• Title/Summary/Keyword: Thermal environment control

Search Result 492, Processing Time 0.027 seconds

Study on Energy Saving Possibilities through Analysis of Environment Control Elements & Natural Ventilation Performance using the CFD & Measurement (CFD와 실측을 이용한 환경제어요소 도입 및 주택 자연환기 성향 검토를 통한 에너지 절감가능성 고찰)

  • Oh, Byoungchull;Lee, Sunyoung
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.27-37
    • /
    • 2014
  • Heat island is caused by changes of land coverage structure of cities and use of energy in buildings. As a result energy use in buildings get to increase further followed by rising of GHG emission and deteriorating climate change. Eco-friendly housing complex is a kind of plan that applies environmental control elements like water and green spaces to housing complex. With these methods, it can be expected to create thermal environment of indoor and outdoor. In this paper quantitative examination is studied on using CFD to find out the effects of river, water permeable, parks and planting on thermal environment. And by comparing field measurements with CFD results which are aimed to development phase housing complex, feasibility and usability of the CFD analysis results are confirmed. And also, analysis on the ventilation performance followed by natural ventilation system is analyzed by selecting one building in housing complex. Based on the results, the possibilities of energy reduction through making thermal environment and applying natural ventilation are studied. With these outcomes, creating thermal conditions and using natural ventilation would be contributed to GHG reduction.

Evaluation of thermal comfort and cooling loads for a multistory building

  • Lykartsis, Athanasios;B-Jahromi, Ali;Mylona, Anastasia
    • Advances in Energy Research
    • /
    • v.5 no.1
    • /
    • pp.65-77
    • /
    • 2017
  • The latest UK Climate Projections (UKCP09) show that mean daily temperatures will increase everywhere in the United Kingdom. This will significantly affect the thermal and energy performance of the current building stock. This study examines an institutional fully glazed building and looks into the changes in the cooling loads and thermal comfort of the occupants during the occupied hours of the non-heating period. Furthermore, it investigates the effect of relative humidity (RH) on thermal comfort. The Design Summer Year (DSY) 2003 for London Heathrow has been used as a baseline for this study and the DSY 2050s High Emissions scenario was used to examine the performance of the building under future weather conditions. Results show a 21% increase of the cooling loads between the two examined scenarios. Thermal comfort appears to be slightly improved during the months of May and September and marginally worsen during the summer months. Results of the simulation show that a relative humidity control at 40% can improve the thermal comfort for 53% of the occupied hours. A comparison of the thermal comfort performance during the hottest week of the year, shows that when the relative humidity control is applied thermal comfort performance of the 2050s is similar or better compared to the thermal comfort performance under the baseline.

A Study on Thermal Heating Control Performance of Automatic Thermostatic Valves in Floor Radiant Heating System (바닥난방 시스템의 열환경 개선을 위한 제어방안 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon;Kim, Kyung-Chul;Jang, Sa-Yun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.973-978
    • /
    • 2009
  • In this study, the thermal environment characteristics of On-Off control and thermal difference proportional control method in floor radiant heating system were researched by computer simulation. For the analysis of unsteady heat transfer phenomena in household, the method of using electrical equivalent R-C circuit is applied, and radiation heat transfer between panel, ceiling and walls in household is calculated by enclosure analysis method. The parametric study on two control methods, conventional on-off control and temperature error based time control(T.E.B.T.C.) method, are performed to compare thermal heating control performances, respectively.

  • PDF

Design and Performance Test of a Cryogenic Blower for Space Thermal Environment Simulation (우주 열환경 모사용 소형 극저온 블로워 설계 및 성능평가)

  • Seo, Heejun;Ahn, Sungmin;Huh, Hwanil
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.10
    • /
    • pp.833-839
    • /
    • 2013
  • Thermal vacuum test should be performed prior to launch to verify satellites' functionality in a harsh space environment which is represented by extremely cold temperatures and vacuum conditions. A thermal vacuum chamber which consists of a vacuum vessel, a pumping system, and a thermal control system are used to perform thermal vacuum tests of a satellite system and its components. A cryogenic blower is a core component of the closed loop thermal control system for thermal vacuum chambers. This paper describes the fan design of the cryogenic blower, the design of the thermal protection interface between the driving part and the fluid part, which were verified by thermal and structural analyses. The performance of the cryogenic blower is confirmed by similarity test on the test bench.

Development of Variable Duty Cycle Control Method for Air Conditioner using Artificial Neural Networks (신경회로망을 이용한 에어컨의 가변주기제어 방법론 개발)

  • Kim, Hyeong-Jung;Doo, Seog-Bae;Shin, Joong-Rin;Park, Jong-Bae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.10
    • /
    • pp.399-409
    • /
    • 2006
  • This paper presents a novel method for satisfying the thermal comfort of indoor environment and reducing the summer peak demand power by minimizing the power consumption for an Air-conditioner within a space. Korea Electric Power Corporation (KEPCO) use the fixed duty cycle control method regardless of the indoor thermal environment. However, this method has disadvantages that energy saving depends on the set-point value of the Air-Conditioner and direct load control (DLC) has no net effects on Air-conditioners if the appliance has a lower operating cycle than the fixed duty cycle. In this paper, the variable duty cycle control method is proposed in order to compensate the weakness of conventional fixed duty cycle control method and improve the satisfaction of residents and the reduction of peak demand. The proposed method estimates the predict mean vote (PMV) at the next step with predicted temperature and humidity using the back propagation neural network model. It is possible to reduce the energy consumption by maintaining the Air-conditioner's OFF state when the PMV lies in the thermal comfort range. To verify the effectiveness of the proposed variable duty cycle control method, the case study is performed using the historical data on Sep. 7th, 2001 acquired at a classroom in Seoul and the obtained results are compared with the fixed duty cycle control method.

Environment-Friendly Control of Cucumber Downy Mildew Using Chlorine Dioxide (이산화염소수를 활용한 오이 노균병 친환경방제)

  • Kim, Byung-Ryun;Hahm, Soo-Sang;Kwon, Mi-Kyung;Kim, Yun-Jeong;Kim, Woon-Seop;Song, Jeong-Young;Oh, Sang-Keun;Ju, Jung-Il
    • Research in Plant Disease
    • /
    • v.27 no.4
    • /
    • pp.149-154
    • /
    • 2021
  • Pseudoperonospora cubensis (downy mildew) is highly virulent to various Cucurbitaceae crops, including cucumber (Cucumis sativus). We tested chlorine dioxide application in a plastic greenhouse for environment-friendly control of downy mildew disease. Spraying diluted chlorine dioxide suppressed downy mildew disease with 41.2% control efficacy. Thermal fogging with chlorine dioxide had a high control efficacy of 80.9%, confirming that this approach is useful for environment-friendly downy mildew control. Using thermal fogging to control diseases that are greatly affected by humidity, such as downy mildew, may be more effective compared with conventional dilution spray control methods.

An Experimental Study on the Thermal Environmental Measurements and Subjective Reponses in Summer Season for the Korean Traditional Houses in Chonnam Province (전남지방 전통주택의 하절기 온습도 측정 및 주관평가에 관한 실험적 연구)

  • Kim Sun-Woo;Lee Tai-Kang;Kim Hyung-Ryul
    • Journal of the Korean housing association
    • /
    • v.17 no.2
    • /
    • pp.41-46
    • /
    • 2006
  • This study aims to analyzed thermal comfort characteristics and subject response for thermal environment of Korean traditional houses.. The air temperature and humidity in the living area of the residence were measured in during a day. And the subject response were surveyed to evaluate of controling the thermal environment factor (temperature, humidity, comfort) of the korean traditional houses. As a result, the variation of air temperature and humidity of most rooms are considerably static while condition of outdoors are much varied, it is showed that indoor climate has been controled with traditional soiled walls. And environmental control for the air temperature and humidity is estimated considerably satisfactory.

Analyzing the Change of Indoor Thermal Environment with the Introduction of the Water Space in Exterior Housing (주거 외부 수공간 도입에 따른 실내 온열 환경 변화 분석)

  • Oh, Sang-Mok;Oh, Se-Gyu;Won, Hyun-Seong
    • Journal of the Korean housing association
    • /
    • v.21 no.2
    • /
    • pp.41-48
    • /
    • 2010
  • This study shows how the water space outside the housing impacts the indoor thermal environment. CFD simulation was used for this experiment to analyze the interior environment focusing on the effect of temperature control and the thermal comfort. A shape of perfect square, which creates the very basic space formation, was used and the simulation was processed looking at the size, distance, and the location of the water space. The results of the experiment are as follows. Firstly, introducing a water space with the same floor area size of the simulation model decreased the indoor temperature by 1 Celsius (3.72%). It was determined the interior environment was considered as a comfort zone when the water space was greater than 70% of the floor area. Secondly, there was not much influence to the level of thermal comfort of the interior environment when the distance to the water space from the housing was greater than 2 meters. Lastly, interpreting the location of water space, the effect of controlling the total areas' temperature was the greatest following with the surrounding of the formation. There barely was any change to the temperature considering the side and the rear of the area.

Dynamic Model for Ocean Thermal Energy Conversion Plant with Working Fluid of Binary Mixtures

  • Nakamura, Masatoshi;Zhang, Yong;Bai, Ou;Ikegami, Yasuyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2304-2308
    • /
    • 2003
  • Ocean thermal energy conversion (OTEC) is an effective method of power generation, which has a small impact on the environment and can be utilized semi-permanently. This paper describes a dynamic model for a pilot OTEC plant built by the Institute of Ocean Energy, Saga University, Japan. This plant is based on Uehara cycle, in which binary mixtures of ammonia and water is used as the working fluid. Some simulation results attained by this model and the analysis of the results are presented. The developed computer simulation can be used to actual practice effectively, such as stable control in a steady operation, optimal determination of the plant specifications for a higher thermal efficiency and evaluation of the economic prospects and off-line training for the operators of OTEC plant.

  • PDF

A Time Dependent Analysis of Thermal Environment in Beehouse

  • Lee, Suk-Gun;Li, Zhenhai;Choi, Kwang-Soo
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1997.11a
    • /
    • pp.20-26
    • /
    • 1997
  • The design or analysis of beehouse inside temperature environment based on steady heat transfer theory causes much deviation and theoretically it is impossible to control the inside temperature lower than the outside temperature under the condition that the bee produces heat and no cooling equipment is installed. But in practical use of beehouse, the inside temperature is somehow lower than the outside temperature because of the heat inertia of concrete floor. (omitted)

  • PDF