• Title/Summary/Keyword: Thermal difference

Search Result 2,304, Processing Time 0.034 seconds

An Analysis on Thermal Insulation Effect of Farm Structures Coated with Surface Treatment (표면코팅 구조재의 달열효과 분석)

  • Suh, Won-Myung;Yoon, Yong-Cheol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.4
    • /
    • pp.39-46
    • /
    • 2004
  • This experiment was carried out to study on the effect of surface coating on thermal insulation of farm structures to improve thermal resistance and reflective effect of solar radiation. Nine different types of experimental specimen were compared in the temperature variations of inside and outside; A, B, C, D. E and F types are box container and G, H and I types are drum container. The size of these containers is $1,500{\times}2,000{\times}2,500$ mm and ${\varphi}$ $280{\times}330$ mm, respectively. Specimen of 3-type box(A, B, C) is galvanized steel sheet of thickness 0.45 mm. D, E and F types are sandwich panel of the thickness 50 mm inserted with urethane, glass wool and polystyrene form, respectively. G, H and I types are paint pot using in general. The surface of A. D, E, F and I types didn't any treatment, B, C and G types were treated with thermal insulation coating on the outside surface(B, G) or the inside and outside surface(C). And H type was treated with water paint coating on the only outside surface. In general, the experimental results showed the following tendencies; In case of A, B and C types. it was found that the thermal insulation effect of types coated with thermal insulation coating was improved remarkably than that of no treatment. And the thermal insulation effect between steel sheet and sandwich panel type was nearly similar There was not a significant difference of thermal insulation effect between thermal insulation coating and water paint coating. In time of drum container filled with rough rice, The difference of heat transfer tendency and temperature variation among surface treatments was nearly similar that of box types of galvanized steel sheet. And there was time lag about 6 hours between the temperature of middle part of rice and that of inside or outside surface.

Evaluation of Thermal Physiological Responses and Comfort in Vitamin E Fabric (비타민 E 소재의 인체생리반응 및 쾌적성 평가)

  • Im Soon;Chung Myung-Hee
    • The Research Journal of the Costume Culture
    • /
    • v.13 no.3 s.56
    • /
    • pp.406-413
    • /
    • 2005
  • This study performed the evaluation of skin temperature, heart rate, temperature and relative humidity of microclimate, and subjective sensation, such as thermal sensation, wet sensation and comfort sensation to estimate physiological responses of the human body and its comfortable feeling to the vitamin E fabric. Experiments were performed on the five healthy adult women whose average age was 21, at climate chamber in which temperature, relative humidity and air current were set up below $30{\pm}\;1^{\circ}C$, $50{\pm}\;15\%$ and 0.2m/s, respectively. Two kinds of clothes were used for experiments: unfinished sports clothes, with the same form and the same size, of short-sleeved knit shirt and long trousers made with $100\%$ cotton, and finished sports clothes printed with the vitamin E solution of the level of $0.88\%$. Exercises of walking (about 105 steps/minute) with the exercise intensity of 2.5 were performed for 20 minutes using treadmill. In result, the study showed significant difference (p<0.01) in average skin temperature between unfinished and finished sport clothes, and represented higher value with having unfinished sport clothes in wear than with finished one. The study also showed significant difference (p<0.01) in heart rate only during the period of exercise, and represented higher value generally with unfinished sport clothes than with finished one. There were significant differences not only in temperature of microclimate (p<0.01) but also in humidity of microclimate (p<0.05) between two sport clothes. As for the evaluation of subjective sensation, the study showed significant difference (p<0.05) in thermal sensation between the two kinds of sport clothes, significant difference in wet sensation only during the period of exercise, and significant difference (p<0.05) in comfort sensation only during the period of recovery.

  • PDF

Effects of Urban Park on Thermal Comfort in Summer - An Analysis of Microclimate Data of Seoul Forest Park - (여름철 도시공원의 열환경 개선 효과 - 서울숲 미기상 관측자료 분석을 중심으로 -)

  • Zoh, Hyunmin Daniel;Kwon, Tae Kyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.6
    • /
    • pp.30-41
    • /
    • 2022
  • This study investigates the heat mitigation effects and thermal comfort improvement due to urban parks during summer. Self-developed monitoring devices to measure long-term microclimate data were installed in three spots, including the park plaza, waterside, and roadside in Seoul Forest Park, and measurements were taken from July 9 to July 30. The results of the measurement are as follows. The daily temperature of the park plaza and waterside were found to be 2.7℃ and 2.9℃ lower than the roadside and 5.5℃ and 7.4℃ lower than the roadside from 10:00 to 16:00. In addition, the Universal Thermal Climate Index (UTCI) measurement was applied to measure the thermal comfort at each point. In the average daily analysis, a significant difference was found between the park plaza, the waterside, and the roadside, and a greater difference was found between 10:00 to 16:00. Also, although there was no significant difference due to the weather condition, a statistically significant difference was also found in the average PM10 and CO2 concentrations. It is found to be higher in the order from the roadside, park plaza, and waterside for PM10 concentration and park plaza, roadside, and waterside for CO2. In sum, although the difference in measured microclimate data and thermal comfort index results were different depending on the time and weather conditions at the three points, the park plaza and waterside, which are located inside the park, showed improved thermal comfort conditions and lower temperatures than the roadside outside the park.

Revise the Value of Simulation on Thermal Performance Depending on Air-tightness Performance Classified by Opening Type of Windows (창의 개폐방식별 기밀성능에 따른 단열성능 시뮬레이션 보정치 산출)

  • Lee, Jin-Sung;Cho, Soo;Sohn, Jang-Yeul
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.4
    • /
    • pp.68-75
    • /
    • 2008
  • The purpose of this research is revise the value yield to compensate of measure the difference between computer simulation and the measurement value on the two methods which can calculates thermal performance. The way is need to understand about thermal performance, air tightness, simulations and comparisons of analysis to influence the value of each identified. The opening type of the windows and doors to be used at the analysis are T/T, L/S and SL Different condition of the windows and doors excluded except the opening type. Each of the four samples was selected by the way of opening. Result of the analysis of the difference between measurement and simulation are that T/T approach 5.3%, L/S approach 15.7%, SL approach 21% and the more air-tightness guarantees less difference of the numerical value. Each compensation value calculates by the correlation regression analysis and the air-tightness data. After the compensation of the resulting difference in T/T, L/S, SL indicate 5.4%, 2.5%, 1.0% respectively.

Thermal Performance Evaluation at corners of the External wall of Modern New Han-oks using Temperature Difference Ratio inside (내표면 온도차 비율(TDRi) 분석을 통한 현대 신한옥 외벽 모서리 부위 단열성능 평가)

  • Lee, Ju-Yeob;Song, Min-Jeong;Lee, Tai-Gang;Kim, Sun-Woo;Cheon, Deuk-Youm
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.103-112
    • /
    • 2016
  • Recently, many New Han-oks have been constructing in all over the country to popularize as a type of green house. But, achievement of thermal performance of external wall is still the very important issue to become popular. Purpose: The purpose of this study is to verify the thermal performance level of modern New Han-ok through Temperature Difference Ratio inside(TDRi) analysis at corners of the external wall in Han-ok. Method: To achieve this goal, measurements were carried out in 12 Han-oks(experimental mock-up(1), exhibition Han-ok(1), happy village Han-oks(10)) by taking a infra-red thermography using thermal video system. Following are analysis items about connection joint between wall and wood columns of external wall conditions; the part between external wall and external wall(2D), external wall and ceiling(or floor)(2D), 2 external walls and ceiling(or floor)(3D) and so on. Result: It was analyzed that the probability of condensation at most of connection joint appear high and TDRi of 3D corners is higher than that of 2D corners in general. It means that the development of construction techniques about connection joint between wood columns and external wall is still required. The results of this study may be used to improve the construction technology of new Han-ok and as a basis for the specifying the desired thermal comfort environment of dwelling.

Thermal-mechanical Fatigue Life Prediction of 12Cr Forged Steel Using Strain Range Partitioning method (변형률분할법에 의한 12Cr 단조강의 열피로 수명예측)

  • 하정수;옹장우;고승기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1192-1202
    • /
    • 1994
  • Fatigue behavior and life prediction were presented for thermal-mechanical and isothermal low cycle fatigue of 12Cr forged steel used for high temperature applications. In-phase and out-of-phase thermal-mechanical fatigue test at 350 to 600.deg. C and isothermal low cycle fatigue test at 600.deg. C were conducted using smooth cylindrical hollow specimen under strain-control with total strain ranges from 0.006 to 0.015. Cyclic softening behavior was observed regardless of thermal-mechanical and isothermal fatigue tests. The phase difference between temperature and strain in thermal-mechanical fatigue resulted in significantly shorter fatigue life for out-of-phase than for in-phase. The difference in fatigue lives was dependent upon the magnitudes of inelastic strain ranges and mean stresses. Increase in inelastic strain range showed a tendency of intergranular cracking and decrease in fatigue life, especially for out-of-phase thermal-mechanical fatigue. Thermal-mechanical fatigue life prediction was made by partitioning the strain ranges of the hysteresis loops and the results of isothermal low cycle fatigue tests which were performed under the combination of slow and fast strain rates. Predicted fatigue lives for out-of-phase using the strain range partitioning method showed an excellent agreement with the actual out-of-phase thermal-mechanical fatigue lives within a factor of 1.5. Conventional strain range partitioning method exhibited a poor accuracy in the prediction of in-phase thermal-mechanical fatigue lives, which was quite improved conservatively by a proposed strain range partitioning method.

Thermal Shock Resistance and Thermal Expansion Behavior of $Al_2TiO_5$ Ceramics

  • Kim, Ik-Jin
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 2000.06a
    • /
    • pp.179-193
    • /
    • 2000
  • Aluminium titanate (Al₂TiO5) with an excellent thermal shock resistant and a low the expansion coefficient was obtained by solid solution with MgO, SiO₂, and ZrO₂ in the Al₂TiO5 lattice or in the grain boundary solution through electrofusion in an arc furnace. However, these materials have low mechanical strength due to the presence of microcracks developed by a large difference in thermal expansion coefficients along crystallographic axes. Pure Al₂TiO5 tends to decompose into α-Al₂O₃ and TiO₂-rutile in the temperature range of 750-1300℃ that rendered it apparently useless for industrial applications. Several thermal shock tests were performed: Long therm thermal annealing test at 1100℃ for 100h; and water quenching from 950 to room temperature (RT). Cyclic thermal expansion coefficients up to 1500℃ before and after decomposition tests was also measured using a dilatometer, changes in the microstructure, thermal expansion coefficients, Young's modulus and strengths were determined. The role of microcracks in relation to thermal shock resistance and thermal expansion coefficient is discussed.

  • PDF

(A)Study on Apartment Insulation Status and Insulation reinforcement Application (공동주택의 단열현황 조사 및 단열보강 적용방안에 관한 연구)

  • Jung, Ui-In;Kim, Bong-Joo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.226-227
    • /
    • 2015
  • This research is to measure and analyze the thermal performance of the apartment structure and to evaluate and establish standards of thermal insulation defect in order to make the basic data necessary for determining the degree of the thermal performance degradation and for repairing and reinforcing the exterior wall of the existing apartment. The following conclusions could be derived thorough the investigation of outer wall temperature distribution and the insulation assesment experiments using a model of specimens for the apartment houses' outer walls. It was confirmed that for the thermal performance through the insulating material thicknesses 5cm, 8cm in walls, the thermal insulation thickened by 3cm, from 5cm to 8cm, but that the actual temperature difference reached only about 1 ~ 2℃. This implies that the thermal performance improvement using the thermal insulation in walls is not significant and that it is difficult to insulate the thermal bridge area.

  • PDF

Hydrate Heat Analysis for the Determination of Optimized Thickness in Mass Concrete (매스 콘크리트의 적정 타설높이 산정을 위한 수화열 해석)

  • 신성우;이광수;유석형;김선호;황동규;박기홍
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.385-390
    • /
    • 2001
  • The thermal crack in mass concrete is mainly due to the difference of concrete temperature, which is generated by hydration heat of cement. As the thickness of mat foundation increases, the difference of temperature becomes bigger. The purpose of this study is to estimate the optimum placing depth. The temperature of real mat foundation was observed and the thermal analysis by Finite Element Method was executed. Finally, the crack index according to the placing depth was estimated.

  • PDF