• Title/Summary/Keyword: Thermal performance according

Search Result 660, Processing Time 0.029 seconds

Review on the heat storage performance and air pollutant adsorption properties of gypsum board according to the additives (석고보드의 첨가제에 따른 오염물질 흡착 및 축열 성능에 대한 고찰)

  • Seo, Hyun Jeong;Jeong, Su-Gwang;Lim, Jae-Han;Kim, Sumin
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.1
    • /
    • pp.97-106
    • /
    • 2015
  • Gypsum board is easy to manufacture of a variety of forms and has stable mechanical properties and thermal properties. And gypsum boards are widely used to the walls and ceiling of the building as the interior building materials. The studies about technology of applying the various features in the gypsum board with additives are being actively investigated. Development methods for enhancing performance of the gypsum board using additives are largely divided into two categories. The first case is functional gypsum board that is to improve the moisture absorption and moisture-proof properties. Also studies of adsorption and decomposition of indoor air pollutants of the gypsum board using porous materials as an additive are being actively investigated. Another case is applying thermal storage materials which gives the heat storage performance to gypsum board. In this paper, we would like to introduce the various cases of gypsum board applied various additives.

Analysis of Thermal Control Characteristics of VCHP by the Charging Mass of Non-Condensible Gas (불응축가스 주입량에 따른 VCHP의 열제어 특성)

  • Suh Jeong-Se;Park Young-Sik;Chung Kyung-Taek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1139-1144
    • /
    • 2005
  • This study has been performed to investigate the thermal performance of variable conductance heat pipe (VCHP) with meshed wick. The length of condenser portion in a VCHP is varied by the expansion of inert gas with the operation temperature, and the heat transport capacity is thus varied with the operating temperature. In this study, numerical evaluation of the VCHP is made for the thermal performance of VCHP, based on the diffusion model of inert gas. Water is used as a working fluid and nitrogen as a control inert gas in the copper tube. As a result, the thermal performance of VCHP has been compared with that of constant conductance heat pipe (CCHP) according to the variation of operation temperature. Maximum heat transport capacity of VCHP is mainly presented for operation temperature and the variation of operation temperature is also presented for heat transfer rate of VCHP.

Evaluation of Structural Integrity and Cooling Performance of 4250 kVA Power Transformer with ONAN Mode (ONAN 모드 4250kVA 변압기의 구조 건전성과 냉각 성능의 평가)

  • Yang, Chaofan;Kim, Seongik;Cho, Jong-Rae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.7
    • /
    • pp.48-57
    • /
    • 2021
  • The main research content of this paper is to evaluate the structural integrity and the cooling performance of 4250 kVA power transformer with ONAN(Oil Natural and Air Natural) mode. The dynamic analysis is used to verify the structural safety of the transformer by seismic loading. The transformer structure is simplified and NX software is used to build a three-dimensional model, and ANSYS commercial software is used to calculate the stress and deformation by applying corresponding load. The analysis result was evaluated whether it satisfies the design requirements according to the IEEE Std 693 standard. In terms of thermal analysis to evaluate the cooling performance, the thermal physical model is used to calculate the heat exchange between the radiator and the tank in the steady state, and the result is input into the Fluent software to calculate the internal temperature field of the transformer tank, which reduces the calculation cost of thermal fluid. Comparing the simulated hot spot temperature and top oil temperature of the transformer with the calculation results of the IEC60076 classic model, it is found that the error is only 1.9%.

Fireproof Performance Study of ICT Fire Damper by Using Experimentalmethode (실험적 방법에 의한 ICT 파이어 댐퍼의 내화성능연구)

  • Hur, Nam-Soo;Kim, In-Whan;Jang, Sung Cheol;Kim, Jae-Woong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.5
    • /
    • pp.82-89
    • /
    • 2014
  • In this paper, fire resistance test was carried out to obtain class H-120 thermal insulation of fire dampers according to a hydrocarbon fire conditions. Specimens were fabricated three different types according to the change of the insulation system applied to damper blade and coaming which were measured surface temperature by performing the fire resistance test. As a test result, specimen-1, 2 of an uninsulated damper blade were exceeded thermal insulation acceptance criteria at 21 minutes, 46 minutes respectively, but specimen-3 of an insulated damper blade was satisfied thermal insulation acceptance criteria during 120 minutes. The test results showed that the insulation of the damper blade was an important factor in the fireproof performance of fire dampers concerning the coaming length minimum 500 mm on the unexposed side as specified test standard.

Properties of Density and Thermal Conductivity according to Addition ratio of Vermiculite of Lightweight Composite Panel Core (경량복합패널 심재의 버미큘라이트 첨가율에 따른 밀도 및 열전도율 특성)

  • Sin, Jin-Hyun;Kim, Heon-Tae;Kim, Tae-Hyun;Lee, Dong-Hoon;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.111-112
    • /
    • 2016
  • Lately, In case of domestic fire situation, Suffocation due to inflammables has shown higher than direct disaster of the fire among the statistics of death caused by disaster. According to study, Lightweight Hybrid Panel as using the inner or outer wall is made with Polysilicon of the inorganic material, PA and vermiculite, so we make progress to performance experiment and review the density, thermal conductivity properties.

  • PDF

Analysis of Maximum Solar Radiation on Inclined Surfaces for the Installation of Solar Thermal Systems in Korea Using the Optimum Installation Angle (국내 태양열시스템 설치를 위한 시스템 최적 설치각 산출을 통한 최대 경사면일사량 분석)

  • Jo, Dok-Ki;Kang, Young-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.2
    • /
    • pp.47-54
    • /
    • 2009
  • The amount of incident rays over inclination according to direction has been widely utilized as important data m installing solar thermal systems. To optimize the incident solar radiation, the slope, that is the angle between the plane surface in question and the horizontal, and the solar azimuth angles are needed for these solar thermal systems. This is because the performance of the solar thermal systems in much affected by angle and direction of incident rays. Recognizing that factors mentioned above are of importance, actual experiment on the moving route of the sun have been performed in this research to obtain the angle of inclination with which the maximum incident rays can be absorbed. After all, the standard for designing highly optimized solar thermal systems will be provided for designers and employees working in the solar collector related industries.

FE-analysis of Shrink Fits and Internal Clearance for Ball Bearing of Machine Tool (공작기계용 볼 베어링의 억지끼워맞춤과 내부틈새변화에 관한 해석적 연구)

  • Kim, Woong;Lee, Choon-Man;Hwang, Young-Kug
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.5
    • /
    • pp.135-141
    • /
    • 2009
  • The bearing clearance is influenced by shrink fit and thermal expansion during operation. The designer must take into account the reduction of clearance after installation to the interference fits, and thermal expansion must be considered. The purpose of this study is to grasp the internal clearance variation and behavior of a bearing which is a deep connected with fatigue life of bearing and performance of spindle through FEM(Finite Element Method). Finite element analysis is performed by using commercial code ANSYS according to variation of thermal condition and rotational speeds. This paper presents correct negative internal clearance according to temperature during operation. Furthermore, interrelation between thermal expansion and contraction are presented to maintain adequate contact force for three type of spindle system (HSK-A60, HSK-40E, HSK-32E). The influence of the centrifugal force and Internal clearance variation of bearing is studied to operating rotational speed.

Study on the Underground Thermal Environment around Wells for a Design Method of Open-Loop Geothermal System (개방형 지열 시스템 설계법 개발을 위한 관정 주위 지중 온도 환경 검토)

  • Bae, Sangmu;Kim, Hongkyo;Kim, Hyeon-Woo;Nam, Yujin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.1
    • /
    • pp.14-20
    • /
    • 2017
  • Groundwater heat pump (GWHP) system can achieve higher performance of the system by utilizing heat source of the annual constant groundwater temperature. The performance of GWHP system depends on the ground thermal environment such as groundwater temperature, groundwater flow rate and hydraulic conductivity. In this study, the geothermal environment was analyzed by using numerical simulation for develop the two-well geothermal system. As the result, this paper shows the change of the groundwater level and underground temperature around wells according to the conditions of flow rate and hydraulic conductivity.

An Analytical Study on Indoor Thermal Comfort Performance According to the Automatic Control of Internal-External Blind

  • Lee, Do-Hyung;Kim, Tae-Woo;Yoon, Jong-Ho
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.31-38
    • /
    • 2014
  • The purpose of this study is to analyse PMV (Predicted Mean Vote) and PPD (Predicted Percentage of dissatisfied) by automatic control of slat-type vertical blind. EnergyPlus, a building energy analysis software has been used for this study. The energy model is calibrated in Energy Plus using measured zone temperature and glass surface temperature data for one day and thermal comfort performance inside the building analysis was carried out. The calibrated data has the MBE of 4% and Cv(RMSE) of 10%. The result was that, for better zone thermal comfort, installation of blind on the outside is more appropriate than inside or no blind case. Additionally, different glazing types were compared and it was found that Triple Low-e glass is the most favorable.

A Study on the Development of Prototype for Green Roof System in Korea (한국형 Green Roof System 개발을 위한 Proyotype 제안)

  • Kim, Hyen-Soo
    • KIEAE Journal
    • /
    • v.3 no.3
    • /
    • pp.3-11
    • /
    • 2003
  • The purpose of this study is to develope an available outdoor insulation construction for the green roof system in Korea. On its own economical and structural problems of constructional risk, the typical outdoor insulation construction on the korean spot does not function efficiently with the green roof. Therefore, this study consists of four main contents as follows: 1. The objectives of the study are established by analysing the problems of the typical in- and outdoor roof insulation system in korea. 2. The foreign outdoor insulation systems for the green roof are clarified to find out an acceptable prototype for Korea. 3. According to loadtest, the prototype, which has a waterproof on the thermal insulation, is tested to demonstrate the structural safety. 4. The U-value test of the prototype on KS F 2277 brings the thermal performance of the green roof system, which can influence the thickness of the insulation.