• 제목/요약/키워드: Thermal performance according

검색결과 660건 처리시간 0.03초

주거 공간에서의 룸 에어컨디셔너 실내기 유형에 따른 온열쾌적성 및 에너지성능 평가 (Evaluation of Thermal Comfort and Energy Efficiency According to Indoor-Unit Types of Room Air-Conditioner in Housing Space)

  • 석호태;김동우;양정훈
    • 한국주거학회논문집
    • /
    • 제20권4호
    • /
    • pp.19-29
    • /
    • 2009
  • The purpose of this study is to evaluate the air diffusion performance of a range of indoor units for room airconditioners; the wall-mounted type, floor-standing type, and ceiling-mounted type. These types of units, which have been widely used in housing spaces, will be studied with respect to thermal comfort and the energy performance using CFD analysis. In this study, current air conditioning status and related problems in housing spaces are examined, and a CFD analysis is performed in order to compare and analyze the thermal comfort and energy efficiency across each type of indoor-unit using the PMV, ADPI, EUC and FCEI indexes. The analysis results collectively considering thermal comfort and energy performance indicated that the ceiling-mounted type 4-way indoor unit showed the best diffusion performance in terms of thermal comfort, and had the second best diffusion performance in terms of energy performance after the wall-mounted type under certain conditions.

실험에 의한 공기식 PVT 컬렉터의 열·전기 성능에 관한 연구 (An Experimental Study on Thermal and Electrical Performance of an Air-type PVT Collector)

  • 김상명;김진희;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제39권2호
    • /
    • pp.23-32
    • /
    • 2019
  • PVT (Photovoltaic/thermal) system is technology that combines PV and solar thermal collector to produce and use both solar heat and electricity. PVT has the advantage that the energy production per unit area is higher than any single use of PV or solar thermal energy systems because it can produce and use heat and electricity simultaneously. Air-type PVT collectors use air as the heat transfer medium, and the air flow rate and flow pattern are important factors affecting the performance of the PVT collector. In this study, a new air-type PVT collector with improved thermal performance was designed and manufactured. And then thermal and electrical performance and characteristics of air-type PVT collector were analyzed through experiments. For the thermal performance analysis of the PVT collector, the experiment was conducted under the test conditions of ISO 9806:2017 and the electrical performance was analyzed under the same conditions. As a result, the thermal efficiency increased to 26~45% as the inlet flow rate of PVT collector increased from $60{\sim}200m^3/h$. Also, it was confirmed that the air-type PVT collector prevents the PV surface temperature rise according to the operating conditions.

잔류 열 변형을 고려한 평판형 압전 복합재료 유니모프 작동기의 해석 (Analysis of a Plate-type Piezoelectric Composite Unimorph Actuator Considering Thermal Residual Deformation)

  • 구남서;우성충
    • 대한기계학회논문집A
    • /
    • 제30권4호
    • /
    • pp.409-419
    • /
    • 2006
  • The actuating performance of plate-type unimorph piezoelectric composite actuators having various stacking sequences was evaluated by three dimensional finite element analysis on the basis of thermal analogy model. Thermal residual stress distribution at each layer in an asymmetrically laminated plate with PZT ceramic layer and thermally induced dome height were predicted using classical laminated plate theory. Thermal analogy model was applied to a bimorph cantilever beam and LIPCA-C2 actuator in order to confirm its validity. Finite element analysis considering thermal residual deformation showed that the bending behavior of piezoelectric composite actuator subjected to electric loads was significantly different according to the stacking sequence, thickness of constituent PZT ceramic and boundary conditions. In particular, the increase of thickness of PZT ceramic led to the increase of the bending stiffness of piezoelectric composite actuator but it did not always lead to the decrease of actuation distance according to the stacking sequences of piezoelectric composite actuator. Therefore, it is noted that the actuating performance of unimorph piezoelectric composite actuator is rather affected by bending stiffness than actuation distance.

가속화 시험을 통한 페놀폼 단열재의 장기성능 비교분석에 관한 연구 (Study on Long-term Performance of Phenolic Foam Insulation through Accelerated Aging Test)

  • 김진희;김상명;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제40권2호
    • /
    • pp.11-23
    • /
    • 2020
  • The application of the high-performance insulation materials for buildings seems to be an essential measure for reducing energy use in buildings. Phenolic foam is a readily available insulation material with thermal conductivity of about 0.018 to 0.020 W/(mK). It has the advantage of higher thermal resistance and better fire resistance compared to other conventional building insulation materials. Insulation material used for building envelope is regarded as one of the decisive factors for building's energy load. Furthermore, the degradation of its thermal performance over time increasingly affects the building's energy use demand. Generally, the life span of conventionally built buildings is expected to be more than 50 years, so the long-term performance of insulation materials is critical. This paper aims to evaluate the long-term performance of phenolic form boards through an accelerated aging test. The tests were conducted according to BS EN 13166 and KS M ISO 11561. Based on the results of the accelerated aging test, the thermal performance variation of the material was analyzed, and then its aged value after 25 years was computed. Also, the characteristics of the phenolic foam board's long-term performance were also examined based on the standard testing methods adopted.

더블로이유리 적용 창호의 구성요소에 따른 단열성능 비교 실험 (A Comparison of Thermal Performance of Double Low-E Glazing Window according to Various Material)

  • 장철용;안병립;김치훈;김준섭;이성재
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.133-137
    • /
    • 2011
  • Low-e glazing is classified as soft low-e glazing and hard low-e glazing. Hard low-e glazing can be temperable and its handling is comfortable because its coating film is a oxide film generated at high temperatures. But there is a fatal weakness that its insulation performance and shielding performance are lower compared to soft low-e glazing by low electrical conductivity of coating film. Soft low-e glazing is excellent because its coating film consists of Ag that is excellent electrical conductivity and it has strength that can supply various product consumers want. But soft low-e glazing has weaknesses that temperable and handling are difficult because Ag is oxidized easily. Therefore this study analyzes thermal performance of glazing by changing filling gas according to applying low-e glazing through simulation to judge performance before making sample. After this process, a comparative experimental study was done through TVS by making temperable low-e glazing.

  • PDF

잠열 축열식 칠러시스템의 제어 방식에 따른 성능 분석 (A Performance Analysis on a Chiller with Latent Thermal Storage According to Various Control Methods)

  • 강병하;김동준;이충섭;장영수
    • 설비공학논문집
    • /
    • 제29권11호
    • /
    • pp.592-604
    • /
    • 2017
  • A chiller, having a thermal storage system, can contribute to load-leveling and can reduce the cost of electricity by using electricity at night. In this study, the control experiments and simulations are conducted using both conventional and advanced methods for the building cooling system. Advanced approaches, such as the "region control method", divide the control region into five zones according to the size of the building load, and determines the cooling capacities of the chiller and thermal storage. On the other hand, the "dynamic programming method" obtains the optimal cooling capacities of the chiller and thermal storage by selecting the minimum-cost path by carrying out repetitive calculations. The "thermal storage priority method" shows an inferior chiller performance owing to the low-part load operation, whereas the chiller priority method leads to a high electric cost owing to the low utilization of thermal storage and electricity at night. It has been proven that the advanced control methods have advantages over the conventional methods in terms of electricity consumption, as well as cost-effectiveness. According to the simulation results during the winter season, the electric cost when using the dynamic programming method was 6.5% and 8.9% lower than that of the chiller priority and the thermal storage priority methods, respectively. It is therefore concluded that the cost of electricity utilizing the region control method is comparable to that of the dynamic programming method.

지중열교환기 성능 향상에 관한 연구 (A Study on Improving the Efficiency of Ground Heat Exchanger)

  • 김욱중;이공훈;김민수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.3142-3147
    • /
    • 2008
  • A simple transient simulation of ground source heat pump system was carried out to investigate the effects of ground thermal conductivity on its performance. The TRNSYS code with a simple water to water heat pump model was used to compare the COP variation of the system. A new ground heat exchanger called by semi-closed loop was proposed and constructed in the real site. The effective thermal conductivity was measured using the test equipment developed by according to the line source model. The simulation results showed that highly efficient thermal conductivity of the grout material could increase the performance of the heat pump system very well. And the new ground heat exchanger showed the increased effective thermal conductivity as the penetration water flow rate(PWFR) was increased. Therefore, the performance improvement of the heat pump system using the proposed ground heat exchanger can be expected.

  • PDF

중공사막 진공 막증류 모듈의 하우징 누수가 담수 생산에 미치는 영향 분석 (Analysis of Effect on Freshwater Production of Vacuum Membrane Distillation Module according to Housing Leak)

  • 주홍진;곽희열
    • 상하수도학회지
    • /
    • 제30권3호
    • /
    • pp.313-319
    • /
    • 2016
  • In this study, the performance experiment was conducted to compare the permeate flux of hollow fiber Vacuum Membrane Distillation module according to leak problem between module housing and membrane bundle. For the permeate flux performance experiment of the two Vacuum Membrane Distillation modules, the Lab-scale experimental equipment was built in the capacity of $1m^3/day$. The performance test of the two Vacuum Membrane Distillation modules were analyzed according to the feed water conditions. As a result, it was analyzed that the leak VMD module decreased about 14% of permeate flux than normal VMD module.

자동차 배기성능개선을 위한 확장형 공동파이프에 관한 연구 (A Study on the Expansion Cavity Pipe for Performance Improvement of Exhaust System in Automotive)

  • 손성만;박경석
    • 한국자동차공학회논문집
    • /
    • 제17권5호
    • /
    • pp.1-6
    • /
    • 2009
  • The temperature of exhaust gas was raised by increasing of engine movement on developing engine. Thermal of high temperature and pressure reverse in bellows, because of increasing of engine movement and the thermal performance of converter in combustion. As a result, thermal loss is increased and thermal efficiency is decreased rapidly in bellows, it can occur to damage in mechanical structure. In this study, it was necessary to analyze back pressure performance and thermal characteristic on driving condition in exhaust system. It was adapted braid type bellows and straight type exhaust pipe. It was compared with curve type exhaust pipe for lay-out on considering to design of exhaust system. It was necessary to improve thermal characteristic and back pressure performance so that expansion cavity pipe(ECP) was installed between bellows and catalyst convert. Not only decreasing back pressure was solved but also thermal characteristic problems in exhaust pipe because of increasing capacity. According to this study, the basis of data is presented when new exhaust system is designed.

PCM 혼입량이 시멘트 모르타르의 열전도율에 미치는 영향에 관한 실험적 연구 (PCM mixed the amount of Thermal Conductivity of Cement mortar Experimental Study on the effect.)

  • 정유건;김보현;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.245-246
    • /
    • 2011
  • In recent research in this emerging and latent heat storage material features an innovative temperature - controlled Phase Change Materials to evaluate the superior thermal performance would like to calculate the thermal conductivity. Specified in KS F 4040 test specimen dimensions were equivalent in specifications, test methods according to KS L 9016 was an experiment in progress. As a result, the thermal conductivity of plain cement mortar mixed with more PCM came out with low thermal conductivity of mortar, thermal performance was excellent.

  • PDF