $45.0^{\circ}C$ was measured in 3.0 mm depth which trigger nociceptive ablation in 16 levels (80%), in accordance with the laser fiber end tip and laterality, every measurement had above $45.0^{\circ}C$, and also was measured temperature over $60.0^{\circ}C$, which can trigger collagen denaturation at 16 levels (80%). Conclusion : When thermal annuloplasty is needed in a selective lesion, annuloplasty using a 1414 nm Nd : YAG laser can be one of the treatment options.

Thermal Property Analysis of 40 mm Long Hollow Cylinders Though Measurements and Analysis of Transient Temperatures (온도 측정과 분석을 통한 40 mm 장축공동실린더의 열적특성 고찰)

  • Shin Nae-Ho;Chung Dong-Yoon;Oh Myoung-Ho;Yoo Sam-Hyeon;Nam Seok-Ryun
    • Tribology and Lubricants
    • /
    • v.22 no.4
    • /
    • pp.190-195
    • /
    • 2006
  • A simple and effective analysis method is presented for gaining a complete transient temperatures on the internal and external surfaces of a 40 mm gun tube subjected to a series of rapid firings. Two series of temperature data for both Hs and As were measured by using two rapid response k-type surface thermocouples near the firing origin and the muzzle. With other available temperature data, patterns of temperature variations of the gun tube as a function of time variable were driven through complete evaluations of the data. It is found that overall temperature gradients which increase exponentially toward saturation temperature, actually consist of a series of linear temperature gradients corresponding to the firing sequences. Under the similar firing sequences, patterns of temperature variations fur both the surface temperatures near the chamber and those near the muzzle were found to have linear temperature gradients with different values and the same response frequencies, i.e. they had peaks and lows in temperatures at the same time. The resultant complete temperature data can be used as the fundamental bases for analysis of thermoelastic properties of the materials such as thermal strain and stress, and f3r the prediction of cannon tube life-time through calculation of wear rate.

Temperature Rise and Dielectric Characteristics of Distribution Transformers with Over-Loading Operation (배전용변압기의 부하운전에 의한 온도 및 유전특성 분석)

  • Kim, Byung-Sook;Lee, Byung-Sung;Song, Il-Keun;Han, Byoung-Sung;Joung, Jong-Man
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.104-110
    • /
    • 2007
  • Temperature rise characteristics of medium voltage class transformers and dielectric characteristics of its insulation oil according to the loading rate were investigated using the transformer that has thermocouples embedded in the windings. The hottest-spot of the transformer locates at about 2/3 height of the windings where they adjoin each other among the 3 phase windings. The temperature difference between the hottest-spot and top-oil is about $17[^{\circ}C]$ and the value keeps uniformly in short time after changing the loading rate. Capacitance of the oil varies in inverse proportion to temperature and the inclination rate is about -0.0106 that is not dependent on the aging rate. On the other hand the capacitance is increased depending on the aging rate, so the capacitance characteristics of the oil could be applied to the diagnostic technique.

An Experimental Study on the Critical Velocity Considering the Slope in Tunnel Fire (경사터널내 화재 발생시 경사도가 임계속도에 미치는 영향에 관한 연구)

  • Kim, Seung-Ryoul;Jang, Yong-Jun;Ryou, Hong-Sun
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.1
    • /
    • pp.7-12
    • /
    • 2008
  • An experimental study has been conducted to investigate the effect of tunnel slope on critical velocity by using the model funnel of the 1/20 reduced-scale applying the Floods scaling law. the square liquid pool burners were used for methanol, acetone and n-heptane fires. tunnel. Tunnel slopes varied as five different degrees $0^{\circ}$, $2^{\circ}$, $4^{\circ}$, $6^{\circ}$ and $8^{\circ}$. The mass loss rate and the temperatures are measured by a load celt and K-type thermocouples for tunnel slope. Present study results in bigger the critical velocity than the research of Atikinson and Wu using the propane burner. Therefore, when estimating the critical velocity in slope tunnel, the variations of the heat release rate is an important factor. The reason is the ventilation velocity directly affects variation of heat release rate when slope tunnel fire occurred.