• Title/Summary/Keyword: Thermal interference

Search Result 152, Processing Time 0.024 seconds

Measurements of Inner Defects of the Plate using Dual-beam Shearography (Dual-Beam Shearography를 이용한 물체의 내부결함 측정)

  • Ham, Hyo-Shick;Choi, Sung-Eul
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.239-247
    • /
    • 2005
  • In this study, we have used newly developed dual-beam shearography which is based on laser speckle that includes various information about an object. Among the several shearing techniques, we used Michelson shearing interference technique which is the most powerful. Acrylate plate was used as a sample, which has inner defects and low thermal conductivity. Michelson shearing interferometer was used for obtaining speckle fringes. We also used phase shifting technique to get a phase map. Using single beam illumination, we could obtain mixture of deformation components of both in-plane and out-of-plane. In order to separate the two components, we have used dual-beam shearography technique. We have obtained a speckle pattern of both before and after deformation. Through LS filtering and unwrapping processes, we could find a position and a shape of the inner defects easily. Deformation of the acrylate plate due to thermal heating has occurred mainly in z-direction(out-of-plane) because it has low thermal conductivity. The acrylate plate was deformed only at the restricted area where the electrical heat applied.

Design and Reliability Evaluation of 5-V output AC-DC Power Supply Module for Electronic Home Appliances (가전기기용 직류전원 모듈 설계 및 신뢰성 특성 해석)

  • Mo, Young-Sea;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.504-510
    • /
    • 2017
  • This paper presents an AC-DC power module design and evaluates its efficiency and reliability when used for electronics appliances. This power module consists of a PWM control IC, power MOSFETs, a transformer and several passive devices. The module was tested at an input voltage of 220V (RMS) (frequency 60 Hz). A test was conducted in order to evaluate the operation and power efficiency of the module, as well as the reliability of its protection functions, such as its over-current protection (OVP), overvoltage protection (OVP) and electromagnetic interference (EMI) properties. Especially, we evaluated the thermal shut-down protection (TSP) function in order to assure the operation of the module under high temperature conditions. The efficiency and reliability measurement results showed that at an output voltage of 5 V, the module had a ripple voltage of 200 mV, power efficiency of 73 % and maximum temperature of $80^{\circ}C$ and it had the ability to withstand a stimulus of high input voltage of 4.2 kV during 60 seconds.

Temperature Control of Injection Molding Machine using PI Controller with Input Restriction (PI 제어기의 입력제한을 이용한 사출 성형기 온도제어)

  • Jang, Yu-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.604-610
    • /
    • 2007
  • Injection molding is the most common method of shaping plastic resins for manufacturing a variety of parts. This injection molding is accomplished by injection molding machines (IMM) which consists of a hewer, a reciprocating screw, barrel assembly, and an injection nozzle. The plastic resin is fed to the machine through the hopper and it should be heated to the target melting temperature, which depends on material properties, as closely as possible with very small temperature overshoot in the barrel. Since the barrel, which has temperature dependent specific heat and thermal conductivity in the operating temperature range, is heated by the several electric heater bands, it is not an easy task to control the temperature of the barrel owing to the interference of neighboring heaters and its material properties. Though PID controller with auto-tuning capability is widely adopted in the nm, the auto-tuning process should be carried out whenever the operating temperature is changed significantly. Recently, though the predictive controller is developed and shows good performance, it has drawbacks: 1. Since the heat transfer modeling process is very complicated and should be carried out again when the barrel is changed, it is somewhat inappropriate in the field. 2. The controller performance is not validated in whole operating temperature range. In this paper, cascade type simple PI controller with input restriction is proposed to find the possibility of controlling the barrel temperature in the whole operating temperature range. It is shown by experiment that the proposed controller shows good performance. This result can be applied to design of PI controller with auto-tuning capability.

Determination of Captan, Folpet, Captafol and Chlorothalonil Residues in Agricultural Commodities using GC-ECD/MS (GC-ECD/MS를 이용한 농산물 중 Captan, Folpet, Captafol 및 Chlorothalonil의 잔류분석법)

  • Lee, Su-Jin;Hwang, Young-Sun;Kim, Young-Hak;Kwon, Chan-Hyeok;Do, Jung-A;Im, Moo-Hyeog;Lee, Young-Deuk;Choung, Myoung-Gun
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.2
    • /
    • pp.165-175
    • /
    • 2010
  • A gas chromatographic (GC) method was developed to determine residues of captan, folpet, captafol, and chlorothalonil, known as broad-spectrum protective fungicides for the official purpose. All the fungicide residues were extracted with acetone containing 3% phosphoric acid from representative samples of five agricultural products which comprised rice, soybean, apple, pepper, and cabbage. The extract was diluted with saline, and dichloromethane partition was followed to recover the fungicides from the aqueous phase. Florisil column chromatography was additionally employed for final cleanup of the extracts. The analytes were then determined by gas chromatography using a DB-1 capillary column with electron capture detection. Reproducibility in quantitation was largely enhanced by minimization of adsorption or thermal degradation of analytes during GLC analysis. Mean recoveries generated from each crop sample fortified at two levels in triplicate ranged from 89.0~113.7%. Relative standard deviations (RSD) were all less than 10%, irrespective sample types and fortification levels. As no interference was found in any samples, limit of quantitation (LOQ) was estimated to be 0.008 mg/kg for the analytes except showing higher sensitivity of 0.002 mg/kg for chlorothalonil. GC/Mass spectrometric method using selected-ion monitoring technique was also provided to confirm the suspected residues. The proposed method was reproducible and sensitive enough to determine the residues of captan, folpet, captafol, and chlorothalonil in agricultural commodities for routine analysis.

Formation and Chemical Leaching of a Non-Equilibrium Al(Fe-Cu) Alloy Powder produced by Rod-Milling (Rod Milling에 의해 제작된 비평형 Al(Fe-Cu) 합금 분말의 형성 및 Chemical Leaching)

  • 김현구;명화남
    • Journal of Powder Materials
    • /
    • v.9 no.5
    • /
    • pp.359-364
    • /
    • 2002
  • We report the structure, thermal and magnetic properties of a non-equilibrium $Al_{0.6}(Fe_{50}Cu_{50})_{0.4}$ alloy powder produced by rod milling and chemical leaching. An X-ray diffractometry(XRD), a transmission electron microscope(TEM), a differential scanning calorimeter(DSC), a vibrating sample magnetometer(VSM), and superconducting quantum interference device(SQUID) were utilized to characterize the as-milled and leaching specimens. The crystallite size reached a value of about 8.82 nm. In the DSC experiment, the peak temperatures and crystallization temperatures decreased with increasing milling time. The activation energy of crystallization is 200.5 kJ/mole for as-milled alloy powder. The intensities of the XRD peaks of as-milled powders associated with the bcc type $Al_{0.5}Fe_{0.5}$ structure formative at $350^{\circ}C$ sharply increase with increasing annealing temperature. Above $400^{\circ}C$, peaks alloted to $Al_{0.5}Fe_{0.5}$ and $Al_{5}Fe_{2}$ are observed. After annealing at $600^{\circ}C$ for 1h, the leached Ll specimen transformed into bcc $\alpha$-Fe and fcc Cu phases, accompanied by a change in the structural and magnetic properties. The saturation magnetization decreased with increasing milling time, and a value of about 8.42 emu/g was reached at 500 h of milling. The coercivity reached a maximum value of about 142.7 Oe after 500 h of milling. The magnetization of leached specimens as function of fields were higher at 5 K, and increased more sharply at 5 K than at 100 K.

Evolution of Magnetic Property in Ultra Thin NiFe Films (나노두께 퍼말로이에서의 계면효과에 의한 자기적 물성 변화)

  • Jung, Young-soon;Song, Oh-sung
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.5
    • /
    • pp.163-168
    • /
    • 2004
  • We prepared ultra thin film structure of Si(100)/ $SiO_2$(200 nm)/Ta(5 nm)/Ni$_{80}$Fe$_{20/(l~15 nm)}$Ta(5 nm) using an inductively coupled plasma(ICP) helicon sputter. Magnetic properties and cross-sectional microstructures were investigated with a superconduction quantum interference device(SQUID) and a transmission electron microscope(TEM), respectively. We report that NiFe films of sub-3 nm thickness show the B$_{bulk}$ = 0 and B$_{surf}$=-3 ${\times}$ 10$^{-7}$(J/$m^2$). Moreover, Curie temperature may be lowered by decreasing thickness. Coercivity become larger as temperature decreased with 0.5 nm - thick Ta/NiFe interface intermixing. Our result implies that effective magnetic properties of magnetoelastic anisotropy, saturation magnetization, and coercivity may change abruptly in nano-thick films. Thus we should consider those abrupt changes in designing nano-devices such as MRAM applications.

Synthesis of Zinc Ferrite Nanocrystallites using Sonochemical Method (음향화학법을 이용한 아연페라이트 나노입자의 합성)

  • Cho, Jun-Hee;Ko, Sang-Gil;Ahn, Yang-Kyu;Kang, Kun-Uk;An, Dong-Hyun;Choi, Eun-Jung
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.2
    • /
    • pp.71-75
    • /
    • 2007
  • Ultrasonic irradiation in a solution during the chemical reaction may accelerate the rate of the reaction and the crystallization at low temperature. We have synthesized nanometer sized zinc ferrite particles using chemical co-precipitation technique through a sonochemical method with surfactant such as oleic acid. The thermal behaviour of the zinc ferrite was determined by the thermoanalytical techniques (TGA-DSC). Powder X-ray diffraction measurements show that the samples have the spinel structure. Magnetic properties measurement were performed using a superconducting quantum interference device (SQUID) magnetometer.

A Report on 6 cases of Abdominal Obesity using Electroacupuncture Combined with Magnetic Acupuncture (전기와 자기장 복합 침 자극을 활용한 복부비만 치료 6례에 대한 증례 보고)

  • Yun, Gee Won;Lee, Hyun;Kim, Yun Joo;Kang, Jae Hui
    • Journal of Acupuncture Research
    • /
    • v.32 no.4
    • /
    • pp.213-226
    • /
    • 2015
  • Objectives : This study was aimed to show the effect of electroacupuncture combined with magnetic acupuncture on abdominal obesity without patient dieting, exercise or use of herbal medication. Methods : Women over 85 cm in waist circumference were treated with electroacupuncture combined with magnetic acupuncture. Acupuncture points were located at the abdomen ($CV_{12}$, $CV_6$, $ST_{25}$, $ST_{21}$, $SP_{15}$, $SP_{14}$), extremities ($LI_4$, $LI_{11}$, $ST_{36}$, $ST_{44}$) and were stimulated 30 minutes with 2.1~3 Gaus, 500 Hz, tolerable strength. The Interference wave forms were by Whata 153 (Medi Lab, Korea). Two or three treatment sessions per week (five or ten sessions in total) were done. Before treatment, and after the last treatment, we measured waist circumference, hip circumference, waist hip ratio, thickness of abdominal subcutaneous fat, body weight, body mass index, body fat ratio, visceral fat area, free fat mass, body fat mass and skeletal muscle mass. We also measured the subcutaneous temperature of the abdomen($CV_{12}$, $ST_{25}(Rt)$, $ST_{25}(Lt)$, $CV_6$) by using digital infrared thermal imaging(DITI). Results : In this study, significant reductions were shown in waist circumference, hip circumference, thickness of abdominal subcutaneous fat, body weight, body mass index, body fat ratio and body fat mass. There were no significant differences in waist hip ratio, free fat mass or skeletal muscle mass. There were also significant increases of the subcutaneous temperature on $CV_{12}$, $ST_{25}(Rt)$, $ST_{25}(Lt)$. Conclusions : From the above results, electroacupuncture combined with magnetic acupuncture might be an effective treatment for abdominal obesity.

The Controller Design of a 2.4MJ Pulse Power Supply for a Electro-Thermal-Chemical Gun (전열화학포용 2.4MJ 펄스 파워 전원의 제어기 설계)

  • Kim, Jong-Soo;Jin, Y.S.;Lee, H.S.;Rim, Geun-Hie;Kim, J.S.
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.12
    • /
    • pp.511-517
    • /
    • 2006
  • The key issues in high power, high energy applications such as electromagnetic launchers include safety, reliability, flexibility, efficiency, compactness, and cost. To explore some of the issues, a control scheme for a large current wave-forming was designed, built and experimentally verified using a 2.4MJ pulse power system (PPS). The PPS was made up of eight capacitors bank unit, each containing six capacitors connected in parallel. Therefore there were 48 capacitors in total, with ratings of 22kV and 50kJ each. Each unit is charged through a charging switch that is operated by air pressure. For discharging each unit has a triggered vacuum switch (TVS) with ratings of 200kA and 250kV. Hence, flexibility of a large current wave-forming can be obtained by controlling the charging voltage and the discharging times. The whole control system includes a personal computer(PC), RS232 and RS485 pseudo converter, electric/optical signal converters and eight 80C196KC micro-controller based capacitor-bank module(CBM) controllers. Hence, the PC based controller can set the capacitor charging voltages and the TVS trigger timings of each CBM controller for the current wave-forming. It also monitors and records the system status data. We illustrated that our control scheme was able to generate the large current pulse flexibly and safely by experiments. The our control scheme minimize the use of optical cables without reducing EMI noise immunity and reliability, this is resulting in cost reduction. Also, the reliability was increased by isolating ground doubly, it reduced drastically the interference of the large voltage pulse induced by the large current pulse. This paper contains the complete control scheme and details of each subsystem unit.

Quantitative Approaches for the Determination of Volatile Organic Compounds (VOC) and Its Performance Assessment in Terms of Solvent Types and the Related Matrix Effects

  • Ullah, Md. Ahsan;Kim, Ki-Hyun;Szulejko, Jan E.;Choi, Dal Woong
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.1-14
    • /
    • 2017
  • For the quantitative analysis of volatile organic compounds (VOC), the use of a proper solvent is crucial to reduce the chance of biased results or effect of interference either in direct analysis by a gas chromatograph (GC) or with thermal desorption analysis due to matrix effects, e.g., the existence of a broad solvent peak tailing that overlaps early eluters. In this work, the relative performance of different solvents has been evaluated using standards containing 19 VOCs in three different solvents (methanol, pentane, and hexane). Comparison of the response factor of the detected VOCs confirms their means for methanol and hexane higher than that of pentane by 84% and 27%, respectively. In light of the solvent vapor pressure at the initial GC column temperature ($35^{\circ}C$), the enhanced sensitivity in methanol suggests the potential role of solvent vapor expansion in the hot injector (split ON) which leads to solvent trapping on the column. In contrast, if the recurrent relationships between homologues were evaluated using an effective carbon number (ECN) additivity approach, the comparability assessed in terms of percent difference improved on the order of methanol (26.5%), hexane (6.73%), and pentane (5.24%). As such, the relative performance of GC can be affected considerably in the direct injection-based analysis of VOC due to the selection of solvent.