A Study for Improving a Thermal Performance of Liquid Cooled Permanent Magnet Synchronous Machine with Concentrated Winding (집중권 방식 영구자석 동기전동기의 냉각특성 개선에 관한 연구)

  • Kang, Kyong-Ho;Ahn, Su-Hong;Yoon, Young-Duk;Yu, Suk-Jin;Ahn, Hyo-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.555-566
    • /
    • 2012
  • This paper presents a thermal analysis of an interior PM synchronous machine with concentrated winding for electric vehicle. The conventional thermal equivalent network model has been used for a long time for calculation of the temperature rises in electrical machines. In spite of being popular, this method can not be applied correctly for elements with complicated cooling structure like liquid cooled housing. To overcome this drawbacks, in this paper, a hybrid thermal model using the result of CFD analysis partly. Using this method, to improve a thermal performance of PMSM with concentrated winding, the effects of two design parameters are analysed. Finally, the accuracy of this model has been verified by experiments for the developed 21kW motor.

Steady State Thermal Analysis of Brushless Motor for Rack Type Electric Power Steering Using Equivalent Thermal Resistance (등가 열저항을 이용한 R-EPS용 전동기의 정상상태 열해석)

  • Oh, Young-Jin;Ha, Kyung-Ho;Im, Yang-Su;Hong, Jung-Pyo;Jin, Jong-Hak;Jung, Dae-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.84-86
    • /
    • 2001
  • This paper deals with the characteristic and thermal analysis of brushless motors for Rack assist type Electric Power Steering(REPS). The performance of permanent magnet is under the influence of temperature. To predict the motor performance, the thermal analysis is necessary. The equivalent thermal network is composed of the thermal resistance and the temperature of major parts is calculated according to the operating condition.

  • PDF

The Analysis of 3MW Embedded Type PMSG for Wind Turbine (풍력 발전기용 3MW 매립형 영구자석동기발전기 해석)

  • Won, Jeonghyun;Lee, Sangwoo;Kim, D.E.;Chung, Chinwha;Park, H.C.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.180.1-180.1
    • /
    • 2010
  • This paper introduces a 3MW embedded Permanent Magnet Synchronous Generator(PMSG) for wind turbine. The generator features 313mm stator inner radius and 974mm stator length. The blade rotor angular velocity is 15.7 rpm and the gear ratio is set to be 92.93. The nominal generator rpm at rated load is about 1459. The number of poles is six and embedded in the generator rotor. Embedded permanent magnet excitation shows higher reliability, and better efficiency. Using the finite element method, electromagnetic and thermal results are simulated by ANSYS and the results are summarized in this report.

  • PDF

Study on Separating Underwater Earth Field Anomaly Generated by a Ship (함정에 의해 발생하는 수중 지자계 외란신호 분리방법에 대한 연구)

  • Lee, Kang-Jin;Yang, Chang-Seop;Jung, Hyun-Ju;Kim, Dong-Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1412-1417
    • /
    • 2007
  • Magnetic anomaly generated around a ship is mainly due to the permanent magnetization(PM) and induced magnetization (IM) remaining on the hull. It is very difficult to predict the direction and its magnitude of the permanent magnetization distributed over the hull, that is caused by mechanical or thermal stress. In this paper, an effective method is proposed to separate two components, the one produced by PM and the other by IM, from the underwater earth field signal distorted by the ferromagnetic material of the ship. The method can easily provide the two kinds of magnetic anomaly through exploiting experimental results and 3D electromagnetic field analyses even though the PM distribution on the hull is not known. To validate the proposed method, a model ship is manufactured and tested. The results would be of much help to basis research for securing safe navigation of a ship against dangerous factors in underwater.

Design of Preventing Deviation System of Magnet for high Speed Rotated Surface Mounted Permanent Magnet Synchronous Generator (고속으로 회전하는 표면부착형 영구자석 동기발전기의 마그넷 이탈방지 시스템 설계)

  • Kim, Youngmin;Kim, Jungsu;Park, Sunho;Lim, Minsoo;Bang, Johyug;Ryu, Jiyune
    • Journal of Wind Energy
    • /
    • v.5 no.1
    • /
    • pp.50-55
    • /
    • 2014
  • Surface Permanent-Magnetic-Synchronous-Generator (SPMSG) discussed in the present study has operational characteristics such as high rotational speed over 1,000 rpm and centrifugal force of 12 kN·m for each magnet. Structure-development analysis for the minimization of rotor-core weights and the maximization of thermal emission is performed by applying the aluminum-laminated cap which combines the advantages of IPM and SPM in order to overcome the difficulty that attaching the magnet to rotor-core only with an adhesive. In this study, the simulations in terms of structure and electromagnetic were performed with the variable parameters such as shape and thickness of laminated-cap and division method of magnet. As a result, condition for minimized centrifugal force with minimum loss is derived.

Thermal Analysis of IPMSM According to Current Vector Control Method (전류 벡터 제어 방식에 따른 IPMSM의 온도 특성 해석)

  • Kye, Seung-Hyun;Jeong, Tae-Seok;Cho, Gyu-Won;Jang, Ki-Bong;Kim, Gyu-Tak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1420-1425
    • /
    • 2012
  • Nowadays, Interior permanent magnet synchronous motor(IPMSM) which having high power density is much used for the vehicles. However, IPMSM causes a lot of losses because of high-speed driving and high current density, and temperature rising by iron loss and copper loss could reduce torque characteristics and durability of IPMSM. Therefore, analysis about thermal characteristics of IPMSM is required at design stage. In this paper, temperature characteristics according to current vector control method were analyzed through calculate thermal equivalent circuit. And calculated results were verified through comparing with the experiments.

Technology of Air-Conditioning System by Ocean Thermal Energy near Busan Coast (부산지역 해수온도차이용 냉난방기술)

  • Oh, Cheol;Kim, Meong-Whan;Lim, Tae-Woo;Choi, Young-Do
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.350-355
    • /
    • 2009
  • Air-conditioning system by ocean thermal energy has been developed in the areas of Europe, North America and Japan because there are abundant amount of thermal energy potential in the ocean and permanent free use for the thermal energy using the air-conditioning system. In the case of domestic ocean thermal energy resource, ocean thermal energy potential exists about 27,155Tcal/year and totally 20,285Tcal/year of possible thermal energy use by heat pump, which are reported from the survey of the 7 domestic near shore cities. Present study is aimed to survey the current development status of domestic and overseas air-conditioning system by ocean thermal energy, especially, for the air-conditioning facility technologies using sea water.

  • PDF

Thermal Analysis of Water Cooled ISG Based on a Thermal Equivalent Circuit Network

  • Kim, Kyu-Seob;Lee, Byeong-Hwa;Jung, Jae-Woo;Hong, Jung-Pyo
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.893-898
    • /
    • 2014
  • Recently, the interior permanent synchronous motor (IPMSM) has been applied to an integrated starter and generator (ISG) for hybrid electric vehicles. In the design of such a motor, thermal analysis is necessary to maximize the power density because the loss is proportional to the power of a motor. Therefore, a cooling device as a heat sink is required internally. Generally, a cooling system designed with a water jacket structure is widely used for electric motors because it has advantages of simple structure and cooling effectiveness. An effective approach to analyze an electric machine with a water jacket is a thermal equivalent network. This network is composed of thermal resistance, a heat source, and thermal capacitance that consider the conduction, convection, and radiation. In particular, modeling of the cooling channel in a network is challenging owing to the flow of the coolant. In this paper, temperature prediction using a thermal equivalent network is performed in an ISG that has a water cooled system. Then, an experiment is conducted to verify the thermal equivalent network.

Analysis of Eddy Current Loss on Permanent Magnets of Interior Permanent Magnet Synchronous Motor for Railway Transit (철도차량용 매입형 영구자석 동기전동기의 영구자석 와전류 손실 분석 연구)

  • Park, Chan-Bae;Lee, Hyung-Woo;Lee, Byung-Song
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.4
    • /
    • pp.370-375
    • /
    • 2012
  • In order to apply Interior Permanet Magnet Synchronous Motor(IPMSM) to the propulsion system of the railway transit, 110kW class IPMSMs with high-power density are designed as a concentrated winding model and a distributed winding model in this study. The concentrated winding model designed in this study is 6 poles/9 slots and the distributed winding model is 6 poles/36 slots. In general, the eddy current losses in the permanent magnets of IPMSM are caused by the slot harmonics. The thermal demagnetization of the magnet by the eddy current losses at high rotational speed often becomes one of the major problems in the IPMSM with a concentrated windings especially. A design to reduce eddy current losses in permanent magnet design is important in IPMSM for the railway vehicle propulsion system which requires high-speed operation. Therefore, a method to devide the permanent magnet is proposed to reduce the eddy current losses in permanent magnet in this study. Authors analyze the variation characteristics of the eddy current losses generated in permanent magnet of the concentrated winding model by changing the number of the division of the permanent magnets.

Steady-state Thermal Analysis of 5 kW IPMSM Using Thermal Equivalent Circuit (열등가회로를 이용한 5 kW 급 영구자석 동기전동기의 정상상태 열 특성 해석)

  • Kim, Tae Hyun;Yoo, Young Bum;Na, Jong Seung;Ryu, Kyongtae;Moon, Yoon Jae;Lee, Jae Heon;Lee, Ju;Park, Chan Bae;Moon, Seung Jae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.11
    • /
    • pp.951-956
    • /
    • 2014
  • Steady-state thermal analysis was performed on a thermal equivalent circuit to determine the heat generation during operation of an interior permanent magnet synchronous motor (IPMSM). New machines must be compact and light and produce high torque density under extreme environmental conditions. Thermal analysis of an IPMSM is particularly important because excessive heat generated from the core and magnet reduces the IPMSM's output and has adverse effects on the durability. Therefore, steady-state thermal analysis of an IPMSM was performed for changes in the design variables using a thermal equivalent circuit. The changed variables were the axis length and thickness of the housing. The results of this method were compared with those of the finite element method to verify the accuracy and reliability.