• Title/Summary/Keyword: Thermal analyses

Search Result 1,088, Processing Time 0.06 seconds

Estimation of Design Thermal Loads on PSC Box Girder Bridges by Statistical Extrapolation of Analytical Data (해석 데이터의 통계적 방법을 통한 PSC 박스거더교의 설계 온도 하중 추정)

  • 황의승;임창균;이영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.497-500
    • /
    • 2000
  • This paper describes the procedures to estimate for the design thermal loads on prestressed concrete box girder bridges on th basis of the extreme analysis of the temperature data obtained from long-term thermal analyses. Long-term thermal analyses using the environmental data for three years were conducted, and the extreme distributions of th thermal loads are then determined by the tail-equivalence method, and the thermal loads corresponding to selected return period are calculated. Finally, the results are compared to the specifications suggested in a current design code for thermal loads.

  • PDF

THERMAL ANALYSES AND VERIFICATION FOR HAUSAT-2 SMALL SATELLITE (HAUSAT-2 소형위성 열해석 검증 및 보드-레벨 열해석)

  • Lee Mi-Hyeon;Kim Dong-Woon;Chang Young-Keun
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.1
    • /
    • pp.39-54
    • /
    • 2006
  • HAUSAT-2 is nano satellite with 25kg mass being developed by Space System Research Lab. in Hnakuk Aviation University. This paper addresses HAUSAT-2 small satellite thermal analyses and its verification at satellite system, electronic box, and PCB levels. Thermal model which is used for system-level and box-level thermal analyses was verified and corrected through thermal vacuum/balance test. The new board-level thermal analysis methodology, modelling high-power dissipating EEE parts directly, was proposed. The proposed methodology has been verified with test results.

Analyses of temperature change of a u-bolometer in Focal Plane Array with CTIA bias cancellation circuit (CTIA 바이어스 상쇄회로를 갖는 초점면 배열에서 마이크로 볼로미터의 온도변화 해석)

  • Park, Seung-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2311-2317
    • /
    • 2011
  • In this paper, we study the temperature change of a ${\mu}$-bolometer focal plane array with a capacitive transimpedance amplifier bias cancellation circuit. Thermal analysis is essential to understand the performance of a ${\mu}$-bolometer focal plane array, and to improve the temperature stability of a focal plane array characteristics. In this study, the thermal analyses of a ${\mu}$-bolometer and its two reference detectors are carried out as a function of time. The analyses are done with the $30{\mu}m$ pitch $320{\times}240$ focal plane array operating of 60 Hz frame rate and having a columnwise readout. From the results, the temperature increase of a ${\mu}$-bolometer in FPA by an incident IR is estimated as $0.689^{\circ}C$, while the temperature increase by a pulsed bias as $7.1^{\circ}C$, which is about 10 times larger than by IR. The temperature increase of a reference detector by a train of bias pulses may be increased much higher than that of an active ${\mu}$-bolometer. The suppression of temperature increase in a reference bolometer can be done by increasing the thermal conductivity of the reference bolometer, in which the selection of thermal conductivity also determines the range of CTIA output voltage.

Characteristics of Mineral and Thermal Waters in South Korea (한국 온천수의 수질적 특성(I))

  • 임정웅
    • Journal of the Korean Professional Engineers Association
    • /
    • v.32 no.6
    • /
    • pp.60-67
    • /
    • 1999
  • 299 chemical analyses are used to study the characteristics of mineral and thermal waters in South Korea. Even though the concentration of chemical components in thermal waters are generally very low, mineral waters having components more than 1,000 ppm of dissolved total solid(TDS) are reached up to 19% total analyses data, In Germany, Japan or some other countries, mineral and thermal waters are detined not only by water temperature, but also by chemical components. The principle of Law in Japan in also almost same with the German regulations. However, the Law for thermal spring In Korea permit thermal water to be qualifiled only by water temperature. For including chemical characters into the regulations or Law of thermal spring, the limit values of TDS and other 9 micro components related to mineral and thermal waters was selected through this study.

Characteristics of Mineral and Thermal Waters in South Korea (II) (한국 온천수의 수질적 특성(II))

  • 임정웅
    • Journal of the Korean Professional Engineers Association
    • /
    • v.33 no.1
    • /
    • pp.75-82
    • /
    • 2000
  • 299 chemical analyses are used to study the characteristics of mineral and thermal waters in South Korea. Even though the concentration of chemical components in thermal waters are generally very low, mineral waters having components more than 1,000 ppm of dissolved total solid(TDS) are reached up to 1975 of total analyses data, In Germany, Japan or some other countries, mineral and thermal waters are defined not only by water temperature, but also by chemical components. The principle of Law in Japan is also almost same with the German regulations. However, the Law for thermal spring In Korea permit thermal water to be qualifiled only by water temperature. For including chemical characters into the regulations or Law of thermal spring, the limit values of TDS and other 9 micro components related to mineral and thermal waters was selected through this study.

  • PDF

Thermal and Dynamic Analyses of a Composite Optical Bench (복합재료 광학탑재 위성구조체의 열변형 및 동적특성)

  • Ahn, Jin-Hee;Kim, Cheol
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.161-164
    • /
    • 2005
  • This paper finds the optimal staking sequence of the satellite composite structures to minimize severe thermal deformations during their orbital operation using GAs and finite element analyses. Then, the optimal design is reinforced to endure the launch loads like high inertia and vibratory loads that are, usually, smaller than orbital loads induced by space environments. The thermal deformation of sandwich panels was minimized at the staking sequence of [$0_2$/90]s and that of composite strut was lowest at the angle of [0/${\pm}45$]s Also there was no buckling in the compressive loading. By vibration analysis, the natural frequencies of the composite components are much higher than aluminum structures and the expected stiffness condition is satisfied. Then, a composite optical bench was fabricated for tests and all analyses results were verified by structural testing. There were good correlations between two results.

  • PDF

Stress and Thermal Analyses of Pressure Housing of SMART CEDM (SMART제어봉구동장치의 압력용기에 대한 응력 및 열해석)

  • 조대희;유제용;김지호;김종인
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.04a
    • /
    • pp.343-350
    • /
    • 2002
  • The structural stability of pressure housing of SMART CEDM forming pressure boundary must be evaluated. In this paper, the stress and thermal analyses of the upper pressure housing of CEDM are performed for design pressure, hydraulic test pressure and thermal loading. Finite element and boundary condition were generated from the model which is made by I-DEAS program and the stress and thermal analyses were performed by ANSYS Program. The upper Pressure housing was analysed using 2D axisymmetric model because it is symmetry about an axis. The stress values obtained by analysis were compared with the stress intensity limit of ASME and KEPIC MNB standard.

  • PDF

Estimations of the C(t)-Integral in Transient Creep Condition for Pipe with Crack Under Combined Mechanical and Thermal Stress (I) - Elastic-Creep - (복합응력이 작용하는 균열 배관에 대한 천이 크리프 조건에서의 C(t)-적분 예측 (I) - 탄성-크리프 -)

  • Song, Tae-Kwang;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.9
    • /
    • pp.949-956
    • /
    • 2009
  • The C(t)-integral describes amplitude of stress and strain rate field near a tip of stationary crack under transient creep condition. Thus the C(t)-integral is a key parameter for the high-temperature crack assessment. Estimation formulae for C(t)-integral of the cracked component operating under mechanical load alone have been provided for decades. However, high temperature structures usually work under combined mechanical and thermal load. And no investigation has provided quantitative estimates for the C(t)-integral under combined mechanical and thermal load. In this study, 3-dimensional finite element analyses were conducted to calculate the C(t)-integral of elastic-creep material under combined mechanical and thermal load. As a result, redistribution time for the crack under combined mechanical and thermal load is re-defined through FE analyses to quantify the C(t)-integral. Estimates of C(t)-integral using this proposed redistribution time agree well with FE analyses results.

Thermal Stress Analysis and Flow Characteristics of a Bellows-Seal Valve for High Pressure and Temperature (고온.고압용 벨로우즈 실 밸브의 유동 특성 및 열응력 해석)

  • Kim, Kwang-Su;Lee, Jong-Chul;Kim, Youn-Jea
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.6 s.33
    • /
    • pp.40-46
    • /
    • 2005
  • Because of design and manufacturing costs, it is important to predict an expected life of bellows with component stresses of bellows as its design factors and material characteristics. In this study, numerical analyses are carried out to elucidate the thermal and flow characteristics of the bellows-seal gate and globe valves for high temperature (max. $600^{\circ}C$) and for high pressure (max. $104 kgf/cm^2$) conditions. Using commercial codes, FLUENT, which uses FVM and SIMPLE algorithm, and ANSYS, which uses FEM, the pressure and temperature fields are graphically depicted. In addition, when bellows have an axial displacement, thermal stress affecting bellows life is studied. The pressure and temperature values obtained from the flow analyses are adopted as the boundary conditions for thermal stress analyses. As the result of this study, we got the reasonable coefficients for valve and thermal stress for bellows, compared with existing coefficients and calculated values.

Tension/Heat/Thermal Deformation Analysis of a Cold Coiled Strip in Coiling Process (냉연 판재의 권취공정에 있어서 장력/열/변형 해석)

  • 정영진;이규택;강충길
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.05a
    • /
    • pp.39-43
    • /
    • 2002
  • A new model for heat transfer and thermal deformation analysis according to strip mm in coiling process has been proposed. Finite difference analyses for heat transfer of cold rolled coil have been carried out under various coiling tensions and strip crown using the equivalent thermal conductivity for the radial direction of cold rolled coil which is a function of strip thickness, surface characteristics and compressive pressure. The compressive pressure is calculated from a equation expressed as a function of hoop stress and coil tension considering strip mm obtained by experiment. Finite element method for thermal deformation of cold rolled coil has been performed to investigate the effects of the strip crown, the coil tension and temperature. From these analyses, it is found that the axial inhomogeneity of thermal deformation is increased as the strip crown, compressive pressure, and temperature drop in cold coiled strip increase.

  • PDF