• 제목/요약/키워드: Thermal Spectrum

검색결과 400건 처리시간 0.023초

PET 말단에 대한 인계난연제의 라디칼계 부가반응 (1) - 비스페놀에이비스다이페닐포스페이트의 반응 - (Radical Addition Reaction of Phosphorous based Flame Retardant with End Groups of PET (1) - Reaction of Bisphenol A bis(diphenyl phosphate) -)

  • 김민관;김한도
    • 한국염색가공학회지
    • /
    • 제24권1호
    • /
    • pp.33-38
    • /
    • 2012
  • In this study, to increase flame retardation of poly(ethylene terephthalate) (PET) in burning, bisphenol A bis(diphenyl phosphate) (BDP), a well known flame retardant containing phosphorous, was reacted on end groups of PET by radical pathway. End-capping mechanism of PET with BDP was suggested and confirmed by spectroscopic and thermal analysis. From 400 MHz $^{31}P$ solid state FT-NMR spectrum of end-capped PET (PET-BDP), phosphorus spectra peak in BDP was found at ca. -20 ppm. Furthermore, P-C bond stretching vibration peaks were found ca. $600cm^{-1}$ in FT-IR spectrums of PET-BDP. These results showed that BDP can be chemically added on end groups of PET by our method. Thermal characteristics of pure PET (pPET) and PET-BDP were measured and evaluated by TGA analysis. There was not significant changes in thermal characteristics of PET-BDP compared to that of pPET.

혼합배관 내의 열 경계층 이동으로 인한 고주기 온도요동에 관한 연구 (A Study on High Cycle Temperature Fluctuation Caused by Thermal Striping in a Mixing Tee Pipe)

  • 김석범;박종호
    • 한국유체기계학회 논문집
    • /
    • 제10권5호
    • /
    • pp.9-19
    • /
    • 2007
  • Fluid temperature fluctuations in a mixing tee pipe were numerically analyzed by LES model in order to clarify internal turbulent flows and to develope an evaluation method for high-cycle thermal fatigue. Hot and cold water with an temperature difference $40^{\circ}C$ were supplied to the mixing tee. Fluid temperature fluctuations in a mixing tee pipe is analysed by using the computational fluid dynamics code, FLUENT, Temperature fluctuations of the fluid and pipe wall measured as the velocity ratio of the flow in the branch pipe to that in the main pipe was varied from 0.05 to 5.0. The power spectrum method was used to evaluate the heat transfer coefficient. The fluid temperature characteristics were dependent on the velocity ratio, rather than the absolute value of the flow velocity. Large fluid temperature fluctuations were occurred near the mixing tee, and the fluctuation temperature frequency was random. The ratios of the measured heat transfer coefficient to that evaluated by Dittus-Boelter's empirical equation were independent of the velocity ratio, The multiplier ratios were about from 4 to 6.

옻칠의 경화에 관한 연구 (A Study on Curing of Commercially Available Chines Urushiol)

  • 김영백;박덕수
    • 자연과학논문집
    • /
    • 제8권2호
    • /
    • pp.21-26
    • /
    • 1996
  • 시중에서 판매하는 중국산 옻칠을 그대로 혹은 유기용매에 녹는 부분과 녹지 않는 부분으로 분리하고 각각의 경화현상을 연구하였다. 그대로 사용하는 경우에는 상온에서 수분이 포화된 상태에서 경화를 관찰하였으며 유기용매로 분리한 부분의 경화는 섭씨 $100^{\circ}C$$150^{\circ}C$에서 경화를 관찰하였다. 서로 다른 방법으로 얻어낸 도막의 성질을 서로 비교하였으며 옻 중 유기용매에 녹는 부분과 1,6-diisocyanohexane, toluendiisocyanate(TDI)를 공중합하였을 때 얻어지는 도막과 다른 도막과의 성질로 비교하였다. 가열하여 형성된 도막은 매우 깨어지는 성질(취성)이 매우 높았으며 자연상태로 경화된 도막에 비하여 친수성이 낮았다. Diisocyanate를 사용하지 않은 경우에는 경화에 산소가 필수적이어서 오랜 시간이 지나도 내부는 경화가 되지 않았다.

  • PDF

FBG를 이용한 파장가변 형 전광 필터의 고온 특성에 관한 연구 (A Study on the High-Temperature Characteristics of a Tunable All-Optical Filter Using Fiber Bragg Grating)

  • 손용환;양세훈;김현승;한상국
    • 전기전자학회논문지
    • /
    • 제14권4호
    • /
    • pp.263-269
    • /
    • 2010
  • 본 논문에서는 Germanium 및 Germanium과 Boron이 도핑 된 광섬유의 FBG를 이용한 파장가변 형 전광 필터의 고온 특성을 고찰하고, 온도 변화에 대한 파장가변 형 FBG 필터의 반사도, 선폭, 정규화 굴절률 차의 특성 변화를 수치해석을 통해 비교 고찰 하였다. 굴절률 차의 변화에 따른 FBG 필터의 반사 스펙트럼은 온도 안정성에 영향을 받으며, Germanium이 도핑 된 광섬유의 FBG 필터가 Germanium과 Boron이 도핑 된 광섬유의 FBG 필터보다 온도변화에 더 안정성을 가짐을 알 수 있다. 또한 $500^{\circ}C$ 까지의 온도에 대해서는 두 가지 모두 필터로서 온도변화에 안정성을 가짐을 알 수 있다.

LCD Color Filter용 Cy3 염료의 제조 및 특성 연구 (Preparation and Characterization of Cy3 Dye for LCD Color Filter)

  • 이상동;현동균;정연태
    • 한국전기전자재료학회논문지
    • /
    • 제29권1호
    • /
    • pp.35-39
    • /
    • 2016
  • In this research, we focused on the improvement of cy3 dye's characteristics for LCD color filter. Solubility and thermal stability are main characteristics of dyes for LCD color filter. We performed experiment to change counter cation of cy3 dyes with alkoxy substituent for these purposes. These cy3 dyes (1b~5b) were prepared through the synthetic procedure of three steps. The synthesized new cy3 dyes were charaterized by using NMR, FT-IR, UV/Vis spectroscopy, and TGA. These cy3 dyes showed purple color and maximum absorption wavelength (${\lambda}_{max}$) in the range of 578~590 nm in UV/Vis spectrum. We confirmed that solubility and thermal stability of cy3 dyes were dependent on the structure of counter cation. Cy3 dyes with alkoxy substituent have good solubility in organic solvents such as dichloromethane, methanol, and acetone. Especially, Cy3 dye with 4-nitrobenzyl counter cation (5b) gave excellent solubility characteristics.

3-성분 종입자법으로 제조된 ZnO-Varistor의 열화기구 (Degradation Mechanism of the ZnO-Varistor Fabricated with the content of a 3-Composition Seed grain)

  • 장경욱;박춘배;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1992년도 춘계학술대회 논문집
    • /
    • pp.97-100
    • /
    • 1992
  • The Degradation mechanism of the ZnO-varistor fabricated with the content of a 3-Composition seed grain is discussed using the method of Thermally Stimulated Current (TSC). The spectra of TSC is measured in the temperature range of -130~270$^{\circ}C$ with a various forming electric fields E$\sub$f/, temperature T$\sub$f/ time tf, and a various rising rate of temperature. It is observed that there are appeared the peaks of ${\alpha}$, ${\alpha}$$_2$, ${\beta}$ and ${\gamma}$from high temperature in a TSC spectrum. It seems that ${\alpha}$$_1$ peak is due to thermal depolarization of donor ions forming the space charge in the depletion layer, and ${\alpha}$$_2$peak is due to the detrapping of trapped electrons in deep trap level of intergranular layer, and ${\beta}$ peak is due to the thermal exciting of carrier existing in the donor level of grain itself, and ${\gamma}$ peak is due to the thermal exciting of trapped carrier in all shallow trap site randomly distributed in the inner of sample and/or a intrinsic impurity existing in it.

  • PDF

Investigations on PD Characteristics of Thermal aged Palm and Corn Oil for Power Transformer Insulation Applications

  • Senthilkumar, S.;Karthik, B.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1660-1669
    • /
    • 2014
  • Partial discharge (PD) detection plays a major role in the life time assessment of liquid insulation in power transformers. Many research works are being carried out to replace conventional mineral oil insulation in transformers by vegetable oils. It is necessary to understand the PD characteristics of vegetable oils before recommending them as an alternate for mineral oil. In this paper, the breakdown strength and PD characteristics of palm and corn oil were investigated in both unaged and thermally aged conditions. Laboratory experiments were performed as per IEC test procedures. PD signals were measured using wide band detection system. Phase resolved PD pattern of vegetable oils and mineral oil were compared. Effect of increase in voltage stress on the PD pattern of palm and corn oil were studied. Time and frequency domain analysis of PD pulses at needle-plane electrode configuration was carried out. Statistical analysis of PD pattern i.e. skewness and shape parameter variations with respect to applied thermal stress were also carried out. From the results, it is observed that palm and corn oils have better breakdown strength and PD characteristics even under long-term thermal stress and hence they can be used for power transformer applications.

Optical System Design for Thermal Target Recognition by Spiral Scanning [TRSS]

  • Kim, Jai-Soon;Yoon, Jin-Kyung;Lee, Ho-Chan;Lee, Jai-Hyung;Kim, Hye-Kyung;Lee, Seung-Churl;Ahn, Keun-Ok
    • Journal of the Optical Society of Korea
    • /
    • 제8권4호
    • /
    • pp.174-181
    • /
    • 2004
  • Various kinds of systems, that can do target recognition and position detection simultaneously by using infrared sensing detectors, have been developed. In this paper, the detection system TRSS (Thermal target Recognition by Spiral Scanning) adopts linear array shaped uncooled IR detector and uses spiral type fast scanning method for relative position detection of target objects, which radiate an IR region wavelength spectrum. It can detect thermal energy radiating from a 9 m-size target object as far as 200 m distance. And the maximum field of a detector is fully filled with the same size of target object at the minimum approaching distance 50 m. We investigate two types of lens systems. One is a singlet lens and the other is a doublet lens system. Every system includes one aspheric surface and free positioned aperture stop. Many designs of F/1.5 system with ${\pm}5.2^{\circ}$ field at the Efl=20, 30 mm conditions for single element and double elements lens system respectively are compared in their resolution performance [MTF] according to the aspheric surface and stop position changing on their optimization process. Optimum design is established including mechanical boundary conditions and manufacturing considerations.

SIMULATED AP1000 RESPONSE TO DESIGN BASIS SMALL-BREAK LOCA EVENTS IN APEX-1000 TEST FACILITY

  • Wright, R.F.
    • Nuclear Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.287-298
    • /
    • 2007
  • As part of the $AP1000^{TM}$ pressurized water reactor design certification program, a series of integral systems tests of the nuclear steam supply system was performed at the APEX-1000 test facility at Oregon State University. These tests provided data necessary to validate Westinghouse safety analysis computer codes for AP1000 applications. In addition, the tests provided the opportunity to investigate the thermal-hydraulic phenomena expected to be important in AP1000 small-break loss of coolant accidents (SBLOCAs). The APEX-1000 facility is a 1/4-scale pressure and 1/4-scale height simulation of the AP1000 nuclear steam supply system and passive safety features. A series of eleven tests was performed in the APEX-1000 facility as part of a U.S. Department of Energy contract. In all, four SBLOCA tests representing a spectrum of break sizes and locations were simulated along with tests to study specific phenomena of interest. The focus of this paper is the SBLOCA tests. The key thermal-hydraulic phenomena simulated in the APEX-1000 tests, and the performance and interactions of the passive safety-related systems that can be investigated through the APEX-1000 facility, are emphasized. The APEX-1000 tests demonstrate that the AP1000 passive safety-related systems successfully combine to provide a continuous removal of core decay heat and the reactor core remains covered with considerable margin for all small-break LOCA events.

X-RAY PROPERTIES OF THE PULSAR PSR J0205+6449 IN 3C 58

  • Kim, Minjun;An, Hongjun
    • 천문학회지
    • /
    • 제54권1호
    • /
    • pp.1-8
    • /
    • 2021
  • We report X-ray timing and spectral properties of the pulsar PSR J0205+6449 measured using NuSTAR and Chandra observatories. We measure the pulsar's rotation frequency ν = 15.20102357(9) s-1 and its derivative $\dot{\nu}=-4.5(1){\times}10^{-11}\;s^{-2}$ during the observation period, and model the 2-30 keV on-pulse spectrum of the pulsar with a power law having a photon index Γpsr = 1.07 ± 0.16 and a 2-30 keV flux F2-30 keV = 7.3±0.6 × 10-13 erg cm-2 s-1. The Chandra 0.5-10 keV data are analyzed for an investigation of the pulsar's thermal emission properties. We use thermal and non-thermal emission models to fit the Chandra spectra and infer the surface temperature T∞ and luminosity Lth of the neutron star to be T∞ = 0.5 - 0.8 MK and Lth = 1 - 5 × 1032 erg s-1. This agrees with previous results which indicated that PSR J0205+6449 has a low surface temperature and luminosity for its age of 800-5600 yrs.