• 제목/요약/키워드: Thermal insulation performance

검색결과 413건 처리시간 0.023초

경량 무기 단열재에 관한 연구 (A Study on Light-weight Inorganic Insulation)

  • 신현욱;송훈;추용식;이종규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.217-218
    • /
    • 2012
  • To prevent energy waste in buildings used heat insulator. Heat insulator materials can be classified inorganic and organic. The organic material is be toxic gas emission, when a fire occurs. And it has lower water resistance. The inorganic material is heavy and worse thermal performance than organic materials. This study focused on thermal conductivity and density of inorganic foam material for using industrial by-products materials.

  • PDF

단열성 시험 방법을 통한 진공유리의 구성 및 필러 배치에 따른 열 성능 평가 (The Evaluation of Thermal Performance of Vacuum Glazing by Composition and the Pillar Arrangement through Test Method of Thermal Resistance)

  • 조수;김석현;엄재용
    • 한국태양에너지학회 논문집
    • /
    • 제35권1호
    • /
    • pp.61-68
    • /
    • 2015
  • The advanced counties effort to the supplement of the zero energy buildings for the global building energy saving. In the middle of the development of passive technology, the government has to effort to the energy saving of buildings by enhanced performance of the window thermal insulation. By the method of enhanced performance of window thermal insulation, the use of vacuum double glazing saves the energy consumption in building. This glazing has low U-value(heat transmission coefficient) than normal double glazing. The vacuum glazing enhanced thermal insulation performance by vacuum space of between the glass and glass. For this vacuum glazing, pillar maintain the space between glass and glass. But this structure cause the raising the heat transmission coefficient in pillar approaching glass. This study confirmed the U-value by the test method of thermal resistance for windows and doors. Also this study confirmed the variation of heat transmission coefficient by the structure of vacuum glazing. And this study measured the surface temperature of the vacuum glazing about pillar approaching glass and vacuum space in cool chamber and hot box. That result, this study confirmed U-value of $0.422W/m^2{\cdot}K$ of vacuum glazing. Also this study confirmed U-value of $0.300{\sim}0.422W/m^2{\cdot}K$ by various the structure of vacuum glazing. And this study confirmed the heat flow in pillar approaching glass.

건축물의 창틀과 벽체 사이 열교방지공법의 LCC 분석 (A Study on Life Cycle Cost Analysis of Thermal Bridge Barrier Between Window Frame and Concrete Wall)

  • 박철용;김웅회;이상희;남승영;윤길호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.59-60
    • /
    • 2019
  • Thermal bridge on a building envelope causes additional heat loss which increases the heating energy consumption. As the higher building insulation performance is required, heat loss through thermal bridge becomes higher proportion among total building heating energy consumption. For the exterior insulation and finish system, thermal bridge between window frame and concrete wall should be constidered as one of main reasons of heat loss. In this study, the thermal bridge barrier between window frame and concrete wall(STAR) was proposed as the best practice for reducing thermal bridge. The STAR was confirmed that the use of thermal bridge barrier imporved the annual heat energy capacity by 35% or more and the innitial construction cost by 7.4% or less because of additional interior insulation against condensation. Finally the life cycle cost during 20 year by heating energy of a building reduced by 25% or more compared with the exist technology. This STAR thermal bridge barrier will be used as the main technology to improve the energy efficiency of building.

  • PDF

혼합 양에 따른 경질 폴리우레탄폼의 밀도 및 열전도율에 관한 연구 (A Study on the Density and Thermal Conductivity of Rigid Polyurethane Foam According to Mixing Amount)

  • 신종현;조수연;정의인;김봉주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.127-128
    • /
    • 2021
  • Rigid urethane foam is widely applied because it is light and has superior insulation performance compared to insulation materials such as EPS or glass wool. However, it has the disadvantage of being vulnerable to fire. Therefore, in this study, before proceeding with the research to improve the fire resistance of the rigid polyurethane foam, we would like to investigate the change in density and thermal conductivity of the rigid polyurethane foam according to the change in the mixed weight of the main material and the curing agent. It was found that the density increased as the mixed weight increased. The thermal conductivity showed similar values overall. As for the density distribution, the central part was low and the outer part was high.

  • PDF

Optimization approach of insulation thickness of non-vacuum cryogenic storage tank

  • MZAD, Hocine;HAOUAM, Abdallah
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권1호
    • /
    • pp.17-23
    • /
    • 2020
  • Cryogenic insulation systems, with proper materials selection and execution, can offer the highest levels of thermal performance. Insulations are listed in order of increasing performance and, generally, in order of increasing cost. The specific insulation to be used for a particular application is determined through a compromise between cost, ease of application and the effectiveness of the insulation. Consequently, materials, representative test conditions, and engineering approach for the particular application are crucial to achieve the optimum result. The present work is based on energy cost balance for optimizing the thickness of insulated chambers, using foamed or multi layered cryogenic shell. The considered insulation is a uniformly applied outer layer whose thickness varies with the initial and boundary conditions of the studied vessel under steady-state radial heat transfer. An expression of the optimal insulation thickness derived from the total cost function and depending on the geometrical parameters of the container is presented.

준불연 외단열시스템의 역학적 특성에 관한 연구 (Mechanical Properties of External Thermal Insulation Composite System with Quasi-Non-Combustible Performance)

  • 최기선;하수경;오근영;박금성;류화성
    • 한국건축시공학회지
    • /
    • 제21권5호
    • /
    • pp.507-518
    • /
    • 2021
  • 외단열시스템에서 준불연 성능을 확보한 부착식 탄산칼슘계 복합단열판은 효과적인 단열성능과 화재안전성을 강화한 것으로, 본 연구에서는 준불연 복합단열판을 대상으로 부착식 준불연 외단열시스템의 구조설계 기초데이터를 확보하기 위하여 복합단열판 및 구성재의 역학적 시험을 수행하였다. 국내외 시험규격을 참조하여 시험체를 제작하였으며, 인장강도, 압축강도, 굴곡강도, 전단강도를 시험 평가하였다. 시험결과로부터 준불연 복합단열판의 강도특성치를 도출하였고, 현행 KS M ISO 4898에서 제시하는 최소 요구물성을 확보하고 있는 것을 검증하였다. 또한, 본 연구에서 사용한 준불연 외단열시스템은 지속적 중량 하중을 받지 않는 벽체의 외단열시스템으로 사용이 가능한 것을 확인하였다.

폐유리분말과 플라이애시를 사용한 경량 발포소재의 물리적 특성 (Physical Properties of Light Weight Foamed Glass Using Waste Glass Powder and Fly Ash)

  • 송훈;신현욱
    • 한국건설순환자원학회논문집
    • /
    • 제3권4호
    • /
    • pp.328-334
    • /
    • 2015
  • 건축용 단열재는 에너지 절약을 목적으로 적용되며 불연 및 내화성능이 요구되는 부위는 무기계 섬유를 주재료로 사용하는 미네랄울 및 글라스울 소재가 적용된다. 하지만 무기계 소재인 미네랄울이나 글라스울은 특성상 수분에 취약하여 뭉침 및 처짐 현상 등이 발생하여 단열효과가 떨어지며 유기계 소재인 폴리스티렌폼이나 우레탄폼 등은 화재에 취약하고 일산화탄소 발생에 의한 가스유해성 등으로 적용에 한계를 갖고 있다. 본 연구에서는 폐유리분말과 플라이애시를 사용하여 가볍고 열전도율이 낮은 무기계 경량 발포소재를 제조하고 물리적 특성을 분석하여 단열용 제품으로서의 가능성을 확인하고자 하였다. 연구결과 폐유리분말과 플라이애시를 사용한 경량 발포소재는 균일한 공극을 형성하며 발포하였고 경량이며 불연재료이므로 불연성능 요구되는 부위에 사용이 가능하다.

건축물의 단열성능 검증 시스템 구축을 위한 실험적 연구 (An Experimental Study to Establish a System for Vertifying the Insulation Performance of Buildings)

  • 김현진;최세진
    • 한국건축시공학회지
    • /
    • 제21권3호
    • /
    • pp.203-211
    • /
    • 2021
  • 최근 건축물의 에너지 사용 저감을 위한 단열 설계기준은 강화되고 있다. 단열공사는 건축물의 단위면적당 1차 에너지 소요량 저감을 위한 가장 효율적인 방법임에도 불구하고, 건축 시공 및 준공검사 과정에서 단열성능에 대한 평가(검사) 기준이 없는 실정이다. 본 연구는 열관류율 측정장비(TESTO 435)를 활용하여 공동주택의 외벽 열관류율을 간편하게 실험 할 수 있는 방법과 분석기법에 대한 기준을 구축하여 객관적인 데이터를 제공하는 데 목적이 있다. 실험 대상 외벽의 단위면적당 비열(열용량)이 20 kJ(m2·K)를 초과하여 ISO 9869-1에 적합한 종료 시점의 데이터를 평균법으로 분석했다. 3일 연속 열관류율 측정값은 설계값 대비 +5% 이내로 허용오차 범위 내로 수렴했고, 일자별 열관류율의 표준편차는 1-Day > 3-Day > 2-Day 순으로 작아졌고, 시간대별 열관류율 표준편차는 00:00~24:00 > 19:00~07:00 > 00:00~07:00 순으로 줄어 들었다. 특히, 측정일자별로 00:00~07:00 시간대의 열관류율 값은 설계값 대비 -3%~+2% 편차로 거의 일치하였다.

고성능 진공단열재의 건축적인 적용에 관한 연구 (Research on the Architectural Applications of High-Performance Vacuum Insulation Panel)

  • 권영철;김석
    • 토지주택연구
    • /
    • 제10권3호
    • /
    • pp.23-32
    • /
    • 2019
  • 현존하는 단열재 중 가장 열전도율이 낮은 진공단열재(VIP; Vacuum Insulation Panel)는 특수한 재질의 외피재(Envelope)와 외피재 내부의 심재(Core Material), 그리고 단열재 내부의 공기를 흡착하는 흡착제(Getter)로 구성되어 있고, 단열성능을 극대화하기 위해 내부를 진공처리한 제품이다. 진공단열재의 외피재는 알루미늄 박막 필름이 주로 사용되며, 진공단열재의 수명 및 신뢰성을 결정하는 중요한 소재이다. 본 연구를 통하여 불연성이 확보된 Fiber Glass 심재 진공단열재의 방화성능 및 단열성능 확인과 함께 건축적인 적용가능성을 검토하였으며 그 내용을 정리하면 다음과 같다. 1) 20mm 두께의 Fiber Glass 심재 진공단열재의 열전도율이 0.00177W/m·K로, 두께 20mm로 지역별, 부위별 강화된 단열기준을 모두 충족할 수 있음을 알 수 있었다. 2) 진공단열재에 대한 불연성능시험과 가스유해성시험 결과, 불연재료로 적합한 것으로 나타났다. 3) 불연 진공단열재의 장기내구성 시험결과, 25년이 지나더라도 스치로폼 및 유리섬유에 비해 10배 이상의 단열성능을 유지할 수 있음을 알 수 있었다. 4) 건물의 외벽 열관류율 0.12W/㎡K 이하를 만족하기 위해, 준불연성능이 확보된 단열재인 "가"등급의 비드법 보온판 2종 4호와 페놀폼을 사용한다면 각각 280mm, 170mm 이상을 써야하지만, 불연 진공단열재는 20mm 두께로 동일 단열기준을 만족할 수 있는 것으로 나타났다.5) 고성능 진공단열재는 열관류율 0.12W/㎡K 이하를 기준으로 가격경쟁력이 페놀폼 대비 약 1,500원/㎡ 뛰어난 것으로 나타났다.

Development of Efficient Curing Sheet for Thermal Insulation Curing of Concrete in Cold Weather

  • Han, Cheon-Goo;Son, Myung-Sik;Choi, Hyun-Kyu
    • 한국건축시공학회지
    • /
    • 제12권3호
    • /
    • pp.291-298
    • /
    • 2012
  • For cold weather concreting, frost damage at early age is generated in the concrete, and problems such as delaying of setting and hardening and lowering of strength manifestation emerge due to the low outside air temperature at the early stage of pouring, making the selection of an effective curing method critically important. Unfortunately, the tent sheet currently used as the curing film for heating insulation at work sites, not only has the problems of inferior permeability and extremely deteriorated airtightness, but a phenomenon of continuous fracturing is also generated along the direction of fabric of the material itself, presenting difficult circumstances for maintaining adequate curing temperature. The aim of this study was to develop an improved bubble sheet type curing film for heating insulation of cold weather concrete by combining mesh-tarpaulin, which has excellent tension properties, with bubble sheet, which offers superior insulation performance. The analysis showed that the improved curing film in which BBS1 is stacked to MT was a suitable replacement for curing films currently in use, as it has better permeability, tension property, and insulation performance than the T type film used at work sites today.