• 제목/요약/키워드: Thermal-Fluid Analysis

검색결과 808건 처리시간 0.026초

Low-frequency modes in the fluid-structure interaction of a U-tube model for the steam generator in a PWR

  • Zhang, Hao;Chang, Se-Myong;Kang, Soong-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1008-1016
    • /
    • 2019
  • In the SG (steam generator) of PWR (pressurized water reactor) for a nuclear plant, hundreds of U-shaped tubes are used for the heat exchanger system. They interact with primary pressurized cooling water flow, generating flow-induced vibration in the secondary flow region. A simplified U-tube model is proposed in this study to apply for experiment and its counterpart computation. Using the commercial code, ANSYS-CFX, we first verified the Moody chart, comparing the straight pipe theory with the results derived from CFD (computational fluid dynamics) analysis. Considering the virtual mass of fluid, we computed the major modes with the low natural frequencies through the comparison with impact hammer test, and then investigated the effect of pump flow in the frequency domain using FFT (fast Fourier transform) analysis of the experimental data. Using two-way fluid-structure interaction module in the CFD code, we studied the influence on mean flow rate to generate the displacement data. A feasible CFD method has been setup in this research that could be applied potentially in the field of nuclear thermal-hydraulics.

전산유체역학을 이용한 다중 열저장공동의 이격거리별 열적 성능 분석 (Thermal Performance Analysis of Multiple Thermal Energy Storage (TES) Caverns with Different Separation Distances Using Computational Fluid Dynamics)

  • 박도현;박의섭;선우춘
    • 터널과지하공간
    • /
    • 제24권3호
    • /
    • pp.201-211
    • /
    • 2014
  • 본 연구에서는 전산유체역학 코드인 FLUENT를 이용한 열전달 해석을 통해 대규모 열에너지 저장을 위한 다중 암반공동의 이격거리별 열적 성능을 분석하였다. 저장공동 내부의 열성층화와 공동 외부로의 열손실 측면에서 열적 성능을 평가하였으며, 이격거리별로 시간경과에 따른 공동 주변 암반의 히팅 특성을 조사하였다. 분석결과, 주변 암반이 히팅되지 않은 초기 운영단계와 암반이 열적 정상상태에 도달한 장기 운영단계에서는 다중 암반공동의 이격거리에 따른 열적 성능의 차이가 거의 없는 것으로 검토되었다. 그러나 공동간 이격거리가 감소함에 따라 공동 사이의 암반이 열적 정상상태에 더 빠르게 도달하고, 이에 따라 저장공동 외부로의 열손실이 주변 암반의 열적 정상상태 조건에서의 열손실 값으로 빠르게 수렴하는 경향을 보였다. 이러한 결과는 다중 암반공동의 이격거리를 줄임으로써 주변 암반의 히팅에 소요되는 운영비용을 줄일 수 있음을 나타내며, 이로부터 다중 열저장 공동의 이격거리 결정시 공동의 건설비용과 함께 암반히팅에 대한 운영비용을 고려해야 함을 알 수 있었다.

원자로 냉각재 펌프의 과도 상태의 유동 및 열전달 해석 연구 (Flow and Heat Transfer Analysis of a Reactor Coolant Pump in Transient Conditions)

  • 허남건;김성원;유기풍;김승태
    • 한국유체기계학회 논문집
    • /
    • 제3권2호
    • /
    • pp.24-30
    • /
    • 2000
  • The structural analysis of a reactor coolant pump(RCP) of a nuclear power plant is very important for the safety assessment of the plant. Accurate boundary conditions for the heat transfer coefficient are required for reliable thermal stress analysis of the pump casing, especially in transient operations of the pump since the coolant properties are largely dependent on operational conditions. In the present study, a 3D mixed flow type coolant pump was modeled from the RCP drawings and analyzed in the steady state and number of transient flow conditions by using a commercial code STAR-CD. From the result of the computation, it is seen that the average heat transfer coefficients for the cases considered are found to be the suggested values of the manufacturer, Westinghouse Energy System. The unevenness in local heat transfer coefficients, however, is found to be considerable so that the use of average heat transfer coefficients in all boundaries might not give reliable thermal stress predictions.

  • PDF

몰드변압기의 공기덕트의 구조 변화에 따른 온도특성 해석 (Analysis of Temperature Characteristic According to Variation of Air Duct of the Cast Resin Transformer)

  • 김지호;이향범;손진근
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.256-260
    • /
    • 2015
  • In this paper, achieved rise temperature distribution about degradation phenomenon of 24 MVA distribution cast resin transformer using CFD(Computational Fluid Dynamics). Usually, life of transformer is depended on temperature distribution of specification region than thermal special quality of transformer interior. Specially, life of transformer by decline of dielectric strength decreases rapidly in case rise by strangeness transformer interior hot spot temperature value permits. Because calculating high-voltage(HV) winding and low-voltage(LV) winding of cast resin transformer and Joule's loss of core for improvement these life, forecasted heat source, and HV winding and LV winding of cast transformer rise temperature distribution of core for supply of electric power and temperature distribution of highest point on the basis of the results. Also, calculated temperature rise limit of cast resin transformer and permission maximum temperature using analysis by electromagnetic heat source. Calculated and forecasted rise temperature distribution by heat source of thermal analysis with calculated result.

경사각도 변화에 따른 태양열 집광흡수기내의 열 유체 유동에 관한 수치해석 (A Numeical Analysis on the Thermal and Fluid Flow in Solar Concentration Absorber with Tilt Angle)

  • 이용훈;배철환;배강열;정효민;정한식
    • 한국태양에너지학회 논문집
    • /
    • 제21권3호
    • /
    • pp.33-41
    • /
    • 2001
  • This paper showed the a numerical analysis of the thermal and fluid flow in solar concentration absorber with tilt angle, and the purpose of this study is to obtain the optimum tilt angle of the absorber. The boundary conditions of a numerical model were assumed as flows : (1) The heat source is located at the center of absorber (3) The bottom wall is opened and adiabatic. (3) The top, right and left walls are cooled wall. The parameters for the numerical analysis are tilt angles and Rayleigh numbers i.e., tilt angle $\theta=0^{\circ},\;15^{\circ},\;30^{\circ},\;45^{\circ},\;60^{\circ},\;75^{\circ},\;90^{\circ}$ and 101 $\leq$ Ra $\leq$ 103. The velocity vectors and isotherms were dense at wall side and the heat source. The mean Nusselt number had a maximum value at $\theta=0^{\circ}$ and showed a low value as the tilt angles were increased. Finally, the decrease rate of mean Nusselt number was appeared small with tilt angle when Rayleigh numbers were increased.

  • PDF

반응부의 유동해석을 통한 열플라즈마 가스처리기의 효율 개선 (A Study in The Efficiency Improvement of Thermal Plasma Gas Processor Through Fluid Dynamics Analysis of Reaction Zone)

  • 서문준;정진도;구경완
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.669-673
    • /
    • 2011
  • This study explores the numerical analysis method of fluid dynamics in the reaction section to improve the gas processing efficiency in the hazardous gas removal by atmospheric thermal plasma. This study also intends to contribute in technology advance to improve the processing efficiency and make the process more stable. Numerical analysis of temperature distribution in the reaction section dependent on the change in flow velocity of Ar and plasma temperature change, which are major control variables in the cracking process of HFC-23 using arc plasma, was done. The characteristic of incoming oxygen by temperature suggested that when temperature increased to 1600K, 1700K, 1800K respectively, the range of cracking temperature 1500K increased to 75.0%, 83.3%, 90.2% respectively. The temperature change of Ar by velocity change was widest in the area higher than 1500K when the velocity was 2.5m/s; however, since there was no big difference when the velocity was 2m/s, it is believed that 2 m/s would be most proper.

강제 통풍식 감귤 예건시설의 유동 해석 (Analysis of Flow Characteristics of Forced Ventilated Pre-drying Facility for Mandarin)

  • 권진경;윤홍선;정훈;이현동;이성현;문종필
    • Journal of Biosystems Engineering
    • /
    • 제35권6호
    • /
    • pp.393-400
    • /
    • 2010
  • Uniform and rapid pre-drying of mandarin is important to improve the storage quality. The aim of this study was to suggest the basic design of forced ventilated pre-drying facility for mandarin by thermal flow analysis using computational fluid dynamics software (FLUENT 6.2). Developed CFD simulation model was verified by comparison with experimental data. Airflows and temperature distributions in the five conceptional designs including existing ordinary temperature storage rooms were analyzed and appropriate basic design was determined. Analysis of the effect of arrangement of windows and exhaust fans on thermal flow in facility was carried out for more detailed design. The results of this investigation showed that the predicted airflow velocity by CFD simulation showed a good agreement with the measured value and optimum design condition for simulated forced ventilated pre-drying facility of mandarin has two exhaust fans and two windows on both sidewalls and cover on loaded mandarin.

VHVI 기유의 제품 적용 기술에 관한 연구 - 건설 중장비용 유압유 (A Study On the Application of VHVI Base Oil - Hydraulic Fluid for Construction Equipments)

  • 권완섭;문우식;윤한희;김경웅
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2003년도 학술대회지
    • /
    • pp.152-157
    • /
    • 2003
  • This study represents the newly advanced formulation of hydraulic fluids for extended drain interval and introduces the performance results of used oil samples from various excavators. The used oil samples, in this paper show that there is a sharp change in viscosity drop and moderate additive depletion when viscosity index of hydraulic oil is very high. For the extension of hydraulic fluid life, it is necessary to improve the stability of viscosity and oxidation. New target properties from the used oil analysis were proposed for extended life. Performance of newly developed hydraulic oil based on used oil analysis is compared with previously used one. The properties of new formulation are the viscosity index of 140 and improved thermal stability consists of VHVI base oil. Field test results showed the possibility of extension of fluid life. Additionally, for development of high performance product, new required properties and performances were discussed.

  • PDF

전산유체역학을 활용한 폐플라스틱열분해 반응기의 기체분산판에 대한 유동해석 (Effects of Thermal Dispersion Damage on the Pyrolysis and Reactor Relarionship Using Comutational Fluids Dynamics)

  • 한종일;박성수;김인재;나광호
    • 신재생에너지
    • /
    • 제19권4호
    • /
    • pp.53-60
    • /
    • 2023
  • The Computational Fluid Dynamics (CFD) model is a method of studying the flow phenomenon of fluid using a computer and finding partial differential equations that dominate processes such as heat dispersion through numerical analysis. Through CFD, a lot of information about flow disorders such as speed, pressure, density, and concentration can be obtained, and it is used in various fields from energy and aircraft design to weather prediction and environmental modeling. The simulation used for fluid analysis in this study utilized Gexcon's (FLACS) CODE, such as Norway, through overseas journals, for the accuracy of the analysis results through many experiments. It was analyzed that a technology for treating two or more catalysts with physical properties under low-temperature atmospheric pressure conditions could not be found in the prior art. Therefore, it would be desirable to establish a continuous plan by reinforcing data that can prove the effectiveness of producing efficient synthetic oil (renewable oil) through the application that pyrolysis under low-temperature and atmospheric pressure conditions.

ONAN 모드 4250kVA 변압기의 구조 건전성과 냉각 성능의 평가 (Evaluation of Structural Integrity and Cooling Performance of 4250 kVA Power Transformer with ONAN Mode)

  • ;김성익;조종래
    • 한국기계가공학회지
    • /
    • 제20권7호
    • /
    • pp.48-57
    • /
    • 2021
  • The main research content of this paper is to evaluate the structural integrity and the cooling performance of 4250 kVA power transformer with ONAN(Oil Natural and Air Natural) mode. The dynamic analysis is used to verify the structural safety of the transformer by seismic loading. The transformer structure is simplified and NX software is used to build a three-dimensional model, and ANSYS commercial software is used to calculate the stress and deformation by applying corresponding load. The analysis result was evaluated whether it satisfies the design requirements according to the IEEE Std 693 standard. In terms of thermal analysis to evaluate the cooling performance, the thermal physical model is used to calculate the heat exchange between the radiator and the tank in the steady state, and the result is input into the Fluent software to calculate the internal temperature field of the transformer tank, which reduces the calculation cost of thermal fluid. Comparing the simulated hot spot temperature and top oil temperature of the transformer with the calculation results of the IEC60076 classic model, it is found that the error is only 1.9%.