• 제목/요약/키워드: Thermal condition

검색결과 3,159건 처리시간 0.03초

내연기관 피스톤의 열부하 해석을 위한 경제조건 설정에 관한 연구 (A Study on Boundary Conditions of Piston Thermal Loading Analysis in Internal Combustion Engines)

  • 정동수;조용석;최헌오;이진형
    • 대한기계학회논문집
    • /
    • 제12권3호
    • /
    • pp.528-533
    • /
    • 1988
  • 본 연구에서는 피스톤의 온도분포 및 열변형을 유한요소법에 의해 분석할 경 우 입력 데이타로 주어질 경계조건은 Li가 사용한 열저항 회로법을 근거로 하여 여기 에 경험치를 부여하는 방법으로 초기 설정치를 구하고, 또 전해질 탱크 상사법에 의한 실험적인 방법으로 결과를 구하여서 두 결과를 비교 검토하고자 한다.

예압과 냉각조건에 따른 고주파 모터 내장형 주축계의 열특성 (Thermal Characteristics of the High Frequency Motor Spindle according to the Bearing Preloads and Cooling Conditions)

  • 최대봉;김수태;정성훈;김진한;김용기
    • 한국공작기계학회논문집
    • /
    • 제14권6호
    • /
    • pp.31-36
    • /
    • 2005
  • Use of the high frequency motor spindles are increasing for the high speed machine tools recently. The important problem in the high speed spindles is to reduce and minimize the thermal effect by the motor and ball hearings. Thermal characteristics according to the bearing preload and spindle cooling are studied for the spindle with the oil mist lubrication and high frequency motor. Temperature distribution and thermal displacement according to the spindle speed, preload and flow rate are measured. Temperature distribution and thermal displacement of the high speed spindle system can be estimated reasonably by using the three dimensional model through the finite element method. The results of analysis are compared with the measured data. This study supports thermal optimization and find out more effective cooling condition. This paper show that the suitable preload and spindle cooling are very effective to minimize the thermal effect by the motor and ball bearings.

에폭시 경화물 DSC에 의한 유리전이 온도 측정의 분석조건 의존성 (The Effect of DSC Analysis Condition on the Glass Transition Temperature of curred Epoxy This paper studies on the effect of DSC(Differential Scanning Calorimeter) analysis condition on the glass transition temperature of silica filled epoxy network polymer used for ultra-high voltage apparatus. The effects of temperature scanning rate specimen size and gas flow rate on measured glass transition temperature have been studied in order to select optimum thermal analysis condition.)

  • 오무원;권혁삼
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 춘계학술대회 논문집
    • /
    • pp.30-33
    • /
    • 1994
  • This paper studies on the effect of DSC(Differential Scanning Calorimeter) analysis condition on the glass transition temperature of silica filled epoxy network polymer used for ultra-high voltage apparatus. The effects of temperature scanning rate specimen size and gas flow rate on measured glass transition temperature have been studied in order to select optimum thermal analysis condition.

  • PDF

스프링클러 소화설비의 열감지에 관한 연구 (A study on the thermal reponsivenes of automatic sprinklers)

  • 손봉세
    • 방재기술
    • /
    • 통권10호
    • /
    • pp.9-12
    • /
    • 1991
  • As the present idustry is devolping rapidly, automatic sprinklers continue to play a key role in modern fire protection. But the technical basis and methods of measurement of the thermal response of sprinklers are not studying in our country. Therefore, the purpose of this paper is to analyze the thermal response characteristics and condition parameters of automatic sprinkler head.

  • PDF

티탄과 알루미늄의 마찰용접에서 발생하는 잔류응력.소성변형 (Features of Residual Stress and Plastic Strain in Titanium/Aluminium Friction Welds)

  • 김유철;박정웅
    • Journal of Welding and Joining
    • /
    • 제18권5호
    • /
    • pp.84-89
    • /
    • 2000
  • Friction welding of titanium and aluminium is numerically modeled by the axisymmetric thermal elastic-plastic analysis. In titanium/aluminium friction welding, heat transfers into the titanium substrate to a distance of z=10(mm) on the side of the bondline and into the whole region of the aluminium substrate having the large thermal conductivity. Adjacent to the bondline, $^{\sigma}r\;and\;^{\sigma\theta}$ are tensile in the substrate whose thermal shrinkage is large, and are compressive in the substrate whose thermal shrinkage is small. $\sigma_z$ along the radial direction is large tensile at the periphery of the component. Plastic strain occurs only close to the bondline in the aluminium substrate. In the components of plastic strain, $\varepsilon^p_r\;and\;\varepsilon^p_{\theta}$ have positive values and $\varepsilon^p_r$ has large negative value. However, $\varepsilon^p_r$ is produced not because of the severity of the mechanical restraint condition, but on purpose to satisfy the condition of the volume constant. A plastic work is proposed as a measure to evaluate the mechanical severity. The plastic work is larger in the aluminium substrate than that in the titanium substrate. The mechanical condition is severer in the aluminium substrate.

  • PDF

가스분해 분석기법을 활용한 가스 전열 변압기의 상태 진단 연구 (A Study on the Condition Diagnosis for A Gas-insulated Transformer using Decomposition Gas Analysis)

  • 김아름;곽병섭;전태현;박현주
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.119-126
    • /
    • 2022
  • A growing number of gas-insulated transformers in underground power substations in urban areas are approaching 20 years of operation, the time when failures begin to occur. It is thus essential to prevent failure through accurate condition diagnosis of the given facility. Various solid insulation materials exist inside of the transformers, and the generated decomposition gas may differ for each gas-insulated equipment. In this study, a simulation system was designed to analyze the deterioration characteristics of SF6 decomposition gas and insulation materials under the conditions of partial discharge and thermal fault for diagnosis of gas-insulated transformers. Degradation characteristics of the insulation materials was determined using an automatic viscometer and FT-IR. The analysis results showed that the pattern of decomposition gas generation under partial discharge and thermal fault was different. In particular, acetaldehyde was detected under a thermal fault in all types of insulation, but not under partial discharge or an arc condition. In addition, in the case of insulation materials, deterioration of the insulation itself rapidly progressed as the experimental temperature increased. It was confirmed that it was possible to diagnose the internal discharge or thermal fault occurrence of the transformer through the ratio and type of decomposition gas generated in the gas-insulated transformer.

등온 경계 조건을 가지는 마이크로채널 히트 싱크의 열성능 해석을 위한 평균 접근법 (Averaging Approach for Microchannel Heat Sinks Subjected to the Uniform Wall Temperature Condition)

  • 김동권;김성진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1247-1252
    • /
    • 2004
  • The present paper is devoted to the modeling method based on an averaging approach for thermal analysis of microchannel heat sinks subjected to the uniform wall temperature condition. Solutions for velocity and temperature distributions are presented using the averaging approach. When the aspect ratio of the microchannel is higher than 1, these solutions accurately evaluate thermal resistances of heat sinks. Asymptotic solutions for velocity and temperature distributions at the high-aspect-ratio limit are alsopresented by using the scale analysis. Asymptotic solutions are simple, but shown to predict thermal resistances accurately when the aspect ratio is higher than 10. The effects of the aspect ratio and the porosity on the friction factor and the Nusselt number are presented. Characteristics of the thermal resistance of microchannel heat sinks are also discussed.

  • PDF

가용합금형 스프링클러 헤드의 열감도 특성에 관한 실험적 연구 (Experimental Study on the Characteristics of Thermal Sensitivity for Fusible Alloy Type Sprinkler Head)

  • 권오승;이진호
    • 한국화재소방학회논문지
    • /
    • 제9권1호
    • /
    • pp.20-29
    • /
    • 1995
  • The sprinkler head is a component of the sprinkler system intended to discharge water for automatic detection and extinguishment of fires. On this study, thermal characteristic values affecting the sensitivity of the fusible alloy type sprinkler head were obtained and analyzed under heated air stream condition which had constant temperature and velocity. The experiment was carried out under the forced convection condition with both the conductive heat loss considered and neglected. The thermal characteristic values of the sprinkler head were obtained in accordance with the material and shape of the heat responsive element and the conditions of the main body.

  • PDF

매스콘크리트 온도응력해석을 위한 온도분포함수 제안 (A Suggestion on Thermal Distributed Function for Thermal Stress Analysis in Mass Concrete)

  • 김현겸;김승익;한재호;이창수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.136-139
    • /
    • 2004
  • The domestic concrete standard specification(l999) reports roughly about heat transfer analysis and thermal stress analysis for mass concrete. Engineers cannot but choice after all numerical method such FEM, FDM to escape review. It seems to us that the specification is room for reconsideration because above methods are vary expensive and without popularity. This study suggests thermal distributed function in mass concrete. The function consists of two independent variables, curing time and depth. It's results have been tested a sensitivity for unit cement content, form condition, curing condition, and shape(depth, width). Results of the function are made a comparison with analytical values of MIDAS/CIVIL and a few measurement values. The researchers could meet with coherent and good results for variable cases.

  • PDF

고온고압 환경에서 케로신 연료의 물성치변화 및 분무특성연구 (Thermal Properties and Spray Characteristics of Kerosene Fuel at High Temperature and Pressure)

  • 변용우;손민;구자예
    • 한국분무공학회지
    • /
    • 제15권2호
    • /
    • pp.94-99
    • /
    • 2010
  • The object of this investigation is to study the thermal properties and spray characteristics of kerosene fuel in high temperature and pressure conditions. In order to investigate the thermal properties and spray characteristics, KIVA3 and SUPERTRAPP have been used at the same time. The thermal properties of kerosene has been calculated in high temperature and pressure condition using SUPERTRAPP. The study of spray characteristics has been conducted at both original properties of KIVA3 and calculated properties. The evaporation rate was increased in proportion to pressure when the calculated properties were used. However, the effect of pressure was not shown in the case of using original properties. So the calculated properties are more effective than original properties in high temperature and high pressure condition.