• 제목/요약/키워드: Thermal Protection System

검색결과 175건 처리시간 0.024초

산화물 세라믹섬유를 이용한 재사용 열보호시스템용 경량 세라믹 단열소재의 제조 (Fabrication of Light-weight Ceramic Insulation Materials by Using Oxide Ceramic Fibers for Reusable Thermal Protection Systems)

  • 김성원;남민수;오윤석;남산;신재성;김현준;오범석
    • 한국분말재료학회지
    • /
    • 제29권6호
    • /
    • pp.477-484
    • /
    • 2022
  • Thermal protection systems (TPS) are a group of materials that are indispensable for protecting spacecraft from the aerodynamic heating occurring during entry into an atmosphere. Among candidate materials for TPS, ceramic insulation materials are usually considered for reusable TPS. In this study, ceramic insulation materials, such as alumina enhanced thermal barrier (AETB), are fabricated via typical ceramic processing from ceramic fiber and additives. Mixtures of silica and alumina fibers are used as raw materials, with the addition of B4C to bind fibers together. Reaction-cured glass is also added on top of AETB to induce water-proof functionality or high emissivity. Some issues, such as the elimination of clumps in the AETB, and processing difficulties in the production of reusable surface insulation are reported as well.

발전기 보호용 계자상실 계전기의 적용 분석 (Application Analysis for Loss of Excitation Relay of Generator Protection)

  • 오용택;박철원
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.322-326
    • /
    • 2014
  • Recently, the LOE(loss of excitation) incidents are occurred in domestic synchronous generator frequently, the synchronous generator protection system has been much attention for the LOE protection of the incidents that threats synchronous generators and power systems. This paper was showed the characteristics and practices of distance relay that widely used LOE protection relaying in generator. Firstly, the operating characteristics and the impedance locus for LOE of the generator protection were introduced. Even if the conventional simulation program is used for modeling, but it is difficult to implement a LOE modeling and simulation of synchronous generator. So, the LOE relay operation data collected from thermal power plant and nuclear power plant in real fields were analyzed. By reviewing the applications of GE Mho relays, the reliability of LOE for synchronous generator protection in domestic were improved.

상변화물질을 이용한 열방어체계의 수치해석 연구 (A numerical analysis of the PCM applied Thermal Protection System)

  • 오창묵;유영준;이형주;민성기
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.622-627
    • /
    • 2010
  • 본 논문은 내외부에 열원이 있는 시스템에 상변화물질(PCM, Phase Change Material)을 적용한 경우를 수치해석으로 분석한 것으로 컨넥터가 없는 경우와 있는 경우에 대하여 분석한 것이다. 각각의 경우에 $T_{max}$ 열원만 있을 경우와 $T_{max}$$710W/m^2$ 열원이 동시에 있을 경우가 고려되었다. 연구 결과 벽면에서의 열전달, 시간에 따른 PCM 온도변화 그리고 내부온도의 변화를 정리하였으며 그 결과 시스템의 구성품과 열전달 방향 및 열원의 종류에 따라 PCM의 잠열 시간이 달라진다는 점을 알 수 있었다.

  • PDF

Effects of the structural strength of fire protection insulation systems in offshore installations

  • Park, Dae Kyeom;Kim, Jeong Hwan;Park, Jun Seok;Ha, Yeon Chul;Seo, Jung Kwan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제13권1호
    • /
    • pp.493-510
    • /
    • 2021
  • Mineral wool is an insulation material commonly used in passive fire protection (PFP) systems on offshore installations. Insulation materials have only been considered functional materials for thermal analysis in the conventional offshore PFP system design method. Hence, the structural performance of insulation has yet to be considered in the design of PFP systems. However, the structural elements of offshore PFP systems are often designed with excessive dimensions to satisfy structural requirements under external loads such as wind, fire and explosive pressure. To verify the structural contribution of insulation material, it was considered a structural material in this study. A series of material tensile tests was undertaken with two types of mineral wool at room temperature and at elevated temperatures for fire conditions. The mechanical properties were then verified with modified methods, and a database was constructed for application in a series of nonlinear structural and thermal finite-element analyses of an offshore bulkhead-type PFP system. Numerical analyses were performed with a conventional model without insulation and with a new suggested model with insulation. These analyses showed the structural contribution of the insulation in the structural behaviour of the PFP panel. The results suggest the need to consider the structural strength of the insulation material in PFP systems during the structural design step for offshore installations.

혹한기 지역에서의 자연순환형 태양열 시스템 동파방지 (Freeze Protection for Passive Solar Water Heating System in Bitter Cold Areas)

  • 권재욱;김종현;홍희기
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.41-46
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and excessive electric power consumption. In the experimental device, hot water in a storage tank was circulated by a small pump and used to heat the outdoor pipes if the cold water pipe surface temperature falls lower than a set point. As a result, It was observed that there was no hot water waste while the solar water heating system operated without freeze and burst.

Condensation Prevention Performance Assessment Taking Into Account Thermal Insulation Performance Degradation Due to Aging for Apartment Housing

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • 제15권6호
    • /
    • pp.11-18
    • /
    • 2015
  • Purpose: The current study analyzed trends in thermal insulation performance with aging, and condensation characteristics caused by the former. Method: Thermal insulation and condensation prevention performance of an architecture were assessed using Temperature Difference Ration Inside, or TDRi. Subjects of this quantitative analysis in thermal insulation performance change due to aging included recently constructed apartments and aged apartments older than 40 years. Time series comparison and analysis were conducted to observed changes in the thermal insulation performance and condensation characteristics. Result: Analysis showed that wall insulation performance degraded with aging regardless of fortified insulating material usage or insulating material type, which caused increased danger of condensation. In addition, when fortified insulating material was installed on the connection between the walls, insulation performance degradation was lower compared to cases in which fortified materials were not used. In all cases from 1 to 10, the rate of thermal insulation performance degradation increased after 20 years of aging.

우주 열환경 모사용 소형 극저온 블로워 설계 및 성능평가 (Design and Performance Test of a Cryogenic Blower for Space Thermal Environment Simulation)

  • 서희준;안성민;허환일
    • 한국항공우주학회지
    • /
    • 제41권10호
    • /
    • pp.833-839
    • /
    • 2013
  • 위성체는 지상에서 우주환경시험을 거쳐 기능 및 작동상태를 점검해야 하며, 이를 위해서는 우주환경을 모사 할 수 있는 우주환경 모사장비가 필요하다. 위성체 및 위성체의 부품 성능을 검증하기 위해 사용되는 열진공 챔버는 진공용기, 진공시스템, 열제어 시스템 등으로 구성이 된다. 특히, 고온 및 극저온의 열환경을 모사하는 열제어 시스템이 열진공 챔버의 핵심이라고 할 수 있으며, 열제어 시스템의 성능은 극저온 블로워의 성능에 의해 결정된다. 본 논문에서는 극저온 블로워의 유동 해석과 블레이드의 구조해석을 통해 원심팬을 설계 하였으며, 구동부와 유체부의 열전달 방지를 위한 열장벽, 모터의 과열 방지를 위한 냉각 시스템 등이 설계되었으며, 이는 열해석을 통해 검증 되었다. 최종적으로 성능실험을 수행하여 극저온 블로워의 성능을 확인하였다.

고효율 LED 방열효과 증대를 위한 융합형 Heat Sink 장치 방열 해석 (A Study on Analysis of Complex Heat Sink System for High Efficiency LED Thermal Effect)

  • 강창수;강기성
    • 전자공학회논문지 IE
    • /
    • 제48권2호
    • /
    • pp.12-18
    • /
    • 2011
  • 본 논문은 조명용 LED 모듈과 히트싱크 장치의 방열 특성을 확인하기 위한 수치 시뮬레이션을 하였다. 해석 케이스는 200 W급의 가로등 또는 보안등용 조명장치이며 용도에 따라 장치의 자세가 달라짐을 고려하여 발광면이 정상부를 향하는 경우와 정하부를 향하는 경우로 나누어서 해석이 진행되었고, 또한 발열소자의 체적이 큰 경우와 작은 경우로 나누어 해석하였다. 해석 결과 현재의 히트싱크 형상으로 충분히 LED의 발열량을 외부로 배출시킬 수 있음을 확인하였고, 장치의 자세와 발열소자의 크기에 따라 방열 성능의 차이가 나타남을 조사하였다.

마이크로 콘트롤러를 이용한 의료용 열전식 프린터 모듈의 개발에 관한 연구 (Design of the Medical Thermal Array Printer Module Based on Microcontroller)

  • 이명호;공인욱;권혁제
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.129-138
    • /
    • 1996
  • This paper describes design techniques of general purpose thermal array printer, especially easily applicable to medical measurement equipment. The'general'means that the proposed thermal array printer can be applied to not only medical field but other industrial field by establishing the eligible protocol. The thermal array printer is composed of i)MPU and its peripherals ii)printer head control, iii)diverse protection circuits, and iv)serial communication. In this paper the performance of the proposed thermal array printer was evaluated by applying to an 3 channel electrocardiogram recorder. The propped system can support'Hangul'text as well as alphanumeric characters and any bitmap image.

  • PDF

내, 외단열 공동주택의 축열체 위치 차이에 따른 동단위 연간 냉난방부하 비교평가 (Comparison of Annual Heating and Cooling Loads of Internally and Externally Insulated Apartment Buildings According to the Location of Thermal Mass)

  • 구보경;이병인;최두성;송승영
    • 한국태양에너지학회 논문집
    • /
    • 제30권1호
    • /
    • pp.42-49
    • /
    • 2010
  • The IIS(Internal Insulation System) is applied in most Korean apartment buildings which are the most common type of residential buildings. Consequently, there are many cases in which the layer of insulation is disconnected by the structural components at the wall-slab and wall-wall joints in the envelope. These joints become thermal bridges where the risk of heat loss increases. It is expected that the EIFS(External Insulation and Finish System) is the solution to this problem. In this study, annual heating and cooling loads of apartment buildings with IIS and EIFS were compared using Design Builder program in order to evaluate the thermal storage effect of EIFS where the concrete thermal mass is located inside of the insulation material. As results, the apartment building with EIFS could reduce annual heating and cooling loads by 2.4% and 4.1%, respectively.