• Title/Summary/Keyword: Thermal-Comfort

Search Result 700, Processing Time 0.027 seconds

A Study on Performance Assessment of Dry Floors Applied to Long-life Housing (장수명주택에 적용되는 건식바닥의 성능평가에 관한 연구)

  • Seo, Dong-Goo;Lee, Jong-Ho;Kim, Soo-Am;Shin, Yun-Ho;Hwang, Eun-Kyoung
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.5
    • /
    • pp.133-143
    • /
    • 2019
  • Various problems regarding the wet floor method such as its complicated process and waste of thermal storage have been raised, but the usage of dry floor recommended for long-life housing has declined due to lack of confidence on the performance of dry floor. The purpose of this study is to secure the credibility of dry floor. Under this purpose, this study considered precedent studies and established directions to secure the performance of long-life housing infill, and thus, 9 performance items (Impact sound, Smoothness, thermal comfort, sensation hardness while walking, falling safety, impact resistance, local compression load, local strength and strain at heating) were drawn. In addition, the experiment was carried out for 5 performances except for legal performance, some dry floor performances and whole spatial performance. As a result, an appropriate result from all performances except was obtained. The performance of dry floor was verified for each item from these results and it is expected to use such results as basic data on dry floor in the future.

A Survey on Actual Wearing Condition and Satisfaction of Functional Inner Winter Uniform for Male Soldiers in Korea (한국 남자 군인 기능성 방한복 내피 개발을 위한 실태 및 만족도 조사)

  • Kim, Youn Joo;Kim, Seonyoung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.5
    • /
    • pp.910-926
    • /
    • 2022
  • Suitability for the human body, freedom to move and thermal insulation are important design considerations in military clothing. This study investigates the performance and wearer-satisfaction of the functional inner winter uniform currently used in Korea; it is hoped that our data can inform the development of a future version. Interviews were conducted, in which the participants suggested various improvements. The uniforms were mainly worn for guard duty or as daily attire in cold weather. The participants chose how many layers to wear according to the current situation, rather than sticking to the layering recommended in the manual. Layering choices did not significantly affect combat efficiency but were found to affect wearers' comfort. Wearers' satisfaction was found to depend on the convenience of the clothing, whether it was in the appropriate size, freedom to move and thermal insulation. Also, this study suggests a problem with the current size system, as the analysis of size distribution, across all sizes, the range of current production is insufficient to cover the demand.

Simulation Analysis of Urban Heat Island Mitigation of Green Area Types in Apartment Complexes (유형별 녹지 시뮬레이션을 통한 아파트 단지 내 도시열섬현상 저감효과 분석)

  • Ji, Eun-Ju;Kim, Da-Been;Kim, Yu-Gyeong;Lee, Jung-A
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.51 no.3
    • /
    • pp.153-165
    • /
    • 2023
  • The purpose of this study is to propose effective scenarios for green areas in apartment complexes that can improve the connection between green spaces considering wind flow, thermal comfort, and mitigation of the urban heat island effect. The study site was an apartment complex in Godeok-dong, Gangdong-gu, Seoul, Korea. The site selection was based on comparing temperatures and discomfort index data collected from June to August 2020. Initially, the thermal and wind environment of the current site was analyzed. Based on the findings, three scenarios were proposed, taking into account both green patches and corridor elements: Scenario 1 (green patch), Scenario 2 (green corridor), and Scenario 3 (green patch & corridor). Subsequently, each scenario's wind speed, wind flow, and thermal comfort were analyzed using ENVI-met to compare their effectiveness in mitigating the urban heat island effect. The study results demonstrated that green patches contributed to increased wind speed and improved wind flow, leading to a reduction of 31..20% in the predicted mean vote (PMV) and 68.59% in the predicted percentage of dissatisfied (PET). On the other hand, green corridors facilitated the connection of wind paths and further increased wind speed compared to green patches. They proved to be more effective than green patches in mitigating the urban heat island, resulting in a reduction of 92.47% in PMV and 90.14% in PET. The combination of green patches and green corridors demonstrated the greatest increase in wind speed and strong connectivity within the apartment complex, resulting in a reduction of 95.75% in PMV and 95.35% in PET. However, patches in narrow areas were found to be more effective in improving thermal comfort than green corridors. Therefore, to effectively mitigate the urban heat island effect, enhancing green areas by incorporating green corridors in conjunction with green patches is recommended. This study can serve as fundamental data for planning green areas to mitigate future urban heat island effects in apartment complexes. Additionally, it can be considered a method to improve urban resilience in response to the challenges posed by the urban heat island effect.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2008 (설비공학 분야의 최근 연구 동향: 2008년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.715-732
    • /
    • 2009
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2008. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends in thermal and fluid engineering have been surveyed in the categories of general fluid flow, fluid machinery and piping, new and renewable energy, and fire. Well-developed CFD technologies were widely applied in developing facilities and their systems. New research topics include fire, fuel cell, and solar energy. Research was mainly focused on flow distribution and optimization in the fields of fluid machinery and piping. Topics related to the development of fans and compressors had been popular, but were no longer investigated widely. Research papers on micro heat exchangers using nanofluids and micro pumps were also not presented during this period. There were some studies on thermal reliability and performance in the fields of new and renewable energy. Numerical simulations of smoke ventilation and the spread of fire were the main topics in the field of fire. (2) Research works on heat transfer presented in 2008 have been reviewed in the categories of heat transfer characteristics, industrial heat exchangers, and ground heat exchangers. Research on heat transfer characteristics included thermal transport in cryogenic vessels, dish solar collectors, radiative thermal reflectors, variable conductance heat pipes, and flow condensation and evaporation of refrigerants. In the area of industrial heat exchangers, examined are research on micro-channel plate heat exchangers, liquid cooled cold plates, fin-tube heat exchangers, and frost behavior of heat exchanger fins. Measurements on ground thermal conductivity and on the thermal diffusion characteristics of ground heat exchangers were reported. (3) In the field of refrigeration, many studies were presented on simultaneous heating and cooling heat pump systems. Switching between various operation modes and optimizing the refrigerant charge were considered in this research. Studies of heat pump systems using unutilized energy sources such as sewage water and river water were reported. Evaporative cooling was studied both theoretically and experimentally as a potential alternative to the conventional methods. (4) Research papers on building facilities have been reviewed and divided into studies on heat and cold sources, air conditioning and air cleaning, ventilation, automatic control of heat sources with piping systems, and sound reduction in hydraulic turbine dynamo rooms. In particular, considered were efficient and effective uses of energy resulting in reduced environmental pollution and operating costs. (5) In the field of building environments, many studies focused on health and comfort. Ventilation. system performance was considered to be important in improving indoor air conditions. Due to high oil prices, various tests were planned to examine building energy consumption and to cut life cycle costs.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Fuzzy Control Application Strategy for Energy Saving in HVAC System (공조시스템의 에너지절약을 위한 Fuzzy제어 적용방안 연구)

  • Ahn, Byung-Cheon;Song, Jae-Yeob
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.3 no.2
    • /
    • pp.31-37
    • /
    • 2007
  • The fuzzy control algorithm for HVAC system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor cooling load and outdoor temperatures. The optimal set-points of control parameters with fuzzy control are supply air temperature, chilled water temperature and condenser temperature. This study has been done by using TRNSYS program in order to analyze the HVAC system response. As a result, the fuzzy control algorithm with PID algorithm shows good energy performance in comparison with conventional one.

  • PDF

Time Course of Increased Cold Tolerance Resulting from Cool Clothing in Daily Life (착의훈련을 통해 향상된 내한능력의 지속성에 대한 연구)

  • 이종민
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.6
    • /
    • pp.1003-1009
    • /
    • 1997
  • To study the time course of increased cold tolerance, the physiological responses were measured during the course of a 2-yr study (Feb. 1995~Feb. 1996) of four female college students, whose cold tolerance was proved to be increased through wearing cool clothing in daily life from Sep. 1994 to Feb. 1995. To determine their cold tolerance, subjects rested at 25$\pm$1$^{\circ}C$, then were exposed to 15$\pm$1$^{\circ}C$, 50$\pm$5% R.H. for 90min in Feb. 1995 and Feb. 1996. Subjects' rectal temperatures, mean skin temperatures, heat production, shivering onset, thermal sensations, and comfort showed no significant changes, when they were measured in 1995 and 1996. Based on these results, we can safely assume that mild cold acclimatization coming from wearing cool clothing lasts at least oneyear, that is until the following year. One of the possible explanations for this is that the subjects did not increase their clothing thermalresistances after the cold acclimatization.

  • PDF

Distribution of clothing microclimate for making comfortable military uniform (쾌적한 군복 설계를 위한 의복기후 분포)

  • Kim, Yang-Won
    • Journal of National Security and Military Science
    • /
    • s.1
    • /
    • pp.231-247
    • /
    • 2003
  • To get the basic data for making comfortable military uniforms and to examine the distribution of clothing microclimate, seasonal fluctuations of skin temperature, subjective sensation, and clothing microclimate were measured from 10 males. The subject were questioned on thermal comfort in experiment. Clothing microclimate temperature at breast, skin temperature at four sites (breast, upper arm, thigh, leg), deep body temperature at eardrum( tympanic temperature), and subjective sensation were measured for an hour in the controlled climatic chamber. The subjects felt comfortable when skin temperature were recorded $34.43^{\circ}C$ at breast, $33.53^{\circ}C$ at upper arm, $32.9^{\circ}C$ at thigh, and 32.50 at leg. Then mean skin temperature was $33.55\pm$$0.63^{\circ}C$. Clothing microclimate temperature ranged from 31.2 to $33.8^{\circ}C$, and clothing microclimate humidity ranged from 49.80~52.41%. In the comparison of these results with the microclimate of military uniforms, it needs more insulation in clothing for military uniforms. It also says that military uniforms should be made of the textiles which can control humidity.

  • PDF

Study on the International Climatic Testing Standard for Passenger Car (철도차량의 국제 기후환경 시험규격의 수행방안 연구)

  • Yoon, Young-Kwan;Cho, Young-Min;Choi, Jin-Sik;Jung, Woo-Sung;Kwon, Soon-Bark;Park, Duck-Shin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1327-1334
    • /
    • 2011
  • subway has became citizen's feet which can transport over 24 million people since the era of high oil price started. Because the request of passengers for more comfortable thermal comfort is drastically increasing, the importance of comfortable environment in the passenger car is more stressed. This paper suggests an indicator whether railroad car is fitted with suitable cooling and heating equipment by applying the international climatic testing method, UIC 553, 553-1. Specified ambient temperature, humidity, solar irradiation condition, as well as extreme outside condition, can be achieved by using an environmental chamber. The change temperature and humidity in the passenger space can be monitored to judge if the passenger room is nicely air-conditioned.

  • PDF

Characteristic of indoor air quality according to ventilation in a temporary residential building

  • Chae, Ho-Byung;Nam, Yujin;Sung, Min-Ki;Kim, Jong-Hun
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.5-12
    • /
    • 2015
  • Recently, natural disasters have unexpectedly occurred at various places in the world and the countermeasure of them become the social issues. Many of victims in disasters need temporary residential facilities above all things and many of researches have been conducted in order to develop simple, safe, and economic designs of them. Moreover, indoor thermal comfort and air quality must be considered in the facilities against a disaster, because clean and healthy space should be provided to the suffered victims. In this research, in order to estimate the indoor environment of the developed modular building for disaster preparation, CFD simulation was conducted in the various condition. In this paper, indoor air quality such as the age of air, the concentration of $CO_2$ was estimated by the case study