• Title/Summary/Keyword: Thermal Imaging

Search Result 623, Processing Time 0.063 seconds

Design and Implementation of Livestock Disease Forecasting System (가축 질병 예찰 시스템 설계 및 구현)

  • Kim, Hyun-Gi;Yang, Cheol-Ju;Yoe, Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37C no.12
    • /
    • pp.1263-1270
    • /
    • 2012
  • Livestock disease that decreases the farm productivity and income leads to not only financial loss but also national loss from the spread of contagious disease. The purpose of this paper is to propose a livestock disease forecasting system that can diagnose disease of livestock at an early stage based on the livestock activity and body temperature. The proposed livestock disease forecasting system collect data on livestock activity and body temperature using a acceleration sensor and thermal imaging camera and comparing the data with control according to disease. It is expected that, this system can be accurately identify and prevent spread of livestock disease beforehand to minimize damages caused by disease to improve the productivity and the rate of return of livestock farms.

An Experimental Study on the Squeal Noise Generation due to Dynamic Instability of Brake Pad (브레이크 패드의 동적 불안정성에 따른 스퀼 소음 발생 원인의 실험적 연구)

  • Cho, Sangwoon;Lim, Byoungduk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.5
    • /
    • pp.520-526
    • /
    • 2016
  • Squeal noise is a typical brake noise that is annoying to both passengers and pedestrians. Its frequency range is fairly wide from 1 kHz to 18 kHz, which can be distressful to people. The brake squeal noise occurs due to various mechanisms, such as the mode coupling of the brake system, self-excited vibration, unstable wear, and others. In this study, several parameters involved in the generation of a squeal noise are investigated experimentally by using a brake noise dynamometer. The speed, caliper pressure, torque, and friction coefficient are measured as functions of time on the dynamometer. The contact pressure and temperature distributions of the disc and the pad are also measured by using a thermal imaging camera and a pressure mapping system. As a result of the simultaneous measurement of the friction coefficient and squeal amplitude as functions of the velocity, it is found that the onset of the squeal may be predicted from the ${\mu}-v$ curve. It is also found that a non-uniform contact pressure causes instability and, in turn, a squeal. Based on the analysis results, design modifications of the pad are suggested for improved noise characteristics.

Effects of Walking with Non-Electric Power Vibration Shoes on Body Temperature and Peripheral Circulation (무전력형 진동신발 보행이 체온과 말초 혈액순환에 미치는 영향)

  • Lee, Hyun Ju;Lee, Cheong Gn;Tae, Ki Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.235-241
    • /
    • 2019
  • The purpose of this study was to investigate the effect of the body temperature peripheral circulation with vibration shoes in healthy 10 adults. The magnetic vibration device with non-electric power was mounted in the midsole of the vibration shoes. The experiment was divided into two groups: vibration shoes and no vibration shoes. Subjects were randomly selected and measured body surface temperature by digital infrared thermal imaging (DITI) and non-invasive capillaries change by nailfold microscope (NFM). After walking in a treadmill for 15 minutes at 4.0 km/h speed wearing normal shoes or vibration shoes, DITI and NFM were measured. The walking with vibration shoes showed the body surface temperature shift from the proximal to the distal. In addition, the diameter of the nailfold capillary in the vibration shoes group was thicker and clearer due to the increased blood flow than that of the no vibration shoes group. The vibration shoes are easy to apply to anyone who can walk because it can give vibration stimulation by walking without additional time, cost, and effort in daily life. Further studies are needed to explain the physiological effects of vibration frequency and intensity on the long-term perspective of target subjects resulting from vascular dysfunction.

Comparison study of effects of magnetic therapy at Hap-Kok(LI4 ) on the thermal change of Chun-Choo(ST25) in man (합곡(合谷)(L14)의 자침(刺鍼)과 자석외첩(磁石外貼)이 천추(天樞)(S25) 부분(部分) 영역(領域)의 온도변화(溫度變化)에 미치는 영향(影響) 비교(比較))

  • Baek Tae-Ho;Park Ryoung-Jun
    • Journal of Korean Medical Ki-Gong Academy
    • /
    • v.5 no.1
    • /
    • pp.22-39
    • /
    • 2001
  • This study is designed to compare the effect of a needle with the magnet on body. We took the skin temperature of the belly with digital infrared thermographic imaging while we sticked needle and apply magnets on L14. We made experiments on 40 healthy male volunteers for one month. We classified control group not acupuncture or magnet adhering(CON). acupuncture group on left and right L14(LA). and the permanent magnet group adhering to left and right(LM). And LM is divided into S-polar permanent magnet group(LMS) and N-polar permanent magnet group adhering to left and right L14(LMN). When we observed that temperature changed with time, the skin temperature of th belly in CON descended significantly but LM, LMS and LMN is not changed significantly. As mentioned above. we observed that the needles on L14 affected the change of temperature on the belly, and conjectured that the appliance of magnets had the same results. If the mechanism depends on the meridian of body and energy. we suppose that the appliance of magnets and needles has same effects.

Atomic Force Microscopy Force Mapping Application in Biomedical Research (원자현미경의 나노 힘 측정을 이용한 생의학 연구에의 응용)

  • Cho S.J.;Lee D.J.;Kim E.P.;Lee D.R.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.77-80
    • /
    • 2005
  • Local probe techniques such as scanning probe microscopy (SPM) or atomic force microscopy (AFM) extended our perception into ultra small world. Specially, the sense of touching was extended by AFM into the micro- and nanoworld and has provided complementary new insights of the microscopic world. In addition, touching objects is an essential step before trying to manipulate things. SPM as a touch sensor not only measure the mechanical properties but also detect different properties such as magnetic, electrical, ionic, thermal, chemical and biophysical properties in nanoscale and even less. Obtaining biophysical measurements, monitoring dynamics and processes together with high-resolution imaging of the biomolecules and cells with rather simpler sample preparation than any other techniques give great attractions to the scientists experimenting with biological samples. Among the many AFM capabilities we will specifically introduce the force plot which is used to measure tip-sample interactions and its application this time.

  • PDF

A Comparative Study of Algorithms for Estimating Land Surface Temperature from MODIS Data

  • Suh, Myoung-Seok;Kim, So-Hee;Kang, Jeon-Ho
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.1
    • /
    • pp.65-78
    • /
    • 2008
  • This study compares the relative accuracy and consistency of four split-window land surface temperature (LST) algorithms (Becker and Li, Kerr et ai., Price, Ulivieri et al.) using 24 sets of Terra (Aqua)/Moderate Resolution Imaging Spectroradiometer (MODIS) data, observed ground grass temperature and air temperature over South Korea. The effective spectral emissivities of two thermal infrared bands have been retrieved by vegetation coverage method using the normalized difference vegetation index. The intercomparison results among the four LST algorithms show that the three algorithms (Becker-Li, Price, and Ulivieri et al.) show very similar performances. The LST estimated by the Becker and Li's algorithm is the highest, whereas that by the Kerr et al.'s algorithm is the lowest without regard to the geographic locations and seasons. The performance of four LST algorithms is significantly better during cold season (night) than warm season (day). And the LST derived from Terra/MODIS is closer to the observed LST than that of Aqua/MODIS. In general, the performances of Becker-Li and Ulivieri et al algorithms are systematically better than the others without regard to the day/night, seasons, and satellites. And the root mean square error and bias of Ulivieri et al. algorithm are consistently less than that of Becker-Li for the four seasons.

Percutaneous osteoplasty for painful bony lesions: a technical survey

  • Kim, Won-Sung;Kim, Kyung-Hoon
    • The Korean Journal of Pain
    • /
    • v.34 no.4
    • /
    • pp.375-393
    • /
    • 2021
  • Percutaneous osteoplasty (POP) is defined as the injection of bone cement into various painful bony lesions, refractory to conventional therapy, as an extended technique of percutaneous vertebroplasty (PVP). POP can be applied to benign osteochondral lesions and malignant metastatic lesions throughout the whole skeleton, whereas PVP is restricted to the vertebral body. Common spinal metastases occur in the thoracic (70%), lumbosacral (20%), and cervical (10%) vertebrae, in order of frequency. Extraspinal metastases into the ribs, scapulae, sternum, and humeral head commonly originate from lung and breast cancers; extraspinal metastases into the pelvis and femoral head come from prostate, urinary bladder, colon, and uterine cervical cancers. Pain is aggravated in the dependent (or weight bearing) position, or during movement (or respiration). The tenderness and imaging diagnosis should match. The supposed mechanism of pain relief in POP is the augmentation of damaged bones, thermal and chemical ablation of the nociceptive nerves, and local inhibition of tumor invasion. Adjacent (facet) joint injections may be needed prior to POP (PVP). The length and thickness of the applied needle should be chosen according to the targeted bone. Bone cement is also selected by its osteoconduction, osteoinduction, and osteogenesis. Needle route should be chosen as a shortcut to reach the target bony lesions, without damage to the nerves and vessels. POP is a promising minimally invasive procedure for immediate pain relief. This review provides a technical survey for POPs in painful bony lesions.

Focal Bone Marrow Lesions: A Complication of Ultrasound Diathermy

  • Kim, Seung Jae J.;Kang, Yusuhn;Kim, Dae Ha;Lim, Jae Young;Park, Joo Hyun;Oh, Joo Han
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.1
    • /
    • pp.40-45
    • /
    • 2019
  • Ultrasound diathermy is widely used for the treatment of musculoskeletal disorders and other soft tissue injuries. Its use as a therapeutic modality is believed to be safe, with very few reported complications. Here, we report two patients who developed focal bone marrow abnormalities after receiving ultrasound diathermy. Both patients' magnetic resonance (MR) evaluations revealed linear subchondral bone lesions of the superolateral humeral head similar to those in osteonecrosis. The patients' symptoms subsequently improved, and available follow-up MR evaluation revealed near complete resolution of bone lesions. These findings suggest that ultrasound diathermy, and its interaction with bone tissue through thermal mechanisms, can cause focal bone marrow abnormalities. Furthermore, the bone marrow abnormalities seem to be transient, resolving upon cessation of ultrasound diathermy, therefore osteonecrosis should be differentiated from this temporal lesion.

A Case of Cold Hypersensitivity from Hypothyroidism of Soeumin Diagnosed as Greater Yang Disease Reverting Yin Pattern (소음인 태양병궐음증으로 진단한 갑상선 기능저하증으로 인한 수족냉증 치험 1례)

  • Lee, Yong-jae;Lee, Seul;Kim, So-hyoung;Lee, Jeongyun;CHAE, Han
    • Journal of Sasang Constitutional Medicine
    • /
    • v.31 no.1
    • /
    • pp.102-112
    • /
    • 2019
  • Objectives The purpose of this case study was to report that cold hypersensitivity caused by hypothyroidism was alleviated by diagnosing and treating as Greater Yang Disease Reverting Yin Pattern. Methods The patient was administered Insamosuyu-tang and Sammisamyu-tang and treated with acupuncture. Global Assessment Scale (GAS) and Digital Infrared Thermal Imaging (DITI) was used to assess the improvements of symptoms. Results and Conclusions Cold hypersensitivity of hands and feet was improved to GAS 20, and hours of sleep were increased from one to six. On DITI, the increase of the temperature were 1-3 degree celsius on the chest and the abdomen, 0.2-1 degree on the forearms and the hands, 1-2 degree on the thighs, and 0.2-0.5 degree on the shins and the feet.

Spatial and Temporal Electrodynamics in Acuzones: Test-Induced Kinematics and Synchronous Structuring. Phenomenological Study

  • Babich, Yuri F.;Babich, Andrey Y.
    • Journal of Acupuncture Research
    • /
    • v.38 no.4
    • /
    • pp.300-311
    • /
    • 2021
  • Background: So far there is no confidence in the basics of acupoint/meridian phenomena, specifically in spatial and temporal electrical manifestations in the skin. Methods: Using the skin electrodynamic introscopy, the skin areas of 32 × 64 mm2 were monitored for spectral electrical impedance landscape with spatial resolution of 1 mm, at 2 kHz and 1 MHz frequencies. The detailed baseline and 2D test-induced 2 kHz-impedance phase dynamics and the 4-parameter time plots of dozens of individual points in the St32-34 regions were examined in a healthy participant and a patient with mild gastritis. Non-thermal stimuli were used: (1) (for the sick subject), microwaves and ultraviolet radiation applied alternately from opposite directions of the meridian; and (2) (for the healthy one) microwaves to St17, and cathodic/anodic stimulation of the outermost St45, alternately. Results: In both cases, the following phenomena have been observed: emergence of in-phase and/or antiphase coherent structures, exceeding the acupoint conditional size of 1 cm; collective movement along the meridian; reversible with a reversed stimulus; counter-directional dynamics of both whole structures and adjacent points; local abnormalities in sensitivity and dynamics of the 1 MHz and 2 kHz parameters indicating existence of different waveguide paths. Conclusion: It is assumed that these findings necessitate reconsideration of some basic methodological issues regarding neurogenic/acupuncture points as spatial and temporal phenomena; this requires development of an appropriate approach for identifying the acuzones patterns. These findings may be used for developing new approaches to personalized/controlled therapy/treatment.