• 제목/요약/키워드: Thermal effect

검색결과 6,983건 처리시간 0.038초

복합재 통신위성 안테나의 우주환경 열해석 (Thermal Analysis of Composite Satellite Antenna Structure in Space Environment)

  • 김경남;김창호;정기모;한재흥
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 춘계학술발표대회 논문집
    • /
    • pp.77-80
    • /
    • 2002
  • Thermal analysis has been performed to evaluate the thermal effect on composite antenna (Ka-band) structure in space environment. The concepts of thermal control are also presented to maintain the antenna components within respective temperature limits. A steady-state algorithm of I-DEAS' thermal analysis software was utilized to predict both maximum and minimum temperature, maximum gradient temperature, and temperature distribution on each antenna component.

  • PDF

태양열 해수담수화 시스템을 위한 다중효용 담수기 개발 (Development of Multi Effect Distillation for Solar Thermal Seawater Desalination System)

  • 주홍진;황인선;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제31권1호
    • /
    • pp.1-7
    • /
    • 2011
  • This study was accomplished to evaluate the performance of Multi Effect Distillation(MED) for solar thermal desalination system. It was designed Multi effect distillation with $3m^3$/day capacity and Shell&Tube type heat exchanger. Also, The effective heat transfer of Shell&Tube heat exchanger was used Cu(90%)-Ni(10%) corrugated tube. The parameters relating to the performance of Multi Effect Distillation are known as hot water flow rate. The experimental conditions for each parameters were $18^{\circ}C$ for sea water inlet temperature, $6m^3$/hour sea water inlet volume flow rate, $75^{\circ}C$ for hot water inlet temperature, 2.4, 3.6, and $4.8\;m^3$/hour for hot water inlet volume flow rate, respectively. The results are as follows, Development for Multi effect distillation was required about 40kW heat and 35kW cooling source to produce $3m^3$/day of fresh water. Based on the results of this study, It makes possible to secure economics of desalination system with solar energy which is basically needed development of high efficiency fresh water generator.

피복합금을 사용한 Bi-2223 선재의 열전도도 및 전기전도도 특성평가 (Effects of Ag-alloy sheath on thermal/electrical conductivity of Bi-2223 superconductor tapes)

  • 장석헌;지봉기;임준형;주진호;나완수
    • Progress in Superconductivity
    • /
    • 제4권2호
    • /
    • pp.180-183
    • /
    • 2003
  • We evaluated the effect of alloying-element additions to Ag sheath on thermal conductivity of Bi-2223 superconductor tapes. In order to evaluate the effect of sheath alloys and their configuration on the properties of tape, various combinations of Ag and Ag alloys were selected as inner and outer sheath. Thermal conductivity of the tapes was measured by using thermal integral method at 10∼120 K. It is observed that the presence of alloying-elements such as Mg, Sb, and Au in Ag sheath results in decreased thermal conductivity at low temperature. Specifically, the thermal conductivity of AgMg, AgSb, and AgAu at 40 K were 411.4, 142.3, and 109.7 W/(m·K), respectively, which is about 2∼9 times lower than that of Ag (1004.6 W/(m·K)). In addition, the thermal conductivity of alloy-sheathed tape was significantly dependent on their values of constituent sheath materials.

  • PDF

수면 열환경에 관한 연구 (II) -침구의 경량화에 따른 보온력- (Studies on the Thermal Environment in Sleeping (II) -Thermal Insulation Effect of Bedding on Lightweight-)

  • 성수광
    • 한국의류학회지
    • /
    • 제17권3호
    • /
    • pp.470-474
    • /
    • 1993
  • This study carried out to get some fundamental data for designing lightweight bedding. In This study, the wool blanket, polyester/cotton blended blanket and down quilt were manufactured with a varied materials, structural factors such as yam count, fabric density respectivelyarn. And also, the thermal insulation value of the bedding were measured by warmth retaining tester. In addition, this paper examines the influence of varying materials, structural factors and blanket layers on the thermal insulation effect of the bedding. The main results obtained from this study are as follow : 1. The design of lightweight blankets make an attempting with a varying materials and structural factors such as yam count, fabric densityarn. 2. Almost, the design of lightweight blankets for polyester/cotton blended blanket and down quilt make an attempting without reduction in thermal insulation values. 3. The 6 layers of blanket have less thermal insulation value than the 6 times of blanket for under a layer have. About 27~32% decrease is observed in thermal insulation value of blanket for under 6 layer. 4. The thermal insulation value and areal weight of blankets have a positive relation between the thermal insulation value(Y) and areal weight(X) is based on the following equation. wool blanket : Y = 1.0850X + 0.4188 (r = 0.9992) PIC blended blanket : Y = 0.8845X + 0.3034 (r = 0.9999)

  • PDF

열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향 (An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe)

  • 최우석;박이동;김철주;황영규
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1995년도 춘계학술발표회 초록집
    • /
    • pp.69-76
    • /
    • 1995
  • The horizontal thermal storage tank with heat pipe which is suitable for the sensible heat storage system is able to store a hot water from the heat source such as heating pad efficiently and to supply a hot water to load rapidly. Therefore Arrangement of heating pad affects thermal flow and thermal storage efficiency. So, if effective arrangement is decided for condition of constant number of heating pad, the more rapid thermal flow effect and higher thermal storage efficiency is obtainable by active heat transfer. In this experiments, number of heating pad is ranged from three, five and nine, and when number of heating pad is constant, arrangement are two types of concentration-type and dispersion-type. As a result, for the case of concentration-type of heating pad, strong entrainment take place in horizontal thermal storage tank with heat pipe by active heat transfer and in the constant number of heating pad, the concentration-type has the higher efficiency with about 5∼6% than the dispersion-type. Therefore, when heating pad is equipted to horizontal thermal storage tank with heat pipe, concentration-type of heating pad is an efficient design in constant number. of heating pad.

  • PDF

A SUMMARY OF 50th OECD/NEA/CSNI INTERNATIONAL STANDARD PROBLEM EXERCISE (ISP-50)

  • Choi, Ki-Yong;Baek, Won-Pil;Kang, Kyoung-Ho;Park, Hyun-Sik;Cho, Seok;Kim, Yeon-Sik
    • Nuclear Engineering and Technology
    • /
    • 제44권6호
    • /
    • pp.561-586
    • /
    • 2012
  • This paper describes a summary of final prediction results by system-scale safety analysis codes during the OECD/NEA/CSNI ISP-50 exercise, targeting a 50% Direct Vessel Injection (DVI) line break integral effect test performed with the Advanced Thermal-Hydraulic Test Loop for Accident Simulation (ATLAS). This ISP-50 exercise has been performed in two consecutive phases: "blind" and "open" phases. Quantitative comparisons were performed using the Fast Fourier Transform Based Method (FFTBM) to compare the overall accuracy of the collected calculations. Great user effects resulting from the combination of the possible reasons were found in the blind phase, confirming that user effect is still one of the major issues in connection with the system thermal-hydraulic code application. Open calculations showed better prediction accuracy than the blind calculations in terms of average amplitude (AA) value. A total of nineteen organizations from eleven countries participated in this ISP-50 program and eight leading thermal-hydraulic system analysis codes were used: APROS, ATHLET, CATHARE, KORSAR, MARS-KS, RELAP5/MOD3.3, TECH-M-97, and TRACE.

Numerical modelling of effective thermal conductivity of hardened cement paste

  • Cheng Liu;Qiang Liu;Jianming Gao;Yunsheng Zhang
    • Computers and Concrete
    • /
    • 제32권6호
    • /
    • pp.567-576
    • /
    • 2023
  • In this study, a 3D microstructure-based model is established to simulate the effective thermal conductivity of cement paste, covering varying influencing factors associated with microstructure and thermal transfer mechanisms. The virtual cement paste divided into colloidal C-S-H and heterogeneous paste are reconstructed based on its structural attributes. Using the two-level hierarchical cement pastes as inputs, a lattice Boltzmann model for heat conduction is presented to predict the thermal conductivity. The results suggest that due to the Knudsen effect induced by the nanoscale pore, the thermal conductivity of air in C-S-H gel pore is significantly decreased, maximumly accounting for 3.3% thermal conductivity of air at the macroscale. In the cement paste, the thermal conductivities of dried and saturated cement pastes are stable at the curing age larger than 100 h. The high water-to-cement ratio can decrease the thermal conductivity of cement paste.

알루미나 세라믹에 대한 열충격 손상의 비파괴적 평가 (Nondestructive Evaluation of Thermal Shock Damage for Alumina Ceramics)

  • 이준현;이진경;송상헌
    • 대한기계학회논문집A
    • /
    • 제25권8호
    • /
    • pp.1189-1196
    • /
    • 2001
  • The objective of this paper is to investigate the applicability of acoustic emission(AE) technique to monitor the progress of the thermal shock damage on alumina ceramic. For this purpose, alumina ceramic specimen was heated in the furnace and then was quenched in the water tank. When the specimen was quenched in the water tank, complex AE signals due to the initiation of micro-cracks and boiling effect were generated by the progress of thermal shock damage. These mixed AE signals have to be classified for monitoring the degree of the thermal shock damage of alumina ceramics. In this paper, the mixed AE signals generated from both the boiling effect and the crack initiation under thermal shock test was analyzed. The characteristics of AE signals were also discussed by considering the variation of bending strength and Yongs modulus of specimens.

전단율에 의존적인 비뉴턴 유체의 열전도율이 열전달 향상에 미치는 영향 (The effect of the shear-rate dependent thermal conductivity of non-Newtonian fluids on the heat transfer enhancement)

  • 신세현;이성혁;손창현
    • 대한기계학회논문집B
    • /
    • 제20권5호
    • /
    • pp.1717-1724
    • /
    • 1996
  • The present study investigates the effect of the shear rate-dependent thermal conductivity of non-Newtonian fluids on the heat transfer enhancement in a pipe flow. An axially-constant heat flux boundary condition was adopted in the thermal fully developed region. The present analytical results of Nusselt numbers for various non-Newtonian fluids show heat transfer enhancement over those of a shear rate-independent thermal conductivity fluids. The present analytical results showed good agreement with the previous experiments which excluded the temperature-dependent viscosity effect on heat transfer. This study also proposes the use of a shear rate-dependent thermal conductivity fluids in the design of a heat exchanger for heat transfer enhancement as well as reduction of fouling.

고속주축의 냉각조건과 후반부 냉각 유무에 따른 열특성 연구 (A Study on the Thermal Characteristics of a High Speed Spindle according to the Cooling Existence of Rear Part and the Cooling Conditions)

  • 최대봉;김수태;이석준;김창용
    • 한국기계가공학회지
    • /
    • 제11권1호
    • /
    • pp.50-55
    • /
    • 2012
  • The important problem in high speed spindle is to reduce and minimize the thermal effect by motor and bearing. This paper presents the thermal characteristic analysis for a high speed spindle with and without cooling at the rear part, considering the viscosity and the flow rate of cooling oil. A high speed spindle is composed of angular contact ceramic ball bearings, high speed built-in motor, oil jacket cooling and so on. The thermal analyses of high speed spindle need to minimize the thermal effect and maximize the cooling effect and they are carried out under the various cooling conditions. Heat generations of the bearing and the high speed motor are estimated from the theoretical and experimental data. This result can be applied to the design and manufacture of a high speed motor spindle.