• 제목/요약/키워드: Thermal Power Generation System

검색결과 341건 처리시간 0.03초

해저케이블 고장점 탐지시스템 육상 특성 연구 (Study on the Property of Land for Fault Point Searching System of Submarine Cable)

  • 안용호;정길조;유희영;정창수;박찬영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.578-579
    • /
    • 2005
  • HVDC(High Voltage Direct Current) is an underwater cable between Jeju Island and Haenam in main land and supplies approximately 50% of electrical usage in Jeju Island. If there is any power failure due to HVDC, it will cost approximately 50,000 US dollars per day including Thermal Electrical Generation. Therefore it is absolutely necessary to recover the problem in rapid timely basis. In conclusion, new method and new systems(ULTRA #44 Model) are needed urgently to upgrade current HVDC underwater cable survey technique in Korea to minimize the cost and time factors.

  • PDF

히트파이프를 적용한 LED조명용 핀확장형 냉각시스템 개발 (Development of Fin Expansion Type Cooling System using Heat Pipes for LED Lightings)

  • 정태성;강환국
    • 소성∙가공
    • /
    • 제21권2호
    • /
    • pp.131-137
    • /
    • 2012
  • With the advantages of power savings, increased life expectancy and fast response time over traditional incandescent bulb, LEDs are increasingly used for many applications including automotive, aviation, display, and special lighting applications. Since the high heat generation of LED chips can reduce service life, degrade luminous efficiency, and cause variation of color temperature, many studies have been carried out on the optimization of LED packaging and heat sinks. In this study, a fin expansion type cooling device using heat pipe, instead of a solid aluminum heat sink, was designed for LED security lightings based on thermal resistance analysis. Numerical analysis and experimental validation were carried out to evaluate its cooling performance.

독립형 풍력발전 시스템용 축전지 운전 특성 및 노화평가 시험 (Inverstigation of Thermal Aging Effect of Battery for Stand-Alone Type Wind Power Generation system)

  • 김희중;주찬홍;이준현;송승호;신찬;김동용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.129-132
    • /
    • 2002
  • 대체 에너지(태양광, 풍력등)의 전력저장 시스템으로 널리 사용되는 겔형(Gel Type) 밀폐형 연(鉛)축전지의 노화 특성 평가 및 충전회로에 관하여 연구하였다. 납 합금을 이용한 기판 주조 기술과 전해액(Gel) 배합기술이 축전기 성능과 수명을 좌우하며 또한 배터리 충전 시스템에 따른 온도 상승이 치명적인 영향을 미치게 된다. 따라서 본 연구에서는 적외선 열화상 장치를 이용한 내부 열원 추적에 의해 노화정도를 측정하며 축전지 수명시험을 통해 입수한 데이터와 비교 평가하고자 한다. 현재 실험실 충방전 수명시험을 마치고 (주)코윈텍이 부안 해창 공원에 설치한 30kW급 풍력발전 시스템에 적용하여 Field Test를 시험중이다.

  • PDF

Review of small hydropower system

  • Jantasuto, Orawan
    • International Journal of Advanced Culture Technology
    • /
    • 제3권1호
    • /
    • pp.101-112
    • /
    • 2015
  • Renewable energy resources play an important part in the world's future. Renewable energy sources have the following components: biomass, geothermal, solar thermal, directs solar, wind, tidal and hydropower. Hydropower is still the most efficient way to generate electricity worldwide. Hydropower projects can contribute as a cheap energy source, as well to encourage the development of small industries across a wide range of new technology; furthermore hydropower systems use the energy in flowing and falling water to produce electricity or mechanical energy. Hydropower systems are classified as large, medium, small, mini and micro according to their installed power generation capacity, as do the following components: water turbines, control mechanisms and electrical transmissions. In this article a review of small hydropower systems has been done on the principles surrounding the fundamentals of hydraulic engineering, the fundamentals of hydrology, identification of sites and economic analysis.

냉동기운전 고온초전도코일의 안정성평가기준에 관한 연구 (A study on stability criterion for cryocooler-operating HTS coils)

  • 석산돈사;정수지사;김석범;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.587-589
    • /
    • 2000
  • In this paper, the stability criterion for cryocooler-cooled high-temperature superconducting (HTS) coils is discussed. We choose the current, Itr at which "thermal runaway" occurs, as a stability criterion and adopt the relationship between the cooling power of GM cryocooler and the heat generation in coil system to evaluate Itr. We also investigate the transient behavior during a quench process in HTS coils by a newly developed FEM computer program.

  • PDF

정적 연소실에서의 열 손실 해석 모델 (Analysis of Heat Loss Effect of Combustion in Closed Vessel)

  • 이대훈;권세진
    • 한국연소학회지
    • /
    • 제6권1호
    • /
    • pp.14-19
    • /
    • 2001
  • Interests and importance of down-scale combustor is increasing with the emerging need for miniaturized power source which is now a bottleneck of micro system development. But in down scaled combustor increased heat loss compared to thermal energy generation inhibits the usability and application of the device, so as a preliminary work of down scaled combustor fabrication. Modeling tool for the device should be established, in this study modeling approach of closed vessel combustion phenomena that can express heat loss effect and resulting quenching is proposed and the result is compared with experiment data. From this model heat loss effect following combustor scale down can be further understood, and further more design parameter and analysis tool can be obtained.

  • PDF

정수계획법과 선형계획법을 이용한 CO2 배출량 제약과 배출권거래하의 설비계획 비교/ 분석 (Analysis of Generation Explansion Planning Considering CO2 Emission Constraints and Emission Trading under using LP(Linear Programing) and MIP(Mixed Integer Programing))

  • 신혜경;홍희정;강동주;한석만;정구형;김발호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.816-817
    • /
    • 2007
  • As UNFCC(United Nations Framework Convention on Climate Change) is enhanced, Korea will perform a CO2 reduction duty. The CO2 reduction duty will effect Korea power system because coal and oil thermal generations emit large CO2 form about 46% of total CO2 emission. Moreover various alternatives should be designed to comply with CO2 reduction duty. In this paper, we analysis resource planning considering CO2 emission constraints and emission trading. And we analysis resource planning under using LP(Linear Programing) and MIP(Mixed Integer Programing).

  • PDF

핀-휜을 삽입한 채널의 열전달 및 압력강하 특성 실험 (Experiments on the Heat Transfer and Pressure Drop Characteristics of a Channel with Pin-Fin Array)

  • 신지영;손영석;김상민;이대영
    • 설비공학논문집
    • /
    • 제16권7호
    • /
    • pp.623-629
    • /
    • 2004
  • Rapid development of electronic technology requires small size, high density packaging and high power of electronic devices, which result in more heat generation by the electronic system. Present cooling technology may not be adequate for the thermal management in the current state-of-the-art electronic equipment. Forced convective heat transfer in a channel filled with pin-fin array is studied experimentally in this paper as an alternative cool-ing scheme for a high heat-dissipating equipment. Various configurations of the pin-fin array are selected in order to find out the effect of spacing and diameter of the pin-fin on the heat transfer and pressure drop characteristics. In the low porosity region, interfacial heat transfer and pressure drop seem to show different trend compared to the conventional heat transfer process.

핀-휜 구조물을 이용한 채널의 냉각특성 해석 (Analysis on the Cooling Characteristics of a Channel with Pin-Fin Structure)

  • 신지영;손영석;이대영
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.667-673
    • /
    • 2003
  • Recent trends in the electronic equipment indicate that the power consumption and heat generation in a chip increase as the components are miniaturized and the computing speed becomes faster. Suitable heat dissipation is required to ensure the guaranteed performance and reliable operation of the electronic devices. The aim of the present study is to investigate the forced-convective thermal-hydraulic characteristics of a pin-fin heat exchanger as a candidate for cooling system of the electronic devices. The influence of the structure of the pin-fin assembly on heat transfer is investigated by porous medium model. The results are compared with the experimental data or correlations of several researchers for the heat transfer coefficients for the channel flow with pin-fin arrays. Finally, the effects of design parameters such as the pin-fin diameter and the spacing are examined.