• Title/Summary/Keyword: Thermal modeling

Search Result 972, Processing Time 0.029 seconds

Flow analysis of the Sump Pump (흡수정의 유동해석)

  • Jung, Han-Byul;Noh, Seung-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.673-680
    • /
    • 2017
  • sump pump is a system that draws in water that is stored in a dam or reservoir. They are used to pump large amounts of water for cooling systems in large power plants, such as thermal and nuclear plants. However, if the flow and sump pump ratio are small, the flow rate increases around the inlet port. This causes a turbulent vortex or swirl flows. The turbulent flow reduces the performance and can cause failure. Various methods have been devised to solve the problem, but a correct solution has not been found for low water level. The most efficient solution is to install an anti-vortex device (AVD) or increase the length of the sump inlet, which makes the flow uniform. This paper presents a computational fluid dynamics (CFD) analysis of the flow characteristics in a sump pump for different sump inlet lengths and AVD types. Modeling was performed in three stages based on the pump intake, sump, and pump. For accurate analysis, the grid was made denser in the intake part, and the grid for the sump pump and AVD were also dense. 1.2-1.5 million grid elements were generated using ANSYS ICEM-CFD 14.5 with a mixture of tetra and prism elements. The analysis was done using the SST turbulence model of ANSYS CFX14.5, a commercial CFD program. The conditions were as follows: H.W.L 6.0 m, L.W.L 3.5, Qmax 4.000 kg/s, Qavg 3.500 kg/s Qmin 2.500 kg/s. The results of analysis by the vertex angle and velocity distribution are as follows. A sump pump with an Ext E-type AVD was accepted at a high water level. However, further studies are needed for a low water level using the Ext E-type AVD as a base.

Assessment of Surface Boundary Conditions for Predicting Ground Temperature Distribution (지중온도 변화 예측을 위한 지표면 경계조건 검토)

  • Jang, Changkyu;Choi, Changho;Lee, Chulho;Lee, Jangguen
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.8
    • /
    • pp.75-84
    • /
    • 2013
  • Soil freezing is a phenomenon arising due to temperature difference between atmosphere and ground, and physical properties of soils vary upon the phase change of soil void from liquid to solid (ice). A heat-transfer mechanism for this case can be explained by the conduction in soil layers and the convection on ground surface. Accordingly, the evaluation of proper thermal properties of soils and the convective condition of ground surface is an important task for understanding freezing phenomenon. To describe convection on ground surface, simplified coefficient methods can be applied to deal with various conditions, such as atmospheric temperature, surface vegetation conditions, and soil constituents. In this study, two methods such as n-factor and convection coefficient for the convective ground surface boundary were applied within a commercial numerical program (TEMP/W) for modeling soil freezing phenomenon. Furthermore, the numerical results were compared to laboratory testing results. In the series of the comparison results, the convection coefficient is more appropriate than n-factor method to model the convective boundary condition.

Enhancement of the Chaperone Activity of Alkyl Hydroperoxide Reductase C from Pseudomonas aeruginosa PAO1 Resulting from a Point-Specific Mutation Confers Heat Tolerance in Escherichia coli

  • Lee, Jae Taek;Lee, Seung Sik;Mondal, Suvendu;Tripathi, Bhumi Nath;Kim, Siu;Lee, Keun Woo;Hong, Sung Hyun;Bai, Hyoung-Woo;Cho, Jae-Young;Chung, Byung Yeoup
    • Molecules and Cells
    • /
    • v.39 no.8
    • /
    • pp.594-602
    • /
    • 2016
  • Alkyl hydroperoxide reductase subunit C from Pseudomonas aeruginosa PAO1 (PaAhpC) is a member of the 2-Cys peroxiredoxin family. Here, we examined the peroxidase and molecular chaperone functions of PaAhpC using a site-directed mutagenesis approach by substitution of Ser and Thr residues with Cys at positions 78 and 105 located between two catalytic cysteines. Substitution of Ser with Cys at position 78 enhanced the chaperone activity of the mutant (S78C-PaAhpC) by approximately 9-fold compared with that of the wild-type protein (WT-PaAhpC). This increased activity may have been associated with the proportionate increase in the high-molecular-weight (HMW) fraction and enhanced hydrophobicity of S78C-PaAhpC. Homology modeling revealed that mutation of $Ser^{78}$ to $Cys^{78}$ resulted in a more compact decameric structure than that observed in WT-PaAhpC and decreased the atomic distance between the two neighboring sulfur atoms of $Cys^{78}$ in the dimer-dimer interface of S78C-PaAhpC, which could be responsible for the enhanced hydrophobic interaction at the dimer-dimer interface. Furthermore, complementation assays showed that S78C-PaAhpC exhibited greatly improved the heat tolerance, resulting in enhanced1 survival under thermal stress. Thus, addition of Cys at position 78 in PaAhpC modulated the functional shifting of this protein from a peroxidase to a chaperone.

Macroscopic High-Temperature Structural Analysis Model for a Small-Scale PCHE Prototype (I) (소형 PCHE 에 대한 거시적 고온 구조 해석 모델링 (I))

  • Song, Kee-Nam;Lee, Heong-Yeon;Kim, Chan-Soo;Hong, Sung-Duk;Park, Hong-Yoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.11
    • /
    • pp.1499-1506
    • /
    • 2011
  • The IHX (intermediate heat exchanger) is a key component of nuclear hydrogen systems for the production of massive amounts hydrogen. The IHX transfers the $950^{\circ}C$ heat generated by the VHTR (very high temperature reactor) to a hydrogen production plant. The Korea Atomic Energy Research Institute established a small-scale gas loop to test the performance of key VHTR components and manufactured a small-scale PCHE (printed circuit heat exchanger) prototype, which is being considered as a candidate for the IHX, for testing in the small-scale gas loop. In this study, as a part of the high-temperature structural integrity evaluation of the small-scale PCHE prototype, we carried out high-temperature structural analysis modeling and macroscopic thermal and structural analysis for the small-scale PCHE prototype under the small-scale gas loop test conditions. This analysis serves as a precedent study to scheduled PCHE performance test in the small-scale gas loop. The results obtained in this study will be compared with the test results for the small-scale PCHE and then used to design the medium-scale PCHE prototype.

Study on Applicability of Passive Infrared Thermography Analysis for Blistering Detection of Stone Cultural Heritage (석조문화유산의 박리검출을 위한 수동적 적외선 열화상분석의 적용성 연구)

  • Jo, Young Hoon;Lee, Chan Hee;Yoo, Ji Hyun
    • Journal of Conservation Science
    • /
    • v.29 no.1
    • /
    • pp.55-67
    • /
    • 2013
  • This study focused on analysis condition and application method of the passive infrared thermography according to the direction and time to nondestructively detect the blistering zone of stone cultural heritage. As a result, the passive thermographic images showed different temperature characteristics by time because it sensitively reacts to air temperature, insolation and sunshine direction. In particular, the insolation and sunshine direction, which are periodically changed from 6:00 to 17:00, irregularly made surface temperature. In addition, surface temperature differences were brought on fresh zones and blistering zones except specific time since blistering causes erratic thermal transfer. As a result of examining the detection characteristics of blistering by time, the blistering was well detected between 9:00 and 10:00 when there was rapid increase in air temperature and insolation in all direction except the north. However, this study isn't considered effects of four seasons because it is carried out in autumn, and the passive thermography has difficulty to analyze the quantitative area of blistering zone. Therefore, an additional study for synthetic consideration of the passive thermography analysis about four seasons and quantitative modeling of blistering zone using the active thermography are needed.

An Analysis of the Factors Affecting User Satisfaction in Computational Science and Engineering Platforms: A Case Study of EDISON (계산과학공학플랫폼 품질 특성이 사용자 만족도에 영향을 미치는 요인에 관한 연구)

  • On, Noori;Kim, Nam-Gyu;Ru, Kimyoung;Jang, Hanbichnale;Lee, Jongsuk Ruth
    • Journal of Internet Computing and Services
    • /
    • v.20 no.6
    • /
    • pp.85-93
    • /
    • 2019
  • Computational Science and Engineering is a convergence study that understands and solves complex problems such as science, engineering, and social phenomena through modeling using computing resources. Computational science and engineering combines algorithms, computational and informatics, and infrastructure. The importance of computational science is increasing with the improvement of computer performance and the development of large data processing technology. In Korea, Korea Institute of Science and Technology Information (KISTI) has been developing national computational science engineering software and utilization technology by combining basic science and computing technology through EDISON project. The EDISON project builds an open EDISON platform and integrates and services information systems in seven areas of computational science and engineering (computational thermal fluids, nanophysics, computational chemistry, structural dynamics, computational design, and computational medicine). Using this, we have established a web-based curriculum to lay the groundwork for fostering scientific talent and commercializing computational science and engineering software. The purpose of this study is to derive the quality characteristic factors of computational science platform and to empirically examine the effect on user satisfaction. This paper examines how the quality characteristics of information systems, the computational science engineering platform, affect the user satisfaction by modifying the research questions according to the propensity of the computational science platform by referring to the success factors of DeLone and McLean's information system. Based on the results of this study, we will suggest strategic implications for platform improvement by searching the priority of quality characteristics of computational science platform.

Modeling Temperature-Dependent Development and Hatch of Overwintered Eggs of Pseudococcus comstodki (Homoptera:Pseudococcidae) (가루깍지벌레(Pseudococcus comstocki (Kuwana))월동알의 온도발육 및 부화시기예찰모형)

  • Jeon, Heung-Yong;Kim, Dong-Soon;Yiem, Myoung-Soon;Lee, Joon-Ho
    • Korean journal of applied entomology
    • /
    • v.35 no.2
    • /
    • pp.119-125
    • /
    • 1996
  • Temperature-dependent development study for overwintered eggs of Pseudococcus comstocki (Kuwana) wasconducted to develop a forecasting model for egg hatch date. Hatch times of overwintered eggs were comparedat five constant temperatures (10, 15, 20, 25, 27$^{\circ}$C) and different collection dates. A nonlinear, four-parameterdevelopmental model with high temperature inhibition accurately described (R2=0.9948) mean developmentalrates of all temperatures. Variation in developmental times was modeled(~~=0.972w9)it h a cumulative Weibullfunction. Least-squares linear regression (rate=O.O06358[Temp.]-0.07566)d escribed development in the linearregion (15-25$^{\circ}$C) of the development curve. The low development threshold temperature was estimated 11.9"Cand 154.14 degree-days were required for complete development. The linear degree-day model (thermal summation)and rate summation model (Wagner et al. 1985) were validated using field phenology data. In degreedaymodels, mean-minus-base method, sine wave method, and rectangle method were used in estimation of dailythermal units. Mean-minus-base method was 18 to 28d late, sine wave method was 11 to 14d late, rectanglemethod was 3 to 5d late, and rate summation model was 2 to 3d late in predicting 50% hatch of overwinteredeggs. hatch of overwintered eggs.

  • PDF

A Study on Variations of the Low Cycle Fatigue Life of a High Pressure Turbine Nozzle Caused by Inlet Temperature Profiles and Installation Conditions (고압터빈 노즐에서 입구온도분포와 장착조건에 따른 저주기 피로 수명 영향에 대한 연구)

  • Huh, Jae Sung;Kang, Young Seok;Rhee, Dong Ho;Seo, Do Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.11
    • /
    • pp.1145-1151
    • /
    • 2015
  • High pressure components of a gas turbine engine must operate for a long life under severe conditions in order to maximize the performance and minimize the maintenance cost. Enhanced cooling design, thermal barrier coating techniques, and nickel-base superalloys have been applied for overcoming them and furthermore, material modeling, finite element analysis, statistical techniques, and etc. in design stage have been utilized widely. This article aims to evaluate the effects on the low cycle fatigue life of the high pressure turbine nozzle caused by different turbine inlet temperature profiles and installation conditions and to investigate the most favorable operating condition to the turbine nozzle. To achieve it, the structural analysis, which utilized the results of conjugate heat transfer analysis as loading boundary conditions, was performed and its results were the input for the assessment of low cycle fatigue life at several critical zones.

Geomechanical Stability of Underground Lined Rock Caverns (LRC) for Compressed Air Energy Storage (CAES) using Coupled Thermal-Hydraulic-Mechanical Analysis (열-수리-역학적 연계해석을 이용한 복공식 지하 압축공기에너지 저장공동의 역학적 안정성 평가)

  • Kim, Hyung-Mok;Rutqvist, Jonny;Ryu, Dong-Woo;Synn, Joong-Ho;Song, Won-Kyong
    • Tunnel and Underground Space
    • /
    • v.21 no.5
    • /
    • pp.394-405
    • /
    • 2011
  • In this paper, we applied coupled non-isothermal, multiphase fluid flow and geomechanical numerical modeling using TOUGH-FLAC coupled analysis to study the complex thermodynamic and geomechanical performance of underground lined rock caverns (LRC) for compressed air energy storage (CAES). Mechanical stress in concrete linings as well as pressure and temperature within a storage cavern were examined during initial and long-term operation of the storage cavern for CAES. Our geomechanical analysis showed that effective stresses could decrease due to air penetration pressure, and tangential tensile stress could develop in the linings as a result of the air pressure exerted on the inner surface of the lining, which would result in tensile fracturing. According to the simulation in which the tensile tangential stresses resulted in radial cracks, increment of linings' permeability and air leakage though the linings, tensile fracturing occurred at the top and at the side wall of the cavern, and the permeability could increase to $5.0{\times}10^{-13}m^2$ from initially prescribed $10{\times}10^{-20}m^2$. However, this air leakage was minor (about 0.02% of the daily air injection rate) and did not significantly impact the overall storage pressure that was kept constant thanks to sufficiently air tight surrounding rocks, which supports the validity of the concrete-lined underground caverns for CAES.

Study of a Recurring Anticyclonic Eddy off Wonsan Coast in Northern Korea Using Satellite Tracking Drifter, Satellite Ocean Color and Sea Surface Temperature Imagery (위성원격탐사를 이용한 동해 원산연안의 재발생 와동류 연구)

  • 서영상;장이현;김정희
    • Korean Journal of Remote Sensing
    • /
    • v.16 no.3
    • /
    • pp.211-220
    • /
    • 2000
  • Even though recurring eddies at the terminal end of the East Korean Warm Current have been identified in the thermal infrared imagery from the NOAA/AVHRR sensor and ocean color data from Orbview-2/SeaWiFS sensor, it is difficult to make observation in the field regarding recurring eddies located around the Wonsan coastal area in North Korea. But we could get in situ data related to an eddy from an ARGOS satellite tracking drifter trapped in the eddy on January 4th, 1999. An ARGOS drifter, a NOAA satellite tracked buoy was trapped by the eddy during January 4th.March 18, 1999. The ARGOS drifter rotated 10 times per 72 days on the edge of the eddy located at $39^{\circ}N$, $129^{\circ}E$. The diameter of the eddy was about 100 km. The horizontal rotation velocity of the recurring cold-core anti-cyclonic eddy was 1.53 km/h(42 cm/sec). The sea surface temperatures of the eddy varied from $14.7^{\circ}C$ on January 5, 1999 to $9.6^{\circ}C$ on March 18,1999. To study the mechanism of the recurring eddy. we tried to find out the relationship between the vector of the drifter moving in the eddy and the wind vector in Sokcho and Ulleung Island located near the eddy in southern Korea, and the difference in sea level between Ulleung Island and Mukho. We hope the results of this study would be useful for calibration and validation data of simulation and numerical modeling studies of the recurring eddy.