• Title/Summary/Keyword: Thermal analysis characteristics

Search Result 2,348, Processing Time 0.031 seconds

Growth of Polycrystalline 3C-SiC Thin Films using HMDS Single Precursor (HMDS 단일 전구체를 이용한 다결정 3C-SiC 박막 성장)

  • Chug, Gwiy-Sang;Kim, Kang-San;Han, Ki-Bong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.2
    • /
    • pp.156-161
    • /
    • 2007
  • This paper describes the characteristics of polycrystalline ${\beta}$ or 3C (cubic)-SiC (silicon carbide) thin films heteroepitaxailly grown on Si wafers with thermal oxide. In this work, the poly 3C-SiC film was deposited by APCVD (atmospheric pressure chemical vapor deposition) method using HMDS (hexamethyildisilane: $Si_{2}(CH_{3}_{6})$ single precursor. The deposition was performed under various conditions to determine the optimized growth conditions. The crystallinity of the 3C-SiC thin film was analyzed by XPS (X-ray photoelectron spectroscopy), XRD (X-ray diffraction) and FT-IR (fourier transform-infrared spectometers), respectively. The surface morphology was also observed by AFM (atomic force microscopy) and voids or dislocations between SiC and $SiO_{2}$ were measured by SEM (scanning electron microscope). Finally, depth profiling was invesigated by GDS (glow discharge spectrometer) for component ratios analysis of Si and C according to the grown 3C-SiC film thickness. From these results, the grown poly 3C-SiC thin film is very good crystalline quality, surface like mirror and low defect. Therfore, the poly 3C-SiC thin film is suitable for extreme environment, Bio and RF MEMS applications in conjunction with Si micromaching.

Heat Transfer Characteristics under Saturated Nucleate Pool Boiling for Various Heating Surface Angles using Heater with Artificial Cavity (인공 캐비티를 가진 히터를 이용한 가열면 경사각에 따른 포화상태 풀 핵비등 열전달 기초연구)

  • Kim, Jeong-Bae
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.4
    • /
    • pp.7-14
    • /
    • 2009
  • Nucleate pool boiling experiments with constant heat flux condition were performed using pure R11 and R113 for various surface angles under saturated pool condition. A circular heater of 1 mm diameter, with artificial cavity in the center, fabricated using MEMS technique and the high-speed controller were used to maintain the constant heat flux. Images of bubble growth were taken at 5,000 frames per second using a high-speed CCD camera. The bubble geometry was obtained from the captured bubble images. The effects of surface angles on the bubble growth behaviors were analyzed as dimensional scales for the initial and thermal growth regions. The parameters for the bubble growth behaviors were bubble radius, bubble growth rate, sliding velocity, bubble shape and advancing and receding contact angles. These phenomena require further analysis for various surface angles, but this study will provide good experimental data with constant heat flux boundary condition for such works.

Flow Distributions in the Channel of Plate Heat Exchanger Applied in Vacuum Evaporating Distiller System

  • Jin, Zhen-Hua;Park, Gi-Tae;Choi, Soon-Ho;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.389-394
    • /
    • 2008
  • Nowadays Plate Heat Exchanger (PHE) is widely used in different industries such as chemical, food and pharmaceutical process and refrigeration due to the efficient heat transfer performance, extreme compact design and efficient use of the construction material. In present work, PHE is applied in the fresh water generator system. Fresh water generators or desalinators are installed in ship to convert seawater to fresh water using heat from engines. PHE is an important part of a condensing or evaporating system. Among many of factors which should be concentrated on, the heat transfer and pressure drop is most important parts during sizing and rating the performance of PHE. Flow maldistribution is common but it will significantly reduce the heat exchanger performance. In this paper provide a overview of PHE cover basic of theory and conduct a numerical approach for flow distribution in plate channel. An experimental study on the performance of fresh water generator system which developed by plate heat exchanger will presented in future research. Thus, extensive experiment and analysis is required to study the thermal and fluid flow characteristics of PHE.

  • PDF

Preparation and Evaluation of Bupivacaine Microspheres by a Solvent Evaporation Method (II) (용매증발법에 의한 부피바카인 마이크로스피어의 제조 및 평가 (II))

  • 곽손혁;이시범;이종수;이병철;황성주
    • YAKHAK HOEJI
    • /
    • v.45 no.6
    • /
    • pp.623-633
    • /
    • 2001
  • Various bupivacaine-loaded microspheres were prepared using poly(d,1-lactide) (PLA) and poly(d,1-lactic-co-glycolide) (PLGA) by a solvent evaporation method for the sustained release of drug. The effects of process conditions such as drug loading, polymer type and solvent type on the characteristics of microspheres were investigated. The prepared microspheres were characterized for their drug loading, size distribution, surface morphology and release kinetics. Drug loading efficiency and yield of PLGA micro- spheres were higher than those of PLA microspheres. The prepared microspheres had an average particle size below 5${\mu}{\textrm}{m}$. The particle size range of microspheres was 1.65~2.24${\mu}{\textrm}{m}$. As a result of SEM, the particle size of PLA microspheres was smaller than that of PLGA microspheres. In morphology studies, microspheres showed a spherical shape and smooth surface in all process conditions. In thermal analysis, bupivacaine-loaded microspheres showed no peaks originating from bupivacaine. This suggested that bupivacaine base was molecular-dispersed in the polymer matrix of microspheres. The release pattern of the drug from microspheres was evaluated for 96 hours. The initial burst release of bupivacaine base decreased with increasing the molecular weight of PLGA, and the drug from microspheres released slowly. In conclusion, bupivacaine-loaded microspheres were successfully prepared from poly(d,1-lactide) and poly (d,1- lactic-co-glycolide) polymers with different molecular weights allowing control of the release rate.

  • PDF

A Review on the Regionalization Methodology for Core Inlet Flow Distribution Map

  • Lee, Byung-Jin;Jang, Ho-Cheol;Cheong, Jong-Sik;Baik, Se-Jin;Park, Young-Sheop
    • Nuclear Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.441-456
    • /
    • 2001
  • ABB-CE's regionalization methodology for the core inlet flow distribution map is reviewed. This methodology merges the test data of fuel assembly locations which are either in symmetry or strongly correlated with others. It increases the number of available test data for each regional flow factor It makes up effectively for the deficiency due to limited number of test data. It also contributes to making the core inlet flow distribution smoother not only locally but also over the entire core, and to relieving the impacts of test errors that may happen due to some do- calibrated local pressure measurement taps. As a result, the core inlet How distribution data becomes more statistically useful and thus the conservatism involved in handling the core inlet flow factors for the thermal margin analysis is expected to be reduced. Meanwhile, the regionalized map may lose the unique local characteristics in core inlet flow distribution too much. By an alternative approach introduced in the present work, it is shown that such a disadvantage can be mitigated somewhat if the engineering judgement is made more

  • PDF

Performance Analysis of Ammonia-Water Regenerative Rankine Cycles for Use of Low-Temperature Energy Source (저온 열원 활용을 위한 암모니아-물 재생 랭킨 사이클의 성능 해석)

  • Kim, Kyoung-Hoon;Han, Chul-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.15-22
    • /
    • 2011
  • It is a great interest to convert more energy in the heat source into the power and to improve the efficiency of power generating processes. Since the efficiency of power generating processes becomes poorer as the temperature of the source decreases, to use an ammonia-water mixture instead of water as working fluid is a possible way to improve the efficiency of the system. In this work performance of ammonia-water regenerative Rankine cycle is investigated for the purpose of extracting maximum power from low-temperature waste heat in the form of sensible energy. Special attention is paid to the effect of system parameters such as mass fraction of ammonia and turbine inlet pressure on the characteristics of system. Results show that the power output increases with the mass fraction of ammonia in the mixture, however workable range of the mass fraction becomes narrower as turbine inlet pressure increases and is able to reach 16.5kW per unit mass flow rate of source air at $180^{\circ}C$.

Analysis of Joule-heat Characteristics according to the DC-link Capacitor Film Geometrics (DC-link Capacitor필름 형상에 따른 Joule-heat특성 분석)

  • Jeon, Yong Won;Kim, Young Shin;Jeon, Euy Sik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.1
    • /
    • pp.42-48
    • /
    • 2020
  • As global warming accelerates, eco-friendly electric cars are being developed to reduce carbon dioxide emissions, and power conversion inverters are used to drive motors. Among inverter components, DC-link capacitor is heated by high current usage, which causes problems such as performance and life-saving of inverter. Although metal cases with good thermal performance have been used to solve this problem, it is difficult to apply them in practice due to insulation problems with other parts. In this paper, the Heat-Generation influence factor of DC-link capacitor is analyzed. Variables on heat-generation are set at 3 levels for film width, inductance, and film thickness. Box-Behnken to 13 tests using the design and minimal deviations, e.g. through the experiment three times by each level. The surface of the film k type by attaching the sensor current is measured temperature. Capacitance was set to a minimum level of 200 ㎌ and had a frequency of 16 kHz with Worst case, ambient temperature of 85℃ and a ripple current of 50 Ams was applied. The temperature at the measurement point was collected in the data logger after sampling at 1 minute intervals for 2 hours after saturation with the ambient temperature. This experiment confirmed that setup factors are correlated with heat-generation.

Verification Experiment and Calculation of Heating Load for a Test Space (시험공간에 대한 난방부하 실증실험 및 계산)

  • 현석균;홍희기;유호선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.2
    • /
    • pp.153-160
    • /
    • 2002
  • As a way to assess the reliability of programs for building energy analysis, verification experiment and calculation of heating load are simultaneously conducted for a well-defined test space. Experimental conditions are carefully set to minimize uncertainties associated with radiation heating, air change, infiltration, and room-to-room interaction. Dyna- mic load calculations using TRNSYS, which are performed for two different computation domains, rely on the energy rate control that represents inherent load characteristics of a space. The predicted instantaneous heating load favorably simulates the overall behavior the measured one, though the latter fluctuates much more rapidly than the former Comparison of the accumulative load between the experiment and calculations shows a close agreement within an engineering tolerance, regardless of the computation model. It is deduced from such findings that the present experimental results along with weather information can serve as a set of reference data for validating load calculation softwares from the users'standpoint. In order to enhance the completeness of this work, a complementary study on the cooling load for the same test space is highly recommended.

A Numerical Study on Performance of Air-to-Air Plastic Plate Heat Exchanger

  • Chung, Min-Ho;Yoo, Seong-Yeon;Han, Kyu-Hyun;Yoon, Hong-Ik;Kang, Hyoung-Chul
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.17 no.2
    • /
    • pp.52-60
    • /
    • 2009
  • The purpose of this research is to develop high efficiency plastic plate heat exchangers which can be substituted for conventional aluminum plate heat exchangers. Four simulation models of plastic plate heat exchangers are designed and simulated: that is, flat plate type, turbulent promoter type, corrugate type and dimple type heat exchanger. The flat plate type is designed as the reference model in order to evaluate how much thermal performance increases. The turbulent promoter type is fabricated with cylindrical-type vortex generators and rib-type turbulent promoters. The corrugate type is obtained from the conventional stainless steel compact heat exchangers, which are called the herringbone-type compact heat exchangers. The dimple type has a number of dimples on its surface. In this study, the flow and heat transfer characteristics of the plastic plate heat exchanger are investigated using numerical simulation and compared with experimental results. Numerical simulation is carried out using the FLUENT code. The flows are assumed as a three-dimensional, incompressible and turbulent model. The computational analysis and experimental results both show that the friction coefficient and Nu number is highest in the corrugate type. The tendency of numerical simulation results is in good agreement with that of the experimental results.

Suggestion of the Characteristics of Element Technology and the Standard Model through the Comparison of Domestic Zero-energy Houses (국내 에너지제로하우스 비교를 통한 요소기술 특성 및 표준 모델 제시에 관한 연구)

  • Lee, Chung-Kook;Lee, Jeong-Cheol;Kim, Sang-Su;Suh, Seung-Jik
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.2
    • /
    • pp.27-35
    • /
    • 2012
  • Five zero energy house models developed in Korea for the purpose of the energy performance were compared and analyzed in the study. The standard passive house model applying common technology and efficient energy performance elements was proposed. Standard passive house 5 models have been developed commonly aiming at 100% energy saving, applying high-performance and high-efficiency exterior thermal insulation, using 3 low-e coated window system, and targeting average 0.65 ACH to enhance privacy. Energy recovery ventilators and dry and cold radiant heating floor has been partially applied. Eco-design techniques such as the awning device, heat insulating door, using natural light have been used. Solar and geothermal systems as the application of renewable energy technologies have been commonly applied. And fuel cells were applied to a partial model. The standard model based on common technical elements and average performance of each element and obtained from five model analysis has been proposed in the study.