• 제목/요약/키워드: Thermal-Comfort

검색결과 700건 처리시간 0.022초

공군 전투조종사 비행복 착용특성 및 만족도 조사 (Research on Actual Usage and Satisfaction of ROKAF Fighter Pilot's Flight Duty Uniform)

  • 이아람;남윤자;홍유화;임소정;임채근
    • 한국의류학회지
    • /
    • 제40권4호
    • /
    • pp.669-684
    • /
    • 2016
  • This study investigates Korean fighter pilot's usage and satisfaction of a flight duty uniform (FDU). The survey was conducted from October 2014 to March 2015 using Focus Group Interview (FGI) and questionnaires. FGI collected qualitative data about duty and requirements; subsequently, surveys were performed to collect quantitative data about wearing conditions and satisfaction with FDU. The results of the FGI and the questionnaire were as follows. Type of pilot duty was divided into two parts, flight duty and ground duty. It is important to consider duties as well as factors related to survival when developing FDU. According to anthropometric data and wearing size, the basic size for apparel grading should be changed from actual size, 'M95XL' to 'M100L'. It is also necessary to improve the whole sizing system. Further studies about body form changes in pilot's movement are needed to improve mobility because the respondents perceived some restrictions at several body parts in movement with the coverall uniform. Summer FDU had a low satisfaction level in vent hole function and appearance. Furthermore, protection problems in the vent hole were also an issue. Making a seasonal classification of FDU fabric will be more effective than a vent hole to increase a pilot's thermal satisfaction. Respondents had a passive stance towards FDU reform (including pocket change); therefore, a new FDU design strategy should concentrate on improving current FDU functions like mobility (or comfort) rather than dramatic changes. Pilots complained about the quality stability of FDU; therefore, quality control by military administration as well as concrete and clear design instructions by the developer should be attained together. The results obtained in this study are expected to be used as an important basis for the further development of FDU.

- 찬바닥이 인체피부온도 및 온열적 쾌적감에 미치는 영향 - (Influence of Cold Floors on the Human Body Skin Temperatures and Thermal Comfort)

  • 김봉애
    • 대한가정학회지
    • /
    • 제31권1호
    • /
    • pp.211-223
    • /
    • 1993
  • 바닥마감재료가 다른 여름철의 찬바닥이 인체피부온도 및 온열적 쾌적감에 미치는 영향을 검토하기 위하여, 주위벽 및 천장의 온도를 기온과 거의 같게 한 항온실을 이용해서 바닥에 앉은 자세, 의자에 앉은 자세, 서 있는 자세별로 검토했다. 그 결과를 요약하면 다음과 같다. (1) 평균피부온도는 기온이 낮고 수온이 낮을수록 낮았다. Carpet 마감재료는 서 있는 자세, 바닥에 앉은 자세의 평균피부온도가 낮고 의자에 앉은 자세가 높았다. Cork 마감재료가 Carpet, Flooring 마감재료에 비해 평균피부온도가 낮았다. (2) 온냉감평가는 흑구온도가 낮게 되면$\ulcorner$중성이다$\lrcorner$혹은$\ulcorner$서늘하다$\lrcorner$쪽으로 평가하고, Cork, Carpet, Flooring 마감재료의 순으로 $\ulcorner$서늘하다$\lrcorner$쪽으로 평가 하였다. (3) 쾌적감평가는 바닥에 앉은 자세와 서 있는 자세가 의자에 앉은 자세보다 쾌적한 것으로 평가하였다. 마감재료는 Cork, Flooring, Carpet 순으로 쾌적하다고 평가 하였다. (4) 바닥마감재료에 대한 평가는 바닥에 앉은 자세의 경우, Carpet 마감재료는$\ulcorner$차가운$\lrcorner$$\ulcorner$습기찬$\lrcorner$의 평가점수가 높고, Cork 마감재료는$\ulcorner$평활한$\lrcorner$$\ulcorner$차가운$\lrcorner$$\ulcorner$감촉이 좋은$\lrcorner$$\ulcorner$딱딱한$\lrcorner$의 평가점수가 높고, Flooring 마감재료는$\ulcorner$평활한$\lrcorner$$\ulcorner$탄력성이 없는$\lrcorner$$\ulcorner$딱딱한$\lrcorner$의 평가점수가 높았다.$\ulcorner$따듯한$\lrcorner$-$\ulcorner$차가운$\lrcorner$의 평가는 바닥온도의 영향을 받아서, Cork, Flooring 마감재료가 Carpet 마감재료보다$\ulcorner$차가운$\lrcorner$의 높은 점수평가를 하였다. (5) Carpet 마감재료는 평균피부온도가 34$^{\circ}C$를 넘어도$\ulcorner$약간 시원하다$\lrcorner$는 평가이고, 서 있는 자세와 의자에 앉은 자세가 바닥에 앉는 자세보다 쾌적하다고 평가한다. Cork 마감재료는 3자세 모두 평균피부온도 33~34$^{\circ}C$의 사이에서 가장 쾌적하다. Flooring 마감재료는 온열적중성, 쾌적감의 중성의 평가가 많다. 이상의결과를 종합하면, 찬바닥이 인체에 미치는 영향은 바닥마감재료로는 Cork, Flooring이 보다 좋은 평가를 하였음으로, 여름철 바닥마감재료로서는 Cork, Flooring 마감재료가 바람직하다고 생각된다. 자세별로는 서 있는 자세는 바닥에 앉은 자세와 거의 같은 경향을 보이고, 의자에 앉은 자세는 바닥에 앉은 자세와 서 있는 자세 만큼 영향을 받지 않았다. 이후 실험결과를 중심으로 찬바닥의 경우, 보다 쾌적한 온열환경범위를 제안하려고 한다.

  • PDF

일본 온천을 중심으로 본 물을 매개로 하는 치유의 경관에서의 여성적 요소 (The Feminine Factor of the Therapeutic Landscape by Water from a Perspective of the Japanese Hot Spring)

  • 박수경
    • 한국지역지리학회지
    • /
    • 제22권3호
    • /
    • pp.529-552
    • /
    • 2016
  • 본 연구는 물을 매개로 하는 물리적 치유의 경관이 갖는 신체적, 문화적, 공간적, 경제적 의의가 어떤 형태로 여성을 중심으로 하는 공간에서 나타나는지 살펴보고, 이를 여성을 위한 쉼터로서의 기능, 여성을 위한 배려의 기능, 여성을 형상화한 기능으로 나눠 검토하는 것에 목표를 두고 있다. 여성을 위한 쉼터로서의 기능에는 신체적 의의가 가장 두드러지게 나타나며, 온천수와 온천욕, 분위기, 부대시설, 안전한 밤문화 등으로 구체화된다. 이러한 매개를 통해 여성은 자유로움, 온천수가 온전한 상태로 회귀시켜주는 힘, 끊임없이 제공받는 치유의 장치, 안전하게 보호해주는 것, 마음을 열고 자연스럽게 타인과의 교류 등을 느끼게 된다. 다음으로 여성을 위한 배려의 기능에서는 물을 매개로 하는 치유의 경관이 갖는 문화적 의의가 두드러지게 되는데, 이는 온천에서 발견할 수 있는 문화이기도 하지만, 배려에 바탕을 둔 일본의 문화가 자연스럽게 혼합되어 나타나는 현상이라 할 수 있다. 예를 들어, 송영버스, 오카미상 혹은 나카이상의 서비스, 장식품, 장난스러운 설치물, 개인공간의 확보 등을 통해서 다양한 즐거움을 느낄 수 있고, 누군가 지지해주고 혹은 지켜주고 있다는 느낌을 받게 되며, 신체적인 아름다움뿐만 아니라 정신적인 아름다움까지도 추구하게 된다. 마지막으로 여성을 형상화한 기능은 문화적, 공간적, 경제적 의의 등 폭넓게 나타나는데, 광고매체, 온천과 관련된 표식, 신사, 오브제, 상품화된 매개체 등을 통해 다양하게 드러난다. 이러한 기능은 건강함, 쉼, 편안함, 친숙함 혹은 익숙함, 사랑이 이루어지거나 혹은 행복한 결혼 생활로 이어진다는 이미지 등으로 승화된다. 이상을 통해 온천을 중심으로 나타나는 여성을 위한 치유의 요소는 자유로움, 안전함, 신체를 뛰어넘는 효과, 즐거움, 치유의 지속성, 아름다움, 희망 등으로 수렴되며, 이러한 요소들이 유기적으로 결합될 때 여성의 온전하지 않음은 온전함으로 회복되는 치유의 효과가 드러나는 것이라 할 수 있다.

  • PDF

조경용 차양막 재료의 명도가 하절기 옥외공간의 평균복사온도에 미치는 영향 (The Influence of the Landscaping Shade Membrane's Brightness on the Mean Radiant Temperature(MRT) of Summer Outdoor)

  • 이춘석;류남형
    • 한국조경학회지
    • /
    • 제43권5호
    • /
    • pp.65-73
    • /
    • 2015
  • 조경용 차양막의 명도가 하절기 옥외공간에서 인간이 느끼는 온열쾌적성에 어떤 영향을 미치는 지를 객관적으로 검증하기 위하여 흑색과 백색 차양막으로 2.5m의 피라미드형 시험구를 조성하여 그 하부 공간의 평균복사온도 변화 특성을 비교 분석하였다. 그리고 현실적인 적용가능성을 검토하기 위하여 95% 일사차단율의 농업용 통기성 흑색 차양망 하부와 비교 검토하였다. 지면으로부터 1.1m, 1.7m, 2.4m 지점에서 계측된 평균복사온도를 비교한 결과, 차양이 없는 대조구의 평균복사온도가 $41.8^{\circ}C$일 때, 막면과 인접한 지상 2.4m 지점의 평균복사온도는 흑색 및 백색막과 통기성 흑색망에서 각각 $49.1^{\circ}C$, $41.6^{\circ}C$, $36.8^{\circ}C$로 분석되어, 흑색막 아래의 값이 현저히 높은 것으로 나타났다. 그러나, 실제 사람이 체감하는 범위인 지상 1.7m 지점의 평균값은 $37^{\circ}C$, $38^{\circ}C$, $33^{\circ}C$로 분석되어 재료의 명도에 의한 차이는 크지 않은 것으로 나타났는데, 이 높이 이하의 위치에서는 흑색막보다 백색막 아래의 평균복사온도 값이 미세하게나마 높은 것으로 나타났다. 통기성 흑색망의 경우 모든 높이에서 가장 낮은 평균복사온도를 보여서 하절기 열환경 개선측면에서 가장 효과적인 것으로 나타났다. 시험에 사용된 차양막 소재의 일사 반사 및 흡수 특성을 분석한 결과, 동일 소재라도 색상의 밝기에 따라서 일사의 반사율과 흡수율, 투과율에서 차이가 발생됨이 확인되었다. 흑색막의 경우, 일사 반사율은 낮고, 흡수율은 높아 막 자체의 온도가 현저히 높아지는 것으로 나타난 반면, 일사 투과율은 상대적으로 낮은 것으로 평가되었다. 백색막의 경우, 일사반사율은 높은 반면, 일사 흡수율이 낮아 막면 자체의 온도는 상대적으로 낮았으나, 일사투과율은 상대적으로 높은 것으로 평가되었다. 결과적으로 막면의 장파복사량과 표면온도는 흑색이 높게 나타났으나, 실제 사람들의 체감 범위에서의 평균복사온도는 흑색막 아래가 미세하게나마 더 낮아지는 결과가 나타난 것은 백색막의 상대적으로 높은 일사투과율의 영향인 것으로 판단되었다.

조경용 차양 재료의 공극률이 하절기 옥외공간 평균복사온도에 미치는 영향 (The Influence of the Landscaping Shade Materials' Porosity on the Mean Radiant Temperature(MRT) of Summer Outdoors)

  • 이춘석;류남형
    • 한국조경학회지
    • /
    • 제45권2호
    • /
    • pp.60-67
    • /
    • 2017
  • 하절기 옥외공간에서 조경용 차양 소재의 공극률 차이에 따른 온열환경의 개선 효과를 객관적 물리량으로 검증하기 위해, 도심 건물 옥상에 조성된 암상자 상단에 공극률을 달리한 흑색 막소재의 차양을 설치하고, 그 하부의 평균복사온도의 차이를 계측하여 비교하였다. 적용된 공극률은 각각 0.5, 1. 2, 4, 8, 16, 32% 였으며, 2016년 8월에서 11월까지 세 조씩 순차적으로 비교되었다. 일 최고 흑구온도가 $30^{\circ}C$ 이상인 날의 오전 11시부터 오후 3시까지의 자료를 비교한 결과, 차양과 측벽이 설치되지 않는 개방구의 평균복사온도가 $44.26^{\circ}C$일 때, 무측벽-유차양구, 유측벽-무차양구, 유측벽-유차양구의 값은 각각 33.08, 45.80, $42.03^{\circ}C$로 차양과 측벽 유무에 의한 명확한 차이가 확인되었다. 측정 시기별 평균복사온도 기준치를 보정하기 위하여 대조구의 값을 공변량으로 공극률에 따른 값을 공분산분석(ANCOVA)한 결과, 유측벽-무차양구의 평균 값이 $45.80^{\circ}C$일 때, 0.5, 1, 2, 4, 8, 16, 32% 공극률 차양 하부의 값은 각각 43.40, 43.10, 41.49, 40.43, 39.61, 37.91, $38.12^{\circ}C$로 계산되었다. 공극률과 평균복사온도 사이에는 약 22.5%의 공극률을 최저점으로 하는 U자형의 2차 함수의 관계가 있는 것으로 분석되었다. 결론적으로, 본 연구를 통해서 차양의 공극률이 높아질수록 일정 수준까지는 평균복사온도를 저감시키는 효과가 있음을 확인할 수 있었으며, 그 한계값은 물리적 측정치로는 16%였으며, 통계적 추정치로는 약 22.5%였다.

공기조화, 냉동 분야의 최근 연구 동향: 2006년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006)

  • 한화택;신동신;최창호;이대영;김서영;권용일
    • 설비공학논문집
    • /
    • 제20권6호
    • /
    • pp.427-446
    • /
    • 2008
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 has been accomplished. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro heat exchanger and siphon cooling device using nano-fluid. Traditional CFD and flow visualization methods were still popular and widely used in research and development. Studies about diffusers and compressors were performed in fluid machinery. Characteristics of flow and heat transfer and piping optimization were studied in piping systems. (2) The papers on heat transfer have been categorized into heat transfer characteristics, heat exchangers, heat pipes, and two-phase heat transfer. The topics on heat transfer characteristics in general include thermal transport in a cryo-chamber, a LCD panel, a dryer, and heat generating electronics. Heat exchangers investigated include pin-tube type, plate type, ventilation air-to-air type, and heat transfer enhancing tubes. The research on a reversible loop heat pipe, the influence of NCG charging mass on heat transport capacity, and the chilling start-up characteristics in a heat pipe were reported. In two-phase heat transfer area, the studies on frost growth, ice slurry formation and liquid spray cooling were presented. The studies on the boiling of R-290 and the application of carbon nanotubes to enhance boiling were noticeable in this research area. (3) Many studies on refrigeration and air conditioning systems were presented on the practical issues of the performance and reliability enhancement. The air conditioning system with multi indoor units caught attention in several research works. The issues on the refrigerant charge and the control algorithm were treated. The systems with alternative refrigerants were also studied. Carbon dioxide, hydrocarbons and their mixtures were considered and the heat transfer correlations were proposed. (4) Due to high oil prices, energy consumption have been attentioned in mechanical building systems. Research works have been reviewed in this field by grouping into the research on heat and cold sources, air conditioning and cleaning research, ventilation and fire research including tunnel ventilation, and piping system research. The papers involve the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies on indoor air quality took a great portion in the field of building environments. Various other subjects such as indoor thermal comfort were also investigated through computer simulation, case study, and field experiment. Studies on energy include not only optimization study and economic analysis of building equipments but also usability of renewable energy in geothermal and solar systems.

외기 온도와 난방 출력의 철도차량 객실 온도에 대한 영향 연구 (Study of the Effects of Ambient Temperature and Car Heater Power on the Train Cabin Temperature)

  • 조영민;박덕신;권순박;정우성
    • 한국산학기술학회논문지
    • /
    • 제15권9호
    • /
    • pp.5877-5884
    • /
    • 2014
  • 최근 기후변화와 기상이변 등으로 동절기에 더욱 가혹한 기상 조건이 자주 보고되고 있다. 그러나, 철도차량의 난방용량은 이렇게 극도로 추운 기후환경에서는 객실을 난방하기에 충분하지 않은 경우가 많으며, 이는 난방에 대한 승객의 민원을 야기하는 주요 원인이 되고 있다. 본 연구에서는 외기 온도와 난방 출력이 객실 온도에 미치는 영향을 알아봄으로써 차량의 난방용량에 따른 운행 가능한 외기온도를 실험적으로 도출하고자 하였다. 실험방법으로는 우선 시험용 철도차량을 대형 기후환경 챔버에 넣고, 다양한 외기온도조건을 모사하였다. 난방 장치 출력의 영향은 난방 장치의 출력을 변화시키면서 객실의 온도를 측정하여 조사하였다. 외기온도가 $-10^{\circ}C$인 조건에서는 난방기의 출력을 최대로 한 경우에도 객실의 평균 온도는 $14.0^{\circ}C$에 불과하여, 동절기의 객실온도 최소 요구조건인 $18^{\circ}C$보다 훨씬 낮았으나, 외기 온도가 $0^{\circ}C$$10^{\circ}C$인 경우의 객실온도는 각각 $26.1^{\circ}C$$34.0^{\circ}C$였다. 내삽법으로 계산한 결과 객실 내부 온도를 $18^{\circ}C$ 이상으로 유지할 수 있는 최저 외기온도는 $-6.7^{\circ}C$임을 알 수 있었다. 객실 내부에서의 수직 온도 차이는 난방기 출력이 높을수록, 외기온도가 높을수록 커서 10 K 이상 차이가 나는 경우도 있었다. 그러나, 수평 온도 차이는 난방기 출력이나 외기온도에 무관하게 최대 2 K 이하로 매우 낮게 나타났다. 따라서, 우수한 난방성능을 확보하기 위해서는 수직 온도 차이를 줄이는 것이 중요함을 알 수 있었다.

Review of Production, Husbandry and Sustainability of Free-range Pig Production Systems

  • Miao, Z.H.;Glatz, P.C.;Ru, Y.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제17권11호
    • /
    • pp.1615-1634
    • /
    • 2004
  • A review was undertaken to obtain information on the sustainability of pig free-range production systems including the management, performance and health of pigs in the system. Modern outdoor rearing systems requires simple portable and flexible housing with low cost fencing. Local pig breeds and outdoor-adapted breeds for certain environment are generally more suitable for free-range systems. Free-range farms should be located in a low rainfall area and paddocks should be relatively flat, with light topsoil overlying free-draining subsoil with the absence of sharp stones that can cause foot damage. Huts or shelters are crucial for protecting pigs from direct sun burn and heat stress, especially when shade from trees and other facilities is not available. Pigs commonly graze on strip pastures and are rotated between paddocks. The zones of thermal comfort for the sow and piglet differ markedly; between 12-22$^{\circ}C$ for the sow and 30-37$^{\circ}C$ for piglets. Offering wallows for free-range pigs meets their behavioural requirements, and also overcomes the effects of high ambient temperatures on feed intake. Pigs can increase their evaporative heat loss via an increase in the proportion of wet skin by using a wallow, or through water drips and spray. Mud from wallows can also coat the skin of pigs, preventing sunburn. Under grazing conditions, it is difficult to control the fibre intake of pigs although a high energy, low fibre diet can be used. In some countries outdoor sows are fitted with nose rings to prevent them from uprooting the grass. This reduces nutrient leaching of the land due to less rooting. In general, free-range pigs have a higher mortality compared to intensively housed pigs. Many factors can contribute to the death of the piglet including crushing, disease, heat stress and poor nutrition. With successful management, free-range pigs can have similar production to door pigs, although the growth rate of the litters is affected by season. Piglets grow quicker indoors during the cold season compared to outdoor systems. Pigs reared outdoors show calmer behaviour. Aggressive interactions during feeding are lower compared to indoor pigs while outdoor sows are more active than indoor sows. Outdoor pigs have a higher parasite burden, which increases the nutrient requirement for maintenance and reduces their feed utilization efficiency. Parasite infections in free-range pigs also risks the image of free-range pork as a clean and safe product. Diseases can be controlled to a certain degree by grazing management. Frequent rotation is required although most farmers are keeping their pigs for a longer period before rotating. The concept of using pasture species to minimise nematode infections in grazing pigs looks promising. Plants that can be grown locally and used as part of the normal feeding regime are most likely to be acceptable to farmers, particularly organic farmers. However, one of the key concerns from the public for free-range pig production system is the impact on the environment. In the past, the pigs were held in the same paddock at a high stocking rate, which resulted in damage to the vegetation, nutrient loading in the soil, nitrate leaching and gas emission. To avoid this, outdoor pigs should be integrated in the cropping pasture system, the stock should be mobile and stocking rate related to the amount of feed given to the animals.

위성영상을 이용한 도시녹지의 기온저감 효과 분석 (An Application of Satellite Image Analysis to Visualize the Effects of Urban Green Areas on Temperature)

  • 윤민호;안동만
    • 한국조경학회지
    • /
    • 제37권3호
    • /
    • pp.46-53
    • /
    • 2009
  • 위성영상 자료를 이용하여 녹지가 주변 도시지역 기온저감에 영향을 미치는 범위를 분석하는 방법을 제시하였다. Landsat 5 TM Band 6에서 표면온도를 추출하고, 이를 자동기상관측소의 실측기온을 이용하여 기온으로 보정하였다. 위와 같은 방법으로 위성영상으로부터 지표온도를 추출 보정한 후 녹지가 도시기온에 미치는 영향을 살펴보기 위하여 등온선도를 작성하였다. 기온이 거리에 따라 급격하게 변화하는 지역을 기온완화구간이라고 정의하고, 100m당 $0.1^{\circ}C$ 이상의 기온저감을 기준으로 기온완화효과 영역을 설정하였다. 위와 같은 방법으로 수혜면적을 도출한 후 해당행정구역 내 인구가 동일하게 분포한다고 가정하여 기온저감수혜인구를 도출하였다. 본 연구의 결과는 다음과 같다. 녹지의 기온저감영향이 녹지로부터 반경 500m까지 미친다는 선행연구를 토대로 기준을 설정할 경우 시가지 중 100m 당 $0.1^{\circ}C$ 이상의 기온저감 영향을 받는 면적은 $67.33km^2$로 전체 서울시 면적의 11.12%, 시가지면적을 기준으로 할 경우 18.09%를 차지한다. 서울시민이 시가지에 등밀도로 거주한다고 가정하면 2008년 1/4분기 기준으로 서울시 인구 10,456,095명 중 약 1,892,000명을 기온저감 수혜인구로 추정할 수 있다. 또한, 기온저감 영향권역 단면 50곳을 임의로 선정하여 단면도를 작성한 결과, 녹지의 경계부와 시가지의 기온은 평균 $0.78^{\circ}C$ 차이가 났으며, 최저 $0.3^{\circ}C$, 최대 $1.7^{\circ}C$의 차이를 보였다. 이를 통해 열섬완화측면에서 법률상 공원의 유치거리 및 배치의 적절성을 분석하여 향후 공원 조성 시 인간의 이용측면만이 아닌 열섬완화 및 열 쾌적성을 고려한 새로운 기준작성의 기초자료로 활용 가능하다.

하절기 조경용 녹음수 수관 하부의 일사와 평균복사온도 비교 (The Comparison of the Solar Radiation and the Mean Radiant Temperature (MRT) under the Shade of Landscaping Trees in Summertime)

  • 이춘석;류남형
    • 한국조경학회지
    • /
    • 제42권5호
    • /
    • pp.22-30
    • /
    • 2014
  • 조경용 녹음수가 하절기 옥외공간에서 인간이 느끼는 열쾌적성에 미치는 효과를 객관적으로 검증하기 위하여 수형이 서로 다른 미국참나무, 배롱나무, 참느릅나무 등 세 종의 수목를 선정하여 일사차단율과 평균복사온도 저감 효과를 비교분석하였다. 또한, 주기적으로 수관부 사진을 촬영하여 수관부의 변화특성도 비교 검토하였다. 일사량과 건구온도, 흑구온도를 현장에서 자동으로 계측 기록할 수 있는 시스템을 구축하여 각 수목의 수관 하부에 지면으로부터 1.1m 위치에 설치하고, 2013년 4월 1일부터 동년 11월 30일까지 매 분 단위로 기록될 수 있도록 설정하였다. 수관의 천공차폐율 분석결과, 비교적 일정한 상태를 유지한 것으로 나타난 2013년 6월 1일부터 동년 8월 30일까지의 자료 중, 우천과 이상 기상일 자료를 제외한 오전 10시에서 오후 2시까지의 자료를 통계 분석에 이용하였다. 10분 단위 평균값으로 환산된 총 6,640건의 흑구온도와 건구온도를 바탕으로 평균복사온도를 환산하였으며, 이를 각 시험구의 일사량과 비교 분석하였다. 분석 대상 기간 중 미국참나무와 배롱나무, 참느릅나무 수관부의 평균 천공차폐율은 각각 99%, 98%, 97%였으며, 각 수관하부에 도달한 평균 태양 복사량은 $106W/m^2$, $163W/m^2$, $202W/m^2$로 대조구의 $823W/m^2$와 비교했을 때, 최소 75%이상이 차단된 것으로 나타났다. 또한, 평균복사온도의 경우, 각각 $30.34^{\circ}C$, $33.34^{\circ}C$, $34.77^{\circ}C$로 계산되어 대조구의 $46.0^{\circ}C$와 비교했을 때, 적게는 $10^{\circ}C$에서 많게는 $16^{\circ}C$까지 수목의 수관부에 의해서 저감된 것으로 나타났다. 일사량과 평균복사온도의 관계를 회귀분석한 결과, 매우 밀접한 선형관계를 형성하고 있었으며, 설명력도 매우 높게 분석되었다. 결론적으로 본 연구를 통해서 하절기 옥외공간에서 녹음수의 수관은 일사량의 상당부분을 차단함으로써 인간이 체감하는 열쾌적성을 개선하는데 매우 중요한 역할을 하고 있다는 점을 객관적으로 확인할 수 있었다. 따라서, 옥외공간에 더 많은 녹음수와 숲을 조성하여 그늘 지역을 증가시킴으로써 인간의 하절기 옥외활동에 부정적 영향을 주고 있는 불필요한 열에너지를 현격하게 저감시켜 쾌적한 열환경을 효과적으로 조성할 수 있을 것이다.