• Title/Summary/Keyword: Thermal storage

Search Result 1,388, Processing Time 0.029 seconds

Development of Thermal Storage System in Plastic Greenhouse(II) -Thermal performance of solar greenhouse system for hydroponic culture- (플라스틱 온실(溫室)의 열저장(熱貯藏) 시스템의 개발(開發)에 관(關)한 연구(硏究)(II) -수경재배용(水耕栽培用) 태양열(太陽熱) 온실(溫室) 시스템의 열적(熱的) 성능(性能)-)

  • Kim, Y.H.;Koh, H.K.;Kim, M.K.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.2
    • /
    • pp.123-133
    • /
    • 1990
  • Thermal performance of a solar heating plastic greenhouse designed for a hydroponic system was studied. The system was constructed with the air-water heat exchanger and thermal storage tank that were combined with hydroponic water beds. Experiments were carried out to investigate the daily average heat stored and released in thermal storage tank, average solar energy collection efficiency, average coefficient of performance, average oil reduction factor of thermal storage system, and the heat transfer coefficient during the nighttime in plastic greenhouse. The results obtained in the present study are summarized as follows. 1. Daily average heat stored in thermal storage tank and released from the thermal storage tank was 1,259 and $797KJ/m^2$ day, respectively. 2. The average solar energy collection efficiency of thermal storage tank was 0.125 during the experiment period. And the average coefficient of performance of thermal storage system in plastic greenhouse was 3.6. 3. The average oil reduction factor of thermal storage system and the heat transfer coefficient during the nighttime in plastic greenhouse were found to be 0.52 and $4.3W/m^2\;hr\;^{\circ}C$, respectively.

  • PDF

Classification and function of the Storage System in the Thermal Energy Supply System (축열시스템의 종류 및 열에너지 공급시스템에서의 역할)

  • Lee, Dong-Won;Cho, Soo;Jang, Cheol-Yong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.141-146
    • /
    • 2008
  • For the efficient use of thermal energy and its related equipments, optimal energy in view of quality and quantity should be timely provided. The core of thermal energy storage technology deals with an energy efficiency for effective energy storage and supply. The relative importance of thermal energy storage technology has been underestimated so far, and the specific projects on this filed have been performed intermittently. For the efficient and systematic approach of the energy supply system projects on thermal energy storage technology, we conduct the survey on the current status of this field. Firstly, classify into the thermal energy storage and describing the recent research for each system. The necessity and importance of thermal energy storage technology is identified through this study. It reveals that the thermal energy storage is the mandatory technology to solve the difference of supply and demand in thermal loads. It would greatly contribute to the combined heat and power(CHP) system. The urgent technologies for the commercial value and the core technologies for the CHP system are classified with this study.

  • PDF

An Analysis of the Optimal Thermal Storage Time of Air-Conditioning System with Slab Thermal Storage : An Analysis by the Gradient Method Algorithm (슬래브축열의 최적축열시간 산정 : 구배법 알고리즘에 의한 해석)

  • Jung, Jae-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.702-709
    • /
    • 2008
  • In this paper, the optimal thermal storage time of an air-conditioning system with slab thermal storage in office building was analyzed on the basis of the gradient method algorithm. The sum of room temperature deviation and heat extraction rate was set to the criterion function. It was calculated that four hours is the optimal thermal storage time under the standard evaluation criterion. Furthermore, some case studies were executed by controlling ratio of weight functions of room temperature deviation and heat extraction rate in criterion function. It is possible to design many kinds of optimal operation of an air-conditioning system with slab thermal storage by controlling ratio of the weight functions in criterion function.

A study on Characteristics of Heat Flow of Low Temperature Latent Thermal Storage System (저온 잠열 축열조내의 열유동 특성에 관한 연구)

  • Lee, W.S.;Park, J.W.
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.33-43
    • /
    • 1999
  • The study on ice thermal storage system is to improve total system performance and increase the economical efficiency in actual all-conditioning facilities. To obtain the high charging and discharging efficiencies in ice thermal storage system, the improvement of thermal stratification is essential, therefore the process flow must be piston flow in the cylindrical type. With the relation of the aspect ratio(H/D) in the storage tank, the stratification is formed better as inlet flow rate is smaller. If the inlet and the outlet port are settled at the upside and downside of the storage tank, higher storage rate could be obtainable. In case that the flow directions inside the thermal storage tank are the upward flow in charging and the downward in discharging, thermal stratification is improved because the thermocline thickness is maitained thin and the degree of stratification increases respectively. In the charging process, in case of inlet flow rate the thermal stratification has a tendency to be improved with the lower flow rate and smaller temperature gradient in case of inlet temperature, the large temperature difference between inflowing water and storage water are influenced from the thermal conduction. The effect of the reference temperature difference is seen differently in comparison with the former study for chilled and hot water. In the discharging process, the thermal stratification is improved by the effect of the thermal stratification of the charging process.

  • PDF

Review on Thermal Storage Media for Cavern Thermal Energy Storage (지하공동 열에너지 저장을 위한 축열 매질의 기술 현황 검토)

  • Park, Jung-Wook;Park, Do-Hyun;Choi, Byung-Hee;Han, Kong-Chang
    • Tunnel and Underground Space
    • /
    • v.22 no.4
    • /
    • pp.243-256
    • /
    • 2012
  • Developing efficient and reliable energy storage system is as important as exploring new energy resources. Energy storage system can balance the periodic and quantitative mismatch between energy supply and energy demand and increase the energy efficiency. Industrial waster heat and renewable energy such as solar energy can be stored by the thermal energy storage (TES) system at high and low temperatures. TES system using underground rock carven is considered as an attractive alternative for large-scale storage, because of low thermal conductivity and chemical safety of surrounding rock mass. In this report, the development of available thermal energy storage methods and the characteristics of storage media were introduced. Based on some successful applications of cavern storage and high-temperature storage reported in the literature, the applicabilities and practicabilities of storage media and technologies for large-scale cavern thermal energy storage (CTES) were reviewed.

An Experimental Study on Thermal Storage Performance of an Air Conditioning System with Slab Thermal Storage (슬래브축열 공조시스템의 축열성능에 관한 실험적 연구)

  • Jung Jae-Hoon;Shin Young-Gy
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.427-435
    • /
    • 2005
  • This paper investigates the thermal storage performance of the office building which has adopted an air conditioning system with its slab structure as a regenerator. Four cases of the thermal storage performance experiment were conducted. Room air temperatures, floor slab temperatures, temperatures around the air conditioning unit were logged and analyzed. The load handling capacity of the air conditioning unit and the amount of heat stored in the slab were decided from those experiments. Several efficiencies were investigated to evaluate the performance of the thermal storage. The results concluded that the slab as a regenerator is very effective in cutting down peak loads of the office building.

Consideration of Appropriate Thermal Storage Time of Air-Conditioning System with Slab Thermal Storage in an Office Building by Use of Measurement Value (실측치를 통한 사무소건물 슬래브축열 공조시스템의 적정 축열시간 검토)

  • Jung, Jae-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.10
    • /
    • pp.719-726
    • /
    • 2010
  • In this paper, the appropriate thermal storage time of an air-conditioning system with slab thermal storage was considered by use of summer measurement values. Two standards of heat extraction rate and criterion function were established as the standard that evaluates appropriateness. When heat extraction rate was a standard, zero hour and seven hours were obtained as appropriate thermal storage time, in the case of evaluation by energy consumption and running cost individually. Also, when criterion function was a standard, the difference between energy consumption and running cost was small, it was because the weight function to room air temperature deviation was much bigger than heat extraction rate.

Technologies of Underground Thermal Energy Storage (UTES) and Swedish Case for Hot Water (지하 열에너지 저장 기술 및 스웨덴 암반공동내 열수 저장 사례)

  • Park, Doh-Yun;Kim, Hyung-Mok;Ryu, Dong-Woo;Choi, Byung-Hee;SunWoo, Choon;Han, Kong-Chang
    • Tunnel and Underground Space
    • /
    • v.22 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • Thermal energy storage is defined as the temporary storage of thermal energy at high or low temperatures for later use in need. The energy storage can reduce the time or rate mismatch between energy supply and demand, and thus it plays an important role in conserving energy and improving the efficiency of energy utilization, especially for renewable energy sources which provide energy intermittently. Underground thermal energy storage (UTES) can have additional advantages in energy efficiency thanks to low thermal conductivity and high heat capacity of surrounding rock mass. In this paper, we introduced the technologies of underground thermal energy storage and rock caverns for hot water storage in Sweden.

In-Situ Measurement of Chiller Performance and Thermal Storage Density of an Ice Thermal Storage System (빙축열 시스템 냉동기 성능 및 축열밀도 현장측정 기법연구)

  • Shin Younggy;Yang Hooncheul;Tae Choon-Seob;Cho Soo;Kim Youngil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1204-1209
    • /
    • 2005
  • In-situ measurement was made to evaluate chiller performance and thermal storage density of an ice thermal storage system. The system belonged to a big hotel and the measurement was conducted during late October. Owing to very small cooling load, the data logging was possible for a single thermal storage cycle. However, operation history of the chiller showed a relatively good spectrum of data for performance evaluation. COP and thermal storage density were calculated. The COP at full load was about 4.07, which was lower than $4.8\~6.4$ of new chillers. The measured storage density was about $10.9RT-h/m^3\;(=152MJ/m^3)$, which also was lower than a criterion of normal performance $(above\;13.0RT-h/m^3\;or\;181MJ/m^3)$. The study result provides technical basis for quantitative ESCO business scenario.

An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe (열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향)

  • 최우석;박이동;김철주;황영규
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.69-76
    • /
    • 1995
  • The horizontal thermal storage tank with heat pipe which is suitable for the sensible heat storage system is able to store a hot water from the heat source such as heating pad efficiently and to supply a hot water to load rapidly. Therefore Arrangement of heating pad affects thermal flow and thermal storage efficiency. So, if effective arrangement is decided for condition of constant number of heating pad, the more rapid thermal flow effect and higher thermal storage efficiency is obtainable by active heat transfer. In this experiments, number of heating pad is ranged from three, five and nine, and when number of heating pad is constant, arrangement are two types of concentration-type and dispersion-type. As a result, for the case of concentration-type of heating pad, strong entrainment take place in horizontal thermal storage tank with heat pipe by active heat transfer and in the constant number of heating pad, the concentration-type has the higher efficiency with about 5∼6% than the dispersion-type. Therefore, when heating pad is equipted to horizontal thermal storage tank with heat pipe, concentration-type of heating pad is an efficient design in constant number. of heating pad.

  • PDF