• Title/Summary/Keyword: Thermal ablation

Search Result 174, Processing Time 0.029 seconds

Measurements of Ablations on Nozzle Throats of KL-3 Engines Using Image Analysis (영상분석을 통한 KL-3 엔진 노즐목 삭마량 측정)

  • 김영한;고영성;박성진;류철성;강선일;오승협
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.3
    • /
    • pp.1-7
    • /
    • 2003
  • In this research, it is intended to measure shape of the nozzle throat of the KL-3 engine, which is the main engine of the KSR-III rocket. For the purpose, an image-based method was invented to replace the 3D pointer, which is actually inaccessible to such large scale engines. As a result, our equipment showed satisfactory Performances. Analysing the results of experiments, we find that the pattern of ablation is determined by the spray pattern and that the process of thermal ablation phenomena can be categorized in three regimes - the first regime that the shape of nozzle throat is maintained and ablation is negligible, the second regime that saw-tooth form is developed and ablation is accelerated, and the third regime that the saw-tooth form is already established and the growth of ablation rate is reduced Also, we find that the ratio of area increase after 60 seconds combustion is +5.82% and conclude that the ratio is acceptable and satisfactory.

A Study on the Influence Factors for Ablation Rate of Graphite Nozzle Throat Insert (흑연 노즐목 삽입재의 삭마율에 미치는 영향 인자 연구)

  • Hahm, Heecheol;Kang, Yoongoo;Seo, Sangkyu
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.4
    • /
    • pp.12-20
    • /
    • 2017
  • The ablation characteristics of graphite nozzle throat insert was analyzed for the use in solid rocket propulsion system. The propulsion system was composed of three types of conventional nozzles, such as De-Laval type, blast tube type, and submerged type. Various kinds of propellants were used in ten kinds of propulsion system that had different shapes with each other. Total forty eight tests were performed. From the results of the analysis, it was found that the ablation rate was increased for the higher average chamber pressure and the higher oxidizer mole fraction. A useful correlation for nozzle throat ablation rate was developed in terms of the chamber pressure, oxidizer mole fraction, and throat size. The calculated ablation rates from the correlation showed agreement within ${\pm}0.10mm/s$ with the experimentally determined values.

Impact of Energy and Access Methods on Extrahepatic Tumor Spreading and the Ablation Zone: An Ex vivo Experiment Using a Subcapsular Tumor Model

  • Jin Sil Kim;Youngsun Ko;Hyeyoung Kwon;Minjeong Kim;Jeong Kyong Lee
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.580-588
    • /
    • 2019
  • Objective: To evaluate the impact of energy and access methods on extrahepatic tumor spreading and the ablation zone in an ex vivo subcapsular tumor mimic model with a risk of extrahepatic tumor spreading. Materials and Methods: Forty-two tumor-mimics were created in bovine liver blocks by injecting a mixture of iodine contrast material just below the liver capsule. Radiofrequency (RF) ablations were performed using an electrode placed parallel or perpendicular to hepatic surface through the tumor mimic with low- and high-power protocols (groups 1 and 2, respectively). Computed tomography (CT) scans were performed before and after ablation. The presence of contrast leak on the hepatic surface on CT, size of ablation zone, and timing of the first roll-off and popping sound were compared between the groups. Results: With parallel access, one contrast leak in group 1 (1/10, 10%) and nine in group 2 (9/10, 90%) (p < 0.001) were identified on post-ablation CT. With perpendicular access, six contrast leaks were identified in each group (6/11, 54.5%). The first roll-off and popping sound were significantly delayed in group 1 irrespective of the access method (p = 0.002). No statistical difference in the size of the ablation zone of the liver specimen was observed between the two groups (p = 0.247). Conclusion: Low-power RF ablation with parallel access is proposed to be effective and safe from extrahepatic tumor spreading in RF ablation of a solid hepatic tumor in the subcapsular location. Perpendicular placement of an electrode to the capsule is associated with a risk of extrahepatic tumor spreading regardless of the power applied.

Ablation rate study using short pulsed laser subjected to Alumina medium (알루미나 세라믹 소재의 초단파 레이저 어블레이션량 연구)

  • Kim, Kyunghan;Park, Jinho
    • Laser Solutions
    • /
    • v.18 no.4
    • /
    • pp.17-22
    • /
    • 2015
  • In this paper, ablation rate of $Al_2O_3$ ceramics by femtosecond laser fluence is derived with experimental method. The automatic three axis linear stage makes laser optics to move with high spatial resolution. With 10 times objective lens, minimal pattern width of $Al_2O_3$ is measured in the focal plane. Ablated surface area is shown as linear tendency increasing number of machining times with various laser power conditions. Machining times is most sensitive condition to control $Al_2O_3$ pattern width. Also, the linear increment of pattern width with laser power change is investigated. In high machining speed, the ablation volume rate is more linear with fluence because pulse overlap is minimized in this condition. Thermal effect to surrounding medium can be minimized and clean laser process without melting zone is possible in high machining speed. Ablation volume rate decelerates as increasing machining times and multiple machining times should be considered to achieve proper ablation width and depth.

Numerical Analysis of 1-D Ablation and Charring of a Composite Heat Insulator Using Finite Analytic Method (유한해석법을 이용한 조합 내열부품의 1차원 삭마 및 숯층 형성 해석)

  • 함희철;배주찬;이태호;전광민;이진호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.943-951
    • /
    • 1992
  • The objectives of this study are to analyse the thermal response behavior occurring in the charring ablative material more realistically by considering ablation and char phenomena occurring in several material layers, and to increase the reliability of thermal analysis by being able to get stable solutions through using the finite analytic method. A program has been developed to predict the temperature distribution, ablation thickness, char thickness, ablation velocity and char velocity by solving non-linear one-dimensional heat conduction equation. Results of calculation were compared with results of published papers. From this compariosn this program was proved to be a very good tool for thermal design and analysis of charring ablative materials used in the rocket propulsion system.

Thermomechanical Coupled Analysis of Carbon/phenolic Composite Structures in Reentry Environments (재진입 환경의 탄소/페놀릭 복합재 구조물의 열기계적 연계 해석)

  • Son, Myeong Jin;Shin, Eui Sup
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.6
    • /
    • pp.414-421
    • /
    • 2019
  • In this paper, thermomechanical coupled analysis of carbon/phenolic composites structures in reentry environment was performed. The interface of thermomechanical coupled analysis was constructed using commercial software. The governing equations of temperature and displacement fields were considered to simulate change of physical behavior due to pyrolysis and ablation effects. The results of thermomechanical coupled analysis were compared with the results of ablation test using arc-heated wind tunnel. Also, the structural stability of reentry capsule was analyzed using the analysis interface. The excellent ablation characteristics and thermal protection effects of the carbon/phenolic composites were confirmed and the constructed analysis interface can be effectively used to perform thermal protection system design.

Power Dependence on Formation of Polyynes by Laser Ablation in Water

  • Park, Young Eun;Shin, Seung Keun;Park, Seung Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.4
    • /
    • pp.1039-1042
    • /
    • 2013
  • Polyynes were prepared by liquid laser ablation of a graphite target in deionized water at various physical conditions such as laser power (20 and 40 mJ/pulse) and ablation wavelengths (355, 532, and 1064 nm). The effects of physical parameters on the linear carbon chain length were examined by analyzing the densities of polyynes with different carbon numbers ($C_6H_2$, $C_8H_2$, and $C_{10}H_2$) as well as their branching ratios. We concluded the photophysical processes turned out to play a more significant role than thermal ones in the formation of polyynes.

The Solvent Effects on the Formation of Polyynes by Laser Ablation

  • Park, Young-Eun;Shin, Seung-Keun;Park, Seung-Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.7
    • /
    • pp.2439-2442
    • /
    • 2012
  • In order to explore the effects of the solvent on the formation rate of polyynes, we investigated the absorption spectra of polyynes obtained by laser ablation of a graphite target in different solvents at 1064 nm. Polyynes so produced were confirmed by the Raman band around $2200cm^{-1}$ which corresponds to the carbon triple bonds. The production of polyynes by laser ablation turned out to be significantly affected by the ratio of the hydrogen and carbon atoms in the solvent molecule. No clear correlations were observed in the formation of polyynes for other properties of the solvent such bond dissociation energy, thermal conductivity, and total mass of hydrogen atoms per volume of solvent.

Comparative Tissue Ablation Study between 532 and 980 nm (가시광선과 근적외선 파장을 이용한 조직 제거 연구)

  • Kang, Hyun Wook;Oh, Junghwan
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.3
    • /
    • pp.108-112
    • /
    • 2012
  • In this paper, two wavelengths mainly used for laser prostatectomy have been quantitatively compared: 532 and 980 nm. Two lasers at 40 W were employed to ablate bovine liver in vitro. Ablation performance was evaluated in light of number of sweeps, ablation volume, and coagulative necrosis. 532 nm yielded up to four times higher ablation efficiency than 980 nm. Regardless of wavelength, ablation rate per sweep decreased with the number of sweeps. 532 nm generated relatively deeper ablation craters along with thinner coagulation whereas 980 nm created superficial tissue ablation with up to 2 mm thick coagulative necrosis. Due to higher light absorption and effective thermal confinement, 532 nm induced more efficient tissue ablation with a smaller coagulative necrotic zone. The current study demonstrated that 532 nm could be a more ideal wavelength for laser prostatectomy, and the future in vivo investigations will confirm these findings.

Prediction Method for Thermal Destruction of Internal Insulator in Solid Rocket Motor (고체추진기관 연소관단열재의 열파괴 예측기법)

  • Ji-Yeul Bae;In Sik Hwang;Yoongoo Kang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.27 no.1
    • /
    • pp.9-16
    • /
    • 2023
  • This paper investigated the method to predict a thermal response of internal insulation in a solid rocket motor considering both thermal decomposition and ablation. Changes in properties due to the thermal decomposition, swelling of char layer and movement of decomposition gases inside the material were considered during a modeling. And radiative/convective heat flux from the exhaust gas were applied as boundary conditions, while the chemical ablation of the material surface is modeled with algebraic equations. Test SRM with thermocouples was solved for a validation purpose. The results showed that predicted temperatures have identical trends and values compared to the experimental values. And an error of predicted thermal destruction depth was around 0.1 mm.